Tender For Work Contract For Construction Of New Rest House Along With Electrification Work Including Supply Of Electrical Materials At Atps, Mppgcl, Chachai.(Price Bid No. 1)
Tender Overview
Project Description
Tender for Work Contract For Construction Of New Rest House Along With Electrification Work Including Supply Of Electrical Materials At Atps, Mppgcl, Chachai.(Price Bid No. 1)
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-Oct-2026 | FIRST EXTENSION OF DUE DATE | Date | 02-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | MPPWD SOR 2024 Sr. No.31.7.5 - Downlight LED Fitting , 20 Watt, color temp 3000-6500k Supply and fixing recessed mounting LED down lighter, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium/CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79- 08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.. |
| 2 | MPPWD SOR 2024 Sr. No.31.3.4 -LED 20 w batten light Tube light LED 1 X 20/22Watt, Integral i/c batten aluminium body PC diffuser. Supply and fixing Led tube rod comprising of LED tube with nonintegral/ integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. |
| 3 | MPPWD SOR 2024 Sr. No.30.6.1- Deluxe fresh air Exhaust fans 300mm RPM1300/1400 Supplying and fixing of deluxe fresh air fan with louvers (ventilating fan) with self-closing louvers of decorative PVC blades mounting square frame of approved make complete with all necessary material. |
| 4 | MPPWD SOR 2024 Sr. No.30.1.4-Ceilling Fans 1200 mm sweep, Ornamental fan BLDC Ceiling Fan (ISI marked)-1200 mm Sweep, with minimum air delivery 210 m³/min and service value ≥ 4.00 as per BEE. Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, without regulator, A.C. 230-250 volts including connections with all necessary material complete of approved as required confirming to IS :374/2019 with upto date amendments. |
| 5 | MPPWD SOR 2024 Sr. No.29.25.2-Modular electronic fan regulator, 100 Watt(2 module) Supply and fixing of approved make step type modular electronic fan regulator including connection etc. as required on existing board |
| 6 | MPPWD SOR 2024 Sr. No.32.3- Fan box Providing and fixing circular/hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by mean of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing. |
| 7 | MPPWD SOR 2024 Sr. No. 49.11.4-SPLIT AC (Inverter model, Heating & Cooling) 1.5 TR star rating 5 star 1.5 TR star rating 5 star,SPLIT AC (inverter model) :- Supply, installation, testing and commissioning of Split type wall mounted air conditioning unit of following capacity including indoor, outdoor unit fitted with inverter based rotary compressor, copper condenser and first charge refrigerant R410A. The condensing unitworking range should be capable for providing cooling between +/-5 deg. C to 50 deg. C & heating within 0 deg. C to 15 deg. C including connection of copper pipe of required size upto 3 mtr., insulation, cordless remote control, auto air swing louvers, wall stand for outdoor unit, connection copper lead wire, condensed water outlet pipe 2 mtr. complete etc as required. Outdoor/indoor units should be of same make (brand). |
| 8 | MPPWD SOR 2024 Sr. No. 38.6- Telephone point , RJ-11 telephone jackmodular Supply, fixing and testing of RJ 11 telephone jack modular (1 Module) |
| 9 | MPPWD SOR 2024 Sr. No. 38.8-T.V. outlet modular Cable pointSupply, fixing and testing of T.V. outlet modular (1Module) |
| 10 | MPPWD SOR 2024 Sr. No. 57.2.2-LED TV 42”/43” Supply, installation, testing & commissioning of L.E.D. Television (4K L.E.D. Display ,Full HD (1080p) O.S. Webos /Android or equivalent, minimum 50 Hz refresh rate Min. 20 W speaker, Wifi/bluetooth enabled, minimum 2 HDMI & 1USB Port, i/c remote and wall/table top accessories) |
| 11 | MPPWD SOR 2024 Sr. No. 57.9.1-GEYSER Hot water storage water heater 15 Ltr. Supplying and fixing of hot water storage water heatervertical with required safety, ABS body including connection pipe, foundation bolt and nut, connection pipe, stop cock, testing etc. to complete the job. 15 Ltr. (5 Star rating- standing losses ≤0.419 kWh/24 hrs/45°C) |
| 12 | MPPWD SOR 2024 Sr. No. 54.9.1- 4MP IP varifocal MFZ dome camera 2.7-13.5 MM (Indoor) Supply, installation testing and commissioning of the IP rugged dome camera shall be equipped with a 1/3″ 4 MP progressive scan CMOS imager to capture full HD 1080p (25/30 fps)//2688 × 1520 (20fps) images, 2.7 -13.5 mm, MFZ lens, digital zoom 16x and a waterproof (IP66) IK10 impact-resistant camera housing, As a true day/night solution, the camera shall use smart IR technology and provide up to 145 ft (45 m) of IR illumination. The camera shall accept PoE (802.3af) or 12 V DC power input. min. illumination:-0.08 lux color @ F2.0 (color, 1/3s, 30 IRE),0 lux B/W with IR LEDs on @ F2.0) video compression :- H.265 +, noise reduction: 3DNR,backlight compensation :- True WDR 120 DB, angle of view 104°/87° (H), 57°/48° (V) ,UL listed |
| 13 | MPPWD SOR 2024 Sr. No. 54.10.1-CCTV CAMERA. 4MP IP varifocal MFZ IR bulletcamera (Outdoor) Supply, installation testing and commissioning of the IP bullet camera shall be equipped with a 1/3″ 4 MP progressive scan CMOS imager to capture full HD 1080p (25/30 fps)/2688 × 1520 (20fps), images, 2.7 -13.5 mm, MFZ lens, digital zoom 16x and a waterproof (IP66) IK10 impact-resistant camera housing, as a true day/night solution, the camera shall use smart IR technology and provide up to 164ft (50 m) of IRillumination. The camera shall accept PoE (802.3af) or 12 V DC power input. min. illumination:-0.08 lux color @ F2.0 (color, 1/3s, 30 IRE),0 lux B/W with IR LEDs on @ F2.0) video compression :- H.265 +, noise reduction: 3DNR,backlight compensation :- True WDR 120 DB, angle of view104°/87° (H), 57°/48° (V) ,UL listed. |
| 14 | MPPWD SOR 2024 Sr. No. 7.1.1.3-Power point Long wiring concealed steel rigid conduit with 16 amp switch socket Point wiring (excluding metallic switch box & sheet) for 3 pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid steel conduit ISI marked of suitable size including painting etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of. |
| 15 | MPPWD SOR 2024 Sr. No. 18.2.3-Power point Switch Board 4 Modular (GI Modular Box) Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal. |
| 16 | MPPWD SOR 2024 Sr. No. 1.2 Socket same board 6A Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3/5 pin 6 Amp. Socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid steel conduit ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on same board. |
| 17 | MPPWD SOR 2024 Sr. No. 29.3.3- Ding dong bell Call bell Supply and fixing as per specification call bell/buzzer of approved make with necessary materials complete. |
| 18 | MPPWD SOR 2024 Sr. No. 18.2.2 -Switch Board (GI Modular Box) 3 Module Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required |
| 19 | MPPWD SOR 2024 Sr. No. 18.2.3-Switch Board (GI Modular Box) 4 Module Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required |
| 20 | MPPWD SOR 2024 Sr. No. 18.2.4- Switch Board (GI Modular Box) 6 Module Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required |
| 21 | MPPWD SOR 2024 Sr. No. 18.2.5-Switch Board (GI Modular Box) 8 Module Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required |
| 22 | MPPWD SOR 2024 Sr. No. 18.2.6- Switch Board (GI Modular Box) 12 Module Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required |
| 23 | MPPWD SOR 2024 Sr. No. 27.8.2.2 -M.C.B. DP (power) 16 A Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures |
| 24 | MPPWD SOR 2024 Sr. No. 27.8.2.2- M.C.B. DP (power) 20 A Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures |
| 25 | MPPWD SOR 2024 Sr. No. 27.8.2.3- MCB DP isolator 40A Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures |
| 26 | MPPWD SOR 2024 Sr. No. 27.8.2.2-M.C.B. DB (Light) 10A Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures |
| 27 | MPPWD SOR 2024 Sr. No. 28.4.1-Fixing of MCB/MCCB/ Isolator, Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete |
| 28 | MPPWD SOR 2024 Sr. No. 2.1.1.1- Point Wiring – Short Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid steel conduit ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit including painting, screwless connector for joints etc. as required as per specification. |
| 29 | MPPWD SOR 2024 Sr. No. 2.1.1.2- Point Wiring – MediumPoint wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid steel conduit ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit including painting, screwless connector for joints etc. as required as per specification for :- |
| 30 | MPPWD SOR 2024 Sr. No. 2.1.1.3-Point Wiring – Long Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid steel conduit ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit including painting, screwless connector for joints etc. as required as per specification for :- |
| 31 | MPPWD SOR 2024 Sr. No. 13.1.1- Concealed M.S. conduit H.G. 20mm (Lighting) H.G. conduit 20 mm, wall thickness 1.6mm Supplying and fixing rigid steel conduit ISI marked along with the accessories in concealed system including cutting the wall and plastering & repainting the wall with matching colour to bring in its original condition as required |
| 32 | MPPWD SOR 2024 Sr. No. 13.1.1- MS Conduit 20mm (Power) H.G. conduit 20 mm, wall thickness 1.6mm Supplying and fixing rigid steel conduit ISI marked along with the accessories in concealed system including cutting the wall and plastering & repainting the wall with matching colour to bring in its original condition as required |
| 33 | MPPWD SOR 2024 Sr. No. 27.11.6-SPN MCB Room DB (Way & Contents) 12 Way DB Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator)- |
| 34 | Non SOR - Key-card switch 20A Supply and fixing key card switch. |
| 35 | MPPWD SOR 2024 Sr. No. 52.6.1 -Modular contactor for the lighting feeder panel Power contactor (25 A), for Key-card switch Supply, installation, testing and commissioning of 25A rating four pole contactor, designed specific contact material AgSnO2 for lamp loads and AC load for high starting current. It shall work at an ambient temperature of -20 to +50 deg C and auto-On-Off selector version. It shall have 3 Kv short circuit protections. The mounting shall be on 35 mm DIN rail (EN 60715) |
| 36 | MPPWD SOR 2024 Sr. No. 31.19.2-LED Bulkhead 10W Supplying, fixing and testing of approved make LED bulkhead ABS body, PC diffuser including fixing on wall as required, with necessary material complete. 10W IP 55 |
| 37 | MPPWD SOR 2024 Sr. No. 31.13.3- LED street Light90Watt, color temp 3000-6500k as required Supply and fixing street light with high power LED of 3 to 6 Watt each on existing bracket assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF> 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347 i/c connection wire, testing etc. to complete the job. |
| 38 | MPPWD SOR 2024 Sr. No. 42.98.11 -Octagonal GI Pole 12 meter height, 210 X 90mm A/F, 300x300x16mm base plate having weight 153 kg ±3%, 4 nos. X 24 x 750mm bolt having weight 12 kg ± 3%. Providing and erection of hot dipped galvanized octagonal poles in single section made from 3mm thick sheet having lockable weather proof flush door junction box, suitable size& typeof foundation bolts 4 nos. 'J' type (EN8 grade) complete, erected in an approved manner on provided foundation. |
| 39 | MPPWD SOR 2024 Sr. No. 42.111-Foundation for octagonal pole Designing and construction of footing foundation for octagonal pole of desired size including excavation in soil/softrock,baseconcreteM-7.5(1:4:8),15mmthick andpedestalofRCCM-20(1:1.5:3),requiredtarsteel reinforcement for required size from base concrete, shuttering, curing etc. with existing foundation bolts complete as per specifications in an approved manner as per manufacturer drawing or engineer-in-charge. |
| 40 | MPPWD SOR 2024 Sr. No. 42.99-Bakelite sheet MCBSP & stud type 4 way epoxy connector for decorative /octagonal pole box. Providing & fixing 10 mm thick bakelite sheet with MCB (6–32A SP) and 16 sq.mm stud type 4-way epoxy connector inside pole box |
| 41 | MPPWD SOR 2024 Sr. No. 42.105.3- Double arm standard bracketProvidingandfixingof2000mmlongDouble ArmGI Hot Dip Galvanized Bracket with 42.4mm OD and 3.2mmthickPipe.Canopypipeshouldbe500mmwith 4 Nos 10mm dia Pinch bolts. |
| 42 | MPPWD SOR 2024 Sr. No. 42.97- 20 meter high mast lighting Providinganderectiononexistingfoundation20meter high mast lighting system suitable to install upto 10 No. 2 x 250/ 400 w M.H/S.V/LED flood light and control gear with integral Power tool, weight 450 kg. comprising of 2 sections of hot dipped galvanized materialsasper BSEN ISO 1461 thickness 3 mm&4 mm, dia 150mm & 410mm for top and bottom respectively, stress fitting arrangement on site with 500mm overlap dynamic loading to withstand max wind pressure as per -IS 875 part III, parameters for structural & foundation design must be taken from wind tunnel test. Lightning protection of GI single spike 1200mm at top and at base inside compartment havingdoublethickness3mm&4mm,dia150mm& 410mm for top and bottom respectively, stress fitting arrangement on site with 500mm overlap dynamic loadingtowithstandmaxwindpressureasper-IS875 part III, parameters for structural & foundation design must be taken from wind tunnel test. Lightning protection of GI single spike 1200mm at top and at base inside compartment having double internal lock with adequate size of MCB erected on PVC board complete with base plate of 25mm thick 570mm dia. and foundation bolts having 8 nos. bolts of 30mm dia 850 mm long (EN.8 grade) Anchor plate 490 PCD, including accessories viz.(1) Lantern carriageof 50 NB ERWclass-B, MS pipe coveredwithPVCsleevesuitabletocarry500kg.load and upto 10 fittings symmetrically.(2) Trailingcopper cable5x4.0 sq.mm, PVC insulated PVC sheathed.(3) Double drum 750Kg Winch having gear 53:1, oil bath (SAE90/140) arrangement.(4) 2 nos. stainless steel wire ropes 6 mm dia (7/19) breaking load capacity 2350 kg. x 2,(5) Integral power tool 3-phase, 1HP 2m/min single speed .torque limiter upto 500 kg adjustable(6) 2 Nos. LED 300 nos. aviation light (7) Feeder pillar fabricated out of 14 SWG CRCA sheet and comprise of incoming MCB 63 A TPN switch, HRC fuses, single dial timer, suitable size of contactorsforlightingandpowertool,2nos.outgoing, reversing switch for motor. (8) Foundation drawing, test certificate and guarantee certificateshall beprovided bymanufacturer. (without fixture and lamp) |
| 43 | MPPWD SOR 2024 Sr. No. 31.14.8 LED flood light , 250Watt, color temp 3000-6500k as required. Supplying and fixing flood light with high power LED of 3 to 6 Watt each assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF > 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. |
| 44 | MPPWD SOR 2024 Sr. No. 31.16.1- LED Bollard Light 10W cylindrical shape Supply, fixing & testing of approved make of LED integral type bollard cylindrical/square shape housing cast aluminium dome shape top cover fixed with cylindrical shape acrylic cover having base plate with holes for direct mounting complete with all accessories including preparation of foundation, fixing, connection etc. as required. LED of 1 to 3 Watt each assembled on single MCPCB, system lumens output with efficacy>90 lm/W. luminaire having color temp upto 6500K & 50000 burning hrs. life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare, comprises of driver PF> 0.95 & surge protection 10KV. IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. |
| 45 | MPPWD SOR 2024 Sr. No. 31.11.2- Post top lantern LED fitting 25WSupply and fixing integral post top lantern LED fitting comprises of copper dust finish cast aluminium spigot and spun aluminium canopy fixed with opal polycarbonate, pipe arrangement for vertical mounting, open construction driver and accessories are wired upto terminal block. LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100lm/Watt. LED driver PF > 0.95 & surge protection 10KV. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. |
| 46 | MPPWD SOR 2024 Sr. No. 42.107.1 -Decorative designer poles 3 meter Height Providing and erection of black painted galvanized decorative designer poles in different section, top 60mm dia., bottom 140mm dia. with gold colour painted ornamental cast aluminium ring having lockable weather proof flush door junction box in bottom section, base plate dia. 290mm having 4 holes of 22mm dia. complete erected in an approved manner on existing foundation. Suitable size & type of foundation bolts 4 nos. X 16mm X 450mm 'J' type (EN8 grade) |
| 47 | MPPWD SOR 2024 Sr. No. 42.111-Foundation for octagonal pole Designing and construction of footing foundation for octagonal pole of desired size including excavation in soil/soft rock, base concrete M-7.5 (1:4:8), 15mm thick and pedestal of RCC M-20 (1:1.5:3), required tar steel reinforcement for required size from base concrete, shuttering, curing etc. with existing foundation bolts complete as per specifications in an approved manner as per manufacturer drawing or engineer-in-charge. |
| 48 | MPPWD SOR 2024 Sr. No. 56.5.3- Recessed ground mounted deep LED FACADE uplighter 9W recess deep uplight Supply and fixing of recessed ground mounted deep LED uplighter fixture with Honeycomb Louver. protected Uno PATHFINDER IP66 2700K-5500K 8deg-24deg as required. stainless steel body hard anodized aluminium finishes stainless steel & IK rating 08. Installation housing box power supply cables35 cm NS20N PCP 2x0,5 mm2 power supply 24V DC power consumption max 9 Watt lumen output 240-680lm working temperature-20°C +45°C IP rating IP66 (not for permanent immersion) insulation class III Weight upto 500gm. and delivers 90CRI for excellent colour rendering, and with binning-free LEDs carefully selected from two-step Macadam’s ellipse. PATHFINDER is smart shield protected against polarity inversion, an integrated super fast diode prevents accidental damage to the luminaire during installation on due to reverse polarity. Smart shield protects against ‘hot-plugging’. Fully integrated spike-reduce on protects the constant- current driver and prevents damage to the LED die surface. With housing box included and LED driver in IP66 casing box included. |
| 49 | MPPWD SOR 2024 Sr. No. 41.15.1- UG Lighting Cable Laying, 1.1KV grade of sizenot exceeding 25 sq. mm Laying of one number armoured / unarmoured power cable 1.1KV grade of size not exceeding 25 sq. mm direct inground including excavation in all soil/ murrum /soft rock, sand cushioning, protective covering and refilling the pit etc. as required. |
| 50 | MPPWD SOR 2024 Sr. No. 41.15.2-UG Power Cable Laying, 1.1.KV grade of sizeexceeding 25sq. mm but not exceeding 120 sq. mm Laying of one number armoured / unarmoured power cable 1.1.KV grade of size exceeding 25sq. mm but notexceeding 120 sq. mm direct in ground including excavation in all soil/ murrum /soft rock, sand cushioning, protective covering and refilling the pit etc. as required. |
| 51 | MPPWD SOR 2024 Sr. No. 41.12.1.9- G.I. pipe for protection of underground cable 100.00mm Supplying & installing G.I. pipe for protection of underground cable fixed on wall/support/in trench/fixed between two rigid existing support of wall/beam for erection of ceiling Fan/down rod for stiff pendent for light luminaries /fan/protective for earthing, lightening conductor down strip/overhead service line/for submersible cable or centrifugal pump for water supply with necessary iron clamp coupler, bend, tee, elbow, nuts and bolts etc. complete in an approved manner as required to complete excluding cost of excavation/dismantling & other finished masonry Item complete. |
| 52 | MPPWD SOR 2024 Sr. No. 13.1.1- MS Conduit 20mm (Power)H.G. conduit 20 mm, wall thickness 1.6mm Supplying and fixing rigid steel conduit ISI marked along with the accessories in concealed system including cutting the wall and plastering & repainting the wall with matching colour to bring in its original condition as required |
| 53 | MPPWD SOR 2024 Sr. No. 42.13.2-Water tight terminal box (M.S. Sheet) for street light pole 30x20x10 Cms. 4 Pole epoxy connector for Water tight terminal box, MCB/Connector mounting for Water tight terminal box Supplying and erection of water tight terminal box made of 16 SWG M.S. Sheet (1.6mm thick) i/c rubbergasket of required size suitable for kit kat/MCB/switch including 2 nos. pole clamp of M.S. flat iron size32x3mm, nut and bolts, The box shall be powder coated excluding the cost of the kit kat/MCB/Switch 4 Pole epoxy connector nut & bolt type, 30Amp, 500Volt complete as per specification as mentioned below. |
| 54 | MPPWD SOR 2024 Sr. No. 29.32-Analog time switch for automatic ON - OFF streetlight Supplying and fixing of analog time switch for automatic ON - OFF street light of approved make in existing LT panel including connections etc. as required as per specification |
| 55 | MPPWD SOR 2024 Sr. No. 37.1 -Earthing GI pipe earthing (40×4.5m) Earthing with G.I. earth pipe 4.5 metre long and 40 mm dia with masonry encloser incement mortar, cover plate having locking arrangement on the top etc. (but without charcoal or coke and salt) complete as required |
| 56 | MPPWD SOR 2024 Sr. No.37.2.1-Excavation 4.5m (manual) Excavation 4.5 m by manual labour |
| 57 | MPPWD SOR 2024 Sr. No.37.9-Supply and laying 25mm X 5mm G.I. stripat 0.5 metre below ground Supply and laying 25mm X 5mm G.I. strip at 0.5 metre below ground level as strip earth electrode including jointing etc. as required. |
| 58 | MPPWD SOR 2024 Sr. No.29.27-Main LT Panel (MDB) Supply, fixing, testing & commissioning wall/floor mounted LT panel primer coated with powder coated paint & provided with required gasket for dust/vermin proof with degree of protection IP42 suitable for 415Volt 3 phase, 50 Hz, 4 wire system fabricated out of CRCA sheet upto 2 mm thick (1.6 mm for doors) duly compartmentalized for incomer, bus section, outgoings, cable alleys & CT, PT Ampere Metre, Volt Metre, selector switches, frequency Metre, phase indicating lamp, Energy Metre complete including cost of busbar supports, detachable cable gland plates, 2 earthing terminals, internal wiring & fixing of separately supplied MCBs, MCCBs, ACB, panel mounted changeover switch/SFUs, etc. as required but excluding cost of busbar strips, Ampere Metre, Volt Metre, selector switch as per approved design & specification |
| 59 | MPPWD SOR 2024 Sr. No. 27.3.4- MCCB 200A, 25kA, 4P Supply of ISI marked and approved make of moulded case circuit breaker (MCCB) suitable for 3 phase,3 pole,50 Hz, 415 Volts, AC supply with respective interrupting capacity (KA) at 415 Volts cited against their range standard conforming to IS – 8828 |
| 60 | MPPWD SOR 2024 Sr. No. 25.6.10- Automatic transfer switches (ATS) 315A (with enclosure) Panel mounted changeover switch Supply of ISI Marked AutomaticTransfer Switches (ATS) confirming to IEC : 60947-1 & IEC : 60947-6-1 with automatic inbuilt time delay 4 pole, 415 V with two earthing terminals if required. |
| 61 | MPPWD SOR 2024 Sr. No. 29.28.1- Digital Ampere Metre Digital Ampere Metre with CTs with selector switch |
| 62 | MPPWD SOR 2024 Sr. No.29.28.2-Digital Volt Metre Digital Volt Metre with selector switch & HRC fuse |
| 63 | MPPWD SOR 2024 Sr. No. 29.28.3 Frequency Metre Frequency Metre |
| 64 | MPPWD SOR 2024 Sr. No. 29.28.4-Multifunction Meter |
| 65 | MPPWD SOR 2024 Sr. No. 29.28.5-Copper Bus Bar Strips Copper bus bar strips with PVC sleeves |
| 66 | MPPWD SOR 2024 Sr. No. 29.28.6-Aluminium Bus Bar Strips Aluminium bus bar strips with PVC sleeves |
| 67 | MPPWD SOR 2024 Sr. No. 29.28.7-LED lamp indicator |
| 68 | MPPWD SOR 2024 Sr. No. 27.23.2.1-Steel enclosure, neutral bar suitablefor 63Amp/100Amp, 3P/4P enclosure Supply & fixing of approved make accepted standard sheet steel enclosure (dust protected) duly powder coated paint neutral bar suitable for MCB/RCBOs/MCCB of capacity as required etc. complete as per specification (exclusive of M.C.B./ MCCB/RCBOs) |
| 69 | MPPWD SOR 2024 Sr. No. 27.3.2-125A incoming MCCB / Isolator 4 poleMCCB 25kA current rating - 125Amp & adjustable overload setting 80% -100% of In, adjustable short circuit setting 6-10 In 4 Pole Supplying of ISI marked and approved make of moulded case circuit breaker (MCCB) suitable for 3 phase & N, 4pole, 50 Hz, 415 Volts, (Ics=100%Icu) AC supply with thermal-magnetic release having respective breaking capacity (KA) at 415 Volts cited against their range standard conforming to IS/IEC 60947-2 |
| 70 | MPPWD SOR 2024 Sr. No. 27.21.2.8-RCCB / RCBO for leakage protection 4 Pole 63A, 100/300mA Supplying and installing of RCBOs (Residual current circuit breaker with overload and short circuit protection)ISI marked complete as per I.S. standard conforming to IEC:61009-1 & IS:12640-2, 240/415V 50 Hz with 10kA short circuit withstand capacity for earth leakage, overload & short circuit protection including connectionin existing enclosure in approved manner as per specification. |
| 71 | MPPWD SOR 2024 Sr. No. 27.23.2.1-Steel enclosure, neutral bar suitable for 63Amp/100Amp, 3P/4P enclosure Supply & fixing of approved make accepted standard sheet steel enclosure (dust protected) duly powder coated paint neutral bar suitable for MCB/RCBOs/MCCB of capacity as required etc. complete as per specification (exclusive of M.C.B./ MCCB/RCBOs) |
| 72 | MPPWD SOR 2024 Sr. No. 27.3.2- 125A incoming MCCB / Isolator 4 poleMCCB 25kA current rating - 125Amp & adjustableoverload setting 80% -100% of In, adjustable shortcircuit setting 6-10 In 4 Pole Supplying of ISI marked and approved make of moulded case circuit breaker (MCCB) suitable for 3 phase & N, 4pole, 50 Hz, 415 Volts, (Ics=100%Icu) AC supply with thermal-magnetic release having respective breakingcapacity (KA) at 415 Volts cited against their range standard conforming to IS/IEC 60947-2 |
| 73 | MPPWD SOR 2024 Sr. No. 27.21.2.8- RCCB / RCBO for leakage protection 4 Pole 63A, 100/300mA Supplying and installing of RCBOs (Residual current circuit breaker with overload and short circuit protection)ISI marked complete as per I.S. standard conforming to IEC:61009-1 & IS:12640-2, 240/415V 50 Hz with 10 kA short circuit withstand capacity for earth leakage, overload & short circuit protection including connection in existing enclosure in approved manner as per specification. |
| 74 | MPPWD SOR 2024 Sr. No. 27.22.8- SPDs, (surge protection device) ground floorType 1+2, 100kA, 3P+N (MDB) Supplying and installing of SPDs (surge protection device) ISI marked complete as per I.S. standard conforming to IEC:61543 - 11 for direct & indirect lightning surges protection type 2 maximum discharge current (Imax) up to 70kA &type 1+2 (Imax) up to 100KA including connection in existing enclosure in approved manner as per specification. |
| 75 | MPPWD SOR 2024 Sr. No. 27.22.4-SPDs, (surge protection device) First floorType 2, 70kA, 3P+N (PDB) Supplying and installing of SPDs (surge protection device) ISI marked complete as per I.S. standard conforming to IEC:61543 - 11 for direct & indirect lightning surges protection type 2 maximum discharge current (Imax) up to 70kA &type 1+2 (Imax) up to 100KA including connection in existing enclosure inapproved manner as per specification. |
| 76 | MPPWD SOR 2024 Sr. No. 27.22.2-SPDs, (surge protection device) second floorType 2, 70kA, 1P+N Supplying and installing of SPDs (surge protection device) ISI marked complete as per I.S. standard conforming to IEC:61543 - 11 for direct & indirect lightning surges protection type 2 maximum dischargecurrent (Imax) up to 70kA &type 1+2 (Imax) up to 100KA including connection in existing enclosure in approved manner as per specification. |
| 77 | MPPWD SOR 2024 Sr. No. 38.2.1-Telephone Wire 0.5 mm – 1 PairPVC insulated cu. Conductor Supplying and drawing following pair, 0.5 mm PVC insulated copper conductor unarmoured telephone cable in existing surface/concealed, steel/PVC conduit as required. |
| 78 | MPPWD SOR 2024 Sr. No. 38.4.1-Telephone Tag Block – 20 Pair Supply, installation testing and commissioning of telephone tag block krone connector with enclosure. |
| 79 | Non SOR - KITCHEN CHIMNEY 90cm Supply, installation testing and commissioning of kitchen chimney, 1500 m3/hr BLDC atoclean chimney with full grill. |
| 80 | MPPWD SOR 2024 Sr. No. 38.17.3-12U Wall Mount Rack Networking Supply, installation testing and commissioning of wall mounting rack, for computer switches/Patch Panel etc complete as mentioned .12U cabinet with min. Dimension 590X600X600, wall mounting with 6 point 5 Amp. socket power supply strip, and fan, cable manager, tray as per Site requirement. |
| 81 | Non SOR - WI-FI ROUTER Business-grade Gigabit VPN Router with 5 Gigabit ports (1 WAN + 2 WAN/LAN + 2 LAN), multi-WAN load balancing & USB WAN backup, VLAN/firewall/IP-MAC/URL filtering, 20 IPsec + 16 OpenVPN/L2TP/PPTP tunnels. |
| 82 | Non SOR - WI-FI Access Point Dual-band Wi-Fi 6 (802.11ax) Access Point with up to 1775 Mbps (574 Mbps @2.4 GHz + 1201 Mbps @5 GHz), PoE+ Gigabit port, OFDMA + MU-MIMO, seamless roaming, Omada cloud/app management, up to ~250+ clients & 16 SSIDs (guest VLAN) support for enterprise-grade hotel Wi-Fi deployment |
| 83 | MPPWD SOR 2024 Sr. No. 57.10.2 - Interactive display panel with video conference 75 Inch Supply, installation, testing and commissioning of Interactive Panel having Resolution 3840(H) ×2160 (V), Display Color 1.07Billon Colors, Min. Brightness 400cd/m2, LCD (with LED backlit), View Angle R/L 178 (Min.), U/D 178 (Min.), speaker output 20W × 2, HDMI Input 2, HDMI Output 1, Multi-Media USB 4 (2 Front 3.0,1x3.0 rear, 1x2.0 rear), RS232 - 01, RJ-45-Yes(LAN) / Ethernet, Touch input 02, Bluetooth BT 5.0, WIFI 6, VGA In 1, Line Out 1, MIC 1, DP 1.2 1, Cover Glass anti glare 9 Mohs, Touch Resolution\ 32768x32768, Touch Accuracy 1mm, having Annotation Over Any Source, Response Time <5ms, having Palm Detection, Pen and Touch Differentiation, Touch - 20 points (Drawing, Annotation, Painting,Eraser, Highlighter, PDF Viewer, PPT Viewer, Browser, Movies & Image Viewer, External Source annotation), Files like PDF or objects can be saved in a private folder, 4 Drawing through split screens / Export and Import of files from mails / pen-drive or internet / Multimedia feature, Compatibility Windows 11/ Linux/Android /Chrome, OS Version ANDROID 11.0 , Processor A55 Quadcore 1.55Ghz, Flash 32 GB EMMC5, RAM 4 GB DDR4 or equivalent latest software version and specification, having accessories- User manual, wireless key board and mouse, remote control, power cable,touch cables, HDMI cable, Touch pens (2 stylus, 1 extendable),VESA Standard (Wall mount) / 3 Year warranty. |
| 84 | Non SOR - Fire Extinguishers capacity 4.5 kg bearing ISI marked and IS 15683 completely charged, upright type, operating valve wheel operated ISI mark and high pressure tested hose pipe with discharge horn. Minimum Discharge time: 10-25 Sec; Empty weight (approx): 11.5-12.5 kg.Gross weight (approx): 17 KGWorking pressure: 60 kg/cm2Hydraulic test pressure: 250 kg/cm2Burst pressure : 600 kg/cm2 |
| 85 | Non SOR - Fire Extinguishers , ABC type DCP FIRE EXTINGUISER Fire Extinguishers 6 kg capacity with squeeze grip G.M. chromium plated cap, high pressure discharge tube with PVC wide horn completely charged (CO2 gas cartridge ISI mark and ABC powder ISI mark 60% MAP) bearing ISI marked and IS 15683 mark. |
| 86 | Non SOR - Mechanical Foam Fire Extinguishers Mechanical Foam Fire Extinguishers 9 litre capacity with squeeze grip G.M. chromium plated cap, high pressure discharge tube with foam nozzle completely charged CO2 gas cartridge (ISI mark) internally anti corrosive treated, extinguisher bearing ISI marked and IS 15683 mark |
| 87 | MPPWD SOR 2024 Sr. No. 50.1.3-Fire panel 8 zone Fire panel : Providing, fixing, testing & commissioning microprocessor based main fire alarm panel and indicating panel solid state modular card type pulsar, timer for dual stage alarm facility with indicators, standby battery ,complies to IS 2189:1999.2 x 16 character backlit LCD display lamp test features. Complete with integral power supply and battery charger for SMF battery. NO/NC contacts for both fire and fault. Switches to enable on board operation. LCD and LED Indication for open, short circuit, Isolate, fire in each zone. reset, lamp test, silence, isolate, short, open, fire continuous buzzer for fault and intermittent buzzer for fire battery charger box, operating voltage 220 Volt mains A.C. input/24V D.C. output etc. complete in all respect. |
| 88 | MPPWD SOR 2024 Sr. No. 50.2 -Smoke Detector (ionization type) Smoke detector (ionization type) : Providing & fixing of ionization type smoke detectors as per IS: 11360-1985 of dual chamber, 12/24 volt DC, ionization source-less than one micro curie. |
| 89 | MPPWD SOR 2024 Sr. No. 50.7 - Manual call point Manual call point: Providing & fixing of manual calls point flush or surface mounting. Front protection glass cover. Unbreakable glass ABS plastic body. |
| 90 | MPPWD SOR 2024 Sr. No. 50.8 -Internal hooter sound output 120 DB, Internal hooter: Providing & fixing of internal hooter with working AC Voltage 220V A.C./24V D.C. current consumption, sound output 120 DB, material M.S. sheet. |
| 91 | MPPWD SOR 2024 Sr. No. 41.1.4.1-Fire Alarm Cable (FRLSH) 2.5 sq. mm. 2‑core Armoured Fire Retardant, Low Smoke / Halogen-free Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, /2 core ISI marked with alu. stranded /solid conductor. |
| 92 | MPPWD SOR 2024 Sr. No. 47.4.2- Inverter 1-1.05 KVA Supply, installation, testing and commissioning of Pure sine wave Inverter , Display Indications (Status, Fault conditions and Battery Charging) ,Standard Voltage range from 100 V~ 300 V , High Peak Current Handling Capability & High Voltage Surge Protection excluding battery and wiring for connections. |
| 93 | MPPWD SOR 2024 Sr. No.1.1.3- Inverter Socket 6A, 3-Pin sep. board Long point Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid steel conduit ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit including painting, screwless connector for joints etc. as required as per specification. |
| 94 | MPPWD SOR 2024 Sr. No.2.1.3.3-Inverter 3-Module Metal Box (Inverter Supply) Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. |
| 95 | MPPWD SOR 2024 Sr. No.19.1.3.1-Single Core PVC Cable 1×4 sqmm (Inverter) Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification. |
| 96 | MPPWD SOR 2024 Sr. No.47.5.3- Battery – 180/200 AH, Tall Tubular Supply, installation, testing and commissioning of 12/24 V Battery system in series/parallel combinations or as single as per requirement including interconnetion wiring, lugs and other required material as required with maunting stand/trolley, warranty period: Minimum 3 year |
| 97 | Work contract for construction of New rest house along with electrification work including supply of electrical material at ATPS, MPPGCL, CHACHAI. ( Percentage Rate should be quated excluding GST) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 6 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender