Power Government Departments Closing in 16 days TDR #57867936

Tender For Construction Of 220Kv D/C Gangapur City -Bhadoti (Proposed 220Kv Gss) Line (Approx. Length -50 Km ) On Turnkey Basis Under Bid Enquiry No. - 9018002537

Issued by Government Departments · Jaipur, Rajasthan
Tender Value
51.45 Crore
Estimated cost
Bid Submission
03 Nov 2026
16 days left
EMD
1.02 Crore
Bank guarantee accepted
Document Fee
23600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of 220Kv D/C Gangapur City -Bhadoti (Proposed 220Kv Gss) Line (Approx. Length -50 Km ) On Turnkey Basis Under Bid Enquiry No. - 9018002537

BOQ

Name of Work:- Construction of 220KV D/C Gangapur City -Bhadoti (Proposed 220KV GSS) line (Approx. length -50 KM ) on Turnkey basis under Bid Enquiry No. - 9018002537
Sl. No. Item Description
1Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc.
2High Tensile Steel
3Mild Steel
4Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts and anti theft bolts & nuts, Spring Washers Etc. )
5Supply of Earthing material of Towers
6Pipe Type Set
7Counter Poise Earthing set
8Supply of following Tower Accessories
9Danger Plate
10Number Plate
11Phase Plate (Set of three)
12Design, manufacture and supply of following line material.
13Disc Insulator - 70 kN
14Disc Insulator - 120 kN
15Hardware Fittings for ACSR Zebra Conductor
16Single Suspension H/W fittings for ACSR Zebra Conductor
17Single Tension H/W fittings for ACSR Zebra Conductor
18Double Suspension H/W fittings for ACSR Zebra Conductor
19Double Tension H/W fittings for ACSR Zebra Conductor
20Accessories for ACSR Zebra Conductor
21Mid Span Compression Joint for ACSR Zebra Conductor
22Repair Sleeve for ACSR Zebra Conductor
23Preformed Armour Rod for ACSR Zebra Conductor
24Vibration Damper for ACSR Zebra Conductor
25OPGW Cable
2648 Fibre (DWSM) OPGW fibre optic cable
27Installation Hardware set for 48 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except joint box
28Joint box (48 fibre)
29FODP 48F: Indoor Type, rack mounted with FCPC coupling and pigtails
30FODP 96F: Indoor Type, rack mounted with FCPC coupling and pigtails
31Any Other item required for successful completion of work
32Note: * Quantity indicated is for evaluation purpose. Actual quantity to be supplied after getting approval. ++One set of installation hardware shall contain all installation hardware fittings as may be required for 1 km of OPGW/Approach Fibre Optic cable.
33Detail Survey as per tentative route-Which includes the following major activities-Pegging of line route, providing of survey pillar at an interval of 3-4 KM in the line route with required jungle clearance for survey, profile preparation of approved route on graph sheet and marking of offset on either side of line, marking of side clearance for hills, sand dunes etc, as per specification and tower scheduling.
34Check survey as per approved route of line which includes-Re-checking of the line route as per approved profile, chainage, tower center marking, pit marking, bisection of angle tower as required at site.
35Excavation-Excavation, excluding back filling, including shoring,shuttering, dewatering, etc. upto the required depth as per foundation specification/drawings.
36(i) Any soil, soft rock other than hard rock
37(ii) Hard Rock (with blasting subject to permission or without blasting)
38SETTING OF TEMPLATE & STUB/ANCHOR BOLT:-Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming andwatering as per specification.
39(i) Tower including extension upto 9 Meter
40(ii) Special Towers for any span including extension upto 9 Meter
41CONCRETING: Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size,water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings.
42(i) 1:4:8 Mix
43(ii) 1:3:6 Mix
44(iii) 1:2:4 Mix
45(iv) 1:1.5:3 Mix
46STEEL REINFORCEMENT: Cutting, bending, welding of joints if required,fixing and placing of steel reinforcement as per specification and drawings including material.
47EARTHING:
48(A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation,augering and backfilling in all types of soil.
49(B) Earthing of towers legs with counterpoise typeearthings excluding supply of materialsbut including excavation and backfilling in all types of soil.(i)each set by laying 4 wires each 15m long at a depth of 600mm .
50ERECTION OF TOWERS: Erection of super structures including D-shackles,ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint
51Erection of tower (with extension upto 9 Meters)
52Erection of special tower (with extension)
53CONDUCTOR STRINGING: Stringing of ACSR Zebra including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line.
54(i) Single Conductor
55(ii) Single Conductor for river
56CONDUCTOR STRINGING: Stringing of ACSR Panther including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line.
57(ii) Single Conductor for river
58RIVETMENT OF TOWERS
59(A) Providing and laying cement concrete including curing, compaction etc. complete using stone aggregate 40 mm nominal size (crusher broken) in foundation plinth, using 1 Cement: 5 Sand: 10 aggregate mix.
60(B) Random rubble stone masonary for rivetment in 1:5 cement sand mortar including providing and fixing 100mm dia PCC drain pipe & raised and cut-pointing on stone masonary in 1:3 cement sand mortar excluding excavation but including Back filling inside rivetment using excavated/ borrowed earth (with all lead & lift) in layers not exceeding 20cm in depth & consolidating each deposited layer by ramming and watering.
61(C) Random rubble dry stone pitching including preparing surface etc. complete with raised & cut pointing in cement sand mortar 1:3 curing etc.
62(D) Cement concrete coping grade 1:2:4 (1cement: 2coarse sand :4 graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of steps etc. complete for 75mm thick with 20mm thick nominal size aggregate
63Installation of OPGW
64Stringing of 48 Fiber (DWSM) OPGW Fibre Optic Cable
65Installation Hardware set for above 48Fibre OPGW cabling including of all cable fittings and accessories except joint box
66Joint box (48 Fiber) OPGW Cable
67FODP 48F : Indoor Type, rack mounted with FCPC coupling and pigtails
68FODP 96F : Indoor Type, rack mounted with FCPC coupling and pigtails
69Land Identification and Compensation
70For Scope of work as specified at item no. a(I to iv) in Annexure-A (Enclosed)
71For Scope of work as specified at item no. a(I to iv) in Annexure-A (Enclosed)
72Any Other Item
73Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc.
74High Tensile Steel
75Mild Steel
76Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts and anti theft bolts & nuts, Spring Washers Etc. )
77Supply of Earthing material of Towers
78Pipe Type Set
79Supply of following Tower Accessories
80Danger Plate
81Number Plate
82Phase Plate (Set of three)
83Design, manufacture and supply of following line material.
84Disc Insulator - 70 kN
85Disc Insulator - 120 kN
86Porcelain Long Rod Insulators - 120kN
87Hardware Fittings for ACSR Zebra Conductor
88Single Suspension H/W fittings for ACSR Zebra Conductor
89Single Tension H/W fittings for ACSR Zebra Conductor
90Double Tension H/W fittings for ACSR Zebra Conductor
91Accessories for ACSR Zebra Conductor
92Mid Span Compression Joint for ACSR Zebra Conductor
93Repair Sleeve for ACSR Zebra Conductor
94Vibration Damper for ACSR Zebra Conductor
95G.I. Earth wire 7/3.15
96Strain Assembly for Earth wire 7/3.15 with copper earth Bond
97Suspension Assembly for Earth wire 7/3.15 with copper earth bond
98Vibration Damper for Earth wire 7/3.15
99OPGW Cable
10048 Fibre (DWSM) OPGW fibre optic cable
101Installation Hardware set for 48 Fibre OPGW Fibre optic cabling including all cable fittings & accessories except joint fox
102Joint box (48Fibre)
103Any Other item required for successful completion of work
104Note: * Quantity indicated is for evaluation purpose. Actual quantity to be supplied after getting approval. ++One set of installation hardware shall contain all installation hardware fittings as may be required for 1 km of OPGW/Approach Fibre Optic cable.
105Detail Survey as per tentative route-Which includes the following major activities-Pegging of line route, providing of survey pillar at an interval of 3-4 KM in the line route with required jungle clearance for survey, profile preparation of approved route on graph sheet and marking of offset on either side of line, marking of side clearance for hills, sand dunes etc, as per specification and tower scheduling.
106Check survey as per approved route of line which includes-Re-checking of the line route as per approved profile, chainage, tower center marking, pit marking, bisection of angle tower as required at site.
107Excavation-Excavation, excluding back filling, including shoring,shuttering, dewatering, etc. upto the required depth as per foundation specification/drawings.
108(i) Any soil, soft rock other than hard rock
109(ii) Hard Rock (with blasting subject to permission or without blasting)
110SETTING OF TEMPLATE & STUB/ANCHOR BOLT:-Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming andwatering as per specification.
111(i) Tower including extension upto 9 Meter
112CONCRETING: Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size,water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings.
113(i) 1:4:8 Mix
114(ii) 1:3:6 Mix
115(iii) 1:2:4 Mix
116(iv) 1:1.5:3 Mix
117STEEL REINFORCEMENT: Cutting, bending, welding of joints if required,fixing and placing of steel reinforcement as per specification and drawings including material.
118EARTHING:
119(A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation,augering and backfilling in all types of soil.
120ERECTION OF TOWERS: Erection of super structures including D-shackles,ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint
121Erection of tower (with extension upto 9 Meters)
122CONDUCTOR STRINGING: Stringing of ACSR Zebra including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line.
123(i) Single Conductor
124EarthwireStringing :- (A) Stringing of galvanised steel stranded wire including laying,jointing & tensioning, clamping,clipping and fixing vibration damper and earth bond etc.
125(i)One No. 7/3.15 mm galvanised wire
126RIVETMENT OF TOWERS
127(A) Providing and laying cement concrete including curing, compaction etc. complete using stone aggregate 40 mm nominal size (crusher broken) in foundation plinth, using 1 Cement: 5 Sand: 10 aggregate mix.
128(B) Random rubble stone masonary for rivetment in 1:5 cement sand mortar including providing and fixing 100mm dia PCC drain pipe & raised and cut-pointing on stone masonary in 1:3 cement sand mortar excluding excavation but including Back filling inside rivetment using excavated/ borrowed earth (with all lead & lift) in layers not exceeding 20cm in depth & consolidating each deposited layer by ramming and watering.
129(C) Random rubble dry stone pitching including preparing surface etc. complete with raised & cut pointing in cement sand mortar 1:3 curing etc.
130(D) Cement concrete coping grade 1:2:4 (1cement: 2coarse sand :4 graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of steps etc. complete for 75mm thick with 20mm thick nominal size aggregate
131Installation of OPGW
132Stringing of 48 Fiber (DWSM) OPGW Fibre Optic Cable
133Installation Hardware set for above 48Fibre OPGW cabling including of all cable fittings and accessories except joint box
134Joint box (48 Fiber) OPGW Cable
135Re-Stringing of 24 Fibre (DWSM) OPGW Fibre Optic cable, re-installation of hardware set for 24 fibre OPGW Fibre optic cabling including all cable fittings and accessories except joint box
136Re-Stringing of 24 Fibre (DWSM) OPGW Fibre Optic cable, re-installation of 24 fibre OPGW optic cabling including all cable fittings and accessories except joint box
137Land identification and compensation
138For Scope of work as specified at item no. a(I to iv) in Annexure-A (Enclosed)
139For Scope of work as specified at item no. a(I to iv) in Annexure-A (Enclosed)
140Any Other Item
141Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc.
142High Tensile Steel
143Mild Steel
144Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts and anti theft bolts & nuts, Spring Washers Etc. )
145Supply of Earthing material of Towers
146Pipe Type Set
147Supply of following Tower Accessories
148Danger Plate
149Number Plate
150Phase Plate (Set of three)
151Design, manufacture and supply of following line material.
152(i)Disc Insulator - 70 kN
153(i)Disc Insulator - 120 kN
154Hardware Fittings for ACSR Panther Conductor
155Single Suspension H/W fittings for ACSR Panther Conductor
156Single Tension H/W fittings for ACSR Panther Conductor
157Double Suspension H/W fittings for ACSR Panther Conductor
158Double Tension H/W fittings for ACSR Panther Conductor
159Accessories for ACSR Panther Conductor
160Mid Span Compression Joint for ACSR Panther Conductor
161Repair Sleeve for ACSR Panther Conductor
162Preformed Armour Rod for ACSR Panther Conductor
163Vibration Damper for ACSR Panther Conductor
164OPGW Cable
16524 Fibre (DWSM) OPGW fibre optic cable
166Installation Hardware set for 24 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except joint box
167Joint box (24Fibre)
168FODP 48F: Indoor Type, rack mounted with FCPC coupling and pigtails
169Any Other item required for successful completion of work
170Note: * Quantity indicated is for evaluation purpose. Actual quantity to be supplied after getting approval. ++One set of installation hardware shall contain all installation hardware fittings as may be required for 1 km of OPGW/Approach Fibre Optic cable.
171Detail Survey as per tentative route-Which includes the following major activities-Pegging of line route, providing of survey pillar at an interval of 3-4 KM in the line route with required jungle clearance for survey, profile preparation of approved route on graph sheet and marking of offset on either side of line, marking of side clearance for hills, sand dunes etc, as per specification and tower scheduling.
172Check survey as per approved route of line which includes-Re-checking of the line route as per approved profile, chainage, tower center marking, pit marking, bisection of angle tower as required at site.
173Excavation-Excavation, excluding back filling, including shoring,shuttering, dewatering, etc. upto the required depth as per foundation specification/drawings.
174(i) Any soil, soft rock other than hard rock
175(ii) Hard Rock (with blasting subject to permission or without blasting)
176SETTING OF TEMPLATE & STUB/ANCHOR BOLT:-Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming andwatering as per specification.
177(i) Tower including extension upto 9 Meter
178CONCRETING: Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size,water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings.
179(i) 1:4:8 Mix
180(ii) 1:3:6 Mix
181(iii) 1:2:4 Mix
182(iv) 1:1.5:3 Mix
183STEEL REINFORCEMENT: Cutting, bending, welding of joints if required,fixing and placing of steel reinforcement as per specification and drawings including material.
184EARTHING:
185(A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation,augering and backfilling in all types of soil.
186ERECTION OF TOWERS: Erection of super structures including D-shackles,ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint
187Erection of tower (with extension upto 9 Meters)
188CONDUCTOR STRINGING: Stringing of ACSR Panther including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line.
189(i) Single Conductor
190(i) Single Conductor for river
191RIVETMENT OF TOWERS
192(A) Providing and laying cement concrete including curing, compaction etc. complete using stone aggregate 40 mm nominal size (crusher broken) in foundation plinth, using 1 Cement: 5 Sand: 10 aggregate mix.
193(B) Random rubble stone masonary for rivetment in 1:5 cement sand mortar including providing and fixing 100mm dia PCC drain pipe & raised and cut-pointing on stone masonary in 1:3 cement sand mortar excluding excavation but including Back filling inside rivetment using excavated/ borrowed earth (with all lead & lift) in layers not exceeding 20cm in depth & consolidating each deposited layer by ramming and watering.
194(C) Random rubble dry stone pitching including preparing surface etc. complete with raised & cut pointing in cement sand mortar 1:3 curing etc.
195(D) Cement concrete coping grade 1:2:4 (1cement: 2coarse sand :4 graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of steps etc. complete for 75mm thick with 20mm thick nominal size aggregate
196Installation of OPGW
197Stringing of 24 Fiber (DWSM) OPGW FIBRE OPTIC CABLE
198Installation Hardware set for above 24 Fibre OPGW cabling including of al cable fittings and accessories exept joint Box
199JOINT BOX (24 FIBER) OPGW CABLE
200FODP 48F : Indoor Type, rack mounted with FCPC coupling and pigtails
201Land identification and compensation
202For Scope of work as specified at item no. a(I to iv) in Annexure-A (Enclosed)
203For Scope of work as specified at item no. a(I to iv) in Annexure-A (Enclosed)
204Any Other Item
205Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc.
206High Tensile Steel
207Mild Steel
208Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts and anti theft bolts & nuts, Spring Washers Etc. )
209Sub Station Structures All type
210Supply of Earthing material of Towers
211Pipe Type Set
212Supply of following Tower Accessories
213Danger Plate
214Number Plate
215Phase Plate (Set of three)
216Design, manufacture and supply of following line material.
217(i)Disc Insulator - 70 kN
218(i)Disc Insulator - 120 kN
219Hardware Fittings for ACSR Panther Conductor
220Single Suspension H/W fittings for ACSR Panther Conductor
221Single Tension H/W fittings for ACSR Panther Conductor
222Double Suspension H/W fittings for ACSR Panther Conductor
223Double Tension H/W fittings for ACSR Panther Conductor
224Accessories for ACSR Panther Conductor
225Mid Span Compression Joint for ACSR Panther Conductor
226Repair Sleeve for ACSR Panther Conductor
227Preformed Armour Rod for ACSR Panther Conductor
228Vibration Damper for ACSR Panther Conductor
229OPGW Cable
23048 Fibre (DWSM) OPGW fibre optic cable
231Installation Hardware set for 48 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except joint box
232Joint box (48Fibre)
233FODP 48F: Indoor Type, rack mounted with FCPC coupling and pigtails
234Any Other item required for successful completion of work
235Note: * Quantity indicated is for evaluation purpose. Actual quantity to be supplied after getting approval. ++One set of installation hardware shall contain all installation hardware fittings as may be required for 1 km of OPGW/Approach Fibre Optic cable.
236Detail Survey as per tentative route-Which includes the following major activities-Pegging of line route, providing of survey pillar at an interval of 3-4 KM in the line route with required jungle clearance for survey, profile preparation of approved route on graph sheet and marking of offset on either side of line, marking of side clearance for hills, sand dunes etc, as per specification and tower scheduling.
237Check survey as per approved route of line which includes-Re-checking of the line route as per approved profile, chainage, tower center marking, pit marking, bisection of angle tower as required at site.
238Excavation-Excavation, excluding back filling, including shoring,shuttering, dewatering, etc. upto the required depth as per foundation specification/drawings.
239(i) Any soil, soft rock other than hard rock
240(ii) Hard Rock (with blasting subject to permission or without blasting)
241SETTING OF TEMPLATE & STUB/ANCHOR BOLT:-Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming andwatering as per specification.
242(i) Tower including extension upto 9 Meter
243CONCRETING: Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size,water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings.
244(i) 1:4:8 Mix
245(ii) 1:3:6 Mix
246(iii) 1:2:4 Mix
247(iv) 1:1.5:3 Mix
248STEEL REINFORCEMENT: Cutting, bending, welding of joints if required,fixing and placing of steel reinforcement as per specification and drawings including material.
249EARTHING:
250(A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation,augering and backfilling in all types of soil.
251ERECTION OF TOWERS: Erection of super structures including D-shackles,ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint
252Erection of tower (with extension upto 9 Meters)
253ERECTION OF SUB STATION STRCTURES: Erection of substation structures including leveling, setting of stub & Tighting, Punching of Nuts& Bolts and tack welding upto beam level as per specification.
254CONDUCTOR STRINGING: Stringing of ACSR Panther including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line.
255(i) Single Conductor
256RIVETMENT OF TOWERS
257(A) Providing and laying cement concrete including curing, compaction etc. complete using stone aggregate 40 mm nominal size (crusher broken) in foundation plinth, using 1 Cement: 5 Sand: 10 aggregate mix.
258(B) Random rubble stone masonary for rivetment in 1:5 cement sand mortar including providing and fixing 100mm dia PCC drain pipe & raised and cut-pointing on stone masonary in 1:3 cement sand mortar excluding excavation but including Back filling inside rivetment using excavated/ borrowed earth (with all lead & lift) in layers not exceeding 20cm in depth & consolidating each deposited layer by ramming and watering.
259(C) Random rubble dry stone pitching including preparing surface etc. complete with raised & cut pointing in cement sand mortar 1:3 curing etc.
260(D) Cement concrete coping grade 1:2:4 (1cement: 2coarse sand :4 graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of steps etc. complete for 75mm thick with 20mm thick nominal size aggregate
261Installation of OPGW
262Stringing of 48 Fiber (DWSM) OPGW FIBRE OPTIC CABLE
263Installation Hardware set for above 48Fibre OPGW cabling including of al cable fittings and accessories exept joint Box
264JOINT BOX (48 FIBER) OPGW CABLE
265FODP 48F : Indoor Type, rack mounted with FCPC coupling and pigtails
266Re-Stringing of 24 Fibre (DWSM) OPGW Fibre Optic cable, re-installation of hardware set for 24 fibre OPGW Fibre optic cabling including all cable fittings and accessories except joint box
267Restringing of conductor/Earthwire
268A.) Restringing of ACSR Panther conductor: Dismentalling of vibration dampers, Armour Rods fitting of rollers, de-tensioning, holding and lowering of conductor, rehoisting of insulator string as required, adding/removing and jointing of conductor, hoisting of insulator string, lifting of conductor rollers and retensioning, jointing, fitting of armour rods and vibration damper and clamping per route KM of the line section to be restrung dismenatalled material notreused to be deposited in our stores and stacked
269i. Any Single Conductor
270Dismentalling of Towers:- Dismentalling of superstructures along with extensions, having tack welded bolts and nuts including removing of D-shackles, Hnagers, U-Bolts, Step Bolts, ACD, Danger Plate, Phase plate, Number Plate of the tower including transportation from site to our store and stacking of all material.
271A.) 132KV & 220KV S/C & D/C Towers all types
272Restringing of 24FIBER DWSM OPGW fibre optic cable reinstallation of 24 F OPGW optic cabling including all cable fitting and accessories except joint box.
273Land identification and compensation
274For Scope of work as specified at item no. a(I to iv) in Annexure-A (Enclosed)
275For Scope of work as specified at item no. a(I to iv) in Annexure-A (Enclosed)
276Any Other Item
277Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc.
278High Tensile Steel
279Mild Steel
280Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts and anti theft bolts & nuts, Spring Washers Etc. )
281Supply of Earthing material of Towers
282Pipe Type Set
283Supply of following Tower Accessories
284Danger Plate
285Number Plate
286Phase Plate (Set of three)
287Design, manufacture and supply of following line material.
288(i)Disc Insulator - 70 kN
289(i)Disc Insulator - 120 kN
290Hardware Fittings for ACSR Panther Conductor
291Single Suspension H/W fittings for ACSR Panther Conductor
292Single Tension H/W fittings for ACSR Panther Conductor
293Double Suspension H/W fittings for ACSR Panther Conductor
294Double Tension H/W fittings for ACSR Panther Conductor
295Accessories for ACSR Panther Conductor
296Mid Span Compression Joint for ACSR Panther Conductor
297Repair Sleeve for ACSR Panther Conductor
298Preformed Armour Rod for ACSR Panther Conductor
299Vibration Damper for ACSR Panther Conductor
300OPGW Cable
30148 Fibre (DWSM) OPGW fibre optic cable
302Installation Hardware set for 48 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except joint box
303Joint box (48Fibre)
304Any Other item required for successful completion of work
305Note: * Quantity indicated is for evaluation purpose. Actual quantity to be supplied after getting approval. ++One set of installation hardware shall contain all installation hardware fittings as may be required for 1 km of OPGW/Approach Fibre Optic cable.
306Detail Survey as per tentative route-Which includes the following major activities-Pegging of line route, providing of survey pillar at an interval of 3-4 KM in the line route with required jungle clearance for survey, profile preparation of approved route on graph sheet and marking of offset on either side of line, marking of side clearance for hills, sand dunes etc, as per specification and tower scheduling.
307Check survey as per approved route of line which includes-Re-checking of the line route as per approved profile, chainage, tower center marking, pit marking, bisection of angle tower as required at site.
308Excavation-Excavation, excluding back filling, including shoring,shuttering, dewatering, etc. upto the required depth as per foundation specification/drawings.
309(i) Any soil, soft rock other than hard rock
310(ii) Hard Rock (with blasting subject to permission or without blasting)
311SETTING OF TEMPLATE & STUB/ANCHOR BOLT:-Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming andwatering as per specification.
312(i) Tower including extension upto 9 Meter
313CONCRETING: Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size,water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings.
314(i) 1:4:8 Mix
315(ii) 1:3:6 Mix
316(iii) 1:2:4 Mix
317(iv) 1:1.5:3 Mix
318STEEL REINFORCEMENT: Cutting, bending, welding of joints if required,fixing and placing of steel reinforcement as per specification and drawings including material.
319EARTHING:
320(A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation,augering and backfilling in all types of soil.
321ERECTION OF TOWERS: Erection of super structures including D-shackles,ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint
322Erection of tower (with extension upto 9 Meters)
323CONDUCTOR STRINGING: Stringing of ACSR Panther including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line.
324(i) Single Conductor
325RIVETMENT OF TOWERS
326(A) Providing and laying cement concrete including curing, compaction etc. complete using stone aggregate 40 mm nominal size (crusher broken) in foundation plinth, using 1 Cement: 5 Sand: 10 aggregate mix.
327(B) Random rubble stone masonary for rivetment in 1:5 cement sand mortar including providing and fixing 100mm dia PCC drain pipe & raised and cut-pointing on stone masonary in 1:3 cement sand mortar excluding excavation but including Back filling inside rivetment using excavated/ borrowed earth (with all lead & lift) in layers not exceeding 20cm in depth & consolidating each deposited layer by ramming and watering.
328(C) Random rubble dry stone pitching including preparing surface etc. complete with raised & cut pointing in cement sand mortar 1:3 curing etc.
329(D) Cement concrete coping grade 1:2:4 (1cement: 2coarse sand :4 graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of steps etc. complete for 75mm thick with 20mm thick nominal size aggregate
330Installation of OPGW
331Stringing of 48 Fiber (DWSM) OPGW FIBRE OPTIC CABLE
332Installation Hardware set for above 48Fibre OPGW cabling including of al cable fittings and accessories exept joint Box
333JOINT BOX (48 FIBER) OPGW CABLE
334Restringing of 24FIBER DWSM OPGW fibre optic cable reinstallation of hardware set for 24 F OPGW optic cabling including all cable fitting and accessories except joint box.
335Restringing of conductor/Earthwire
336A.) Restringing of ACSR Panther conductor: Dismentalling of vibration dampers, Armour Rods fitting of rollers, de-tensioning, holding and lowering of conductor, rehoisting of insulator string as required, adding/removing and jointing of conductor, hoisting of insulator string, lifting of conductor rollers and retensioning, jointing, fitting of armour rods and vibration damper and clamping per route KM of the line section to be restrung dismenatalled material notreused to be deposited in our stores and stacked
337i. Any Single Conductor
338Dismentalling of Towers:- Dismentalling of superstructures along with extensions, having tack welded bolts and nuts including removing of D-shackles, Hnagers, U-Bolts, Step Bolts, ACD, Danger Plate, Phase plate, Number Plate of the tower including transportation from site to our store and stacking of all material.
339A.) 132KV & 220KV S/C & D/C Towers all types
340Restringing of 24FIBER DWSM OPGW fibre optic cable reinstallation of 24 F OPGW optic cabling including all cable fitting and accessories except joint box.
341Land identification and compensation
342For Scope of work as specified at item no. a(I to iv) in Annexure-A (Enclosed)
343For Scope of work as specified at item no. a(I to iv) in Annexure-A (Enclosed)
344Any Other Item Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57867936
AUTHORITY Government Departments
TENDER VALUE 51.45 Crore
LAST DATE 03-11-2026
Authority
Authority Name Rajasthan Rajya Vidhyut Prasaran Nigam Limited
Work Description Tender for Construction Of 220Kv D/C Gangapur City -Bhadoti (Proposed 220Kv Gss) Line (Approx. Length -50 Km ) On Turnkey Basis Under Bid Enquiry No. - 9018002537
Basic Detail
Tender No RVPN/EHV/BN-9018002537
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 05 Oct 2026
Submission Date 03 Nov 2026
Open Date 04 Nov 2026
Finance
Tender Value 51.45 Crore
Tender Fee 23600
EMD 1.02 Crore
Exemption Not Available
Document List
AnnexureA.pdf
BOQ_1069438.xls
Commercial.pdf
Corrigendumbhadoti.pdf
f71a5dfb-b785-4246-9ac0-49a563bd6cae.html
PROJECT.pdf
Technical.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Nov 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
pdf

AnnexureA.pdf

xls

BOQ_1069438.xls

pdf

Commercial.pdf

pdf

Corrigendumbhadoti.pdf

html

f71a5dfb-b785-4246-9ac0-49a563bd6cae.html

pdf

PROJECT.pdf

pdf

Technical.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender