Tender For Construction Of 220Kv D/C Gangapur City -Bhadoti (Proposed 220Kv Gss) Line (Approx. Length -50 Km ) On Turnkey Basis Under Bid Enquiry No. - 9018002537
Tender Value
51.45 Crore
Estimated cost
Bid Submission
03 Nov 2026
16 days left
EMD
1.02 Crore
Bank guarantee accepted
Document Fee
23600
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of 220Kv D/C Gangapur City -Bhadoti (Proposed 220Kv Gss) Line (Approx. Length -50 Km ) On Turnkey Basis Under Bid Enquiry No. - 9018002537
BOQ
| Sl. No. | Item Description |
| 1 | Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc. |
| 2 | High Tensile Steel |
| 3 | Mild Steel |
| 4 | Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts and anti theft bolts & nuts, Spring Washers Etc. ) |
| 5 | Supply of Earthing material of Towers |
| 6 | Pipe Type Set |
| 7 | Counter Poise Earthing set |
| 8 | Supply of following Tower Accessories |
| 9 | Danger Plate |
| 10 | Number Plate |
| 11 | Phase Plate (Set of three) |
| 12 | Design, manufacture and supply of following line material. |
| 13 | Disc Insulator - 70 kN |
| 14 | Disc Insulator - 120 kN |
| 15 | Hardware Fittings for ACSR Zebra Conductor |
| 16 | Single Suspension H/W fittings for ACSR Zebra Conductor |
| 17 | Single Tension H/W fittings for ACSR Zebra Conductor |
| 18 | Double Suspension H/W fittings for ACSR Zebra Conductor |
| 19 | Double Tension H/W fittings for ACSR Zebra Conductor |
| 20 | Accessories for ACSR Zebra Conductor |
| 21 | Mid Span Compression Joint for ACSR Zebra Conductor |
| 22 | Repair Sleeve for ACSR Zebra Conductor |
| 23 | Preformed Armour Rod for ACSR Zebra Conductor |
| 24 | Vibration Damper for ACSR Zebra Conductor |
| 25 | OPGW Cable |
| 26 | 48 Fibre (DWSM) OPGW fibre optic cable |
| 27 | Installation Hardware set for 48 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except joint box |
| 28 | Joint box (48 fibre) |
| 29 | FODP 48F: Indoor Type, rack mounted with FCPC coupling and pigtails |
| 30 | FODP 96F: Indoor Type, rack mounted with FCPC coupling and pigtails |
| 31 | Any Other item required for successful completion of work |
| 32 | Note: * Quantity indicated is for evaluation purpose. Actual quantity to be supplied after getting approval. ++One set of installation hardware shall contain all installation hardware fittings as may be required for 1 km of OPGW/Approach Fibre Optic cable. |
| 33 | Detail Survey as per tentative route-Which includes the following major activities-Pegging of line route, providing of survey pillar at an interval of 3-4 KM in the line route with required jungle clearance for survey, profile preparation of approved route on graph sheet and marking of offset on either side of line, marking of side clearance for hills, sand dunes etc, as per specification and tower scheduling. |
| 34 | Check survey as per approved route of line which includes-Re-checking of the line route as per approved profile, chainage, tower center marking, pit marking, bisection of angle tower as required at site. |
| 35 | Excavation-Excavation, excluding back filling, including shoring,shuttering, dewatering, etc. upto the required depth as per foundation specification/drawings. |
| 36 | (i) Any soil, soft rock other than hard rock |
| 37 | (ii) Hard Rock (with blasting subject to permission or without blasting) |
| 38 | SETTING OF TEMPLATE & STUB/ANCHOR BOLT:-Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming andwatering as per specification. |
| 39 | (i) Tower including extension upto 9 Meter |
| 40 | (ii) Special Towers for any span including extension upto 9 Meter |
| 41 | CONCRETING: Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size,water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings. |
| 42 | (i) 1:4:8 Mix |
| 43 | (ii) 1:3:6 Mix |
| 44 | (iii) 1:2:4 Mix |
| 45 | (iv) 1:1.5:3 Mix |
| 46 | STEEL REINFORCEMENT: Cutting, bending, welding of joints if required,fixing and placing of steel reinforcement as per specification and drawings including material. |
| 47 | EARTHING: |
| 48 | (A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation,augering and backfilling in all types of soil. |
| 49 | (B) Earthing of towers legs with counterpoise typeearthings excluding supply of materialsbut including excavation and backfilling in all types of soil.(i)each set by laying 4 wires each 15m long at a depth of 600mm . |
| 50 | ERECTION OF TOWERS: Erection of super structures including D-shackles,ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint |
| 51 | Erection of tower (with extension upto 9 Meters) |
| 52 | Erection of special tower (with extension) |
| 53 | CONDUCTOR STRINGING: Stringing of ACSR Zebra including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line. |
| 54 | (i) Single Conductor |
| 55 | (ii) Single Conductor for river |
| 56 | CONDUCTOR STRINGING: Stringing of ACSR Panther including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line. |
| 57 | (ii) Single Conductor for river |
| 58 | RIVETMENT OF TOWERS |
| 59 | (A) Providing and laying cement concrete including curing, compaction etc. complete using stone aggregate 40 mm nominal size (crusher broken) in foundation plinth, using 1 Cement: 5 Sand: 10 aggregate mix. |
| 60 | (B) Random rubble stone masonary for rivetment in 1:5 cement sand mortar including providing and fixing 100mm dia PCC drain pipe & raised and cut-pointing on stone masonary in 1:3 cement sand mortar excluding excavation but including Back filling inside rivetment using excavated/ borrowed earth (with all lead & lift) in layers not exceeding 20cm in depth & consolidating each deposited layer by ramming and watering. |
| 61 | (C) Random rubble dry stone pitching including preparing surface etc. complete with raised & cut pointing in cement sand mortar 1:3 curing etc. |
| 62 | (D) Cement concrete coping grade 1:2:4 (1cement: 2coarse sand :4 graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of steps etc. complete for 75mm thick with 20mm thick nominal size aggregate |
| 63 | Installation of OPGW |
| 64 | Stringing of 48 Fiber (DWSM) OPGW Fibre Optic Cable |
| 65 | Installation Hardware set for above 48Fibre OPGW cabling including of all cable fittings and accessories except joint box |
| 66 | Joint box (48 Fiber) OPGW Cable |
| 67 | FODP 48F : Indoor Type, rack mounted with FCPC coupling and pigtails |
| 68 | FODP 96F : Indoor Type, rack mounted with FCPC coupling and pigtails |
| 69 | Land Identification and Compensation |
| 70 | For Scope of work as specified at item no. a(I to iv) in Annexure-A (Enclosed) |
| 71 | For Scope of work as specified at item no. a(I to iv) in Annexure-A (Enclosed) |
| 72 | Any Other Item |
| 73 | Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc. |
| 74 | High Tensile Steel |
| 75 | Mild Steel |
| 76 | Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts and anti theft bolts & nuts, Spring Washers Etc. ) |
| 77 | Supply of Earthing material of Towers |
| 78 | Pipe Type Set |
| 79 | Supply of following Tower Accessories |
| 80 | Danger Plate |
| 81 | Number Plate |
| 82 | Phase Plate (Set of three) |
| 83 | Design, manufacture and supply of following line material. |
| 84 | Disc Insulator - 70 kN |
| 85 | Disc Insulator - 120 kN |
| 86 | Porcelain Long Rod Insulators - 120kN |
| 87 | Hardware Fittings for ACSR Zebra Conductor |
| 88 | Single Suspension H/W fittings for ACSR Zebra Conductor |
| 89 | Single Tension H/W fittings for ACSR Zebra Conductor |
| 90 | Double Tension H/W fittings for ACSR Zebra Conductor |
| 91 | Accessories for ACSR Zebra Conductor |
| 92 | Mid Span Compression Joint for ACSR Zebra Conductor |
| 93 | Repair Sleeve for ACSR Zebra Conductor |
| 94 | Vibration Damper for ACSR Zebra Conductor |
| 95 | G.I. Earth wire 7/3.15 |
| 96 | Strain Assembly for Earth wire 7/3.15 with copper earth Bond |
| 97 | Suspension Assembly for Earth wire 7/3.15 with copper earth bond |
| 98 | Vibration Damper for Earth wire 7/3.15 |
| 99 | OPGW Cable |
| 100 | 48 Fibre (DWSM) OPGW fibre optic cable |
| 101 | Installation Hardware set for 48 Fibre OPGW Fibre optic cabling including all cable fittings & accessories except joint fox |
| 102 | Joint box (48Fibre) |
| 103 | Any Other item required for successful completion of work |
| 104 | Note: * Quantity indicated is for evaluation purpose. Actual quantity to be supplied after getting approval. ++One set of installation hardware shall contain all installation hardware fittings as may be required for 1 km of OPGW/Approach Fibre Optic cable. |
| 105 | Detail Survey as per tentative route-Which includes the following major activities-Pegging of line route, providing of survey pillar at an interval of 3-4 KM in the line route with required jungle clearance for survey, profile preparation of approved route on graph sheet and marking of offset on either side of line, marking of side clearance for hills, sand dunes etc, as per specification and tower scheduling. |
| 106 | Check survey as per approved route of line which includes-Re-checking of the line route as per approved profile, chainage, tower center marking, pit marking, bisection of angle tower as required at site. |
| 107 | Excavation-Excavation, excluding back filling, including shoring,shuttering, dewatering, etc. upto the required depth as per foundation specification/drawings. |
| 108 | (i) Any soil, soft rock other than hard rock |
| 109 | (ii) Hard Rock (with blasting subject to permission or without blasting) |
| 110 | SETTING OF TEMPLATE & STUB/ANCHOR BOLT:-Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming andwatering as per specification. |
| 111 | (i) Tower including extension upto 9 Meter |
| 112 | CONCRETING: Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size,water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings. |
| 113 | (i) 1:4:8 Mix |
| 114 | (ii) 1:3:6 Mix |
| 115 | (iii) 1:2:4 Mix |
| 116 | (iv) 1:1.5:3 Mix |
| 117 | STEEL REINFORCEMENT: Cutting, bending, welding of joints if required,fixing and placing of steel reinforcement as per specification and drawings including material. |
| 118 | EARTHING: |
| 119 | (A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation,augering and backfilling in all types of soil. |
| 120 | ERECTION OF TOWERS: Erection of super structures including D-shackles,ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint |
| 121 | Erection of tower (with extension upto 9 Meters) |
| 122 | CONDUCTOR STRINGING: Stringing of ACSR Zebra including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line. |
| 123 | (i) Single Conductor |
| 124 | EarthwireStringing :- (A) Stringing of galvanised steel stranded wire including laying,jointing & tensioning, clamping,clipping and fixing vibration damper and earth bond etc. |
| 125 | (i)One No. 7/3.15 mm galvanised wire |
| 126 | RIVETMENT OF TOWERS |
| 127 | (A) Providing and laying cement concrete including curing, compaction etc. complete using stone aggregate 40 mm nominal size (crusher broken) in foundation plinth, using 1 Cement: 5 Sand: 10 aggregate mix. |
| 128 | (B) Random rubble stone masonary for rivetment in 1:5 cement sand mortar including providing and fixing 100mm dia PCC drain pipe & raised and cut-pointing on stone masonary in 1:3 cement sand mortar excluding excavation but including Back filling inside rivetment using excavated/ borrowed earth (with all lead & lift) in layers not exceeding 20cm in depth & consolidating each deposited layer by ramming and watering. |
| 129 | (C) Random rubble dry stone pitching including preparing surface etc. complete with raised & cut pointing in cement sand mortar 1:3 curing etc. |
| 130 | (D) Cement concrete coping grade 1:2:4 (1cement: 2coarse sand :4 graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of steps etc. complete for 75mm thick with 20mm thick nominal size aggregate |
| 131 | Installation of OPGW |
| 132 | Stringing of 48 Fiber (DWSM) OPGW Fibre Optic Cable |
| 133 | Installation Hardware set for above 48Fibre OPGW cabling including of all cable fittings and accessories except joint box |
| 134 | Joint box (48 Fiber) OPGW Cable |
| 135 | Re-Stringing of 24 Fibre (DWSM) OPGW Fibre Optic cable, re-installation of hardware set for 24 fibre OPGW Fibre optic cabling including all cable fittings and accessories except joint box |
| 136 | Re-Stringing of 24 Fibre (DWSM) OPGW Fibre Optic cable, re-installation of 24 fibre OPGW optic cabling including all cable fittings and accessories except joint box |
| 137 | Land identification and compensation |
| 138 | For Scope of work as specified at item no. a(I to iv) in Annexure-A (Enclosed) |
| 139 | For Scope of work as specified at item no. a(I to iv) in Annexure-A (Enclosed) |
| 140 | Any Other Item |
| 141 | Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc. |
| 142 | High Tensile Steel |
| 143 | Mild Steel |
| 144 | Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts and anti theft bolts & nuts, Spring Washers Etc. ) |
| 145 | Supply of Earthing material of Towers |
| 146 | Pipe Type Set |
| 147 | Supply of following Tower Accessories |
| 148 | Danger Plate |
| 149 | Number Plate |
| 150 | Phase Plate (Set of three) |
| 151 | Design, manufacture and supply of following line material. |
| 152 | (i)Disc Insulator - 70 kN |
| 153 | (i)Disc Insulator - 120 kN |
| 154 | Hardware Fittings for ACSR Panther Conductor |
| 155 | Single Suspension H/W fittings for ACSR Panther Conductor |
| 156 | Single Tension H/W fittings for ACSR Panther Conductor |
| 157 | Double Suspension H/W fittings for ACSR Panther Conductor |
| 158 | Double Tension H/W fittings for ACSR Panther Conductor |
| 159 | Accessories for ACSR Panther Conductor |
| 160 | Mid Span Compression Joint for ACSR Panther Conductor |
| 161 | Repair Sleeve for ACSR Panther Conductor |
| 162 | Preformed Armour Rod for ACSR Panther Conductor |
| 163 | Vibration Damper for ACSR Panther Conductor |
| 164 | OPGW Cable |
| 165 | 24 Fibre (DWSM) OPGW fibre optic cable |
| 166 | Installation Hardware set for 24 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except joint box |
| 167 | Joint box (24Fibre) |
| 168 | FODP 48F: Indoor Type, rack mounted with FCPC coupling and pigtails |
| 169 | Any Other item required for successful completion of work |
| 170 | Note: * Quantity indicated is for evaluation purpose. Actual quantity to be supplied after getting approval. ++One set of installation hardware shall contain all installation hardware fittings as may be required for 1 km of OPGW/Approach Fibre Optic cable. |
| 171 | Detail Survey as per tentative route-Which includes the following major activities-Pegging of line route, providing of survey pillar at an interval of 3-4 KM in the line route with required jungle clearance for survey, profile preparation of approved route on graph sheet and marking of offset on either side of line, marking of side clearance for hills, sand dunes etc, as per specification and tower scheduling. |
| 172 | Check survey as per approved route of line which includes-Re-checking of the line route as per approved profile, chainage, tower center marking, pit marking, bisection of angle tower as required at site. |
| 173 | Excavation-Excavation, excluding back filling, including shoring,shuttering, dewatering, etc. upto the required depth as per foundation specification/drawings. |
| 174 | (i) Any soil, soft rock other than hard rock |
| 175 | (ii) Hard Rock (with blasting subject to permission or without blasting) |
| 176 | SETTING OF TEMPLATE & STUB/ANCHOR BOLT:-Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming andwatering as per specification. |
| 177 | (i) Tower including extension upto 9 Meter |
| 178 | CONCRETING: Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size,water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings. |
| 179 | (i) 1:4:8 Mix |
| 180 | (ii) 1:3:6 Mix |
| 181 | (iii) 1:2:4 Mix |
| 182 | (iv) 1:1.5:3 Mix |
| 183 | STEEL REINFORCEMENT: Cutting, bending, welding of joints if required,fixing and placing of steel reinforcement as per specification and drawings including material. |
| 184 | EARTHING: |
| 185 | (A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation,augering and backfilling in all types of soil. |
| 186 | ERECTION OF TOWERS: Erection of super structures including D-shackles,ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint |
| 187 | Erection of tower (with extension upto 9 Meters) |
| 188 | CONDUCTOR STRINGING: Stringing of ACSR Panther including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line. |
| 189 | (i) Single Conductor |
| 190 | (i) Single Conductor for river |
| 191 | RIVETMENT OF TOWERS |
| 192 | (A) Providing and laying cement concrete including curing, compaction etc. complete using stone aggregate 40 mm nominal size (crusher broken) in foundation plinth, using 1 Cement: 5 Sand: 10 aggregate mix. |
| 193 | (B) Random rubble stone masonary for rivetment in 1:5 cement sand mortar including providing and fixing 100mm dia PCC drain pipe & raised and cut-pointing on stone masonary in 1:3 cement sand mortar excluding excavation but including Back filling inside rivetment using excavated/ borrowed earth (with all lead & lift) in layers not exceeding 20cm in depth & consolidating each deposited layer by ramming and watering. |
| 194 | (C) Random rubble dry stone pitching including preparing surface etc. complete with raised & cut pointing in cement sand mortar 1:3 curing etc. |
| 195 | (D) Cement concrete coping grade 1:2:4 (1cement: 2coarse sand :4 graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of steps etc. complete for 75mm thick with 20mm thick nominal size aggregate |
| 196 | Installation of OPGW |
| 197 | Stringing of 24 Fiber (DWSM) OPGW FIBRE OPTIC CABLE |
| 198 | Installation Hardware set for above 24 Fibre OPGW cabling including of al cable fittings and accessories exept joint Box |
| 199 | JOINT BOX (24 FIBER) OPGW CABLE |
| 200 | FODP 48F : Indoor Type, rack mounted with FCPC coupling and pigtails |
| 201 | Land identification and compensation |
| 202 | For Scope of work as specified at item no. a(I to iv) in Annexure-A (Enclosed) |
| 203 | For Scope of work as specified at item no. a(I to iv) in Annexure-A (Enclosed) |
| 204 | Any Other Item |
| 205 | Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc. |
| 206 | High Tensile Steel |
| 207 | Mild Steel |
| 208 | Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts and anti theft bolts & nuts, Spring Washers Etc. ) |
| 209 | Sub Station Structures All type |
| 210 | Supply of Earthing material of Towers |
| 211 | Pipe Type Set |
| 212 | Supply of following Tower Accessories |
| 213 | Danger Plate |
| 214 | Number Plate |
| 215 | Phase Plate (Set of three) |
| 216 | Design, manufacture and supply of following line material. |
| 217 | (i)Disc Insulator - 70 kN |
| 218 | (i)Disc Insulator - 120 kN |
| 219 | Hardware Fittings for ACSR Panther Conductor |
| 220 | Single Suspension H/W fittings for ACSR Panther Conductor |
| 221 | Single Tension H/W fittings for ACSR Panther Conductor |
| 222 | Double Suspension H/W fittings for ACSR Panther Conductor |
| 223 | Double Tension H/W fittings for ACSR Panther Conductor |
| 224 | Accessories for ACSR Panther Conductor |
| 225 | Mid Span Compression Joint for ACSR Panther Conductor |
| 226 | Repair Sleeve for ACSR Panther Conductor |
| 227 | Preformed Armour Rod for ACSR Panther Conductor |
| 228 | Vibration Damper for ACSR Panther Conductor |
| 229 | OPGW Cable |
| 230 | 48 Fibre (DWSM) OPGW fibre optic cable |
| 231 | Installation Hardware set for 48 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except joint box |
| 232 | Joint box (48Fibre) |
| 233 | FODP 48F: Indoor Type, rack mounted with FCPC coupling and pigtails |
| 234 | Any Other item required for successful completion of work |
| 235 | Note: * Quantity indicated is for evaluation purpose. Actual quantity to be supplied after getting approval. ++One set of installation hardware shall contain all installation hardware fittings as may be required for 1 km of OPGW/Approach Fibre Optic cable. |
| 236 | Detail Survey as per tentative route-Which includes the following major activities-Pegging of line route, providing of survey pillar at an interval of 3-4 KM in the line route with required jungle clearance for survey, profile preparation of approved route on graph sheet and marking of offset on either side of line, marking of side clearance for hills, sand dunes etc, as per specification and tower scheduling. |
| 237 | Check survey as per approved route of line which includes-Re-checking of the line route as per approved profile, chainage, tower center marking, pit marking, bisection of angle tower as required at site. |
| 238 | Excavation-Excavation, excluding back filling, including shoring,shuttering, dewatering, etc. upto the required depth as per foundation specification/drawings. |
| 239 | (i) Any soil, soft rock other than hard rock |
| 240 | (ii) Hard Rock (with blasting subject to permission or without blasting) |
| 241 | SETTING OF TEMPLATE & STUB/ANCHOR BOLT:-Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming andwatering as per specification. |
| 242 | (i) Tower including extension upto 9 Meter |
| 243 | CONCRETING: Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size,water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings. |
| 244 | (i) 1:4:8 Mix |
| 245 | (ii) 1:3:6 Mix |
| 246 | (iii) 1:2:4 Mix |
| 247 | (iv) 1:1.5:3 Mix |
| 248 | STEEL REINFORCEMENT: Cutting, bending, welding of joints if required,fixing and placing of steel reinforcement as per specification and drawings including material. |
| 249 | EARTHING: |
| 250 | (A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation,augering and backfilling in all types of soil. |
| 251 | ERECTION OF TOWERS: Erection of super structures including D-shackles,ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint |
| 252 | Erection of tower (with extension upto 9 Meters) |
| 253 | ERECTION OF SUB STATION STRCTURES: Erection of substation structures including leveling, setting of stub & Tighting, Punching of Nuts& Bolts and tack welding upto beam level as per specification. |
| 254 | CONDUCTOR STRINGING: Stringing of ACSR Panther including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line. |
| 255 | (i) Single Conductor |
| 256 | RIVETMENT OF TOWERS |
| 257 | (A) Providing and laying cement concrete including curing, compaction etc. complete using stone aggregate 40 mm nominal size (crusher broken) in foundation plinth, using 1 Cement: 5 Sand: 10 aggregate mix. |
| 258 | (B) Random rubble stone masonary for rivetment in 1:5 cement sand mortar including providing and fixing 100mm dia PCC drain pipe & raised and cut-pointing on stone masonary in 1:3 cement sand mortar excluding excavation but including Back filling inside rivetment using excavated/ borrowed earth (with all lead & lift) in layers not exceeding 20cm in depth & consolidating each deposited layer by ramming and watering. |
| 259 | (C) Random rubble dry stone pitching including preparing surface etc. complete with raised & cut pointing in cement sand mortar 1:3 curing etc. |
| 260 | (D) Cement concrete coping grade 1:2:4 (1cement: 2coarse sand :4 graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of steps etc. complete for 75mm thick with 20mm thick nominal size aggregate |
| 261 | Installation of OPGW |
| 262 | Stringing of 48 Fiber (DWSM) OPGW FIBRE OPTIC CABLE |
| 263 | Installation Hardware set for above 48Fibre OPGW cabling including of al cable fittings and accessories exept joint Box |
| 264 | JOINT BOX (48 FIBER) OPGW CABLE |
| 265 | FODP 48F : Indoor Type, rack mounted with FCPC coupling and pigtails |
| 266 | Re-Stringing of 24 Fibre (DWSM) OPGW Fibre Optic cable, re-installation of hardware set for 24 fibre OPGW Fibre optic cabling including all cable fittings and accessories except joint box |
| 267 | Restringing of conductor/Earthwire |
| 268 | A.) Restringing of ACSR Panther conductor: Dismentalling of vibration dampers, Armour Rods fitting of rollers, de-tensioning, holding and lowering of conductor, rehoisting of insulator string as required, adding/removing and jointing of conductor, hoisting of insulator string, lifting of conductor rollers and retensioning, jointing, fitting of armour rods and vibration damper and clamping per route KM of the line section to be restrung dismenatalled material notreused to be deposited in our stores and stacked |
| 269 | i. Any Single Conductor |
| 270 | Dismentalling of Towers:- Dismentalling of superstructures along with extensions, having tack welded bolts and nuts including removing of D-shackles, Hnagers, U-Bolts, Step Bolts, ACD, Danger Plate, Phase plate, Number Plate of the tower including transportation from site to our store and stacking of all material. |
| 271 | A.) 132KV & 220KV S/C & D/C Towers all types |
| 272 | Restringing of 24FIBER DWSM OPGW fibre optic cable reinstallation of 24 F OPGW optic cabling including all cable fitting and accessories except joint box. |
| 273 | Land identification and compensation |
| 274 | For Scope of work as specified at item no. a(I to iv) in Annexure-A (Enclosed) |
| 275 | For Scope of work as specified at item no. a(I to iv) in Annexure-A (Enclosed) |
| 276 | Any Other Item |
| 277 | Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc. |
| 278 | High Tensile Steel |
| 279 | Mild Steel |
| 280 | Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts and anti theft bolts & nuts, Spring Washers Etc. ) |
| 281 | Supply of Earthing material of Towers |
| 282 | Pipe Type Set |
| 283 | Supply of following Tower Accessories |
| 284 | Danger Plate |
| 285 | Number Plate |
| 286 | Phase Plate (Set of three) |
| 287 | Design, manufacture and supply of following line material. |
| 288 | (i)Disc Insulator - 70 kN |
| 289 | (i)Disc Insulator - 120 kN |
| 290 | Hardware Fittings for ACSR Panther Conductor |
| 291 | Single Suspension H/W fittings for ACSR Panther Conductor |
| 292 | Single Tension H/W fittings for ACSR Panther Conductor |
| 293 | Double Suspension H/W fittings for ACSR Panther Conductor |
| 294 | Double Tension H/W fittings for ACSR Panther Conductor |
| 295 | Accessories for ACSR Panther Conductor |
| 296 | Mid Span Compression Joint for ACSR Panther Conductor |
| 297 | Repair Sleeve for ACSR Panther Conductor |
| 298 | Preformed Armour Rod for ACSR Panther Conductor |
| 299 | Vibration Damper for ACSR Panther Conductor |
| 300 | OPGW Cable |
| 301 | 48 Fibre (DWSM) OPGW fibre optic cable |
| 302 | Installation Hardware set for 48 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except joint box |
| 303 | Joint box (48Fibre) |
| 304 | Any Other item required for successful completion of work |
| 305 | Note: * Quantity indicated is for evaluation purpose. Actual quantity to be supplied after getting approval. ++One set of installation hardware shall contain all installation hardware fittings as may be required for 1 km of OPGW/Approach Fibre Optic cable. |
| 306 | Detail Survey as per tentative route-Which includes the following major activities-Pegging of line route, providing of survey pillar at an interval of 3-4 KM in the line route with required jungle clearance for survey, profile preparation of approved route on graph sheet and marking of offset on either side of line, marking of side clearance for hills, sand dunes etc, as per specification and tower scheduling. |
| 307 | Check survey as per approved route of line which includes-Re-checking of the line route as per approved profile, chainage, tower center marking, pit marking, bisection of angle tower as required at site. |
| 308 | Excavation-Excavation, excluding back filling, including shoring,shuttering, dewatering, etc. upto the required depth as per foundation specification/drawings. |
| 309 | (i) Any soil, soft rock other than hard rock |
| 310 | (ii) Hard Rock (with blasting subject to permission or without blasting) |
| 311 | SETTING OF TEMPLATE & STUB/ANCHOR BOLT:-Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming andwatering as per specification. |
| 312 | (i) Tower including extension upto 9 Meter |
| 313 | CONCRETING: Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size,water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings. |
| 314 | (i) 1:4:8 Mix |
| 315 | (ii) 1:3:6 Mix |
| 316 | (iii) 1:2:4 Mix |
| 317 | (iv) 1:1.5:3 Mix |
| 318 | STEEL REINFORCEMENT: Cutting, bending, welding of joints if required,fixing and placing of steel reinforcement as per specification and drawings including material. |
| 319 | EARTHING: |
| 320 | (A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation,augering and backfilling in all types of soil. |
| 321 | ERECTION OF TOWERS: Erection of super structures including D-shackles,ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint |
| 322 | Erection of tower (with extension upto 9 Meters) |
| 323 | CONDUCTOR STRINGING: Stringing of ACSR Panther including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line. |
| 324 | (i) Single Conductor |
| 325 | RIVETMENT OF TOWERS |
| 326 | (A) Providing and laying cement concrete including curing, compaction etc. complete using stone aggregate 40 mm nominal size (crusher broken) in foundation plinth, using 1 Cement: 5 Sand: 10 aggregate mix. |
| 327 | (B) Random rubble stone masonary for rivetment in 1:5 cement sand mortar including providing and fixing 100mm dia PCC drain pipe & raised and cut-pointing on stone masonary in 1:3 cement sand mortar excluding excavation but including Back filling inside rivetment using excavated/ borrowed earth (with all lead & lift) in layers not exceeding 20cm in depth & consolidating each deposited layer by ramming and watering. |
| 328 | (C) Random rubble dry stone pitching including preparing surface etc. complete with raised & cut pointing in cement sand mortar 1:3 curing etc. |
| 329 | (D) Cement concrete coping grade 1:2:4 (1cement: 2coarse sand :4 graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of steps etc. complete for 75mm thick with 20mm thick nominal size aggregate |
| 330 | Installation of OPGW |
| 331 | Stringing of 48 Fiber (DWSM) OPGW FIBRE OPTIC CABLE |
| 332 | Installation Hardware set for above 48Fibre OPGW cabling including of al cable fittings and accessories exept joint Box |
| 333 | JOINT BOX (48 FIBER) OPGW CABLE |
| 334 | Restringing of 24FIBER DWSM OPGW fibre optic cable reinstallation of hardware set for 24 F OPGW optic cabling including all cable fitting and accessories except joint box. |
| 335 | Restringing of conductor/Earthwire |
| 336 | A.) Restringing of ACSR Panther conductor: Dismentalling of vibration dampers, Armour Rods fitting of rollers, de-tensioning, holding and lowering of conductor, rehoisting of insulator string as required, adding/removing and jointing of conductor, hoisting of insulator string, lifting of conductor rollers and retensioning, jointing, fitting of armour rods and vibration damper and clamping per route KM of the line section to be restrung dismenatalled material notreused to be deposited in our stores and stacked |
| 337 | i. Any Single Conductor |
| 338 | Dismentalling of Towers:- Dismentalling of superstructures along with extensions, having tack welded bolts and nuts including removing of D-shackles, Hnagers, U-Bolts, Step Bolts, ACD, Danger Plate, Phase plate, Number Plate of the tower including transportation from site to our store and stacking of all material. |
| 339 | A.) 132KV & 220KV S/C & D/C Towers all types |
| 340 | Restringing of 24FIBER DWSM OPGW fibre optic cable reinstallation of 24 F OPGW optic cabling including all cable fitting and accessories except joint box. |
| 341 | Land identification and compensation |
| 342 | For Scope of work as specified at item no. a(I to iv) in Annexure-A (Enclosed) |
| 343 | For Scope of work as specified at item no. a(I to iv) in Annexure-A (Enclosed) |
| 344 | Any Other Item Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysNov 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender