Tender For Providing Heat Sensing System In Electric Panels Installed In The Sub Station Of Sarai Building, Block-O, Gmch-32, Chandigarh.
Tender Value
16.93 Lakhs
Estimated cost
Bid Submission
12 Oct 2026
3 days left
EMD
33880
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing Heat Sensing System In Electric Panels Installed In The Sub Station Of Sarai Building, Block-O, Gmch-32, Chandigarh.
BOQ
| Sl. No. | Item Description |
| 1 | DSR item No. 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 2 | 25 mm |
| 3 | DSR item No. 28.2.14 Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 4 | DSR item No. 28.2.15 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. |
| 5 | DSR item No. 39.17 Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range: -5° to +60°C. Bending Radius: < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force: 11.5Kg etc. complete as required. |
| 6 | 1 Run of cable |
| 7 | Supply, installation, testing and commissioning of 32-bit microprocessor-based intelligent addressable 1-loop fire alarm control panel, VdS approved and EN-54 compliant, with 680-character LCD display, battery backup for 24 hours, capable of storing 60,000 events and supporting up to 250 devices per loop (min. 200 detectors). The panel shall have TCP/IP LAN port for remote commissioning and operation, provide alarm, pre-alarm and fault indication, and include all necessary wiring, termination, mounting, programming, testing and commissioning, complete to the satisfaction of the Engineer-in-Charge. Make: Schrack/Securiton/ Listec only. |
| 8 | 1 Loop Panel. |
| 9 | Supply, installation, testing and commissioning of connection box / connection unit for Linear Heat Detection System, suitable for feeding and interconnecting one to two SEC-15 temperature sensor cables, complete with Universal Connection Module (UCM). The enclosure shall be of high-impact, flame-retardant polycarbonate, suitable for indoor/outdoor use, with minimum IP65 protection, including all terminals, glands, mounting accessories and labeling, complete to the satisfaction of the Engineer-in-Charge. Make: Schrack/Securiton/ Listec only. |
| 10 | Supplying, installation, testing and commissioning of VdS-approved Signal Processor Unit for Linear Heat Detection System, complete with LED display and alarm, pre-alarm and fault relays, capable of supporting 2 × 350 m sensor cable length with 10 to 100 sensors per line. The unit shall provide alarm triggering based on differential and maximum temperature evaluation, with 0.1°C temperature resolution and ±0.1 K repeatability over the entire sensor length. The panel shall support MODBUS TCP/IP via Ethernet, have IP65 protection, and operate in the temperature range of –25°C to +70°C. The system shall incorporate intelligent algorithms to prevent false alarms, utilize maintenance-free modular components, be RoHS compliant, and provide password-protected access levels for operation, maintenance and commissioning, complete to the satisfaction of the Engineer-in-Charge. Make: Schrack/Securiton/ Listec only. |
| 11 | Supplying, installation, testing and commissioning of VdS-approved Linear Heat Sensing Cable System, complete in all respects, with fully encapsulated sensors at every 5 m interval, suitable for continuous temperature monitoring in the range of –40°C to +85°C. The system shall provide pinpoint alarm location through individually addressable sensors, continuously monitored by a dedicated control and evaluation unit, and shall support freely adjustable fixed temperature and rate-of-rise alarm thresholds. Branching of cable routes through approved connection boxes shall be permitted without loss of monitoring or addressability. The item shall include all accessories, interconnections, testing, commissioning and integration, complete to the satisfaction of the Engineer-in-Charge and as per manufacturer’s recommendations and applicable standards. Make: Schrack/Securiton/ Listec only. |
| 12 | Supply, laying, termination, testing and commissioning of access / interconnecting cable for the Linear Heat Detection System, for connecting the heat sensing cable with the control and evaluation unit and remote display, complete in all respects. The cable shall be manufacturer-recommended, with stranded copper conductors, FR/FRLS/LSZH insulation, rated 300/500 V, and suitably screened/shielded against electromagnetic interference, with a flame-retardant outer sheath. The cable shall be laid in GI/PVC conduit, cable trays or trenches with proper segregation from power cables, terminated with approved accessories, tested for continuity, insulation and communication integrity, and commissioned as per applicable standards, complete to the satisfaction of the Engineer-in-Charge. Make: Schrack/Securiton/ Listec only. |
| 13 | Supplying, installation, testing and commissioning of network switch, complete in all respects, suitable for reliable communication between the Linear Heat Detection System / fire detection controller / remote display / BMS network. Make: Dlink/ Netgear/HP only. |
| 14 | Supply and laying of 2C × 1.0 sq.mm twisted, multi-stranded copper FRLS, shielded and armoured cable suitable for Fire Alarm System (FAS), complete in all respects, including laying in conduit/tray, proper termination, testing and commissioning, as per applicable standards and to the satisfaction of the Engineer-in-Charge. Make: Polycab/ Finolex/ Havells/ KEI only. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysOct 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓