Housing Urban and Rular Development Local Bodies Closing in 3 days TDR #57864553

Tender For Maintenance Of Electrical Installation In Residential Building At Chandigarh (Rewiring Of 2 Nos. Houses I.E. H. No. 1355-B & H. No. 1793 In Sector-43, Chandigarh Under Jurisdiction Of Sde, E-2, Chandigarh).

Issued by Local Bodies · Chandigarh, Chandigarh
Tender Value
1.58 Lakhs
Estimated cost
Bid Submission
12 Oct 2026
3 days left
EMD
3180
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Maintenance Of Electrical Installation In Residential Building At Chandigarh (Rewiring Of 2 Nos. Houses I.E. H. No. 1355-B & H. No. 1793 In Sector-43, Chandigarh Under Jurisdiction Of Sde, E-2, Chandigarh).

BOQ

Name of Work:- MAINTENANCE OF ELECTRICAL INSTALLATION IN RESIDENTIAL BUILDING AT CHANDIGARH (REWIRING OF 2 NOS. HOUSES I.E. H. NO. 1355-B & H. NO. 1793 IN SECTOR-43, CHANDIGARH UNDER JURISDICTION OF SDE, E-2, CHANDIGARH).
Sl. No. Item Description
1DSR item No.1.8 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
2Group A
3Group B
4DSR item No. 1.15 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
5Group A
6Group B
7DSR item No.1.16 Rewiring for twin Control Light Point With 1.5 sq.mm FRLS/HFFR PVC Insulated Copper Conductor Single Core Cable And 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed Steel/PVC conduit including dismantling as required.
8DSR item No. 1.17 Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
93 x 1.5 sq. mm
103 x 2.5 sq. mm
113 x 4 sq. mm
123 x 6 sq. mm
13DSR item No. 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
1425 mm
15DSR item No. 1.22 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
1675 mm X 75 mm X 60 mm deep
17150 mm X 75 mm X 60 mm deep
18180 mm X 100 mm X 60 mm deep
19200 mm X 125 mm X 60 mm deep
20200 mm X 250 mm X 60 mm deep
21DSR item No. 1.23 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
225/6 amps switch
232 way 5/6 A switch
2415/16 A switch
253 pin 5/6 A socket outlet
266 pin 15/16 A socket outlet
27Telephone socket outlet
28TV antenna socket outlet
29Bell push
30DSR item No. 1.29 Supplying and fixing metal box of 150mm X 75mm X60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections,painting etc. as required.
31DSR item No. 1.30 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
32DSR item No. 1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
33DSR item No. 1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
34DSR item No. 2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
358 way, Double door
36DSR item No. 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
374 way (4 + 12), Double door
38DSR item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
39Single pole
40Double pole
41Triple pole and neutral
42DSR Item No. 2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
43DSR item No. 2.18 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
44S/E of LED Bulk Head Luminaries weather proof frosted light with PMMA / PC reflector and silicon gasket to be installed on surface. The LED fitting should have minimum system Lumen output minimum 1000 Lumen and the driver of the fitting should be workable on 140-260 Volt. The colour temperature of LED should be minimum 5000 degree Kelvin. The LED Bulk Head fitting should be of Philips / Wipro / Bajaj / Crompton / Havells / Lighting Technologies/ Trilux/ Panasonic/ Jaquar/ Surya make only. The fitting should be of IP-65/66. The LED should have a life of 50000 burning Hours. The fitting should have THD<15% and power factor 0.9 or above. The job includes the cost of testing, commissioning and making connection with copper wire from adjacent light point, other petty material and labour etc. as required to complete the same to the entire satisfaction of Engineer-in -Charge.
45S/E of 3mm thick white glazed Bakelite sheet on the existing M.S box. The job includes the cost of sheets and making holes and cutting charges of switches & sockets. The job includes the cost of all labour & petty material required to complete the job. The Bakelite sheet should be of Superhylam/ Greenlam/ Formica make only.
46Supply/ Erection of Bakelite batton holder large size ISI make including making necessary connection to complete to the job to the entire satisfaction of EIC. The holder should be of Anchor (Penta)/ Havells (Reo)/ SSK make only.
47S/E of electronic fan regulator step type socket type in the existing bakelite sheet including cutting the sheet and making connection etc. The job includes all labour and petty material required to complete the job to the entire satisfaction of the Engineer-in-Charge of the work. The fan regulator should be of Anchor (Penta)/ Havells (Reo)/ SSK make only.
48Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making the hole to suit the size of above fan making good the damage, Carriage Charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of Engineer-in-charge.
49Size 12 inches (300mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver of Havells (Turbo Force SP) / Orient (Industrial Heavy Duty)/ Usha (Turbo HDEF)/ Crompton (EXHD300-6-1)/ Bajaj (Supreme Plus) make only.
50DSR item No.9.1 Brush Less Direct Current (BLDC) Fan with Remote (Please refer DNIT for complete specification of item no.22)
511200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
521400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57864553
AUTHORITY Local Bodies
TENDER VALUE 1.58 Lakhs
LAST DATE 12-10-2026
Authority
Authority Name Chandigarh Administration Engineering Department
Work Description Tender for Maintenance Of Electrical Installation In Residential Building At Chandigarh (Rewiring Of 2 Nos. Houses I.E. H. No. 1355-B & H. No. 1793 In Sector-43, Chandigarh Under Jurisdiction Of Sde, E-2, Chandigarh).
Basic Detail
Tender No E2/26/126
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 05 Oct 2026
Submission Date 12 Oct 2026
Open Date 12 Oct 2026
Finance
Tender Value 1.58 Lakhs
Tender Fee Ref. Documents
EMD 3180
Exemption Not Available
Document List
9a93441e-3412-4aa0-95d7-5af9420da83b.html
BOQ_117868.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Oct 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

9a93441e-3412-4aa0-95d7-5af9420da83b.html

xls

BOQ_117868.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail