Tender For The Beautification Of The Dr. B.R. Ambedkar Statue At Ghanhi Under The Dr. Bhim Rao Ambedkar Statue Scheme.
Tender Value
8.46 Lakhs
Estimated cost
Bid Submission
10 Oct 2026
0 days left
EMD
16931
Bank guarantee accepted
Document Fee
950
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gonda → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For The Beautification Of The Dr. B.R. Ambedkar Statue At Ghanhi Under The Dr. Bhim Rao Ambedkar Statue Scheme.
BOQ
| Sl. No. | Item Description |
| 1 | Civil Work: |
| 2 | Excavation in foundation in ordinary soil as directed by the Engineer-incharges.as per SI.No. 251 |
| 3 | Earthwork in cutting or in embankment in ordinary soil as directed by the Engineer-incharges. as per SI.No. 253 with cartage 2.00 km distance |
| 4 | Foundation concrete 1:6:12 with cement Fine sand and 40 mm Brick ballast in all complete as per PWD SI.No. 273 |
| 5 | Class-150 brick work in 1:4 cement and C/sand of 1.25 fineness modukus mortar in foundation and plinth including supply of all materials labour and tools and plants etc. required for proper completion of work. As per SI.No. 305b |
| 6 | R.C.C. work in 1:2:4 with cement C/sand and 20 mm stone grits. As per SI.No. 284 |
| 7 | R.C.C. work in 1:2:4 with cement C/sand and 20 mm stone grits. As per SI.No. 288 |
| 8 | Mild steel for re-inforcement as per SI.No. 504b |
| 9 | Class-150 brick work in 1:4 cement and C/sand of 1.25 fineness modukus mortar in foundation and supurstructer including supply of all materials labour and tools and plants etc. required for proper completion of work. As per SI.No. 305b+309 |
| 10 | 12mm thick plaster with Cement, C/sand in 1:3 mortar supply of all materials labour T&P etc requried for proper completion of work Sl No. 583 |
| 11 | Supply and Laying of Rubber moulded reflective Zig-Zag 80 mm thick precast compressed CC inter locking block, compressive strength shall not be less that 30 MPA and weight not less that 5.5kg each block including cost of 50 mm thick bedding manfcatured by high pressure and controlled vibration machine having minimum 5 mm thick topping CP Cement Mixed 25% marble powder the compressive strength of concrete paver block as per drawing and confirming IRC-SP-63-2004 including cost all material labour T&P etc. with 3 cm thick beding (cussion) of fine sand and 8 cm depth jointing of interlocking with fine sand and also including filling gap the cost of all material, labour & T&P etc. complete of work (Grey inter locking 32.00 @75% =24 No., Red inter locking 32.00 @25% =8 No./sqm) As per Technical Specification Clause 1504 Sr. No. 6.7 |
| 12 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. DSR No. 13.80 |
| 13 | One priming coat and two coat of aoil bound distemper on new work including supply of all material labour and T&P etc complete as per SI.No. 649, 650 |
| 14 | Supply and fixing Mild steel iron gate as per SI.No. 503 |
| 15 | Providing and laying gang saw cut 30mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour, and texture in foothpath, flooring in road side plazas and similar location, laid over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) icnluding grouting the joints with white cement mixed with matching pigment, expoy touch ups etc. complete as per direction of Engineer-in-charge. As per DSR No. 16.87.1 |
| 16 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, fasteners etc.) As per DSR No. 10.28 |
| 17 | 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required 1.10.1 Group A |
| 18 | 1.14 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 19 | 1.27 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required 1.27.4 6 Module (200mmX75mm) |
| 20 | 1.24.1 5/6 A switch Each |
| 21 | 1.24.5 6 pin 15/16 A socket outlet Each |
| 22 | 8.5 LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt ) Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round / square / Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \\"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector 8.5.2 8 - 10 watt Each 945 |
| 23 | Providing and fixing inaugration black granite (Polished) 20 mm thick stone size 0.90x0.75 cm. including lettering, printing, border etc will be painted of superior quality is required shade and colour including fixing exavation of foundation (1.40x0.50x0.40cm), P.C.C. 1:6:12 (1.40x0.50x0.15cm), brick work 1:3 cement coarse sand up to G.L. (1.40x0.23x1.35cm), 12 mm thick plaster 1:3 cement coarse sand and finihing walls with water proffing white cement paint of approved make and quality such as super snowcem paint etc. all complete. as per analysis Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayOct 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender