Tender For Construction Of Watch Tower At Nimuna Farm, Khordha
Tender Value
12.51 Lakhs
Estimated cost
Bid Submission
21 Oct 2026
13 days left
EMD
12600
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Khordha → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Watch Tower At Nimuna Farm, Khordha
BOQ
| Sl. No. | Item Description |
| 1 | Earthwork in hard soil with initial lead and lift including rough dressing and breaking clods upto 5cm to 7cm size and laying in layers each layer not exceeding 0.3m in depth etc. complete. |
| 2 | Filling in foundation and plinth with sand well watered and rammed including cost conveyance and royalty |
| 3 | Cement Concrete (1:4:8) with 4cm size hard granite metal in Foundation and Plinth. |
| 4 | Brickwork with Fly Ash bricks in cement mortar (1:6) in Super structure in 2nd Floor |
| 5 | RCC wok of M-20 grade with 20mm downgraded size hard granite chips including hoisting and laying complete |
| 6 | Column base & Plingth Beam |
| 7 | Column & Beam structure Gound Floor |
| 8 | 1st Floor |
| 9 | 2nd Floor |
| 10 | 3rd Floor |
| 11 | Roof Slab 2nd Floor |
| 12 | Lintel 2nd Floor |
| 13 | Supplying fitting and placing uncoated HYSD bar reinforcement complete asper drawing and technical specification. |
| 14 | Ground Floor |
| 15 | First Floor |
| 16 | Second Floor |
| 17 | 12 mm thick cement plaster (1:6) to even surface of brick work including watering etc. complete in 2nd Floor |
| 18 | 16 mm thick cement plaster (1:6) to even surface of brick work including watering etc. complete in 2nd Floor |
| 19 | 6 mm thick cement plaster (1:4), finished smooth including closed deep chiping with all complete in 2nd Floor |
| 20 | Wall Priming one coats on new work with wall water bound primer of approved shade as per direction of Engg-in-Charge in 2nd Floor |
| 21 | Finishing walls with Plastic Emulsion paint of approved shade on new work to give even shade 2 coats including cost of paint etc. in 2nd Floor |
| 22 | Wall painting two coats on new work with Weather coat paint of approved shade as per direction of Engg-in-Charge in 2nd Floor |
| 23 | 2.5 cm thick Grading Concrete over roof with C.C. (1:2:2) using 6.7 mm size CBHG chips complete in 2nd Floor |
| 24 | Supplying, fitting & Fixing of vitrified tiles (60cm x 60cm plain/ivory) in floors of approved make confirming to IS : 13755 laid on 20mm thick bed of cement mortar (1:4) & filling joints with white cement with all coplete in 2nd Floor |
| 25 | Fixing of Vitrified tiles 60cmx60cm (Colour/ Printed) series in dado, skirting and risers of steps on 12mm thick cement plaster in mortar (1:3) joined with neat cement slurry complete including cost of tiles in 2nd Floor |
| 26 | Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. |
| 27 | Supplying , fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. |
| 28 | Suppling anf fixing of FRP door in with all complete |
| 29 | Supplying, fitting and fixing of M.S. Grill doors/windows/gates, with all complete |
| 30 | Red Oxide Priming one coat with Red oxide primer of approvedquality etc. complete as per direction of Engg-in-Charge |
| 31 | Enamel Painting two coats with enamel paint of approved quality etc. complete as per direction of Engg-in-Charge in |
| 32 | Cost of internal electrification |
| 33 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider (Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 34 | Group-A, short point |
| 35 | Group-B, medium point |
| 36 | Group-C, long point |
| 37 | Recessed wiring to 5A /6Amp Modular socket outlet with 2 X 1.5sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in recess 20mm dia non metallic PVC flexible conduit with Modular Switch phenolic laminated sheet suitable size ISI marked MS box and earthing point with 1 X1.5sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc. as required (Make of wire -Finolex/ L&T/ Anchor/ Havells/V-Guard/Great White/HPL) (a) Supply & Fixing of 5/6 amp, 3-pin Modular socket with 6 Amp Switch on existing board. |
| 38 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 39 | Wiring of circuit/Recessed Sub-main wiring alongwith earth wire with the following sizes of PVC insulated single core multistrand copper conductor, ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit, 1.6 mm in recessed PVC conduit as required (Make of wire- Finolex/L&T/Anchor/Havells/V-Guard/Great White/Mescab/HPL) |
| 40 | 2 X 1.5 sq.mm + 1 x 1.5 sq.mm |
| 41 | 2 X 2.5 sq.mm + 1 x 1.5 sq.mm |
| 42 | 2 x 4.0 sq.mm. + 1 x 1.5 sq.mm. |
| 43 | 4 X 4sq.mm + 2 X 2.5sq.mm |
| 44 | 2 x 6.0 sq.mm. + 1 x 2.5 sq.mm. |
| 45 | Supplying and fixing of following sizes of medium class PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/ BEC/ Precision/ Norpak |
| 46 | 20 mm |
| 47 | 25 mm |
| 48 | S/F of 4 way single pole and neutral double door sheet Steel MCB Distribution Board (Without MCB)Double door 4 way |
| 49 | S/F of 5 -32 amp rating, 240 volt 'B' series MCB for lighting and other loads in the existing MCB distribution board, ISI marked, complete with connection, testing and commissioning etc. as requierd(make-HPL/ Havells/ Legrand /L&T/C&S). (a)5 - 32 amp SP (SinglePpole) MCB |
| 50 | Supply and fixing of 63 Amp ICDP mainswitch with MS Board |
| 51 | S/F of Ceiling fan, aluminium body, copper winding with accessories & connection without reglator(Make-Crompton/Havells/Usha/eqv.):- 48\\" (1200 mm) fan |
| 52 | S/F of eletronic step type regulator for ceiling fan in existing swich board including connections (Cona/Anchor/eqv. ) |
| 53 | S/F of Bakelite angle holder/batten holder in place of ceiling rose |
| 54 | S/F of 9 watt LED Tube Light (Havels/Phillips/Crompton/Surya) with all complete |
| 55 | S/F Exhaust Fan (300 mm) with all complete (Havels/ Usha/ crompton/ Eqv.) |
| 56 | S/F 18W LED light with all complete |
| 57 | S/ F 6 mm twin core unbonded Aluminium service connection Wire with No.10 GI guard wire for support |
| 58 | Earthing with GI pipe 3.00 Mtr long 40 mm dia. ISI mark including accessories and providing masonary work |
| 59 | Supplaying all materals,labours, taxes and tools and plants for fittings and fixing of PVC pipes,class- confirming to ASTM-D-1785/89(Sch-80) and pipe fittings of the following nominal bore with clamps fittings including making good the wall,ceilling and floor,testing all complite as per specification and direction of the Engineer -in-charge.(a) 25 mm dia PVC Pipe |
| 60 | Cutting grooves in pucca floors and walls for taking CPVC pipe s and making good the damages as per specification and direction of the EIC |
| 61 | Cutting holes through existing brick work for taking CPVC pipe s and making good the damageswith cement morter (1:6) as per specification and direction of the EIC |
| 62 | Cutting holes through existing in R.C.C. Floors and roofs upto 19 cm. for taking CPVC pipe s and making good the damageswith cement voncrete (1:2:4) as per specification and direction of the Engineer -in-charge. |
| 63 | Supplaying all materals,labours, taxes and tools and plants for fittings and fixing of brass screw-down Bib cock(Tapes)/CP fittings conforming to IS:781-1995 ofthe following nominal sizes as per specification complete and direction of the Engineer -in-charge. |
| 64 | 15 mm dia CP BrassShort Body Bib cock . |
| 65 | 16 mm dia CP Brass Long Body Bib cock . |
| 66 | 15 mm dia CP flanges |
| 67 | Supplying all materals,labours, taxes and tools and plants for fittings and fixing of brass screw-down Stop cock / CPittings of the following IS:781-1995 approved make including supplay all nessary jointining material compliteas per specification and direction of the EIC |
| 68 | 15 mm dia CP Brass Stop Cock |
| 69 | Supplying, fitting, fixing of 15 mm dia CP concealed stopcock etc. Complete. |
| 70 | Supplying all materils,labour,T&P and fixing Rotational moulded polithylene cylindrical vertical water storage tanks (SYNTEX)conforming to IS 12701-1996 Including cutting holes through the tank and fixing mild steel tubes and fittings and providinng extra socket and jam nuts,fixing ball valave etc,including hoisting up to a height of extra 5 Meters above ground level and placing the tank to the required position etc, all as per speci fication and directionof the EIC. (a) 500 liter capacity Syntex/FC Tank |
| 71 | Supplying all materials,labour,T&P and fitting, fixining following PVC items and filling of the following outside diameter conformoring to IS 13592 Type A, to walls with seal ring conforming to IS:5382,leaving 10 mm gap for 10mm thermal expansion,(1) single socket pipes as per manufactures specification testing, all complite as per specification and directionof the EIC. |
| 72 | 110 mm dia OD PVC SWR D/S pipe (ISI TYPE B ) |
| 73 | 110 mm dia UPVC door bend |
| 74 | 110 mm dia UPVC plain Tee |
| 75 | 110 mm dia UPVC Cowl |
| 76 | Supplying all materials,labour,T&P and fitting, fixining of Wash down water Closest (Europian type W.C pan) with Integral\\"S\\" or \\"P\\" trap conforming to IS 2556:Part 8-2004, to the floor with Wooden Plug And Chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc,,all complite as per specification and direction of the Engineer incharge. (Without Seat &Cover) |
| 77 | Supplying all materials,labour T &P Fitting of 10 liters capacity PVC L L flushing Cistern with manually controlled device(handle lever) conforming to IS :7231,etc all complite as per specification and direction of the EIC. (a) 10 Liters P.V.C.low level Flushing Cystern |
| 78 | Supplying all materials,labour T &P Fitting of Plastic Seat and cover for wash down water closet with cromium plated brass hinges and rubber buffer etc all complite as per specification and direction of the EIC |
| 79 | Supplying all materils,labour, T&P fitting,fixing of Virtious China flat Wash basin over sizes 550 mm x 400 mm with hole for pillar taps conformoing to IS 2556 : Part 4-2004 with cast iron or M.S Brackets painted white cement including cutting holes in walls and making good the damages etc. All complite as per specificationand direction of the EIC. (a)Virtious China flat wash basin of 550mm x 400 mm (Parryware/Hindustan etc) |
| 80 | Supplying all materils,labour, T & P fitting,fixing of PVC waste pipe for wash basin or sink i.e Flexiable (Coil shaped) PVC Waste pipe 40mm dia with length not less than 700 mm with PVC waste fittings etc. All complite as per specificationand direction of theEIC. (a) Flexible (coil shaped) PVC waste pipe for sink & wash basin 32 mm dia with 900 mm long waste fittings |
| 81 | Fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin complete as per specification |
| 82 | Supplying all materils,labour, T&P fitting,fixing of CP soap Holder standard sizewith wooden plugs CP srew and cement etc. All complite as per specificationand direction of the EIC. |
| 83 | Supplying all materils,labour, T&P fitting,fixing of CP brass towel rail wooden plugs CP srew and cement etc. All complite as per specificationand direction of the EIC. |
| 84 | Supplying all materils,labour, T&P fitting,fixing of plate glass shelf with CP brass brackets wooden plugs CP srew and cement etc. All complite as per specificationand direction of the EIC. |
| 85 | Supplying all materils,labour, T&P fitting,fixing of bevelled type plate glass mirroor with wooden plugs CP srew and cement etc |
| 86 | Supplaying all materals,labours, taxes and tools and plants for fittings and fixing of CP Brass Shower rose with Cp revolving Shower with 15 to 20 mm inlet & 150 mm dia etc compliteas per specification and direction of the Engineer -in-charge. |
| 87 | Supplying all materials,labour and fixing of Brass Full Way Valve conforming to IS: 781-1995 of the 25 mm dia brass ball Valve including all taxes etc complite as per direction by Engineer in charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysOct 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender