Housing Urban and Rular Development Government Departments Closing in 17 days TDR #57861584

Tender For Construction Of Proposed E Type Staff Quarter With Principals Residence (At Ground Floor)For Government Iti, Krushnaprasad In The District Of Puri For Year 2025-26.

Issued by Government Departments · Puri, Odisha
Tender Value
5.91 Crore
Estimated cost
Bid Submission
22 Oct 2026
17 days left
EMD
5.92 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Puri → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Proposed E Type Staff Quarter With Principals Residence (At Ground Floor)For Government Iti, Krushnaprasad In The District Of Puri For Year 2025-26.

BOQ

Name of Work:- Construction of Proposed E Type Staff quarter with Principals Residence (at Ground floor)for Government ITI, Krushnaprasad in the District of Puri for year 2025-26.
Sl. No. Item Description
1CIVIL WORKS Earth work in hard soil or gravelly soil within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per the direction of the Engineer-in-charge.Ground Floor
2Paver Block
3Boundry Wall
4Back filling of excavated earth at foundation including the cost of labour ,T&P etc. complete as directed by the Engineer in Charge.Ground Floor
5Boundry Wall
6Supplying, filling in foundation & plinth with sand in layers including watering and ramming with cost conveyance, royalities, taxes of all materials and labour with T&P required for the work etc. complete Ground Floor
7Paver Block
8Boundry Wall
9Providing & applying Post constrution of Antitermite treatment by drilling 12 mm dia holes at a distance of 30cm@ junction of wall and floor about 300mm apart deep enough to each the soil below and chemical emulsion(PREMISE,IMIDACHLOPRIED 30.5SC OF BAYER MAKE mixed with475 ltr water) pumped these holes to soak the soil @1Ltr solution of each holea as per manufactures specification and the holes should be pluged with filling materials including cost of all materials,labour charges,conveyance and all taxes and hiring charges of machinaries as per direction of Engineer in chargesGround Floor
10Cement concrete of proportion (1:3:6) in foundation and floors using 4cm size black broken granite stone aggregates of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15cm(6\\") thick to the required level ramming, watering, curing etc. complete including cost and conveyance royality taxes of all materials and labour with T&P required for the work etc. complete i as per direction of the Engineer-in-charge.Ground Floor
11Boundry Wall
12300mm dia 8.0 mtr long. Double Under ream Pile foundation with RCC M25 using 12mm size black hard granite chips including cost of boring but excluding the cost of MS/Tor steel and labour charges for cutting, bending, binding of steel.Ground Floor
13Single Under ream Pile foundation with RCC-M20 using 12mm size black hard granite chips including cost of boring but excluding cost of MS/Tor steel and labour charges for cutting , bending and binding of steel. Boundry Wall
14Plain Cement concrete M20 grade using 20mm down graded size h.g chips including cost of all materials etc complete.Ground Floor
15First Floor
16Second Floor
17Third Floor
18Terrace Floor
19Brick work with Flyash bricks 25 Cm. x 12 Cm. x 8 cm having crushing strength not less than 75 Kg/cm2 with dimensional tolerance + 2 percent in cement mortar (1:6) in foundation & plinth.Ground Floor
20Boundry Wall
21Brick work with Flyash bricks 25 Cm. x 12 Cm. x 8 cm having crushing strength not less than 75 Kg/cm2 with dimensional tolerance + 2 percent in cement mortar (1:6) in Super-Structure.Ground Floor
22Boundry Wall
23First Floor
24Second Floor
25Third Floor
26Terrace Floor
27Brick work with Flyash bricks 25 Cm. x 12 Cm. x 8 cm having crushing strength not less than 75 Kg/cm2 with dimensional tolerance +2 percent in cement mortar (1:4) in superstructure.Ground Floor
28First Floor
29Second Floor
30Third Floor
31R.C.C. work M-25 grade with 20mm and down grade black hard granite crusher broken stone chips including hoisting and laying.Pile CapGround Floor
32Grade BeamGround Floor
33ColumnGround Floor
34First Floor
35Second Floor
36Third Floor
37Terrace Floor
38Roof BeamGround Floor
39First Floor
40Second Floor
41Third Floor
42Terrace Floor
43Roof SlabGround Floor
44First Floor
45Second Floor
46Third Floor
47Terrace Floor
48LintelGround Floor
49First Floor
50Second Floor
51Third Floor
52Terrace Floor
53ChajjaGround Floor
54First Floor
55Second Floor
56Third Floor
57Terrace Floor
58Stair caseGround Floor
59First Floor
60Second Floor
61Third Floor
62Terrace Floor
63Shear wallGround Floor
64R.C.C. M-20 grade with 20mm and down grade C.B. chips of approved quality from approved quarry including hoisting, laying hire charges of concrete mixture, vibrator, watering, curing and cost of all materials and labour, T&P centering shuttering etc complete but excluding cost of reinforcement complete as per the direction of Engineer-in-charge.Pile CapBoundry Wall
65Grade BeamBoundry Wall
66ColumnBoundry Wall
67Tie BeamBoundry Wall
68Cooping SlabBoundry Wall
69A/R-P 52/item No.9:Supplying, fitting and placing un-coated HYSD bar reinforcement complete as per drawing and technical specificationGround Floor
70Boundry Wall
71First Floor
72Second Floor
73Third Floor
74Terrace Floor
7512mm thick cement plaster (1:4) over brick with cement punnig for exernal wallGround Floor
76Boundry Wall
7712mm thick cement plaster (1:6) on brick work.Ground Floor
78Boundry Wall
79First Floor
80Second Floor
81Third Floor
82Terrace Floor
8316mm thick cement plaster (1:6) over brick or stone masonry.Ground Floor
84Boundry Wall
85First Floor
86Second Floor
87Third Floor
88Terrace Floor
896mm thick cement plaster (1:4) to R.C.C. surfaces finished smooth including deep chiping and slury treatement.Ground Floor
90Boundry Wall
91First Floor
92Second Floor
93Third Floor
94Terrace Floor
95Finishing plastered surfaces of walls with Cement based Putty & making smooth to receive painting including cost of Birla Putty.Ground Floor
96First Floor
97Second Floor
98Third Floor
99Terrace Floor
100Providing and applying 2 coats plastic emulsion paint of approved quality and shade over a coat of wall primer of approved quality to surfaces (interior) including throughly brushing the surface free from foreign materials, sand papering smooth the intermediate coats, providing necessary putty & primer including of all materials, labour, conveyance, ,, royalties, scaffolding, watering, curing, sundries, tools and plants etc as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use)Ground Floor
101First Floor
102Second Floor
103Third Floor
104Terrace Floor
105Providing and Painting with Two Coats of Acrylic Smooth exterior paint of approved make & shade manufactured by reputed manufacturer like NEROLAC / ASIAN / BERGER / DULOX or equivalent to make an even finished surface over a coat of water bound cement primer in all heights with all scaffolding and staging charges including cost, conveyance, , of all materials, cost of all labours, T & P, sundries etc. as required for the work complete.Ground Floor
106Boundry Wall
107First Floor
108Second Floor
109Third Floor
110Terrace Floor
111Providing & laying granite stone flooring using 20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm & above in Stair Treads and Risers over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443/1972 including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shade, with polishing and rubbing ,forming and nosing,moulding edge including cost of all labour, materials, ,, royalties, loading and unloading, conveyance, sundries, watering and curing, etc. complete as per the direction of the Engineer-in-ChargeGround Floor
112First Floor
113Second Floor
114Third Floor
115Terrace Floor
116Providing & fixing 10 mm thick best quality granite stone tiles of approved quality, colour and size between 0.1 sqm to 0.4 sqm in dado/skirting confirming to IS specifications over 12mm thick cement mortar (1: 3) to proper slope, line and level including cutting to required size and shape, fixing at corners and splays etc. including filling the joints with white cement and colouring pigment to match the colour and shade of stones, cleaning the surface with Oxalic acid and polishing complete including the cost, conveyance, , of all materials, cost of labour, loading, unloading, T&P, etc. complete as per the direction of Engineer-in-Charge.Ground Floor
117First Floor
118Second Floor
119Third Floor
120Terrace Floor
121Supplying, fitting & fixing Vetrified industrial floor Tile of premium grade having thickness 8mm to 10mm confirming to IS 4457 of size 300mmx300mm of with veilcraft (VC/FT ) shield( Scratch free/stain free) with water absorption limit between 0.08% to 3% and conforming to IS : 15622:2006 (Group B Ib). laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge (for New Work only )Ground Floor
122Supplying, fitting & fixing of 8-10 mm thick & size of 600x600 mm vitrified floor tile of with veilcraft (VC/FT ) shield( Scratch free/stain free) with water absorption limit between 0.08% to 3% and conforming to IS : 15622:2006 (Group B Ib). laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge (for New Work only )Ground Floor
123First Floor
124Second Floor
125Third Floor
126Providing & Fixing Vitrified Tiles in Dados skirting and risers of steps on 12 mm thick cement plaster (1:3) Jointed with Neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete as per the direction of Engineer-In-Charge.Ground Floor
127First Floor
128Second Floor
129Third Floor
130Providing & Fixinng factory made 100% Solid WPC (Wood Polymer Composite) - Door Frame 125 mm x 65 mm Single Rebated, made from Wood Polymer Composite (Single Extruded Process) material comparising of virgin PVC polymer of K Value 57-60 (Suspension Grade ), Calcium Carbonate and Natural Fibers Wood Powder/ Rice Husk/ Wheat Husk) and Non toxic additives fabricated with meter Joints after applying PVC solvent Cement & screwed with full body treaded star headed screws having minimum frame density of 780 kg/ cbm & an ISO 9001- 2015 Certified Company, having good screw holding capacity (Screw Withdrawal strength of (Min. 990 N ), Minimum Compressive Strength of 58 N/mm2, Modulus of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof, water/Moisture Proof & Fire retardant & Fixed in position with SS Dash Fasteners / Hold Fast of reuired dia and lenght,, all as per specifications drawings as directed by the Engineer-In-Charge. Material test certificate and authentication should be compulsory provided by the manufacturing companyGround Floor
131First Floor
132Second Floor
133Third Floor
134Supplying fitting & fixing of 32mm thick BWR flash Door shutter using both side pastong of 1mm thick laminated sheet (texture finish) of teakwood beading on edge including cost of all materials,Labour T&P etc.Ground Floor
135First Floor
136Second Floor
137Third Floor
138Supplying, fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.Ground Floor
139First Floor
140Second Floor
141Third Floor
142Supplying, fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.Ground Floor
143First Floor
144Second Floor
145Third Floor
146Providing and fixing of Fixed Glazing with part Top hung of approved make to be fabricated from roll formed sections made of pre-painted steel (base steel as per IS-513 of 0.6 mm thick D quality, galvanized as per IS-277 with zinc of 120 Gm/Sq.mtr) with paint specification being with primer of 5-7 microns and finished paint with polyster paint (Black /Pearl white/ Chocolate Brown) of 12-16 microns alongwith the alkyd backer at the back of 5-7 microns and the sizes of outer frame being of 46x52 mm and with all vertical and horizontal mullions are of 46x70 mm and fixed beadings are of 18x25 mm. Top hung shutter should be of 46 x 46 mm. Accessories / gaskets are to be used as per the manufacturer s supply and specification like handle being made of high grade aluminium powder coated and with nylon receiver and gasket will be made of EPDM. All corner brackets are to be made of CRCA with zinc phosphating. The mullion caps and louvered-clips should be of glass filled nylon. The sections are to be cut to length ,mitre joined with corner bracket and frames are fixed to the concrete/masonry walls by means of self expanding screws and glass to be used of 5 mm reflective with all taxes complete.Ground Floor
147First Floor
148Second Floor
149Third Floor
150Terrace Floor
151Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. including cost of all materials with ,, transportation, all labour, sundries, T&P etc. complete as per direction of Engineer in charge.Ground Floor
152Boundry Wall
153First Floor
154Second Floor
155Third Floor
156Terrace Floor
157Painting two coats of synthetic enamel paint over Iron Works as per approved shade of approved quality over a coat of primer, sand papering, polishing the surface including cost, conveyance, ,, materials, labour, T&P, scaffolding etc. as required for the work complete as per direction of Engineer-in-charge. (The paints and primer are to be approved before procurement and use)Ground Floor
158Boundry Wall
159First Floor
160Second Floor
161Third Floor
162Terrace Floor
163Providing and fixing Stainless Steel (Grade 304) railing made of hollow tubes, channels, plates, etc. including welding, grinding, buffing, polishing, curvaturing and fixing the same with necessary stainless steel nuts & bolts including fixing the railing with necessary accessories and stainless steel dash fasteners, etc. complete in all floors as per the direction of Engineer-in-charge. (Payment will be made on the weight of stainless steel members excluding the accessories such as nuts, bolts, fasteners, etc.)Ground Floor
164First Floor
165Second Floor
166Third Floor
167Terrace Floor
168Supplying Installation testing & commissioning of GFRC (Glass Fiber Reinforced Concrete) Screen/jali of approved make of thickness of 50± 10mm pattern, design and colour of approved make to be fixed on/between RCC/ Block work Column or structural work with Dry Fixing method with appropriate frame work, using fasteners and necessary hardware etc. in Building Facade. The element shall be made from '53grade' Portland Cement make Birla/ 'JK Cement' or equivalent, Quartz,fine Silica Sand, Alkali Resistant Glass fiber make 'OC' or equivalent, Super Plasticisers/Additives make by 'BASF' or equivalent, Polymers make 'BASF' or equivalent and UV reistant Synthetic inorganic pigments shall be used for pigmentation make 'BAYFERROC (Germany) or equivalent. The materials Casting shall take place in Synthetic Rubber/FRP Mould manufacture by Mould/Tool/ Mould grade resin of Revex/ Reckil or equivalent complete including cost, conveyance of all materials, labour, transportation charges etc complete in all respect as per specification and direction of the E-I-C.First Floor
169Second Floor
170Third Floor
171Terrace Floor
172Providing average 25mm thick grading Concrete in C.C ( 1:2:2 ) using 6mm size crusher broken black hard granite chips using 2% water proofing cement compound of approved quality over top of Roof, Terrace, including cost of scaffolding, scraping and cleaning the roof surface and finishing smooth to proper slope and gradient including cost of all materials, conveyance, , and sundries,T&P watering and curing by ponding water over terrace slab etc. complete as per the direction of the Engineer-in-charge.Ground Floor
173Terrace Floor
174Dismantling of Prestressed / Reinforced cement concrete grade M-20 & above including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metresGround Floor
175Carriage of Dismentaling materials from work site to out side with in 8 km lead and lift including all labour as per direction of the Engineer-in-chargeGround Floor
176Supplying and fixing of Pre cast kerb stone of size 600mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984.Paver Block
177Supplying, providing laying in approved layer thickness to line grade cross section and constructing Granular Sub-Base close graded Grading VI as shown in the drawing using crushed stone aggregate conforming to grading specified in (Table 400-I /400-I A) & in accordance with physical requirement in BS 812 Part III, Technical specification Part I/II of specification for road and bridge works MORT&H (4th revision) spreading the same with motor grader of adequate capacity with hydraulic controlled blades & compacting the same with vibratory roller of minimum 80 to 100KN static weight or of equivalent capacity, to achieve minimum required density including full compensation to all operations, all inclusive costs, contigencies, incidentals, involved for finished defect free item of work complete to specification & as directed by the Engineer or his representative to satisfaction.Paver Block
178Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC:SP-63:2018.Paver Block
179Finishing walls with water proofing cement paint of approved shade on new work two coat to give an even shade exculding cost of paint.Paver Block
180Loosening,levelling and compacting original ground supporting embankment to facilitate placement of first layer of embankment scarified to a depth of 150 mm,mixed with water at OMC and compacted by rolling so as to achive minimum dry density as given in table 300-2 for empankment construction.Paver Block
181Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per approved Drawing & Technical Specifications and as per Clause -305 of MoRT&H Specifications for Road & Bridge works (5th Revision).Paver Block
182ELECTRICAL WORK INTERNAL ELECTRICAL WORK Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type (flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.NB:All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. GROUP-A(QTRS)
183GROUP-B(QTRS)
184GROUP-C(COMMON AREA)
185Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
186Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (flame retradant type)) with suitable size modular box & cover(flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
187Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((flame retradant type)) with suitable size modular box & cover(flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
188Supplying,fixing of 2 x 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type)( (flame retradant type)) with suitable size modular box & cover(flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
189Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)
190Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT )
191Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT)
192Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 10 sq. mm copper wire for phase and neutral and 01 no of single core 6 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit . (2x10+1X6)(TO BE USED FOR PRINCIPAL QUARTER)
193Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .
194Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB c of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
195Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor , A catagory ISI marked as approved .as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
196S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
197Sub-Head II (Light fitting Fixture & Fan)Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
198Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery 215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(With fan Regulator)
199S/F of 5 step type Modular electronic Fan Regulator anti bacterial ISI Marked with all connection complete in all respect as per direction of Engineer in charge (Make- Schneider(Zencelo)/ legrand (Myrius)/ Panasonic (vision)
200SITC Of 4Ft surface mounted/suspended Single Piece Constructed CRCA LED TUBE BATTEN required pre-wired terminal one side with body earthing provision - along with mounting of 1No.s Essential Glass T8 Base Tube 2200Lumen Pack,Efficacy >110Lm/W, 20Watt,CRI >=80, PF >0.9, CCT 4K, IP20, 25K Burning Hours Temp -20To45Degree,CE marking RoHS compliance KEMA Keur certificate.(Make: Panasonic/LT/Havells /Philips((TMC502 1xT-LED 22W))/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years.
201SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
202Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved.
203HYBRID SOLAR FOR COMMON AREASupply Installation Testing and Commissioning of 2.5 kVA hybrid Solar Photovoltaic Power Plant having following provision: 6 nos. of panel , C-10 Lead acid solar battery 200Ah , 12 V- 4 Nos. conforming to MNRE specifications as amended, consisting of Mono PERC HALF CUT Crystalline silicon solar cells,necessary protections, earthing, mounted on hot dip GI structure( solar panel bottom height from roof level shall not be less than 300mm, accordingly GI structure to be designed) of suitable strength with following components a complete as arequired: a) Solar Photovoltaic Module of capacity 545Wp or above, manufactured in India, conforming to IS14286 / IEC61215, IS/IEC61730-Part-1,IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 22%. PV modules used in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase , 4 wire, 50Hz +/- 2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree Celcious. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage,frequency..d)Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. asarequired.e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/ conduit lugs and other accessories etc.asrequired. with all required accessories as required as per the direction of Engg-in-charge.Make-Tata/waree/luminous/adani/panasonic. The entire SOLAR system should be Replacement Warranty will be 5 years.
204Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years (RAW DB)
205Supply and fixing of 8 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years (INVERTER DB)
206Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year.
207Supplying and fixing 63 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB FB200 in the existing DB complete with connections as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year.
208Supplying and fixing 63Amps DP 230 volts,10KA C series MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years
209Supplying and fixing 32Amps DP 230 volts,10KA C series MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years
210(Earthing) INSTALLATIONSupplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.
211Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
212Providing and fixing 6 SWG G.I wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge.
213CABLING AND END TERMINATION MAIN AREASupplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 70 sq mm
2144 core x 16 sqmm
215LAYING OF CABLELaying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
216Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
217Supplying and making end termination with double brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 4 core x16 sq mm
2183.5core x 70 sq mm
219Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 50 mm dia
220PANELS S/I/T&Commissioning of CPRI tested LT indoor floor mounted double door with provision of padlock Metering main cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.20X10MM Separate Aluminium Earth bus bar should be installed.. 1 nos of 3P+N Type 1+2 SPD65kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer.Provision of OFF/ON/TRIP indication for all the feeders.Make of SPD- Legrand/Siemens/Schneider/ABB/OBO/DEHN
221Chaneover panelS/I/T&Commissioning of CPRI tested LT indoor floor mounted double door with provision of padlock Metering main cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.20X10MM Separate Aluminium Earth bus bar should be installed.. 1 nos of 3P+N Type 1+2 SPD65kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer.Provision of OFF/ON/TRIP indication for all the feeders.Make of SPD- Legrand/Siemens/Schneider/ABB/OBO/DEHN
222CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWERSupplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
223LIGHTNING PROTECTIONSupply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB
224Supply of Roof conductor holder for parapet- Polyamide Conductor holder. With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB
225Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6. Make-OBO/Dehn/ABB
226Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB
227Supply of Connector: For T cross and parallel connectors. Quickinstallation using hexagonal bolt M10X30 high-grade hot dipgalvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB
228Supply of 1 mtr vertical air terminal with mounting accessorieson the flat surface to meet the requirements of IS/IEC 62305.Tested for Electrical , mechanical and chemical as per IEC62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB
229Supply of Vertical air terminal with accessories:Providing of Air terminalsas per IS-IEC -62305 part-3. Nominal size Ø10/16 mm aluminium rod:2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn/ABB
230Supply for Providing of Stand for Fang Fix system 16 kg with base andclamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn/ABB
231Supply for Providing of Stand for Fang Fix system 16 kg made up of frostresistant concrete. Make-OBO/Dehn/ABB
232Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn/ABB
233Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr HeightFor Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB
234Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB
235Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB
236Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn/ABB
237Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB
238Supply of UL Listed maintenance free ,Low carbon coppercoated earth rod of 3 metre electrode having diameter of 17.2mm with copper coating thickness of 250micron tested as perIEC 62561-2 Make-OBO/Dehn/ABB
239Supply of universal clamp made of SS to connect rod with flatconductor Make-OBO/Dehn/ABB
240Supply of Earth conductivity enhancing mineral compound shall be of 25kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB
241Supply of The above arrangements shall be provided with Heavy dutyearth champer of 5000kg load bearing capacity to ensure thesafety of earthing system Make-OBO/Dehn/ABB
242Installation of The above arrangements including all accessories as per Direction of Engg. In charge.
243EXTERNAL ILLUMINATION WORK (SOLAR STREET LIGHT)Supply of Elegant look 60 W AIO LED Solar Street lights having extruded alluminium housing, 180Wp or more (subjected to final panel backup calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) Mono Crystalline Panel/Laminates fixed on the top of the luminaire housing, maintenance free 12.8 volts 78 Ah or more (subjected to final battery calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) LiFePO4 battery(BIS certified) , BMS, MPPT charge controller, PIR sensor( when there will be no movement the lumens output will be 30% output).The solar panel and battery should be designed to provide 2 days (24 hrs ) back up . The luminaire is having IP 65 protection for critical components, IK 08 and having lumen output of >=11400 lumens and having lumen efficacy not less than equal to190 lm/w) as per LM 79 report third party/central/state govt accredited NABL lab to justify the lumen output & lumen efficacy . Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party central/state govt accredited NABL lab reports to justify the lumen efficacy,luminaire output , IK 08 and IP 65 protection.The Luminaire should be supplied along with adjustable type mounting bracket which can be fitted directly on the pole.The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India and warranty certificate on their company's letterhead by mentioning warranty period as 5 years and necessary aftersales Service will be provided through their tollfree base service network located within 100 KM from the project site. The Solar Street light manufacturer should have own NABL accredieted laborotory. The following test reports must be submitted and approved from SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR for the technical acceptance of the products.1.LM 79 REPORT and LM 80 Report ( from third party/central/state govt accredited NABL lab of AIO solar light) , 2. IK 08 ( from third party/central/state govt accredited NABL lab of AIO solar light ) , 3. IP 65 (Report of third party/central/state govt accredited NABL lab of AIO solar light 4. EN50530 MPPT Efficiency , 5. IEC61547 , 6. IEC61000-3-2 EMC , 7. IEC 60598-2-3 ,8. IEC 62109-1, ( The necessary test reports of third party/central/state govt accredited NABL lab from sl no. 4 to sl no.8 must be submitted for any wattage of AIO solar light )Make-(Philips/Panasonict/Wipro/Crompton/Bajaj/Havells/LT ). NB: The cost includes 5 years CMC including repair/ Maintenance/ replacement of the product in case of any defect.
244Supply of 6 mtr long hot dip galvanized Octagonal pole having base dia of 155 mm and top dia of 70 mm and plate thick ness of 4 mm or more. complete with base plate 260x260x16 mm and 4 nos. Jtype En 8 grade foundation bolts (M24X750 mm) to withstand 180 KM / HR or more wind speed considering the weight & dimension of 1 nos 60 W AIO Solar light to be fitted in the top of the pole .The bidder shall also furnish wind load test report of the solar fixture and wind load test of the pole considering the weight and dimension of 1 no 60 W AIO Solar light to be fitted in the pole to sustain wind speed of 180km/hr or more from third party /central/state govt accredited NABL lab after award of the work.( For solar)(Make - Bajaj/RR ispat//Valmont/Vakrangee/Utkarsh)
245Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge.
246Supplying, Erection, Fixing, connection & testing of 40W LED GATE Light of (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge.
247LIFT SYSTEMSupply,Installation, Testing & Commissioning of of 10 Passenger lift gearless with Machine room Capacity,Elevator S+3(4 STOPS) Floors with ACVVVF drive/Control for constant load of 680 kg ARD greater than equal to 1.5 MPS, SS honeycomb interior ,2hr fire rated door with simplex operation without attendant car position indicators,battery operated alarm bell & emegency light,SS honeycomb finish door finished car interior, recess Granite flooring ,power operated centre opening automatic sliding SS honeycomb finish doors for car entrance & hoist way entrance etc . SS Material shall be of grade SS-304 and thickness not less than 1.2mm.Machine beams,buffer support channels,facia plate including sills pit ladder metal screen in Elevator pit etc.as per specifiaction including cost of (i)Overload detection,(ii)Voice announcement,(iii) Intercom,(iv)Braille Buttons (v) Provision of flat cat 6 cable for CCTVwith all Civil & Electrical works required for installation of Elevator in the existing lift well and machine room,scaffolding ,floor cutting including Fireman's switch complete in all respect.The Elevator should be suitable for physically handicapped person. make:OTIS/Mitsubishi/Johnson/Schindler AS PER ENGINEER IN CHARGE
248MANUAL FIRE ALARM SYSTEMSupply, installation, testing and commissioning of Conventional type Main Fire Alarm Control Panel (FACP), the panel shall be conventional type fire detection and alarm system with capacity of 4 zone complete with all accessories and battery back up for 48 hours in standby mode and 15 minutes in alarm condition. The panel shall have minimum of 80 character display complete accessories. Make-Honeywell /Siemens/ Bosch/ Edward/ NOTIFIER/ GST/ Schneider
249Supplying, installing, testing and commissioning of conventional type Hooter at 85 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication with all accessories etc., complete. Make-Honeywell /Siemens/ Bosch/ Edward/ NOTIFIER/ GST/ Schneider
250Supplying, installing, testing and commissioning of conventional type Manual call point with all accessories complete. Make-Honeywell /Siemens/ Bosch/ Edward/ NOTIFIER/ GST/ Schneider Please Enable Macros to View BoQ information
251Supplying, installing, testing and commissioning of conventional type Manual call point with all accessories complete. Make-Honeywell /Siemens/ Bosch/ Edward/ NOTIFIER/ GST/ Schneider Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57861584
AUTHORITY Government Departments
TENDER VALUE 5.91 Crore
LAST DATE 22-10-2026
Authority
Authority Name Road And Building Department
Work Description Tender for Construction Of Proposed E Type Staff Quarter With Principals Residence (At Ground Floor)For Government Iti, Krushnaprasad In The District Of Puri For Year 2025-26.
Basic Detail
Tender No CCE-Khordha R and B Circle-8-26-27
Bidding Type Tender
Location
City Puri
State Odisha
Key Dates
Publish Date 05 Oct 2026
Submission Date 22 Oct 2026
Open Date 23 Oct 2026
Finance
Tender Value 5.91 Crore
Tender Fee 10000
EMD 5.92 Lakhs
Exemption Available
Document List
1a7cf4cc-2ea1-481c-94d4-b0c609d79641.html
BOQ_612030.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 05, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Oct 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Oct 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

1a7cf4cc-2ea1-481c-94d4-b0c609d79641.html

xls

BOQ_612030.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders