Tender For Improvement Of Ts Barracks Being Used As Jawan Barrack Near Gate No 04 At Bsf C Us Ambassa, 154 Bn Bsf Under Shq Bsf Teliamura
Tender Value
7.48 Lakhs
Estimated cost
Bid Submission
13 Oct 2026
5 days left
EMD
14975
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Khowai → Tripura
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Improvement Of Ts Barracks Being Used As Jawan Barrack Near Gate No 04 At Bsf C Us Ambassa, 154 Bn Bsf Under Shq Bsf Teliamura
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. -All kinds of soil. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :-1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 3 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:-Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 4 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :-cement mortar 1:4 (1 cement : 4 coarse sand) |
| 5 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.-Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 6 | 12 mm cement plaster finished with a floating coat of neat cement of mix :-1:4 (1 cement: 4 fine sand) |
| 7 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour -Old work (one or more coats) |
| 8 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :-Old work (one or more coats) |
| 9 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :-One or more coats on old work |
| 10 | Finishing walls with Acrylic Smooth exterior paint of required shade :-Old work (One or more coat applied @ 0.90 ltr/10 sqm). |
| 11 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.-With cement mortar 1:4 (1 cement : 4 fine sand) |
| 12 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:-Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 13 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.-Size of Tile 600x600 mm |
| 14 | Modified Estimated Cost after using Correction factor on DSR 2023 on acount of GST @ 0.973 |
| 15 | Add Cost Index @ 60% on DSR 2023 |
| 16 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.. Group A |
| 17 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required. |
| 18 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 19 | Supplying and drawing following siizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel PVC conduit as required.1 x 1.5 sq. mm |
| 20 | 2 x 1.5 sq. mm |
| 21 | 3 x 1.5 sq. mm |
| 22 | 2 x 2.5 sq. mm |
| 23 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 24 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.5/6 Amp. Switch |
| 25 | 15/16 A switch |
| 26 | 3 pin 5/6 A socket outlet |
| 27 | 6 pin 15/16 A socket outlet |
| 28 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. |
| 29 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 30 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 31 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole |
| 32 | double pole |
| 33 | Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 °C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 34 | Providing and fixing of 20 watt ,6500 k LED Decorative ultra slim square profile LED lighting fixture with extruded Polycarbonate environmental friendly , energy efficientb ready to use pack directly on ceillng /wall, including round sheet ,connection ,testing and dismantling the existing comlete etc as required. Make- Havells/CG/Phillips/Syska |
| 35 | Supplying & laying of one number XLPE insulated and PVC sheathed , armoured aluminium power cable of 1.1 KV Grade of size 2X16 Sq. MM conf to IS: 7098 (Part-I) in the existing METAL/HDPE PIPE / IN OPEN as required. |
| 36 | Supplying & Laying of one number PVC insulated and PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade (heavy duty)armoured UG electric cable with aluminium conductor of size 2 x 16 sq mm,in ground including excavation and refilling the trench but excluding sand cushioning & protective covering. |
| 37 | Supplying, Installation, testing and commissioning of Step type electronic ceiling fan regulator Socket type and dismaintling the existing complete etc.as required including less cost of dismentle material .make havells/ Anchor |
| 38 | Supplying and fixing of phenolic laminated sheet on existing GI metal box switch board / cover. |
| 39 | Total Cost (BoQ1+BoQ2) |
| 40 | Civil work |
| 41 | Elect work Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysOct 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender