Tender For Repair / Maint/Servicing Of Dg Set, Transformer And Other E&M Items At Various Locations Under Hq 7 Sect annual repair Through annual maintenance contract
Tender Value
Ref. Documents
Estimated cost
Bid Submission
17 Oct 2026
11 days left
EMD
79292
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Churachandpur → Manipur
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Maint/Servicing Of Dg Set, Transformer And Other E&M Items At Various Locations Under Hq 7 Sect annual repair Through annual maintenance contract
BOQ
| Sl. No. | Item Description |
| 1 | SCHEDULE' A' PART-I (DG Set) M&L maintenance and servicing of 125 KVA DG set, water cooled (Make-Kirloskar) complete including draining out engine oil from the sump, flushing the sump and cleaning, replacement of gaskets, fuel filters, oil filters, air cleaner elements and the worn out parts like fuel flexible pipes, nuts, bolts, fuel line etc, filling the starting batteries with electrolyte, applying pertroleum jelly in battery terminals poles, checking of voltage, amps, rpm, fuel, coolant and exhaust leakages, aligment and checking of both engine and alternator part etc including refilling radiator coolant, tightening all the nuts adn bolts to the required torque incl testing in all respect as per directed by Engr-in-Charge (Rate of oil filter, fuel filter and coolant to be paid seperately |
| 2 | M&L maintenance and servicing of 62.5 KVA DG set, water cooled (Make-Kirloskar) complete including draining out engine oil from the sump, flushing the sump and cleaning, replacement of gaskets, fuel filters, oil filters, air cleaner elements and the worn out parts like fuel flexible pipes, nuts, bolts, fuel line etc, filling the starting batteries with electrolyte, applying pertroleum jelly in battery terminals poles, checking of voltage, amps, rpm, fuel, coolant and exhaust leakages, aligment and checking of both engine and alternator part etc including refilling radiator coolant, tightening all the nuts adn bolts to the required torque incl testing in all respect as per directed by Engr-in-Charge (Rate of oil filter, fuel filter and coolant to be paid seperately |
| 3 | M&L maintenance and servicing of 62.5 KVA DG set, water cooled (Make-Kirloskar) complete including draining out engine oil from the sump, flushing the sump and cleaning, replacement of gaskets, fuel filters, oil filters, air cleaner elements and the worn out parts like fuel flexible pipes, nuts, bolts, fuel line etc, filling the starting batteries with electrolyte, applying pertroleum jelly in battery terminals poles, checking of voltage, amps, rpm, fuel, coolant and exhaust leakages, aligment and checking of both engine and alternator part etc including refilling radiator coolant, tightening all the nuts adn bolts to the required torque incl testing in all respect as per directed by Engr-in-Charge (Rate of oil filter, fuel filter and coolant to be paid seperately |
| 4 | Draining out the old engine oil from DG set, cleaning of deposits and rectifing the leakages if any by means of welding, brazing and cleaning of oil tank and filling of new Engine oil complete all as specified and directed by Engr in Charge. Note :- The engine oil shall be measured seprately. |
| 5 | Opening /taking out of fuel injection pump (FIP) of DG Set of any type/make and capacity 20 KVA to 50 KVA disconnection of fuel injector line carrying complete overhauling /servicing of injecor pump, calibration of fuel pump as per manufacturer instruction , assembling of the same with DG Set properly in original position , checking the allignment , making proper fuel connection including renewal of unserviceable/defective minor parts like seal, 'O' ring, gaskit fuel pumpl, gear technometer, bushing technometer cover fuel pump gear housing fuel pump gear etc and testing for smooth operation complete all as directed , after replacement of following major parts if found defected/unserviceable :- Note Following items measured & Paid seperately. |
| 6 | (a) Fuel gear pump |
| 7 | (b) Shaft with fuel drive |
| 8 | All as per item No 7 here in before but 62.5 KVA to 100 KVA |
| 9 | (a) Fuel gear pump |
| 10 | (b) Shaft with fuel drive |
| 11 | Supply and fixing of Oil filter element for suitable size for 100 KVA to 125 KVA DG set |
| 12 | Supply and fixing of Oil filter element with 'O' ring for suitable size for 62.5 KVA |
| 13 | Supply and fixing of Oil filter element with 'O' ring for suitable size for 15 KVA to 30 KVA DG set |
| 14 | Supply and fixing of fuel filter element for suitable size for 62.5 KVA to 125 KVA DG set |
| 15 | Supply and fixing of fuel filter element for suitable size for 15 KVA to 35 KVA DG set |
| 16 | Supply and fixing of Air filter for suitable size for 62.5 KVA to 125 KVA DG set |
| 17 | Supply and fixing of Air filter for suitable size for 35 KVA to 15 KVA DG set |
| 18 | Removal of self starter motor from the DG Set of capacity 20 KVA to 45 KVA of existing make , strip opening the starter for the renewal of minor parts like bush gear, o ring assy, bush set, sealing kit, brush set including assembling and re fixing at site complete all as specified and directed.after replacement of following major parts if found defected/unserviceable :- Note Following items measured & Paid seperately. |
| 19 | (a) Armature |
| 20 | (b) Solenoied switch |
| 21 | (c) Field Coil |
| 22 | All as per item No 18 here in before but 62.5 KVA to 100 KVA |
| 23 | (a) Armature |
| 24 | (b) Solenoied switch |
| 25 | (c) Field Coil |
| 26 | Removal & Renewal of old unserviceable feed pump for fuel injection pump complete assy for various capacity of DG Sets. |
| 27 | S & F in Renewal of fuel shut down solenoied valve kit including taking outold valve assy and making all connection testing for smooth operation in any type DG Set complete all as specified and directed by Engr-in-Charge. |
| 28 | M & L for 'B' check kit of DG set 20 KVA to 50 KVA |
| 29 | All as per item No 28 here in before but 62.5 KVA to 100 KVA |
| 30 | S & F in Renewal , V belt of DG Set 20 KVA to 50 of as per existing make and capacity complete all as directed. |
| 31 | All as per item No 30. here in before but 62.5 KVA to 100 KVA |
| 32 | M & L for top up of coolent in concentrate form rediator of DG Set of any type/Make and capacity , complete all as directed. Make :-Bosch, feelit guard & equalientNote: Measurement shall be done only in concentrate form of coolant. |
| 33 | S & F in Renewal of Fule hose flexible with matalic type from fuel tank to filter, filter to FIP including allied nut bolt washer and coupling for DG set 20 KVA to 50 KVA with and including taking out old hose and making all connection testing for smooth operation all as directd. |
| 34 | All as per item No 33 here in before but 62.5 KVA to 100 KVA |
| 35 | S & F in Renewal of radiator hose pipe suitable both inlet and outlet of 62.5 KVA to 100 KVA DG Set with including taking out old hose and making all connection , testing for smooth operation complete all as directed . |
| 36 | S & F in Renewal of 12 V 150 AH Battery Make : Exide Express/Amoron |
| 37 | S & f in Renewal of battery terminals made of brass , suitable for battery of any type /make and capacity , complete all as directd. |
| 38 | S & F in Renewal of PVC insulated multi stranded copper single core unsheathed cable of size 70 sqmm , 1100 volts grade for battery lead Red snd Black colour and all as directed. |
| 39 | S & F Renewal of burnt /UNSV thermostat with new thermostat alongwith complete assy for DG set connection complete all as specified and directed. |
| 40 | M & L for taking down of existing fuel from fuel tank by means of removing of sludge and sediments deposited inside the fuel tank by repeatedly washing by useing of chemical & detergent with air compressor including rectifing of leakage if found. and refixing the same position as per direction of engineer in charge by testing all as specified and directed. cap 20 KVA to 100 KVA DG Sets. |
| 41 | Opening and taking out of cylinder head 20 KVA to 180 KVA capcity DG Set Renewal of inlet and exhaust valve , valve guide seats and lapping of valve machining job pressure testing i/c replacement of u/s parts reassembling with complete testing as requd . |
| 42 | S & F in replacement of anti viberation mounting pad B series complete all as directed . |
| 43 | S & F distilled water in sealed packing for DG 12 volts battery. |
| 44 | S & F in Renewal of battery charging sets automatic type , fixed in DG set /panel with transformer and rectifire etc including rewiring of faulty control complte all as specified and directed by Engr-in-Charge. |
| 45 | S & F in Renewal of by reconditioning of DG set panel board by means of painting by power coated with proper fixing of nut, bolts, hinges, welding and fixing of necessary door lock set of DG sets of any capacity with handle including double key complete all as specified and directed by Engr-in-Charge. |
| 46 | S & F in Renewal of Automatic voltage Regulator (AVR) suitable for DG Set of 40 KVA to 125 KVA capacity with and including taking out old AVR and making all connection testing for smooth operation complete all as specified and directed .Make : Tavr-20(k) , Stemford. |
| 47 | S & F in Renewal of Rotating diods suitable for DG set of Cap 40 KVA to 500 KVA with and including taking out old diods and making all connection testing for smooth operation complete all as specified and directed . |
| 48 | M & L for opening /taking out of turbo charger of DG Set of 40 KVA to 200 KVA capacity , disconnection of air supply connection pipe etc complete overhauling serviceing of turbo charger replacement of turbo charger repair kit including calibration /testing of turbo charger system complete and re assembling the same fitted with DG set properly in original position checking the alignment making proper all connection testing for smooth operation complete all as directed. |
| 49 | S & F in replacement of Exhaust Muffler of DG Set any type any cap and all as specified and directed by Engr-in-charge. |
| 50 | S & F in replacement of Expension bellow for exhaust of DG Set any type any cap and all as specified and directed by Engr-in-charge. |
| 51 | S & F of MCCB, 200 Amp, 4 Pole , 415 Volts, 25 KA breaking capacity, adjustable thermal and magnetic setting complete all as specified and directed. |
| 52 | Renewal of MCCB, 100 Amp, 4 Pole , 415 Volts, 25 KA breaking capacity, fixed thermal and magnetic setting complete all as specified and directed. |
| 53 | Renewal of MCCB, 63 Amp, 4 Pole , 415 Volts, 25 KA breaking capacity, fixed thermal and magnetic setting complete all as specified and directed. |
| 54 | S & F Renewal of off load change over switch 63 Amp, 4 pole, side operated complete all as specified and directed. |
| 55 | S & F Renewal of off load change over switch 200 Amp, 4 pole, side operated complete all as specified and directed. |
| 56 | S & F Renewal of asbestos rope of 19 mm dia around of the exhaust pipe of diesel engine any cap complete all as specified and directed by Engr-in-Charge. |
| 57 | M & L for Renewal by removal taking out old burnt winding from exhaust fan and winding suitable size of copper wire of exhaust fan, ball bearing motor of any type and size and refixing the same including dismantling and all as specified and directed by Engr-in- charge. |
| 58 | Dismantling alternator assembly of the following capacities incl taking out of worn out windings of Rotor and stator incl rewinding the coils with suitable guage of copper wire, replacement of insulation materials, heat varnishing, replacacement of connecting leads and terminal plates all as required to make serviceable of the DG and including reassembling the same after necessary testing all as directed. The item rate includes shifting of altternatos from location to workshop and back to the installation complete all as directed Note : Copper wire shall be measured & paid separately under relevant item of the schedule. |
| 59 | M&L for copper winding for item No-58above as per existing guage complete all as specified and directed |
| 60 | M&L and Renewal of Radiator water pump assy 320 kvat to 500 kva capacity complete all as specified and directed |
| 61 | S & F fuel cap suitable lock & key type of 62 to 500 KVA DG sets all as specified. |
| 62 | S & F Renewal of fuel shut down brass solionid valve make : cummines |
| 63 | S & F Renewal of fan with moter size 600mm sweep suitable for 62.5kva air coolded DG set. All as specified and directed by engineer in charge. |
| 64 | Supply and fixing hose pipe |
| 65 | Supply and fixing of over flow pipe set |
| 66 | Supply and fixing of fan belt for 125 KVA, 100 KVA, 62.5 KVA, 35 KVA, 30 KVA, 20 KVA, 15 KVA Genr set |
| 67 | SCHEDULE' A' PART-II (Solar Power Plant) Repair & maint of old existing inverter of system voltage 240/360/480 volt by inspecting, repair of replacement of internal part complete along with DC wiring connection PCBs, indicators volts & AMP meters (Digital/Analogue type) and make the inverter functional by connecting to esisting battery bank all as specified and directed Note:- If the inverter is non-repairable then the same shall be replaced with hybrid type inverter of suitable capacity wrt existing system boltage@ Rs. 14,50,000.00 |
| 68 | SCHEDULE' A' PART-II (Transformers) Repair/Maint of 250 KVA Transformers including dismantling of top cover with nuts & bolts and gasket sets, servicing & maintenance of LT & HT bushings incl replace of gusket sets with nuts, bolts and washer complete all as specified. Checking the dielectric strenght of transformer oil, moist presence of moisture, impurities etc and top up oil if required, providing and fixing of new gusket set, cable terminal lungs re-assemble the same after checking/rectification of whole parts of transformer loose conection etc and testiing with entire satisfaction and as per direction of EIC |
| 69 | Repair/Maint of Transformers of various capacity including painting and disconnecting from LT/HT line and reconnecting properly through Lugs and top up of transformer oil and other defects to be rectify as per direction of EIC |
| 70 | Earthing with G.I. earth plate 600 mm / 600 mm / 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt complete all as specified. |
| 71 | supply fixing of lighting arrester three piece nonlinear resistor type for 11 KV overhead line 9 KV (rms) rating 5 KVA |
| 72 | Supply and fixing HT 11 KV, out door type gang operated air-break switch suitable for horizontal or vertical mounting fixed type complete with 9 insulators of rating upto 400 Amps |
| 73 | replacement of silica gel breather of 250 KVA/500KVA transformer |
| 74 | Supply and filling new transformer oil into conservator body/tank of the transformer all as specified and directed(Note:- the transformer oil shall be used for filling of main body tank for toping up as per requirement) |
| 75 | Repair Winding/rewinding with copper coil of transformer, replacement of all meter of various capacity as per directions of EIC Note :- 1. The contractor will attend any breakdown of stand by supply in any location whenever required , rectify the fault and restore the stand by supply with in two days after receipt of complaint. 2. The cost of transportation (to and from) for all kind of necessary eqpt /T&P shall be arranged /brought by contractor to complete the job at site and no extra cost shall be paid to the contractor to this effect. |
| 76 | SCHEDULE' A' PART-III (Ac 1.5/2.0) M&L for complete servicing and repair of Split type AC 1.5/2 Ton capacity incl taking down of air conditioner, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections and re-fixing in the same in position testing complete all as directed by Engr-in-Charge. (Unsv accessories will be measured and paid seperately under respective items of Sch) |
| 77 | Supply only the following items required to incorporate in item No 1.00 above:- Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Split AC 2.0 T capacity |
| 78 | Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Split AC 1.5 T capacity |
| 79 | Fan/blower electric motor single phase 230 V complete for inner unit |
| 80 | Fan/blower electric motor single phase 230 V complete for outer unit |
| 81 | Stratring capacitor of suitable capacity |
| 82 | Running capacitor of suitable capacity |
| 83 | Overload protection of suitable capacity |
| 84 | Drain pipe for Split unit PVC 20mm |
| 85 | Fan blade of suitable size for outer unit. |
| 86 | Remote control kit complete for Split type AC |
| 87 | Condencing unit of Split type AC 1.5/2 Ton capacity with complete accessories (Outdoor type) make: Godrej / LG |
| 88 | Cooling unit complete suitable for 1.5/2 Ton Split type AC with complete accessories (Indoor type) make : Godrej /LG |
| 89 | M&L for complete servicing and repair of Window type AC 1.5/2 Ton capacity incl taking down of air conditioner, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections etc and re-fixing in the same in position testing complete all as directed by Engr-in-Charge. (Unsv accessories will be measured and paid seperately under respective items of Sch) |
| 90 | Supply only the following items required to incorporate in item No 3.00 above:- Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Window AC 2.0 T capacity |
| 91 | Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Window AC 1.5 T capacity |
| 92 | Capacitor of suitable capacity for Window AC 1.5/2 Ton capacity |
| 93 | Auto cut thermostate of suitable capacity for window AC 1.5/2 Ton |
| 94 | Fan blade of suitable size for window type AC unit |
| 95 | Fan/blower electric motor single phase 230 V complete |
| 96 | SCHEDULE' A' PART-IV (RO) M&L for complete servicing and repair of RO Plant of any capacity, servicing and cleaning of all accessories and re-fixing in the same in position, testing complete all as directed by Engr-in-Charge. (Unsv accessories will be measured and paid seperately under respective items of Sch). |
| 97 | Supply only micron cartridge filter sponge 4\\" x 20\\" of 4 micron suitable for existing RO plant complete all as specified and directed. |
| 98 | Supply only micron cartridge filter sponge 2\\" x 10\\" of 4 miron suitable for existing RO plant complete all as specified and directed. |
| 99 | Supply only RO Membrane conceal 75 GLD suitable for existing RO plant complete all as specified and directed. |
| 100 | Supply only RO Membrane conceal 400 GLD suitable for existing RO plant complete all as specified and directed. |
| 101 | SCHEDULE' A' PART-V Submersible Pump M&L for Lifting /lowering unservicable submercible pump assembly completely any type/size up to 30HP along with coloum/delivery pipe of 50/80mm dia after disconnecting the electrical connection from the deep tube well/Dugwell of various depth, segregating components for carrying out repair work such as rewinding of burnt motor and serviceing of pump etc and reassemblying after repair, lowering in to the bore well, including aligning and commissioning complete all as specified and directed. Note (a) Unit rate quoted deemed to include only labour for taking up & lowering the submercible pump from bore well along with delivery pipe complete. (b) Repairs/rewinding of submercible pump shall be measured under relevant items.(c) Replacement of coloumn pipe will be measured and paid separately as in supply only under relevants items. |
| 102 | M&L for transporting the unsv submercible pump set upto 30 HP capacity from site to nearest authorised work shop, dismantling the pump motor assembly and rewinding the burnt motor with same gauge of PVC insulated supper enamelled copper wire as per manufacture's instruction including servicing/overhauling the pump, re-assemblying and brought back to site all as specified and and as directed. |
| 103 | Supply only following spare parts for submercible pump set vertical type up to 30 HP complete all as speified and directed. (a) SS impeller as per existing |
| 104 | b) Thrust bearing as per existing |
| 105 | (c) Thrust plate set as per existing |
| 106 | (d) Sand Guard as per existing |
| 107 | (e) Stainless steel bush as per existing |
| 108 | (f) Pump shaft as per existing |
| 109 | Supply only column pipe 50 mm dia galvanised iron medium grade, 3 meter in length & both ends flanged and duly welded complete all as specified and directed.. |
| 110 | M&L for taking out unserviceable submersible motor upto 30 HP from the existing place and transporting the same to outhorised workshop dismantling and rewinding the burnt motor with suitable gauge of PVC insulated supper enamelled copper wire including re-fixing at same location including aligning and testing, commissioning complete all as specified and directed. |
| 111 | M&L for dismantling and taking out the centrifugal pumping set with motor from the existing foundation for carring necessary repair/ servicing by replacing the unservicable parts including fixing of new coupling (CI/rubber) as per existing all as required at site of work of capacity upto 40 HP, including re-fixing at same location including aligning and commissioning complete all as specified and directed. Note (a) Unit rate quoted deemed to include only labour for tpt and reapir. (b) Spares /rewinding of pump set shall be measured under relevant items. Supply only following spare parts for centrifugal pump set up to 40 HP complete all as speified and directed:- |
| 112 | (a) CI impellers |
| 113 | (b) Diffuser |
| 114 | (c) Neck ring |
| 115 | (d) Shaft bush |
| 116 | (e) Shaft |
| 117 | (f) Roller bearing. |
| 118 | (g) Stuffing box gland. |
| 119 | (h) Bearing 6307/6309/ 6312/7307/7308Make SKF/SBC. |
| 120 | SCHEDULE' A' PART-VI Centrifugal Pump) M&L for taking out worn winding of centrifugal pump motor of capacity upto 40 HP carefully and rewinding the same with existing size of super enamelled copper winding wire ,including necessary varnishing and insulating material baking etc, transportation to workshop and back at site complete all as directed by Engineer-in-Charge. |
| 121 | Taking down/disconnecting the existing unserviceble Star Delta starter of Centrifugal / submersible pump from motor control panels of various pump houses and replace with new Star delta starter of capacity 10 HP to 25 HP, three phase, including making electric connection, complete all as specified and directed. ( Make: C&S / BCH/ L &T) |
| 122 | M&L for repair of starter with disconnecting all electric connections, and replacment of unserviceable parts like contractor, relays, coil etc and connecting to the existing pump set of cap upto 60 HP, including testing complete all as specified and directed. |
| 123 | S&F Submersible cable flat Three core PVC insulated and PVC shedthed industrial copper cable of size 6 Sqmm 1100 Volts for connection from starter to motor complete all as specified and directed. Make: Finolex/ CCI/ Havells. |
| 124 | Preparation of surface for Painting of pump/ motor of any type and any capaicty and Pipe of any dia for complete surfaces for painting applying two coats of synthetic enamel paint over one coat of red oxide primer as per colour code on pump sets including SM/MES No of appropriate size of letters with white paint, complete all as specified and directed by Engineer-in-Charge. |
| 125 | M&L for cleaning of under ground sump, semi under ground sump of capacity 10000 to 50000gallons (Drinking water sump) after bailling out of water from tank & cleaning of all sides of wall , top, bottom with fresh water, with the help of pressure jet pump ( Maxium pressure up to 120 bar ) and vacuum suctioner pump, spray of chemical for anti fungal approved by WHO on all sides of walls after cleaning and applying two coats of white wash on external surfaces and writing date of cleaning on the tank complete all as directed by Engineer - in -charge . |
| 126 | M&L in repair to replacement of shaft with impellar of dosing pump suitable for existing at site and all as specified and as directed. |
| 127 | M&L in repair to replacement of coil 250V, 50 Hz, suitable for dosing pump suitable for existing at site and all as specified and as directed. |
| 128 | M&L in repair to replacement of pump tube suitable for dosing pump suitable for existing at site and all as specified and as directed. |
| 129 | M&L in repair to replacement of white suction/discharge tube of size 3/8\\" suitable for dosing pump suitable for existing at site and all as specified and as directed. |
| 130 | M&L in repair to replacement of furrule of size 1/4\\" suitable for dosing pump suitable for existing at site and all as specified and as directed. |
| 131 | M&L in repair to replacement of connecting nut with adapter of size 3/8\\" suitable for dosing pump suitable for existing at site and all as specified and as directed. |
| 132 | SCHEDULE OF CREDIT Old U/S engine oil |
| 133 | Old U/S fuel gear pump,shaft fuel drive of any size and capacity |
| 134 | Old U/S Armature, solenoied sweitch, field coil of any size and capacity of selfstarter |
| 135 | Old U/S fuel feeding pump, shut down valve kit |
| 136 | Old u/s B Check kit |
| 137 | Old U/S v belt of any size & capacity |
| 138 | Old U/S fuel hose pipe flexible type of any size |
| 139 | Old U/S radiator hose pipe of any size |
| 140 | Old U/S battery of any size |
| 141 | Old U/S battery terminals |
| 142 | Old U/S 70 sqmm copper cable single core |
| 143 | Old U/S thermostate, RPM cable,water temp gauge, oil pressure gauge, oil temp meter, HCT Switch, LLOP Switch of any type |
| 144 | Old U/S battery charging set of any size |
| 145 | Old U/S AVR of any size |
| 146 | Old U/S MCCB of any size |
| 147 | Old unsv copper scrap |
| 148 | Old u/s compressor unit any type any size |
| 149 | Old u/s fan/blower motor any type any size |
| 150 | Old u/s capacitor /relay/thermostate switch any type any size |
| 151 | Old u/s cooling unit any type any size |
| 152 | Old u/s condensing unit any type any size |
| 153 | Old u/s remote control kit any type |
| 154 | Old U/S RO Membrane of any type. |
| 155 | Old u/s spares obtained from repair of submersible pump set complete |
| 156 | Old u/s spares obtained from repair of centrifugal pump set complete |
| 157 | Old unsv earthing material |
| 158 | Old u/s GI coloum pipe 50/80mm dia any type |
| 159 | Old u/s submersible cable any type any size Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysOct 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender