Tender For Providing Medical Gas Pipe Line Arrangements For The Work Of Construction Of 50 Bedded Critical Care Block Building At Government Hospital, Mettupalayam In Coimbatore District.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Oct 2026
15 days left
EMD
34000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Coimbatore → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing Medical Gas Pipe Line Arrangements For The Work Of Construction Of 50 Bedded Critical Care Block Building At Government Hospital, Mettupalayam In Coimbatore District.
BOQ
| Sl. No. | Item Description |
| 1 | Oxygen manifold arrangements of 2 banks x 12 cylinder each wing with semi automatic control panel which includes contact gauge 2 Nos., outlet pressure gauge, brass heavy duty IO x regulator 2 Nos. with suitable adopter, flexible SS Hose. Mainfold shall be of a construction and of a designs and material suitable for the service pressure in accordance with IS 1282-1989. Emergency alarms with illuminating display for low / high pipeline pressure and malfunctioning of system. 1) Mainfold top frame with provision for connecting 12 cylinders on right bank and 12 cylinders on left bank with high pressure interconnecting copper tubing, silver brazing, non return valve, fasteners and cylinder spport middle angle frame for claping 2 x 12 cylinders and related fasteners. The O2 manifold should with stand a pressure of 140 kg. / CM2. The installation is commissioned after testing as per standards and painted as per International Code and as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification. |
| 2 | Nitrous Oxide Manifold Arrangements of 2 banks x 3 cylinder each wing, with automatic control panel which includes contact gauge 2 Nos., outlet pressure gauge, brass heavy duty IOX regulator 2 Nos. with suitable adopter, flexible SS hose. Mainfold shall be of a construction and of a designs and material suitable for the service pressure in accordance with IS 1282-1989. Emergency alarams with illuminating display for low / high pipeline pressure and malfunctioning of system. 1) 2 x 3 cylinder Nitrus Oxide Manifold should be suitable with stand a pressure of 140 Kg. / Cm2 and above along with high pressure copper annealed tail pipes with end brass adapter suitable for Nitrous Oxide Cylinders and manifold. 2) Top frame comprising of high pressure copper pipes of size 12mm ID 1.5mm wall thick with high pressure brass fittings made of high tensile brass and connections through non-return valves, high pressure copper tail pipes made of high pressure copper pipe size of 7mm ID x 1.5mm thick. 3) The design of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely with fitted heavy duty regulator. The Manifold should be tested at 3500 pig as per IS 12827 / 1989 & ISO 7396 / 1987 Specification. |
| 3 | Medical Gas Copper Pipeline arrangement to hang on the wall of socket type connection installation of seamless cleaned and degreased non arsenical phosphorous gas copper pipe line with saddles complete with brazing work including all copper fitting (tee, elbow, reducer, coupling). The copper pipelines should be tested suitable for a steam of working pressure of 17.34 kg. / cm2 (17 bar) and confirm to BS 864 Standard with specially made for brazed socket type connection. The medical gas copper pipeline should be tested as per standard and commissioning after painting as per International Code No. IS 2379/1963 Table-V. The pipelines installed at the various wings and floors etc., complete as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification. |
| 4 | 10mm OD 0.90mm thick copper pipe |
| 5 | 15mm OD 0.90mm Thick Copper Pipe |
| 6 | 22mm OD 0.90mm Thick Copper Pipe |
| 7 | 28mm OD 0.90mm Thick Copper Pipe RM |
| 8 | Brass Isolation Valve suitable for the copper pipe and should be of non lubricated 90 degree turn lever ball valve of reputed make, conneced in line with medical gas pipe line system by using suitable size brass valve adopter union, ferrule, nipple, rubber O' ring, tapion lap and etc. All pipe line regulators shall be capable of controlling pipe line pressure and must compatible with the requirements specified in IS 12827-1989. All valves should be pneumatically tested for twice the workingpressure for the gas line as per IS Code 12827 / 1989 & ISO 7396 / 1987 Sepecification. |
| 9 | 22mm Isolation Valve |
| 10 | 15mm Isolation Valve |
| 11 | Supply, erection, testing and commissioning of Pressure Gauge with 0 to 14 kg. range of reputed make with necessary valve, milling thread MS coupling fixed at delivery pipe line in pump house to read the developing pressure including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. |
| 12 | Flow Meter made up of Brass with Humidifier Bottle Flow Meter should be back pressure compressed and should be accurate gas flow measurement with control range 0-13 litres per minute. It should meet strict permission and dumbling standard. The meter body should be made of brass materials. The humidifier bottle should be made of unbreakable polycorbonate material and auto cleavable at 134 degree centigrate. The rate includes flow meter and its accessories (silicon tube with mask). The cost of materials including transport, etc., complete as per standard specification and as directed by the Departmental Officer and as per IS 12827 / 1989 and ISO 7396 / 1987 Specification. |
| 13 | Theatre Vaccum Unit: The unit should comprise of two reusable 2000 ml shatter resistant bottle. Each made up of ply carbonate material and fully autoclavable at 134 degreee centigrade, should have a vacuum regulator with instant ON / OFF switch and tree way left, right or both. All the above items should be mounted on a trolley having free moving castor wheels. (As per IS 12827 / 19898 & ISO 7396 / 1987) |
| 14 | Ward Vaccum Unit with Gauge both mounted on a collection jar of capacity 600 ml and with a wall bracket for mounting it on the wall. The collecion jar should be made of unbreakable polycarbonate materials which is fully auto cleavable at 134 degree centigrade as per standard specification and as directed by the Departmental Officers and as per IS 12827 / 1989 and ISO 7396 / 1987 Specification. The rate includes cost of silicon hose with SS nipple on either side. |
| 15 | Gas Outlet Points: (Self sealing type - Single / DIN outlet pipe) with 'S' type bracket made up of copper and the out let of non-interchangeable for other gas. The outlet points are brazed with brass bracket with self sealing valve (Stainless Steel) with all accessories and complete set and are covered by plastic cover duly colour coated as per specific gas and button cover etc., complete as directed by the Departmental Officers and as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification. |
| 16 | Bed Head Panel of size 1m length, height 0-0.30 cm and depth of 4. The aluminium powder coated withrequirement colour for provision points of O2-2 Nos., Air 1 No., Vaccum 1 No. with double electrical socket with switch 2 Nos. with 2 set with 1V - bottle holder fixing to the wall hanging including monitor stand etc., complete. |
| 17 | Supply, installation, testing and commissioning of Reciprocating Air Cooled Type (10 HP) Rating Vaccum Pump as per following provisions. As per IS 12827 / 1987 & ISO 7396 / 1987 Specificationa) Vaccum Pump - 10 HP - 1 No.b) Electric Motor - 10 HP - 1 No.c) DOL Starter with OLR - 1 No.d) Vaccum Switch - 1 No.e) Vaccum Gauge - 1 No.f) Control Frame with Fittings - 1 No.g) Suction Scrubber - 1 No.h) V-Belts - 1 No.i) GI & MS Fittings - 1 No.j) Brass Fittings - 1 No.k) Exhaust Silencer - 1 No.i) Base Frame for Motor and Vaccum Pump - 1 setm) Pilot Line with Fittings - 1 set,Vaccum Room & Air Compressor Room Inside |
| 18 | Supply, installation, testing and commissioning of MS Fabricated Vertical Mounted Type 1000 liters capacity Vaccum Receiver with inlet and outlet and drain holes provided suitable to operate with vaccum pump, etc., as directed by the Departmental Officers. |
| 19 | Supply, installation, testing and commissioning of Compressed Air System of Reciprocating Oil Free Air Compressor Belt Driven Type 10 HP Air Compressor with following provisions. As per IS 12827 / 1987 & ISO 7396 / 1987 Specification Compressor package consists of following:a) 10 HP Air Compressor - 1 No.b) Electric Motor 10 HP - 1 No.c) Dol Starter - L&T - 10 HP - 1 No.d) Base Frame Kit (for Motor and Compressor) - 1 sete) Pressure Swith - 1 No.f) Pressure Gauge - 1 No.g) NRV and Pilot Fittings - 1 No.h) Delivery Tube - 1 Noi) Foundation Bolts & Anchor Fasteners - 1 Lotj) Belt Guard - 1 No.k) Refrigerator Type Air Dryer-40 cfm. capacity-1 No.l) Drain Ball Valve - 1 No.m) Air Outlet Ball Valve - 1 No.Vacuum Room & Air Compressor Room Inside Accessories: on-Return Valves, Air Pressure Switch, Pressure Gauge, Isolation Valves, Air Filters etc., Inter connecting piping: Mild Steel Pipe of 2 with fittings. |
| 20 | Supply, installation, testing and commissioning of MS Fabricated Vertical Mounted Type 1000 liters capacity Compressed Air Receiver with inlet and outlet and drainholes provided suitable to operate with vaccum pump etc as directed by the Departmental Officers. |
| 21 | GST 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysOct 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents