Defence Statutory Bodies & Commissions/Committees Closing in 26 days TDR #57858307

Tender For Repair/ Maintenance Ht Switch Gears, Relays, Vcb, Rmu, Ht Cables, Ht Joint, God, Structures And Connected Works In Eastern & Western Area Under Ge Hisar At Hisar Mil Stn

Issued by Statutory Bodies & Commissions/Committees · Hisar, Haryana
Tender Value
70 Lakhs
Estimated cost
Bid Submission
31 Oct 2026
26 days left
EMD
1.30 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hisar → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/ Maintenance Ht Switch Gears, Relays, Vcb, Rmu, Ht Cables, Ht Joint, God, Structures And Connected Works In Eastern & Western Area Under Ge Hisar At Hisar Mil Stn

BOQ

Name of Work:- REPAIR/ MAINT HT SWITCH GEARS, RELAYS, VCB, RMU, HT CABLES, HT JOINT, GOD, STRUCTURES AND CONNECTED WORKS IN EASTERN & WESTERN AREA UNDER GE HISAR AT HISAR MIL STN
Sl. No. Item Description
1Disconnecting the existing incoming & outgoing connections and inspection, servicing, overhauling, testing, checking and calibration of VCB panel, 11 kV, vertical or horizontal isolation, installed with VCBs and connected relays/ accessories including servicing, cleaning, tightening of loose mechanical mechanism, greasing, inspection of busbar, CTs/PTs, internal wiring of control panel, indicators, measuring of IR value, calibration of IDMT relays, replacement of unserviceable spare parts, testing of tripping system, to maintain desired insulation level of each panel and removing all type of dust and settled dirt by mechanical means including testing complete all as specified and as directed the followings: -(a) Cleaning of Vacuum Circuit Breaker with CRC-226.(b) Removal of old grease and re-greasing the same with recommended grease(c) To check the condition of SIC contacts.(d) Checking condition and alignment of jaw contact.(e) Checking and proper tightening of hardware.(f) Checking of proper closing/ open of all poles.(g) Checking of breaker tripping through push button.(h) Checking and adjusting gap between hylem sheet and side plate.(i) Checking motor operation in case of EDO.(j) Checking auxiliary contacts continuity proper change over.(k) Checking of presence of circlips.(l) Checking IR between phase to phase (VCB closed condition).(m) Checking IR between phase to earth (VCB closed condition).(n) Checking IR between phase to earth (VCB open condition).(o) Cleaning and providing lubricants on movable mechanical parts.(p) Testing of relays through secondary injections.(q) Tripping of VCB through Buchholz relay/ OTI/WTI if required.(r) Testing of CTs and PT.(s) Testing of contact resistance of VCBs(s) Contact resistance Test (CRM) testing of VCBs. Please Enable Macros to View BoQ information
2Disconnecting the existing incoming & outgoing connections and inspection, servicing, overhauling, testing, checking and calibration of VCB panel, 11 kV, vertical or horizontal isolation, installed with VCBs and connected relays/ accessories including servicing, cleaning, tightening of loose mechanical mechanism, greasing, inspection of busbar, CTs/PTs, internal wiring of control panel, indicators, measuring of IR value, calibration of IDMT relays, replacement of unserviceable spare parts, testing of tripping system, to maintain desired insulation level of each panel and removing all type of dust and settled dirt by mechanical means including testing complete all as specified and as directed the followings: -(a) Cleaning of Vacuum Circuit Breaker with CRC-226.(b) Removal of old grease and re-greasing the same with recommended grease(c) To check the condition of SIC contacts.(d) Checking condition and alignment of jaw contact.(e) Checking and proper tightening of hardware.(f) Checking of proper closing/ open of all poles.(g) Checking of breaker tripping through push button.(h) Checking and adjusting gap between hylem sheet and side plate.(i) Checking motor operation in case of EDO.(j) Checking auxiliary contacts continuity proper change over.(k) Checking of presence of circlips.(l) Checking IR between phase to phase (VCB closed condition).(m) Checking IR between phase to earth (VCB closed condition).(n) Checking IR between phase to earth (VCB open condition).(o) Cleaning and providing lubricants on movable mechanical parts.(p) Testing of relays through secondary injections.(q) Tripping of VCB through Buchholz relay/ OTI/WTI if required.(r) Testing of CTs and PT.(s) Testing of contact resistance of VCBs(s) Contact resistance Test (CRM) testing of VCBs. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57858307
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 70 Lakhs
LAST DATE 31-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance Ht Switch Gears, Relays, Vcb, Rmu, Ht Cables, Ht Joint, God, Structures And Connected Works In Eastern & Western Area Under Ge Hisar At Hisar Mil Stn
Basic Detail
Tender No CWE/HSR/T-28 OF 2026-27
Bidding Type Tender
Location
City Hisar
State Haryana
Key Dates
Publish Date 03 Oct 2026
Submission Date 31 Oct 2026
Open Date 02 Nov 2026
Finance
Tender Value 70 Lakhs
Tender Fee 1000
EMD 1.30 Lakhs
Exemption Not Available
Document List
8868tender.pdf
BOQ_888325.xls
d1c93b28-59ac-439c-ace6-724daa7f43ca.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 26 days
Nov 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 28 days

Tender Documents

Download All (ZIP) ↓
pdf

8868tender.pdf

xls

BOQ_888325.xls

html

d1c93b28-59ac-439c-ace6-724daa7f43ca.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders