Tender For Provn Of Certain special Repair Work Of Certain Units At Mil Stn Jamnagar Under Ge(A) Jamnagar.
Tender Overview
Project Description
Tender for Provn Of Certain special Repair Work Of Certain Units At Mil Stn Jamnagar Under Ge(A) Jamnagar.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-Oct-2026 | AMENDMENT TO BOQ | BOQ | 26-Oct-2026 |
| 2 | 26-Oct-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 02-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down cement plaster on brick or concrete surfaces including racking out joints hacking for keys scrubbing down with water etc complete all as specified and as directed. |
| 2 | Demolition Cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level complete all as specified and as directed. |
| 3 | Demolition Cement Concrete (reinforced) of any description and in any position not otherwise specially provided for (overhead RCC tanks) complete all as specified and as directed. |
| 4 | M&L rendering 15mm thick on fair faces of wall of brick masonary or concrete surfaces in cm 1:3 finished fair and even without using extra cement with integral water proofing compound as per manufacturer instructions complete all as specified and as directed. |
| 5 | M&L for Prepration of newly plastered on walls by hand held sander / long handle sander including cornices, pilasters etc complete all as specified directed and applying three coat of white wash over a coat alkali resistant primer on walls complete all as specified and as directed. |
| 6 | M&L 15 mm thick rendering on other than fair faces of external wall of brick masonary or concret surfaces in CM 1:4 finished fair and even without using extra cement complete all as specified and as directed. |
| 7 | M&L for inspecting the complete site by authorized company applicator and follow following steps :- (a)Prepare the newly plastered surface by hand held sander / long handle sander (b) appliying Smart periodical with company applicatior by Airless spray two or more coats of 100 % premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (company Depot Tinted) with silicon additives @1.43 litre/10Sqm over and including priming coat of exterior primer applied @ 0.9 ltr/10sqm complete all as specified and directed by Engr- In - Charge. Note :- (1) the repair of craks and plaster shall be paid and measured separately. (2) Company aplicator should provide warrany and MTC for the paint as per manufacturer instructions |
| 8 | M&L for complete removal of existing treatment by hand held sander / long handle sander including cornices, pilasters etc by jet washer and applying three coat of white wash on walls over a coat of alkali resistant primer on old plastered surfaces all as specified directed |
| 9 | M&L 5 mm thick rendering on ceiling or concrete surfaces in cm 1:3 finished complete all as specified and as directed. |
| 10 | M&L for Prepration by hand held sander / long handle sander including cornices, pilasters etc of newly plastered on ceiling complete all as specified directed and applying three coat of white wash, complete all as specified and as directed. |
| 11 | M&L for inspecting the complete site by authorized company applicator and follow following steps :- (a)complete removal of existing tretment by hand held sander / long handle sander and washing down with Jet washer (b) repair cracks and wall plaster as per site requirement and prepare the surface (c) appliying Smart periodical with company applicatior by Airless spray two or more coats of 100 % premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (company Depot Tinted) with silicon additives @1.43 litre/10Sqm over and including priming coat of exterior primer applied @ 0.9 ltr/10sqm complete all as specified and directed by Engr- In - Charge. Note :- (1) the repair of craks and plaster shall be paid and measured separately. (2) Company aplicator should provide warrany and MTC for the paint as per manufacturer instructions |
| 12 | Complete removal of existing roof treatment, removing rubbish off the premises, cleanning the surface and preparing to receive new roof treatment and applying roof treatment as under:- (a) Applying coat of bituminios primer @ 0.40 litre/ Sqm on prepared surfaces and allow to dry(the primer and the membrane to be used shal be of same manufacturer, (b) Supply and laying of minimum 3 mm thick APP modified polymeric membrane weighting not less than 3 KG/ Sqm black finish reinforcement with non woven polyster matt with help of torching with proplane or abutance gas using torch with minimum 75 mm side overlap and 100 mm end overlap. (c) two coat of approved aluminium paint over membrane complete. (d) all overlaps and joints shall be sealed as per manufacturers instruction complete all as specified and directed. |
| 13 | Roughening surfaces of old concrete surfaces by picking, sweeping clean and washing down with water to remove dust, etc incl brushing neat cement slurry with 3.0 kg of cement per sq metre complete all as specified and as directed. |
| 14 | M&L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed. |
| 15 | M&L for Rendering 10mm thick in CM(1:3) with using water proofing compound on fair faces of brick work/ Fasia and roof surface finished even and smooth without using extra cement complete all as specified and directed. |
| 16 | M&L PCC 1:2:4, type B0 (using 12.5mm size stone aggregate) as levelling course complete all as specified complete all as specified and as directed. |
| 17 | M&L for 75mm thick cement concrete Type C-2 ,1:3:6,( Using 40mm graded aggregate) as in plinth protection , subbase complete all as specified and directed by Engr-in-charge. |
| 18 | Taking up or down steel tubing and connections of bore of pipe 25 mm complete all as specified and as directed. |
| 19 | Supplying and laying of 25 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape in any requirement complete to walls and ceilings or laid in floors iincluding all connected brass cpvc fittingsand cutting grooves, filled with CM1:6 complete all as specified. |
| 20 | Taking up or down steel tubing and connections of 40 mm bore of pipe complete all as specified and as directed. |
| 21 | Supply and fixing 40mm steel water tubing medium grade , galvanised , with all fittings and fixed complete fixed to walls and ceillings or laid in floors complete all as specified and as directed. |
| 22 | Refixing old steel water tubing of dia 40mm or 50mm and connections in new or old position (walls , celling, floors etc) complete all as specified and as directed. |
| 23 | Dismantling exc 250 & n exc 500 ltrs water tanks and removing from site complete all as specified and as directed. |
| 24 | S & F in 500 liters rotaional moulded polyethylene water storage tank, double layered (cylindrical vertical with closed top cover) as per IS-12701-1996 and PTMT 20mm ball valves/ float valve high pressure with epoxy aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weight 20mm - 210 gms) , hoisted and fixed in position including necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc, complete as specified in SSR Part-I complete all as directed by Engr -in-charge. |
| 25 | Dismantling exc 500 & n exc 100 ltrs water tanks and removing from site complete all as specified and as directed. |
| 26 | S & F in 1000 liters rotaional moulded polyethylene water storage tank, double layered (cylindrical vertical with closed top cover) as per IS-12701-1996 and PTMT 20mm ball valves/ float valve high pressure with epoxy aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weight 20mm - 210 gms) , hoisted and fixed in position including necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc, complete as specified in SSR Part-I complete all as directed by Engr -in-charge. |
| 27 | S&F in repairs 25 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe/upvc pipe complete all as specified and as directed. |
| 28 | S&F in repairs 40 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe/upvc pipe complete all as specified and as directed. |
| 29 | S&F in repairs PVC(SWR) pipe 110 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, fixed to wall complete all as specified and as directed. |
| 30 | S & F PVC (SWR) junction single (single T) equal or unequal 110mm bore, with access door complete all as specified and directed by Engr-in-charge. |
| 31 | S&F in repair PVC (SWR)110 mm bore bends any radius complete all as specified and as directed. |
| 32 | M&L for cement concrete 1:2:4 type B-0 (using12.5 mm graded aggregate) as in sub base of floors , mass concrete complete all as specified and directed by Engr in charge. |
| 33 | M&L for racking of cracks upto 5 mm wide ,preparation and crack filling with ready to use crack fiber reinforced filler /chemical based crack fillers by approved manufacturer and filling as per manufacturer instructions in walls,roofs of any type or size (Make: Pidilite/dr fixit,fosroc, or equivalent) complete all as specified and as directed. |
| 34 | Removal of all loose/unsound/bad/damaged concrete or plaster existing RCC structure of slab/beams/walls/chajja by using chesel/hammar .Cut and remove unsound reinforcement bars, wires etc without damaging the sound reinforcement . clean loose rust from bars manually with brush . fixing new supplymentary bars if required,either by tying it with existing bars or by welding on it. Applying eppoxy bonding agent and making good with polymer modified plaster/micro concrete as required thickness over a coat of rust removing alkaline primer and match the finishing to the existing surface in ground floor including formwork complete all as specified and directed. |
| 35 | Supply only of Intergral water proofing compound as per manufactures instruction complete all as specified and as directed. |
| 36 | S&F framed work such as grills, gratings, etc with ends of bars shouldered and / or riveted , or forged into spikes; framed guard bars; barred irondoors; ladders; framed balusters; walk ways; railings ; framework of water tanks and similar work confirming to Fe 290 Gde E165 complete all as specified and as directed. |
| 37 | M&L RCC 1:2:4 Type B-1 (20mm aggregate) nominal mix as Slabs supported on walls, beams and columns in floors, roofs, etc. complete all as specified and directed by Engr-in-charge. |
| 38 | M&L for Formwork to flat soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engr-in-charge. |
| 39 | S&F Mild steel bars (TMT bars) 10 mm and above, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engr-in-Charge. |
| 40 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and as directed. |
| 41 | M&L for 18-20mm thick Kota stone slab machine cut, in stair treds, bathroom platforms, shelf platforms etc. bedded and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing complete over and including 15 mm thick screed bed in CM 1:4 and polishing complete all as specified and directed by Engr-in-charge. |
| 42 | M&L for 18-20mm thick Kota stone slab machine cut, in riser of steps, skirting, dado and pillar etc. bedded and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing complete over and including 10 mm thick screed bed in CM 1:3 and polishing complete all as specified and directed by Engr-in-charge. |
| 43 | M&L for Brickwork with fly ash moudular bricks built in CM (1:4) , straight or curved on plan exc 6m mean radius, complete all as specified and directed. |
| 44 | Demolition of brick work or stone/boulder masonary built in CM including all quoins, arches, pillars, etc but excluding ashlar, facing, dressed stone work and pre-cast concrete articles complete all as specified and as directed by Engineer-in-Charge |
| 45 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 46 | M&L for 25mm thick bitumen mastic linning work with bitumen primer coating as per manufacturer instructions complete all as specified and directed by engr in charge. . Note - the rates includes all necessary arranagement for preparing and heating bitumen for flooring etc as per site requirement complete all as specified and as directed. |
| 47 | S&F steel window or ventilators , fixed type with glazing bars complete all as specified and as directed. |
| 48 | S & F stainless steel wire cloth 0.36mm dia of wire and avarage width of aperture 1.40mm and fixed with stainless steel wire staple in any type of windows/doors complete all as specified and directed by Engineer-In-Charge. |
| 49 | Taking down chowkats with shutter (without taking off shutters from the frames) n exc 1.0 sqm each, complete all as specified and directed. |
| 50 | M&L for cement concrete 1:2:4 type BO (using12.5mm graded aggregate) in cills, steps, seismic and other similar bands plinth coureses string courses lacing courses parapets and railing copings kneelers apex bed plates kerbs. etc. water troughs and the like including wethering slightly rounded or chamfered angles and throating as directed |
| 51 | M&L for rendering 10mm thick on fair faces on brick masonary or concrete surfaces in cm 1:6 finished even and fair complete all as specified and directed. |
| 52 | M&L 15 mm thick rendering on other than fair faces of external wall of brick/ stone / block masonary or concret surfaces in two layers Ist layer shall be 10mm in cm 1:6, secound and final layer shall be 5mm thick in CM 1:4 finished fair and even without using extra cement mixed with integral water proofing compound complete all as specified and directed. |
| 53 | M&L Prepration of newly plastered surface of wall by hand held sander / long handle sander including cornices, pilasters etc and appliying with Airless spray two or more coats of 100 % premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (company Depot Tinted) with silicon additives @1.43 litre/10Sqm over and including priming coat of exterior primer applied @ 0.9 ltr/10sqm complete all as specified and directed. |
| 54 | M&L for Prepration by hand held sander / long handle sander including cornices, pilasters etc of old plastered wall complete and applying one coat of white wash, complete all as specified and directed. |
| 55 | M&L complete removal of existing tretment by hand held sander / long handle sander washing down with Jet washer and appliying Airless spray two or more coats of 100 % premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (company Depot Tinted) with silicon additives @1.43 litre/10Sqm over and including priming coat of exterior primer applied @ 0.9 ltr/10sqm complete all as specified and directed. |
| 56 | M&L for 75mm thick cement concrete Type C-2 ,1:3:6,( Using 40mm graded aggregate) as in plinth protection , subbase complete all as specified and directed by Engr-in-charge. |
| 57 | M & L PCC 1:3:6 type C2 (using 40mm graded stone aggregates) as in sub base, flooring , mass concrete etc complete all as specified and directed. |
| 58 | M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade conforming to IS 15658-2006 with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. |
| 59 | M&L for Hardcore of gauge n exc. 63 mm (broken stone or boulders) , deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 60 | S&F in repairs for Steel rolling shutters with thickness of lath 1.0 mm, gear operated type with bevelled gear box and and crank handle, without ball bearing, as specified including top cover, an choring rod, hasp and staple and one shop coat of primer; erected in position as indi cated, complete all as specified and directed. |
| 61 | M & L PCC 1:4:8 type C2 (using 40mm graded stone aggregates) as in sub base, flooring , mass concrete etc complete all as specified and directed. |
| 62 | S&F in repairs for safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed. |
| 63 | S&F in repairs for ball bearing for rolling shutters complete all as specified and directed. |
| 64 | M&L preparation of old Steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed. |
| 65 | M&L preparation of new untreated Steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome complete all as specified and directed. |
| 66 | S&F powder coated anodised aluminium alloy sections 3 tier track sliding windows series B of size 92mm x 31.75mm x 1.2mm and shutter section 18mm x 43mm x 1.30mm weight 0.547 kg/m Jindal or equivalent duly fitted with neoprene beading, glazing clips, tinted glass panes 4.80/5.0 mm nominal thickness, stainless steel wire cloth 0.36 mm dia and average width of aperture 1.4 mm, aluminium alloy handles etc including taking down old window in any size and make. complete all as specified and directed.Note : rate shall include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangements, handle etc |
| 67 | Removal of existing sand filling in floors and removing sand to directed area exc 50m and n exc 500m and dipositing where directed by engr in charge |
| 68 | Excavation in post hole each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, and getting out soft soil complete all as specified and directed |
| 69 | Dismantling posts or struts (wood , steel or RCC ) any section , including taking out embedded portion and making good disturbed ground embedded in concrete , brick work , masonary etc complete all as specified and directed. |
| 70 | M&L for cement concrete 1:3:6 type C-2 (40mm aggregate) columns , pillar and posts etc. complete all as specified and directed by Engr in charge. |
| 71 | S&F mild steel work in angle iron in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, and similar works confirming to Grade E-165 (Fe 290) complete all as specified and directed. |
| 72 | S&F mild steel screw bolts (machine made) with hexagonal or spuare heads at one end and screwed the other, or screwed to both ends, each screwed end to be fitted with washers and one hexagonal or square nut , exc 5cm but nexc 10 cm long and dia of neck 5 mm to 10mm complete all as specified and as directed. |
| 73 | Supply and fixing for mild steel galvanised chain link fencing 3.15 mm dia of mesh wire and mesh opeing size 100 x 100mm with straining bolts, 10 mm dia round bars binding with 0.9mm dia MS binding wire, flat iron fillets ( for securing wire mesh etc. ), binding and jointing complete including necessary drilling, bolting or revetting etc. complete all as specified and as directed. Note:- Flat iron, round bars, nut bolts, and waashers etc, shall be measured as supply only and paid seperately. |
| 74 | S&F mild steel plates, plain or chequered, 5 mm thick or over in thickness in available sizes conforming to Fe-410-W(Gde E-250) Quality B complete all as specified & directed. |
| 75 | Supply only mild steel round bars 6mm to 8 mm Fe-410 W(Gde E-250) , cut to shae , bend to shape required , including cranking , bending spirally for hopping ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips complete all as specified & directed. |
| 76 | Dismantling fencing wire mesh any type any size complete all as specified & directed. |
| 77 | Excavation in trenches n exc 1.50m wide and n exc 1.50m deep and getting out in soft/ loose soil complete all as specified & directed. |
| 78 | M&L 15 mm thick rendering on fair faces of external wall of brick masonary or concret surfaces in cm 1:6, finished fair and even without using extra cement complete all as specified & directed. |
| 79 | Returning, filling in, including spreading, levelling, waterning and well ramming in layers not exceeding 25cm thick , complete all as specified & directed. |
| 80 | Removing excavated material n,exc 50 m and depositing where directed at a level n, exc 1.5m above the starting point complete all as specified & directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender