Power Government Departments Closing in 0 days TDR #57857063

Tender For Purchase of Various Class Isolators for year 2025-26 2026-27 as per latest technical specification on firm price basis against tender no. ACE(P C)/SE(P C)/EE(Proc)/III/E-3085/ Various Class Isolators/2025-26 2026-27

Issued by Government Departments · Vadodara, Gujarat
Tender Value
136.36 Crore
Estimated cost
Bid Submission
26 Oct 2026
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
11800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Vadodara → Gujarat
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Purchase of Various Class Isolators for year 2025-26 2026-27 as per latest technical specification on firm price basis against tender no. ACE(P C)/SE(P C)/EE(Proc)/III/E-3085/ Various Class Isolators/2025-26 2026-27- 400kv,3150a, hdb tandem isolator without eb with structure with cl connector as per technical specification.(1) one side suitable for 4 ips sch 80 al. tube and other side twin moose (450mm spacing) (220v dc-9 set), 400kv,3150a, hdb isolator with eb with structure with cl connector as per technical specification.(1) one side rigid type and other side expansion type suitable for 4 ips sch 80 al. tube (220v dc-3 set), 400kv,2000a, hdb tandem isolator without eb with structure with cl connector as per technical specification.(1) one side suitable for 4 ips sch 80 al. tube and other side twin moose (450mm spacing) (220v dc-6 set), 400kv,2000a, hdb isolator without eb with structure with cl connector as per technical specification. (1) one side rigid type and other side expansion type suitable for 4 ips sch 80 al. tube (220v dc-2 set), 400kv,2000a, hdb isolator with eb with structure with cl connector as per technical specification (1) one side rigid type and other side expansion type suitable for 4 ips sch 80 al. tube (220v dc-1 set), 220kv,1600a, hdb tandem isolator without es with structure with cl connector as per technical specification (1) twin moose (350mm spacing) universal take off (220v dc-32 set)(2)twin al-59 (350mm spacing) universal take off (220v dc-2 set), 220kv,1600a, hdb isolator without es with structure with cl connector as per technical specification (1) twin moose (350mm spacing) universal take off (220v dc-45 set)(2) twin al-59 (350mm spacing) universal take off (220v dc-3 set)(3) twin moose (350mm spacing) universal take off (110v dc-52 set)(4) twin zebra (350mm spacing) universal take off (110v dc-6 set, 220v dc-7 set), 220kv,1600a, hdb isolator without es without structure with cl connector as per technical specification (1) twin zebra (350mm spacing) universal take off (110v dc-6 set)(2) twin moose (350mm spacing) universal take off (220v dc-120 set), 220kv,1600a, hdb isolator with es with structure with cl connector as per technical specification.(1) twin moose (350mm spacing) universal take off (220v dc-4 set), 220kv,1600a, hdb isolator with es without structure with cl connector as per technical specification.(1) twin moose (350mm spacing) universal take off (220v dc-40 set), 132kv,1600a, hdb isolator without es with structure with cl connector as per technical specification.break up:(1) twin zebra (350mm spacing) universal take off (110v dc-15 set & 220v dc-2 set)(2) twin al-59 (350mm spacing) universal take off (110v dc-5 set)(3) single moose (110v dc-5 set), 132kv,1600a, hdb isolator with es with structure with cl connector as per technical specification.(1) twin zebra (350mm spacing) universal take off (110v dc-2 set), 132kv,1600a, hdb isolator without es without structure with cl connector as per technical specification.(1) twin zebra (350mm spacing) universal take off (110v dc-27 set), 132kv, 1600a, hdb isolator with es without structure with cl connector as per technical specification.(1) twin zebra (350mm spacing) universal take off (110v dc-18 set), 66kv, 2000a hdb isolator without eb with structure with cl connector as per technical specification.break up:(1) zebra (110v dc-173 set for bus section)(2) twin al-59 (350mm conductor spacing)- (220v dc-2 set for bus section)(3) twin zebra (350mm conductor spacing) - (110v dc-32 set & 220v dc-30 set) for xmer bay(4) twin moose (350mm conductor spacing) - (110v dc-3 set & 220v dc-9 set) for xmer bay, 66kv, 1250a hdb isolator with eb w/o structure with cl connector as per technical specification.break up:(1) panther (110v dc -278 set)(2) zebra (110v dc-433 set)(3) twin zebra (350mm conductor spacing) - (220v dc-8 set), 66kv, 1250a hdb isolator with eb with structure with cl connector as per technical specification.break up:(1) panther (220v dc-4 set)(2) panther (110v dc-210 set) with u/g cable support arrangement(3) panther (110v dc-282 set)(4) al-59 (220v dc-15 set)(5) zebra (110v dc-18 set), 66kv, 1250a hdb isolator without eb with structure with cl connector as per technical specification.break up:(1) panther (110v dc-1448 set, 220v dc-4 set)(2) twin zebra (350mm conductor spacing) - (110v dc-10 set, 220v dc-2 set)(3) zebra (110v dc-78 set) (4) al-59 (220v dc-25 set), 66kv, 1250a, hdb isolator without eb without structure with cl connector as per technical specification.break up:(1) zebra (110v dc-461 set) (2) twin zebra (350mm conductor spacing) - (220v dc-16 set), 22kv, 630a, hdb isolator with eb without structure with cl connector as per technical specification.(1) panther - (110v dc-7 set), 22kv, 630a, hdb isolator without eb without structure with cl connector as per technical specification(1) panther - (110v dc-12 set), 22kv, 630a, hdb isolator with eb with structure with cl connector as per technical specification(1) panther - (110v dc-16 set), 22kv, 630a, hdb isolator without eb with structure with cl connector as per technical specification(1) panther - (110v dc-21 set)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 N/A 26-Oct-2026

BOQ

Sl. No. Item Name
1400kv,3150a, hdb tandem isolator without eb with structure with clamp connector as per technical specification.(1) one side suitable for 4\\" ips sch 80 al. tube and other side twin moose (450mm spacing) (220v dc-9 set)
2400kV,3150A, HDB Isolator with EB with structure with clamp connector as per Technical Specification.(1) One side rigid type and other side expansion type suitable for 4\\" IPS Sch 80 Al. Tube (220V DC-3 Set)
3400kV,2000A, HDB Tandem Isolator without EB with structure with clamp connector as per Technical Specification.(1) One side suitable for 4\\" IPS Sch 80 Al. Tube and other side Twin Moose (450mm spacing) (220V DC-6 Set)
4400kV,2000A, HDB Isolator without EB with structure with clamp connector as per Technical Specification. (1) One side rigid type and other side expansion type suitable for 4\\" IPS Sch 80 Al. Tube (220V DC-2 Set)
5400kV,2000A, HDB Isolator with EB with structure with clamp connector as per Technical Specification (1) One side rigid type and other side expansion type suitable for 4\\" IPS Sch 80 Al. Tube (220V DC-1 Set)
6220kV,1600A, HDB Tandem Isolator without ES with structure with clamp connector as per Technical Specification (1) Twin Moose (350mm spacing) Universal take off (220V DC-32 Set)(2)Twin AL-59 (350mm spacing) Universal take off (220V DC-2 Set)
7220kV,1600A, HDB Isolator without ES with structure with clamp connector as per Technical Specification (1) Twin Moose (350mm spacing) Universal take off (220V DC-45 Set)(2) Twin AL-59 (350mm spacing) Universal take off (220V DC-3 Set)(3) Twin Moose (350mm spacing) Universal take off (110V DC-52 Set)(4) Twin Zebra (350mm spacing) Universal take off (110V DC-6 Set, 220V DC-7 Set)
8220kV,1600A, HDB Isolator without ES without structure with clamp connector as per Technical Specification (1) Twin Zebra (350mm spacing) Universal take off (110V DC-6 Set)(2) Twin Moose (350mm spacing) Universal take off (220V DC-120 Set)
9220kV,1600A, HDB Isolator with ES with structure with clamp connector as per Technical Specification.(1) Twin Moose (350mm spacing) Universal take off (220V DC-4 Set)
10220kV,1600A, HDB Isolator with ES without structure with clamp connector as per Technical Specification.(1) Twin Moose (350mm spacing) Universal take off (220V DC-40 Set)
11132kV,1600A, HDB Isolator without ES with structure with clamp connector as per Technical Specification.Break up:(1) Twin Zebra (350mm spacing) Universal take off (110V DC-15 Set & 220V DC-2 Set)(2) Twin Al-59 (350mm spacing) Universal take off (110V DC-5 Set)(3) Single Moose (110V DC-5 Set)
12132kV,1600A, HDB Isolator with ES with structure with clamp connector as per Technical Specification.(1) Twin Zebra (350mm spacing) Universal take off (110V DC-2 Set)
13132kV,1600A, HDB Isolator without ES without structure with clamp connector as per Technical Specification.(1) Twin Zebra (350mm spacing) Universal take off (110V DC-27 Set)
14132kV, 1600A, HDB Isolator with ES without structure with clamp connector as per Technical Specification.(1) Twin Zebra (350mm spacing) Universal take off (110V DC-18 Set)
1566kV, 2000A HDB Isolator without EB with structure with clamp connector as per Technical Specification.Break up:(1) Zebra (110V DC-173 Set for Bus section)(2) Twin AL-59 (350mm conductor spacing)- (220V DC-2 Set for Bus section)(3) Twin Zebra (350mm conductor spacing) - (110V DC-32 Set & 220V DC-30 Set) for X'mer bay(4) Twin Moose (350mm conductor spacing) - (110V DC-3 Set & 220V DC-9 Set) for X'mer bay
1666kV, 1250A HDB Isolator with EB w/o structure with clamp connector as per Technical Specification.Break up:(1) Panther (110V DC -278 Set)(2) Zebra (110V DC-433 Set)(3) Twin Zebra (350mm conductor spacing) - (220V DC-8 Set)
1766kV, 1250A HDB Isolator with EB with structure with clamp connector as per Technical Specification.Break up:(1) Panther (220V DC-4 Set)(2) Panther (110V DC-210 Set) with U/G Cable support arrangement(3) Panther (110V DC-282 Set)(4) AL-59 (220V DC-15 Set)(5) Zebra (110V DC-18 Set)
1866kV, 1250A HDB Isolator without EB with structure with clamp connector as per Technical Specification.Break up:(1) Panther (110V DC-1448 Set, 220V DC-4 Set)(2) Twin Zebra (350mm conductor spacing) - (110V DC-10 Set, 220V DC-2 Set)(3) Zebra (110V DC-78 Set) (4) AL-59 (220V DC-25 Set)
1966kV, 1250A, HDB Isolator without EB without structure with clamp connector as per Technical Specification.Break up:(1) Zebra (110V DC-461 Set) (2) Twin Zebra (350mm conductor spacing) - (220V DC-16 Set)
2022kV, 630A, HDB Isolator with EB without structure with clamp connector as per Technical Specification.(1) Panther - (110V DC-7 Set)
2122kV, 630A, HDB Isolator without EB without structure with clamp connector as per Technical Specification(1) Panther - (110V DC-12 Set)
2222kV, 630A, HDB Isolator with EB with structure with clamp connector as per Technical Specification(1) Panther - (110V DC-16 Set)
2322kV, 630A, HDB Isolator without EB with structure with clamp connector as per Technical Specification(1) Panther - (110V DC-21 Set)

AI Tender Summary

OUR REF NO 57857063
AUTHORITY Government Departments
TENDER VALUE 136.36 Crore
LAST DATE 26-10-2026
Authority
Authority Name Gujarat Energy Transmission Corporation Limited
Work Description Purchase of Various Class Isolators for year 2025-26 2026-27 as per latest technical specification on firm price basis against tender no. ACE(P C)/SE(P C)/EE(Proc)/III/E-3085/ Various Class Isolators/2025-26 2026-27- 400kv,3150a, hdb tandem isolator without eb with structure with cl connector as per technical specification.(1) one side suitable for 4 ips sch 80 al. tube and other side twin moose (450mm spacing) (220v dc-9 set), 400kv,3150a, hdb isolator with eb with structure with cl connector as per technical specification.(1) one side rigid type and other side expansion type suitable for 4 ips sch 80 al. tube (220v dc-3 set), 400kv,2000a, hdb tandem isolator without eb with structure with cl connector as per technical specification.(1) one side suitable for 4 ips sch 80 al. tube and other side twin moose (450mm spacing) (220v dc-6 set), 400kv,2000a, hdb isolator without eb with structure with cl connector as per technical specification. (1) one side rigid type and other side expansion type suitable for 4 ips sch 80 al. tube (220v dc-2 set), 400kv,2000a, hdb isolator with eb with structure with cl connector as per technical specification (1) one side rigid type and other side expansion type suitable for 4 ips sch 80 al. tube (220v dc-1 set), 220kv,1600a, hdb tandem isolator without es with structure with cl connector as per technical specification (1) twin moose (350mm spacing) universal take off (220v dc-32 set)(2)twin al-59 (350mm spacing) universal take off (220v dc-2 set), 220kv,1600a, hdb isolator without es with structure with cl connector as per technical specification (1) twin moose (350mm spacing) universal take off (220v dc-45 set)(2) twin al-59 (350mm spacing) universal take off (220v dc-3 set)(3) twin moose (350mm spacing) universal take off (110v dc-52 set)(4) twin zebra (350mm spacing) universal take off (110v dc-6 set, 220v dc-7 set), 220kv,1600a, hdb isolator without es without structure with cl connector as per technical specification (1) twin zebra (350mm spacing) universal take off (110v dc-6 set)(2) twin moose (350mm spacing) universal take off (220v dc-120 set), 220kv,1600a, hdb isolator with es with structure with cl connector as per technical specification.(1) twin moose (350mm spacing) universal take off (220v dc-4 set), 220kv,1600a, hdb isolator with es without structure with cl connector as per technical specification.(1) twin moose (350mm spacing) universal take off (220v dc-40 set), 132kv,1600a, hdb isolator without es with structure with cl connector as per technical specification.break up:(1) twin zebra (350mm spacing) universal take off (110v dc-15 set & 220v dc-2 set)(2) twin al-59 (350mm spacing) universal take off (110v dc-5 set)(3) single moose (110v dc-5 set), 132kv,1600a, hdb isolator with es with structure with cl connector as per technical specification.(1) twin zebra (350mm spacing) universal take off (110v dc-2 set), 132kv,1600a, hdb isolator without es without structure with cl connector as per technical specification.(1) twin zebra (350mm spacing) universal take off (110v dc-27 set), 132kv, 1600a, hdb isolator with es without structure with cl connector as per technical specification.(1) twin zebra (350mm spacing) universal take off (110v dc-18 set), 66kv, 2000a hdb isolator without eb with structure with cl connector as per technical specification.break up:(1) zebra (110v dc-173 set for bus section)(2) twin al-59 (350mm conductor spacing)- (220v dc-2 set for bus section)(3) twin zebra (350mm conductor spacing) - (110v dc-32 set & 220v dc-30 set) for xmer bay(4) twin moose (350mm conductor spacing) - (110v dc-3 set & 220v dc-9 set) for xmer bay, 66kv, 1250a hdb isolator with eb w/o structure with cl connector as per technical specification.break up:(1) panther (110v dc -278 set)(2) zebra (110v dc-433 set)(3) twin zebra (350mm conductor spacing) - (220v dc-8 set), 66kv, 1250a hdb isolator with eb with structure with cl connector as per technical specification.break up:(1) panther (220v dc-4 set)(2) panther (110v dc-210 set) with u/g cable support arrangement(3) panther (110v dc-282 set)(4) al-59 (220v dc-15 set)(5) zebra (110v dc-18 set), 66kv, 1250a hdb isolator without eb with structure with cl connector as per technical specification.break up:(1) panther (110v dc-1448 set, 220v dc-4 set)(2) twin zebra (350mm conductor spacing) - (110v dc-10 set, 220v dc-2 set)(3) zebra (110v dc-78 set) (4) al-59 (220v dc-25 set), 66kv, 1250a, hdb isolator without eb without structure with cl connector as per technical specification.break up:(1) zebra (110v dc-461 set) (2) twin zebra (350mm conductor spacing) - (220v dc-16 set), 22kv, 630a, hdb isolator with eb without structure with cl connector as per technical specification.(1) panther - (110v dc-7 set), 22kv, 630a, hdb isolator without eb without structure with cl connector as per technical specification(1) panther - (110v dc-12 set), 22kv, 630a, hdb isolator with eb with structure with cl connector as per technical specification(1) panther - (110v dc-16 set), 22kv, 630a, hdb isolator without eb with structure with cl connector as per technical specification(1) panther - (110v dc-21 set)
Basic Detail
Tender No ACE (P C)/TN-15/26-27
Bidding Type Tender
Location
City Vadodara
State Gujarat
Key Dates
Publish Date 01 Jan 0001
Submission Date 26 Oct 2026
Open Date 01 Jan 0001
Finance
Tender Value 136.36 Crore
Tender Fee 11800
EMD Ref. Documents
Exemption Not Available
Document List
1.ALLBGFormat11.03.24.pdf
2.AuthorisedDeclarationFormat11.03.24.pdf
3.PACopy.pdf
332211KVISOR4June22.pdf
4.LandBoarderCertificateA1.pdf
400220132kVDBTandemIsolatorR6June22.pdf
5.LandBoarderCertificateA2.pdf
6.CommercialTermsandConditions.pdf
66kVIsolatorR6June22.pdf
85f67064204f4a899d66caca86b98808.html
Addendumterminalconnector10.06.2025.pdf
AmendmentStructureweight.pdf
AmmendmentforTTRvalidity26.02.2026.pdf
ScheduleAE3085.pdf
TerminalConnectorsR2June22.pdf
TSSSSTRR1211.03.2024.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 26, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Oct 26, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Today
Oct 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today

Tender Documents

Download All (ZIP) ↓
ALLBGFormat11

1.ALLBGFormat11.03.24.pdf

AuthorisedDeclarationFormat11

2.AuthorisedDeclarationFormat11.03.24.pdf

PACopy

3.PACopy.pdf

pdf

332211KVISOR4June22.pdf

LandBoarderCertificateA1

4.LandBoarderCertificateA1.pdf

pdf

400220132kVDBTandemIsolatorR6June22.pdf

LandBoarderCertificateA2

5.LandBoarderCertificateA2.pdf

CommercialTermsandConditions

6.CommercialTermsandConditions.pdf

pdf

66kVIsolatorR6June22.pdf

html

85f67064204f4a899d66caca86b98808.html

06

Addendumterminalconnector10.06.2025.pdf

pdf

AmendmentStructureweight.pdf

02

AmmendmentforTTRvalidity26.02.2026.pdf

pdf

ScheduleAE3085.pdf

pdf

TerminalConnectorsR2June22.pdf

03

TSSSSTRR1211.03.2024.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender