Petroleum and Natural Gas Boards / Undertakings / PSU Closing in 11 days TDR #57851089

Bids Are invited for Custom Bid For Services - Kandla- Dyke Drain Valve And Instrumentation Works - S/L Cab 12Px1.5Mm2cables :Supplying, Laying; Testing And Commissioning Of 1.1 Kv Grade Cables ;Pvc Insulated (Fire Retardant Low Smoke) ; Pvc Sheathed

Issued by Boards / Undertakings / PSU · Kachchh, Gujarat
Tender Value
38.15 Lakhs
Estimated cost
Bid Submission
24 Oct 2026
11 days left
EMD
30000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kachchh → Gujarat
EMD Exemption
Available
Quantity
1

Project Description

Bids Are invited for Custom Bid For Services - Kandla- Dyke Drain Valve And Instrumentation Works - S/L Cab 12Px1.5Mm2cables :Supplying, Laying; Testing And Commissioning Of 1.1 Kv Grade Cables ;Pvc Insulated (Fire Retardant Low Smoke) ; Pvc Sheathed; Armoured Copper Conductor Cables Of Following Sizes As Per Is:1554 (Part-I), And Sealed Properly With Pvc Caps In Built-Up Ready Made Trenches; Overhead Cable Trays;Pull Through Pipes Or Exposed On Wall .Beam/Rakes; Trusses Tie/Beamor Embedded In Floor Or Buried Directly Underground (Excavation, Sand And Bricks Shall Be Paid Under Seperate Item Of Boq) Or Through G. I.Pipe.Unit Rates Quoted For Installationof Cables Shall Be Same Irrespective Of Route And Method Of Laying. The Rates Shall Include Laying, Pulling Of Cables, Proper Dressing Of Cables On Cable Trays, Racks, Vertical Raceways And Supply And Installation Of Saddles, Spacers And Nylon Chord For Tying As Required,Identification Tags At Strategic Points/ Every 50 Meter Intervales,Aluminium Cl S. Etc. Cable Identification Tags At Strategic Points/ Every 50 Meter Interval For Identification Of Cable; Etc. Complete.The Straight Through Joints/ Tying With Armour In The Cables Should Be Avoided.Procedure For Laying Of Lt Cables.Makes/Specifications , S/L Cab 2Px1.5Mm2cables :Supplying, Laying; Testing And Commissioning Of 1.1 Kv Grade Cables ;Pvc Insulated (Fire Retardant Low Smoke) ; Pvc Sheathed; Armoured Copper Conductor Cables Of Following Sizes As Per Is:1554 (Part-I), And Sealed Properly With Pvc Caps In Built-Up Ready Made Trenches; Overhead Cable Trays;Pull Through Pipes Or Exposed On Wall .Beam/Rakes; Trusses Tie/Beamor Embedded In Floor Or Buried Directly Underground (Excavation, Sand And Bricks Shall Be Paid Under Seperate Item Of Boq) Or Through G. I.Pipe.Unit Rates Quoted For Installationof Cables Shall Be Same Irrespective Of Route And Method Of Laying. The Rates Shall Include Laying, Pulling Of Cables, Proper Dressing Of Cables On Cable Trays, Racks, Vertical Raceways And Supply And Installation Of Saddles, Spacers And Nylon Chord For Tying As Required,Identification Tags At Strategic Points/ Every 50 Meter Intervales,Aluminium Cl S. Etc. Cable Identification Tags At Strategic Points/ Every 50 Meter Interval For Identification Of Cable; Etc. Complete.The Straight Through Joints/ Tying With Armour In The Cables Should Be Avoided.Procedure For Laying Of Lt Cables.Makes/Specifications , Dyke Drain Sil Certified Proximity Switch , 12 Cs#150 Gate Valve , S/I 9M Da Octa Polesupply, Installation, Testing And Commissioning Of The Following Types Of Gi Octagonal Poles For Street Lights With The Sizes Of The Poles Given Below Including Provision Of Holes For Cable Entry, Earthing Points On Poles, Base Template, Grouting Bolts All Civil Works Like Excavation, Pcc, Supply And Fixing Of Cable Protection Pipes Disposing Of Surplus Earth, Providing Shoring, Shuttering And Dewatering, If Required And Including Supply Of Cement, Steel, Pipes, Base Plates, Paint And All Sundry Materials Including All Materials And Labour. Street Light Fittind Would Be Measured And Paid Under Seperate Item Of Boq. Civil Work To Be Paid Seperately. , Excv<1.5 Ord Dis In Earth Work In Excavation Upto Required Depth Below Existing Ground Level Upto Required Depth Including Removal Of Vegetation,Shrubs And Debris Cutting And Dressing The Sides In Slopes And Bottom, Levelling, Grading And Ramming Of Bottoms, Bailing Out Of Water , Supplying Of Temporary Supports To Existing Services Line Like Water Pipes,Sewage Pipes,Electric Overhead And U/G Cables Etc All If Encountered, Shoring, Strutting And Disposal Of Excavated Earth Anywhere Inside Bpcls Premises As Directed By The Engineer In Charge, Complete. Payment Shall Be Made As Per The Actual Measurement But Not More Than Excavation Plan.Also No Payment Would Be Made For Extra Excavation For Making Slopes Etc.The Excavated Earth To Be Spread In Loose 150 Mm Thick Layers, Watered, Rolled Andwell Consolidated Using Suitable Compactors.The Density To Be Achieved Shall Not Be Less Than 90% Of The Density Obtained In The Laboratory (Modified Proctor Method) (Payment Against This Item Shall Be Released Only For The Earth Being Disposed Inside Bpcl Premises) , Rcc Plin 1:1.5:3 Cssupplying And Laying In Postion Rcc Of Specified Nominal Mix Using 20Mm Anddown Size Graded Crushed Stone Aggregate In Sub Structure Of All Types E.G. Trenches, Culverts, Manholes, Pipe Encasement, Catchpits, Drains, Pits, Etc.,Including Placing Of Concrete,Supplying Pockets,Openings, Recesses,Chamfering Wherever Required Etc., Vibrating, T Ing, Curing Andrendering If Reqd. To Give A Smooth And Even Surface Etc. All Complete(Excluding The Cost Of Reinforcement, But Including The Cost Of Centringand Shuttering)For All Depths Below And Upto Plinth Level In Any Shape,Position, Thickness Etc. All Complete As Specified And Directed. Onlysteel Shuttering Will Be Used So As To Obtain Required Finish. Theheight Of Shuttering Shall Not Exceed 1.5 M Per Lift Of Concrete.: 1:1.5:3 (1 Cement: 1.5 Coarse Sand: 3 Grade Stone Aggregate 20 Mm Nominal Size) , Supplying And Placing Hysd Steel Reinforcement Of Grade 500 (Tmt) Conforming To Is 1786 In Position For Rcc Worksincluding Straightening, Cutting, Bending, Placing In Position Andbinding With 16 Swg Black Soft Annealed Binding Wire At Everyintersection, Supplying And Placing Appropriate Cover Block All Completeincluding Cleaning And Making It Free From Oil, Grease Etc. Complete-For All Heights And Depths And Conforming To Relevant Is Code (Make: Sail,Tata, Jsw, Essar, Vizag Steel Or Approved Equivalent Make Conforming To Is Code) , Supply And Erecting High Tensile Ms Foundation Bolts Of Specified Dia. And Length Including Check Nuts, Washers Etc. In Foundations, Columns Etc. Including 1 Coat Of Bituminous Primer, Greasing Exposed Metal Surfaces, Threading, Covering Bolts And Packing The Sleeves With Jute Cloth Etc. As Directed. , S/I/T/C Of Flp Hooters And Red Alarm Light On Octa Pole With Separate Control Cable Input - 240 V Ac Input , S/L Cab 36Cx1.5Mm2cables :Supplying, Laying; Testing And Commissioning Of 1.1 Kv Grade Cables ; Pvc/Xlpeinsulated; Pvc Sheathed; Frls Armoured Copper Conductor Cables Of Following Sizes As Per Is:1554 (Part-I), Is 7098 Part I & Is 1225-Latest Version And Sealed Properly With Pvc Caps In Built-Up Ready Made Trenches; Overhead Cable Trays;Pull Through Pipes Or Exposed On Wall .Beam/Rakes; Trusses Tie/Beamor Embedded In Floor Or Buried Directly Underground (Excavation, Sand And Bricks Shall Be Paid Under Seperate Item Of Boq) Or Through G. I.Pipe.Unit Rates Quoted For Installationof Cables Shall Be Same Irrespective Of Route And Method Of Laying. The Rates Shall Include Laying, Pulling Of Cables, Proper Dressing Of Cables On Cable Trays, Racks, Vertical Raceways And Supply And Installation Of Saddles, Spacers And Nylon Chord For Tying As Required,Identification Tags At Strategic Points/ Every 50 Meter Intervales,Aluminium Cl S. Etc. Cable Identification Tags At Strategic Points/ Every 50 Meter Interval For Identification Of Cable; Etc. Complete.The Straight Through Joints/ Tying With Armour In The Cables Should Be Avoided.Procedure For Laying Of Lt Cables.Makes/Specifications , S/L Cab 4Cx1.5Mm2cables :Supplying, Laying; Testing And Commissioning Of 1.1 Kv Grade Cables ; Pvc/Xlpeinsulated; Pvc Sheathed; Frls Armoured Copper Conductor Cables Of Following Sizes As Per Is:1554 (Part-I), Is 7098 Part I & Is 1225-Latest Version And Sealed Properly With Pvc Caps In Built-Up Ready Made Trenches; Overhead Cable Trays;Pull Through Pipes Or Exposed On Wall .Beam/Rakes; Trusses Tie/Beamor Embedded In Floor Or Buried Directly Underground (Excavation, Sand And Bricks Shall Be Paid Under Seperate Item Of Boq) Or Through G. I.Pipe.Unit Rates Quoted For Installationof Cables Shall Be Same Irrespective Of Route And Method Of Laying. The Rates Shall Include Laying, Pulling Of Cables, Proper Dressing Of Cables On Cable Trays, Racks, Vertical Raceways And Supply And Installation Of Saddles, Spacers And Nylon Chord For Tying As Required,Identification Tags At Strategic Points/ Every 50 Meter Intervales,Aluminium Cl S. Etc. Cable Identification Tags At Strategic Points/ Every 50 Meter Interval For Identification Of Cable; Etc. Complete.The Straight Through Joints/ Tying With Armour In The Cables Should Be Avoided.Procedure For Laying Of Lt Cables.Makes/Specifications , Ex-D Gas Group Iia, Iib Start Stop Push Button Station - Field Control Of Visual Alarm On Octapole , Flp Junction Box 14Supply And Installation Of Ex-D Gas Group Iia, Iib Flp And Wp Junction Box: 340 Dia Multiway Junction Box With Maximum 18 Entries Upto 1 Et With Maximum Entry Three On Three Sides (Top Entry Not To Be Given). , Integration With Control Room Plc. This Includes Supply And Installation Of All Contractors, Relays, Cables, Visual And Audio Indicators Etc Required For Creating Logic Control Wiring Inside Honeywell Automation Plc

BOQ

Sl. No. Item TitleItem Description
1S/L CAB 12PX1.5MM2Cables :Supplying, Laying; Testing and Commissioning Of 1.1 Kv Grade Cables ;PVC Insulated (Fire Retardant Low Smoke) ; Pvc Sheathed; Armoured copper Conductor Cables of Following Sizes As Per Is:1554 (Part-I), and Sealed properly with Pvc Caps In Built-Up Ready Made Trenches; Overhead Cable trays;Pull through Pipes Or Exposed On Wall .Beam/Rakes; Trusses Tie/Beamor Embedded In Floor Or buried Directly Underground (Excavation, sand and bricks shall be paid under seperate item of BOQ) Or Through G. I.Pipe.Unit Rates Quoted For Installationof Cables Shall Be Same Irrespective Of Route and Method Of Laying. The rates Shall Include Laying, Pulling Of Cables, Proper Dressing Of Cables on Cable Trays, Racks, Vertical Raceways and Supply and Installation Of saddles, Spacers and Nylon Chord For Tying As Required,Identification Tags At Strategic Points/ Every 50 Meter Intervales,aluminium Clamps. etc. Cable Identification Tags At Strategic Points/ Every 50 Meter Interval For Identification Of Cable; Etc. Complete.The Straight Through Joints/ tying with armour In The Cables Should Be avoided.Procedure for laying of LT cables.MAKES/SPECIFICATIONSS/L CAB 12PX1.5MM2Cables :Supplying, Laying; Testing and Commissioning Of 1.1 Kv Grade Cables ;PVC Insulated (Fire Retardant Low Smoke) ; Pvc Sheathed; Armoured copper Conductor Cables of Following Sizes As Per Is:1554 (Part-I), and Sealed properly with Pvc Caps In Built-Up Ready Made Trenches; Overhead Cable trays;Pull through Pipes Or Exposed On Wall .Beam/Rakes; Trusses Tie/Beamor Embedded In Floor Or buried Directly Underground (Excavation, sand and bricks shall be paid under seperate item of BOQ) Or Through G. I.Pipe.Unit Rates Quoted For Installationof Cables Shall Be Same Irrespective Of Route and Method Of Laying. The rates Shall Include Laying, Pulling Of Cables, Proper Dressing Of Cables on Cable Trays, Racks, Vertical Raceways and Supply and Installation Of saddles, Spacers and Nylon Chord For Tying As Required,Identification Tags At Strategic Points/ Every 50 Meter Intervales,aluminium Clamps. etc. Cable Identification Tags At Strategic Points/ Every 50 Meter Interval For Identification Of Cable; Etc. Complete.The Straight Through Joints/ tying with armour In The Cables Should Be avoided.Procedure for laying of LT cables.MAKES/SPECIFICATIONS
2S/L CAB 2PX1.5MM2Cables :Supplying, Laying; Testing and Commissioning Of 1.1 Kv Grade Cables ;PVC Insulated (Fire Retardant Low Smoke) ; Pvc Sheathed; Armoured copper Conductor Cables of Following Sizes As Per Is:1554 (Part-I), and Sealed properly with Pvc Caps In Built-Up Ready Made Trenches; Overhead Cable trays;Pull through Pipes Or Exposed On Wall .Beam/Rakes; Trusses Tie/Beamor Embedded In Floor Or buried Directly Underground (Excavation, sand and bricks shall be paid under seperate item of BOQ) Or Through G. I.Pipe.Unit Rates Quoted For Installationof Cables Shall Be Same Irrespective Of Route and Method Of Laying. The rates Shall Include Laying, Pulling Of Cables, Proper Dressing Of Cables on Cable Trays, Racks, Vertical Raceways and Supply and Installation Of saddles, Spacers and Nylon Chord For Tying As Required,Identification Tags At Strategic Points/ Every 50 Meter Intervales,aluminium Clamps. etc. Cable Identification Tags At Strategic Points/ Every 50 Meter Interval For Identification Of Cable; Etc. Complete.The Straight Through Joints/ tying with armour In The Cables Should Be avoided.Procedure for laying of LT cables.MAKES/SPECIFICATIONSS/L CAB 2PX1.5MM2Cables :Supplying, Laying; Testing and Commissioning Of 1.1 Kv Grade Cables ;PVC Insulated (Fire Retardant Low Smoke) ; Pvc Sheathed; Armoured copper Conductor Cables of Following Sizes As Per Is:1554 (Part-I), and Sealed properly with Pvc Caps In Built-Up Ready Made Trenches; Overhead Cable trays;Pull through Pipes Or Exposed On Wall .Beam/Rakes; Trusses Tie/Beamor Embedded In Floor Or buried Directly Underground (Excavation, sand and bricks shall be paid under seperate item of BOQ) Or Through G. I.Pipe.Unit Rates Quoted For Installationof Cables Shall Be Same Irrespective Of Route and Method Of Laying. The rates Shall Include Laying, Pulling Of Cables, Proper Dressing Of Cables on Cable Trays, Racks, Vertical Raceways and Supply and Installation Of saddles, Spacers and Nylon Chord For Tying As Required,Identification Tags At Strategic Points/ Every 50 Meter Intervales,aluminium Clamps. etc. Cable Identification Tags At Strategic Points/ Every 50 Meter Interval For Identification Of Cable; Etc. Complete.The Straight Through Joints/ tying with armour In The Cables Should Be avoided.Procedure for laying of LT cables.MAKES/SPECIFICATIONS
3DYKE DRAIN SIL CERTIFIED PROXIMITY SWITCHDYKE DRAIN SIL CERTIFIED PROXIMITY SWITCH
412\\" CS#150 GATE VALVE12\\" CS#150 GATE VALVE
5S/I 9M DA OCTA POLESupply, installation, testing and commissioning of the following types of GI Octagonal Poles for street lights with the sizes of the poles given below including provision of holes for cable entry, earthing points on poles, base template, grouting bolts all civil works like excavation, PCC, supply and fixing of cable protection pipes disposing of surplus earth, providing shoring, shuttering and dewatering, if required and including supply of cement, steel, pipes, base plates, paint and all sundry materials including all materials and labour. Street light fittind would be measured and paid under seperate item of BOQ. Civil Work to be paid seperately.S/I 9M DA OCTA POLESupply, installation, testing and commissioning of the following types of GI Octagonal Poles for street lights with the sizes of the poles given below including provision of holes for cable entry, earthing points on poles, base template, grouting bolts all civil works like excavation, PCC, supply and fixing of cable protection pipes disposing of surplus earth, providing shoring, shuttering and dewatering, if required and including supply of cement, steel, pipes, base plates, paint and all sundry materials including all materials and labour. Street light fittind would be measured and paid under seperate item of BOQ. Civil Work to be paid seperately.
6EXCV<1.5 ORD DIS IN Earth work in excavation upto required depth below existing ground level upto required depth including removal of vegetation,shrubs and debris cutting and dressing the sides in slopes and bottom, levelling, grading and ramming of bottoms, bailing out of water , supplying of Temporary supports to existing services line like water pipes,sewage pipes,electric overhead and u/g cables etc all if encountered, shoring, strutting and disposal of excavated earth anywhere inside BPCL's premises as directed by the Engineer in Charge, complete. Payment shall be made as per the actual measurement but not more than excavation plan.Also no payment would be made for extra excavation for making slopes etc.The excavated earth to be spread in loose 150 mm thick layers, watered, rolled andwell consolidated using suitable compactors.The density to be achieved shall not be less than 90% of the density obtained in the laboratory (modified proctor method) (Payment against this item shall be released only for the earth being disposed inside BPCL premises)EXCV<1.5 ORD DIS IN Earth work in excavation upto required depth below existing ground level upto required depth including removal of vegetation,shrubs and debris cutting and dressing the sides in slopes and bottom, levelling, grading and ramming of bottoms, bailing out of water , supplying of Temporary supports to existing services line like water pipes,sewage pipes,electric overhead and u/g cables etc all if encountered, shoring, strutting and disposal of excavated earth anywhere inside BPCL's premises as directed by the Engineer in Charge, complete. Payment shall be made as per the actual measurement but not more than excavation plan.Also no payment would be made for extra excavation for making slopes etc.The excavated earth to be spread in loose 150 mm thick layers, watered, rolled andwell consolidated using suitable compactors.The density to be achieved shall not be less than 90% of the density obtained in the laboratory (modified proctor method) (Payment against this item shall be released only for the earth being disposed inside BPCL premises)
7RCC PLIN 1:1.5:3 CSSupplying and laying in postion RCC of specified nominal mix using 20mm anddown size graded crushed stone aggregate in sub structure of all types e.g. trenches, culverts, manholes, pipe encasement, catchpits, drains, pits, etc.,including placing of concrete,supplying pockets,openings, recesses,chamfering wherever required etc., vibrating, tamping, curing andrendering if reqd. to give a smooth and even surface etc. all complete(excluding the cost of reinforcement, but including the cost of centringand shuttering)for all depths below and upto plinth level in any shape,position, thickness etc. all complete as specified and directed. Onlysteel shuttering will be used so as to obtain required finish. Theheight of shuttering shall not exceed 1.5 m per lift of concrete.: 1:1.5:3 (1 cement: 1.5 coarse sand: 3 grade stone aggregate 20 mm nominal size)RCC PLIN 1:1.5:3 CSSupplying and laying in postion RCC of specified nominal mix using 20mm anddown size graded crushed stone aggregate in sub structure of all types e.g. trenches, culverts, manholes, pipe encasement, catchpits, drains, pits, etc.,including placing of concrete,supplying pockets,openings, recesses,chamfering wherever required etc., vibrating, tamping, curing andrendering if reqd. to give a smooth and even surface etc. all complete(excluding the cost of reinforcement, but including the cost of centringand shuttering)for all depths below and upto plinth level in any shape,position, thickness etc. all complete as specified and directed. Onlysteel shuttering will be used so as to obtain required finish. Theheight of shuttering shall not exceed 1.5 m per lift of concrete.: 1:1.5:3 (1 cement: 1.5 coarse sand: 3 grade stone aggregate 20 mm nominal size)
8Supplying and placing HYSD steel reinforcement of Grade 500 (TMT) conforming to IS 1786 in position for RCC worksincluding straightening, cutting, bending, placing in position andbinding with 16 SWG black soft annealed binding wire at everyintersection, supplying and placing appropriate cover block all completeincluding cleaning and making it free from oil, grease etc. complete-for all heights and depths and conforming to relevant IS code (Make: SAIL,TATA, JSW, ESSAR, VIZAG STEEL or approved equivalent make conforming to IS code)Supplying and placing HYSD steel reinforcement of Grade 500 (TMT) conforming to IS 1786 in position for RCC worksincluding straightening, cutting, bending, placing in position andbinding with 16 SWG black soft annealed binding wire at everyintersection, supplying and placing appropriate cover block all completeincluding cleaning and making it free from oil, grease etc. complete-for all heights and depths and conforming to relevant IS code (Make: SAIL,TATA, JSW, ESSAR, VIZAG STEEL or approved equivalent make conforming to IS code)
9Supply and erecting High Tensile MS Foundation bolts of specified dia. and length including check nuts, washers etc. in foundations, columns etc. including 1 coat of bituminous primer, greasing exposed metal surfaces, threading, covering bolts and packing the sleeves with jute cloth etc. as directed.Supply and erecting High Tensile MS Foundation bolts of specified dia. and length including check nuts, washers etc. in foundations, columns etc. including 1 coat of bituminous primer, greasing exposed metal surfaces, threading, covering bolts and packing the sleeves with jute cloth etc. as directed.
10S/I/T/C of FLP hooters and red alarm light on octa pole with separate control cable input - 240 V AC inputS/I/T/C of FLP hooters and red alarm light on octa pole with separate control cable input - 240 V AC input
11S/L CAB 36CX1.5MM2Cables :Supplying, Laying; Testing and Commissioning Of 1.1 Kv Grade Cables ; Pvc/XLPEinsulated; Pvc Sheathed; FRLS Armoured copper Conductor Cables of Following Sizes As Per Is:1554 (Part-I), IS 7098 Part I & IS 1225-Latest Version and Sealed properly with Pvc Caps In Built-Up Ready Made Trenches; Overhead Cable trays;Pull through Pipes Or Exposed On Wall .Beam/Rakes; Trusses Tie/Beamor Embedded In Floor Or buried Directly Underground (Excavation, sand and bricks shall be paid under seperate item of BOQ) Or Through G. I.Pipe.Unit Rates Quoted For Installationof Cables Shall Be Same Irrespective Of Route and Method Of Laying. The rates Shall Include Laying, Pulling Of Cables, Proper Dressing Of Cables on Cable Trays, Racks, Vertical Raceways and Supply and Installation Of saddles, Spacers and Nylon Chord For Tying As Required,Identification Tags At Strategic Points/ Every 50 Meter Intervales,aluminium Clamps. etc. Cable Identification Tags At Strategic Points/ Every 50 Meter Interval For Identification Of Cable; Etc. Complete.The Straight Through Joints/ tying with armour In The Cables Should Be avoided.Procedure for laying of LT cables.MAKES/SPECIFICATIONSS/L CAB 36CX1.5MM2Cables :Supplying, Laying; Testing and Commissioning Of 1.1 Kv Grade Cables ; Pvc/XLPEinsulated; Pvc Sheathed; FRLS Armoured copper Conductor Cables of Following Sizes As Per Is:1554 (Part-I), IS 7098 Part I & IS 1225-Latest Version and Sealed properly with Pvc Caps In Built-Up Ready Made Trenches; Overhead Cable trays;Pull through Pipes Or Exposed On Wall .Beam/Rakes; Trusses Tie/Beamor Embedded In Floor Or buried Directly Underground (Excavation, sand and bricks shall be paid under seperate item of BOQ) Or Through G. I.Pipe.Unit Rates Quoted For Installationof Cables Shall Be Same Irrespective Of Route and Method Of Laying. The rates Shall Include Laying, Pulling Of Cables, Proper Dressing Of Cables on Cable Trays, Racks, Vertical Raceways and Supply and Installation Of saddles, Spacers and Nylon Chord For Tying As Required,Identification Tags At Strategic Points/ Every 50 Meter Intervales,aluminium Clamps. etc. Cable Identification Tags At Strategic Points/ Every 50 Meter Interval For Identification Of Cable; Etc. Complete.The Straight Through Joints/ tying with armour In The Cables Should Be avoided.Procedure for laying of LT cables.MAKES/SPECIFICATIONS
12S/L CAB 4CX1.5MM2Cables :Supplying, Laying; Testing and Commissioning Of 1.1 Kv Grade Cables ; Pvc/XLPEinsulated; Pvc Sheathed; FRLS Armoured copper Conductor Cables of Following Sizes As Per Is:1554 (Part-I), IS 7098 Part I & IS 1225-Latest Version and Sealed properly with Pvc Caps In Built-Up Ready Made Trenches; Overhead Cable trays;Pull through Pipes Or Exposed On Wall .Beam/Rakes; Trusses Tie/Beamor Embedded In Floor Or buried Directly Underground (Excavation, sand and bricks shall be paid under seperate item of BOQ) Or Through G. I.Pipe.Unit Rates Quoted For Installationof Cables Shall Be Same Irrespective Of Route and Method Of Laying. The rates Shall Include Laying, Pulling Of Cables, Proper Dressing Of Cables on Cable Trays, Racks, Vertical Raceways and Supply and Installation Of saddles, Spacers and Nylon Chord For Tying As Required,Identification Tags At Strategic Points/ Every 50 Meter Intervales,aluminium Clamps. etc. Cable Identification Tags At Strategic Points/ Every 50 Meter Interval For Identification Of Cable; Etc. Complete.The Straight Through Joints/ tying with armour In The Cables Should Be avoided.Procedure for laying of LT cables.MAKES/SPECIFICATIONSS/L CAB 4CX1.5MM2Cables :Supplying, Laying; Testing and Commissioning Of 1.1 Kv Grade Cables ; Pvc/XLPEinsulated; Pvc Sheathed; FRLS Armoured copper Conductor Cables of Following Sizes As Per Is:1554 (Part-I), IS 7098 Part I & IS 1225-Latest Version and Sealed properly with Pvc Caps In Built-Up Ready Made Trenches; Overhead Cable trays;Pull through Pipes Or Exposed On Wall .Beam/Rakes; Trusses Tie/Beamor Embedded In Floor Or buried Directly Underground (Excavation, sand and bricks shall be paid under seperate item of BOQ) Or Through G. I.Pipe.Unit Rates Quoted For Installationof Cables Shall Be Same Irrespective Of Route and Method Of Laying. The rates Shall Include Laying, Pulling Of Cables, Proper Dressing Of Cables on Cable Trays, Racks, Vertical Raceways and Supply and Installation Of saddles, Spacers and Nylon Chord For Tying As Required,Identification Tags At Strategic Points/ Every 50 Meter Intervales,aluminium Clamps. etc. Cable Identification Tags At Strategic Points/ Every 50 Meter Interval For Identification Of Cable; Etc. Complete.The Straight Through Joints/ tying with armour In The Cables Should Be avoided.Procedure for laying of LT cables.MAKES/SPECIFICATIONS
13Ex-d Gas Group IIA, IIB Start Stop Push Button station - FIELD CONTROL OF VISUAL ALARM ON OCTAPOLEEx-d Gas Group IIA, IIB Start Stop Push Button station - FIELD CONTROL OF VISUAL ALARM ON OCTAPOLE
14FLP JUNCTION BOX 14\\"Supply and installation of Ex-D Gas Group IIA, IIB FLP and WP Junction box: 340 dia multiway Junction box with maximum 18 entries upto 1\\" ET with maximum entry three on three sides (top entry not to be given).FLP JUNCTION BOX 14\\"Supply and installation of Ex-D Gas Group IIA, IIB FLP and WP Junction box: 340 dia multiway Junction box with maximum 18 entries upto 1\\" ET with maximum entry three on three sides (top entry not to be given).
15Integration with control room PLC. This includes supply and installation of all contractors, relays, cables, visual and audio indicators etc required for creating logic control wiring inside Honeywell Automation PLCIntegration with control room PLC. This includes supply and installation of all contractors, relays, cables, visual and audio indicators etc required for creating logic control wiring inside Honeywell Automation PLC

AI Tender Summary

OUR REF NO 57851089
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 38.15 Lakhs
LAST DATE 24-10-2026
Authority
Authority Name Bharat Petroleum Corporation Limited
Work Description Bids Are invited for Custom Bid For Services - Kandla- Dyke Drain Valve And Instrumentation Works - S/L Cab 12Px1.5Mm2cables :Supplying, Laying; Testing And Commissioning Of 1.1 Kv Grade Cables ;Pvc Insulated (Fire Retardant Low Smoke) ; Pvc Sheathed; Armoured Copper Conductor Cables Of Following Sizes As Per Is:1554 (Part-I), And Sealed Properly With Pvc Caps In Built-Up Ready Made Trenches; Overhead Cable Trays;Pull Through Pipes Or Exposed On Wall .Beam/Rakes; Trusses Tie/Beamor Embedded In Floor Or Buried Directly Underground (Excavation, Sand And Bricks Shall Be Paid Under Seperate Item Of Boq) Or Through G. I.Pipe.Unit Rates Quoted For Installationof Cables Shall Be Same Irrespective Of Route And Method Of Laying. The Rates Shall Include Laying, Pulling Of Cables, Proper Dressing Of Cables On Cable Trays, Racks, Vertical Raceways And Supply And Installation Of Saddles, Spacers And Nylon Chord For Tying As Required,Identification Tags At Strategic Points/ Every 50 Meter Intervales,Aluminium Cl S. Etc. Cable Identification Tags At Strategic Points/ Every 50 Meter Interval For Identification Of Cable; Etc. Complete.The Straight Through Joints/ Tying With Armour In The Cables Should Be Avoided.Procedure For Laying Of Lt Cables.Makes/Specifications , S/L Cab 2Px1.5Mm2cables :Supplying, Laying; Testing And Commissioning Of 1.1 Kv Grade Cables ;Pvc Insulated (Fire Retardant Low Smoke) ; Pvc Sheathed; Armoured Copper Conductor Cables Of Following Sizes As Per Is:1554 (Part-I), And Sealed Properly With Pvc Caps In Built-Up Ready Made Trenches; Overhead Cable Trays;Pull Through Pipes Or Exposed On Wall .Beam/Rakes; Trusses Tie/Beamor Embedded In Floor Or Buried Directly Underground (Excavation, Sand And Bricks Shall Be Paid Under Seperate Item Of Boq) Or Through G. I.Pipe.Unit Rates Quoted For Installationof Cables Shall Be Same Irrespective Of Route And Method Of Laying. The Rates Shall Include Laying, Pulling Of Cables, Proper Dressing Of Cables On Cable Trays, Racks, Vertical Raceways And Supply And Installation Of Saddles, Spacers And Nylon Chord For Tying As Required,Identification Tags At Strategic Points/ Every 50 Meter Intervales,Aluminium Cl S. Etc. Cable Identification Tags At Strategic Points/ Every 50 Meter Interval For Identification Of Cable; Etc. Complete.The Straight Through Joints/ Tying With Armour In The Cables Should Be Avoided.Procedure For Laying Of Lt Cables.Makes/Specifications , Dyke Drain Sil Certified Proximity Switch , 12 Cs#150 Gate Valve , S/I 9M Da Octa Polesupply, Installation, Testing And Commissioning Of The Following Types Of Gi Octagonal Poles For Street Lights With The Sizes Of The Poles Given Below Including Provision Of Holes For Cable Entry, Earthing Points On Poles, Base Template, Grouting Bolts All Civil Works Like Excavation, Pcc, Supply And Fixing Of Cable Protection Pipes Disposing Of Surplus Earth, Providing Shoring, Shuttering And Dewatering, If Required And Including Supply Of Cement, Steel, Pipes, Base Plates, Paint And All Sundry Materials Including All Materials And Labour. Street Light Fittind Would Be Measured And Paid Under Seperate Item Of Boq. Civil Work To Be Paid Seperately. , Excv<1.5 Ord Dis In Earth Work In Excavation Upto Required Depth Below Existing Ground Level Upto Required Depth Including Removal Of Vegetation,Shrubs And Debris Cutting And Dressing The Sides In Slopes And Bottom, Levelling, Grading And Ramming Of Bottoms, Bailing Out Of Water , Supplying Of Temporary Supports To Existing Services Line Like Water Pipes,Sewage Pipes,Electric Overhead And U/G Cables Etc All If Encountered, Shoring, Strutting And Disposal Of Excavated Earth Anywhere Inside Bpcls Premises As Directed By The Engineer In Charge, Complete. Payment Shall Be Made As Per The Actual Measurement But Not More Than Excavation Plan.Also No Payment Would Be Made For Extra Excavation For Making Slopes Etc.The Excavated Earth To Be Spread In Loose 150 Mm Thick Layers, Watered, Rolled Andwell Consolidated Using Suitable Compactors.The Density To Be Achieved Shall Not Be Less Than 90% Of The Density Obtained In The Laboratory (Modified Proctor Method) (Payment Against This Item Shall Be Released Only For The Earth Being Disposed Inside Bpcl Premises) , Rcc Plin 1:1.5:3 Cssupplying And Laying In Postion Rcc Of Specified Nominal Mix Using 20Mm Anddown Size Graded Crushed Stone Aggregate In Sub Structure Of All Types E.G. Trenches, Culverts, Manholes, Pipe Encasement, Catchpits, Drains, Pits, Etc.,Including Placing Of Concrete,Supplying Pockets,Openings, Recesses,Chamfering Wherever Required Etc., Vibrating, T Ing, Curing Andrendering If Reqd. To Give A Smooth And Even Surface Etc. All Complete(Excluding The Cost Of Reinforcement, But Including The Cost Of Centringand Shuttering)For All Depths Below And Upto Plinth Level In Any Shape,Position, Thickness Etc. All Complete As Specified And Directed. Onlysteel Shuttering Will Be Used So As To Obtain Required Finish. Theheight Of Shuttering Shall Not Exceed 1.5 M Per Lift Of Concrete.: 1:1.5:3 (1 Cement: 1.5 Coarse Sand: 3 Grade Stone Aggregate 20 Mm Nominal Size) , Supplying And Placing Hysd Steel Reinforcement Of Grade 500 (Tmt) Conforming To Is 1786 In Position For Rcc Worksincluding Straightening, Cutting, Bending, Placing In Position Andbinding With 16 Swg Black Soft Annealed Binding Wire At Everyintersection, Supplying And Placing Appropriate Cover Block All Completeincluding Cleaning And Making It Free From Oil, Grease Etc. Complete-For All Heights And Depths And Conforming To Relevant Is Code (Make: Sail,Tata, Jsw, Essar, Vizag Steel Or Approved Equivalent Make Conforming To Is Code) , Supply And Erecting High Tensile Ms Foundation Bolts Of Specified Dia. And Length Including Check Nuts, Washers Etc. In Foundations, Columns Etc. Including 1 Coat Of Bituminous Primer, Greasing Exposed Metal Surfaces, Threading, Covering Bolts And Packing The Sleeves With Jute Cloth Etc. As Directed. , S/I/T/C Of Flp Hooters And Red Alarm Light On Octa Pole With Separate Control Cable Input - 240 V Ac Input , S/L Cab 36Cx1.5Mm2cables :Supplying, Laying; Testing And Commissioning Of 1.1 Kv Grade Cables ; Pvc/Xlpeinsulated; Pvc Sheathed; Frls Armoured Copper Conductor Cables Of Following Sizes As Per Is:1554 (Part-I), Is 7098 Part I & Is 1225-Latest Version And Sealed Properly With Pvc Caps In Built-Up Ready Made Trenches; Overhead Cable Trays;Pull Through Pipes Or Exposed On Wall .Beam/Rakes; Trusses Tie/Beamor Embedded In Floor Or Buried Directly Underground (Excavation, Sand And Bricks Shall Be Paid Under Seperate Item Of Boq) Or Through G. I.Pipe.Unit Rates Quoted For Installationof Cables Shall Be Same Irrespective Of Route And Method Of Laying. The Rates Shall Include Laying, Pulling Of Cables, Proper Dressing Of Cables On Cable Trays, Racks, Vertical Raceways And Supply And Installation Of Saddles, Spacers And Nylon Chord For Tying As Required,Identification Tags At Strategic Points/ Every 50 Meter Intervales,Aluminium Cl S. Etc. Cable Identification Tags At Strategic Points/ Every 50 Meter Interval For Identification Of Cable; Etc. Complete.The Straight Through Joints/ Tying With Armour In The Cables Should Be Avoided.Procedure For Laying Of Lt Cables.Makes/Specifications , S/L Cab 4Cx1.5Mm2cables :Supplying, Laying; Testing And Commissioning Of 1.1 Kv Grade Cables ; Pvc/Xlpeinsulated; Pvc Sheathed; Frls Armoured Copper Conductor Cables Of Following Sizes As Per Is:1554 (Part-I), Is 7098 Part I & Is 1225-Latest Version And Sealed Properly With Pvc Caps In Built-Up Ready Made Trenches; Overhead Cable Trays;Pull Through Pipes Or Exposed On Wall .Beam/Rakes; Trusses Tie/Beamor Embedded In Floor Or Buried Directly Underground (Excavation, Sand And Bricks Shall Be Paid Under Seperate Item Of Boq) Or Through G. I.Pipe.Unit Rates Quoted For Installationof Cables Shall Be Same Irrespective Of Route And Method Of Laying. The Rates Shall Include Laying, Pulling Of Cables, Proper Dressing Of Cables On Cable Trays, Racks, Vertical Raceways And Supply And Installation Of Saddles, Spacers And Nylon Chord For Tying As Required,Identification Tags At Strategic Points/ Every 50 Meter Intervales,Aluminium Cl S. Etc. Cable Identification Tags At Strategic Points/ Every 50 Meter Interval For Identification Of Cable; Etc. Complete.The Straight Through Joints/ Tying With Armour In The Cables Should Be Avoided.Procedure For Laying Of Lt Cables.Makes/Specifications , Ex-D Gas Group Iia, Iib Start Stop Push Button Station - Field Control Of Visual Alarm On Octapole , Flp Junction Box 14Supply And Installation Of Ex-D Gas Group Iia, Iib Flp And Wp Junction Box: 340 Dia Multiway Junction Box With Maximum 18 Entries Upto 1 Et With Maximum Entry Three On Three Sides (Top Entry Not To Be Given). , Integration With Control Room Plc. This Includes Supply And Installation Of All Contractors, Relays, Cables, Visual And Audio Indicators Etc Required For Creating Logic Control Wiring Inside Honeywell Automation Plc
Basic Detail
Tender No GEM/2026/B/8112246
Bidding Type Tender
Location
City Kachchh
State Gujarat
Key Dates
Publish Date 03 Oct 2026
Submission Date 24 Oct 2026
Open Date 25 Oct 2026
Finance
Tender Value 38.15 Lakhs
Tender Fee Ref. Documents
EMD 30000
Exemption Available
Document List
72815ff3-c04a-4dac-b134-62d94d347f10.pdf
1791007040.xlsx
1791007146.pdf
1791007158.pdf
1791007166.pdf
1791007178.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Oct 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
pdf

72815ff3-c04a-4dac-b134-62d94d347f10.pdf

xlsx

1791007040.xlsx

pdf

1791007146.pdf

pdf

1791007158.pdf

pdf

1791007166.pdf

pdf

1791007178.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender