Defence Statutory Bodies & Commissions/Committees Closing in 3 days TDR #57850407

Tender For Day To Day Preventive Maintenance And Repair Internal Electric Supply, Switch Board, Switches, Mcb, Mcb Dbs, Led Tube Lights, Post Top Lantern, Gate Lights, Frp Boxes, Electric Geysers, Air Circulators, Ceiling Fans And Exhaust Fans And In

Issued by Statutory Bodies & Commissions/Committees · Mumbai Suburban, Maharashtra
Tender Value
40 Lakhs
Estimated cost
Bid Submission
31 Oct 2026
3 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai Suburban → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Day To Day Preventive Maintenance And Repair Internal Electric Supply, Switch Board, Switches, Mcb, Mcb Dbs, Led Tube Lights, Post Top Lantern, Gate Lights, Frp Boxes, Electric Geysers, Air Circulators, Ceiling Fans And Exhaust Fans And Internal Point Wiring Of High Rise Building And Otm Accn At Nchc Powai Under Ge (Nw) Bhandup

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 24-Oct-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 31-Oct-2026

BOQ

Name of Work:- DAY TO DAY PREVENTIVE MAINTENANCE AND REPAIR INTERNAL ELECTRIC SUPPLY, SWITCH BOARD, SWITCHES, MCB, MCB DBs, LED TUBE LIGHTS, POST TOP LANTERN, GATE LIGHTS, FRP BOXES, ELECTRIC GEYSERS, AIR CIRCULATORS, CEILING FANS AND EXHAUST FANS AND INTERNAL POINT WIRING OF HIGH RISE BUILDING AND OTM ACCN AT NCHC POWAI UNDER GE (NW) BHANDUP
Sl. No. Item Description
1Taking down carefully unserviceable copper / aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
2Taking down carefully by unscrewing from boards / outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (to be measured only when found serviceable in all respects complete for reuse).
3Material and Labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit with all fittings, accessories, PVC junction boxes etc. with and including concealed GI metal boxes 1.2 mm thick,(18 Guage) 50mm deep, with earth dolly, covered with modular white cover plate & frame of suitable module for mounting switches, sockets, regulators etc and also including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed for one light point / exhaust fan point controlled by one, one way switch 6 Amps complete all as specified and directed.
4All as per item No 3 above but one 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on same board complete all as specified and directed.
5All as per item No 3 above but one 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on independent board complete all as specified and directed.
6All as per item No 3 above but one two way light point controlled by two nos, two way 6A switches complete all as specified and as directed.
7All as per item No 3 above but one bell point controlled by one, one way switch 6 Amps complete all as specified and as directed
8All as per item No 3 above but one ceiling fan point & regulator controlled by one, one way switch 6 Amps complete all as specified and as directed.
9All as per item no. 3 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for one 6 pin socket outlet plug point, 6 Amps independent including necessary running of 2.5 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly complete all as specified and as directed.
10All as per item no. 3 here-in before but using 4.0 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for 6/16 Amps power point including necessary running of 4.0 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly complete all as specified and as directed.
11Material and Labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty, PVC casing caping with all fittings, accessories, PVC junction boxes etc fixed to walls/ceilings with and including concealed GI metal boxes 1.2 mm thick,(18 Guage) 50 mm deep, with earth dolly, covered with modular white cover plate & frame suitable for mounting switches, sockets, regulators etc and also including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed for one light point / exhaust fan point controlled by one, one way switch 6 Amps complete all as specified and as directed.
12All as per item no. 11 here-in before but one 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on same board complete all as specified and directed.
13All as per item no. 11 here-in before but one 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on independent board complete all as specified and directed.
14All as per item no. 11 here-in before but one two way light point controlled by two nos, two way 6A switches complete all as specified and directed.
15All as per item no. 11 here-in before but one bell point controlled by one, one way switch 6 Amps complete all as specified and directed.
16All as per item no. 11 here-in before but one ceiling fan point & regulator controlled by one, one way switch 6 Amps complete all as specified and directed.
17All as per item no. 11 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for one 6 pin socket outlet plug point, 6 Amps independent including necessary running of 2.5 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly complete all as specified and directed.
18All as per item no. 11 here-in before but using 4.0 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for 6 / 16 Amps power point including necessary running of 4.0 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly complete all as specified and as directed Note for Item Ser No 3 to 18: (i) Cutting chases for conduits and sinking's for GI metal switch boxes and making good to walls in cement mortar (1:3) to match with existing surfaces shall be carried out by the contractor without any extra cost from the department.(ii) Partially partly wiring in casing caping with all fittings accessories PVC junction boxes wherever concealed wiring is not possible on the surfaces of RCC slab / ceiling /columns / beams etc shall deemed to be included in the unit rate quoted against item.
19Supply and fixing Modular switch, one way 6 A, one module, 230 volts complete all as specified and directed.
20Supply and fixing Modular Bell push 6A, one module 230 volts complete all as specified and directed.
21Supply and fixing Modular switch, one way 16 A, one module, 230 volts complete all as specified and directed.
22Supply and fixing Modular socket outlet multipurpose, 6A - 3 pin combined 2 module, 230 volts complete all as specified and directed.
23Supply and fixing Modular socket outlet multipurpose, 6A/16A - 2/3 pin combined 2 module, 230 volts complete all as specified and directed.
24Supply and fixing modular stepped type electronic fan regulator flush type, 120W - 2 module suitable for 230V 50Hz AC supply complete all as specified and directed.
25Supply and fixing modular stepped type electronic fan regulator flush type BLDC Fan compatible, 120W - 1 module suitable for 230V 50Hz AC supply complete all as specified and directed.
26Supply and fixing switch piano, flush type, polycarbonate, single pole, one way 6 Amp complete all as specified and directed.
27Supply and fixing Bell push, flush type, polycarbonate, 6 amp complete all as specified and directed.
28Supply and fixing switch piano, polycarbonate, flush type single pole, one way 16 Amp complete all as specified and directed.
29Supply and fixing socket outlet, 2-in-1, 6 pin, 6 and 16 Amps, flush type complete all as specified and directed.
30Supply and fixing Socket outlet 2 in 1, 5 pin, 6A complete all as specified and directed.
31M & L for switch socket combination 2 in 1, 6 pin, 6 A flush type complete all as specified and directed.
32M & L for switch socket combination 6A / 16A, 6 in 1 flush type complete all as specified and directed.
33Supply and fixing stepped type electronic fan regulator flush type, for BLDC fan 120W - 2 module suitable for 230V 50Hz AC supply complete all as specified and directed.
34Supply and fixing electric Buzzer, Ding Dong bell suitable for operation on AC, 230 volts, single pole complete all as specified and directed.
35M & L for ceiling rose, 3 terminal / PVC / polycarbonate, isolated body complete all as specified and directed.
36M & L for fancy lamp holder, PVC / Polycarbonate type with back plate of brass terminal suitable for batten fittings complete all as specified and directed.
37Supply and fixing 6 Amps Top Plug with indicator complete all as specified and directed.
38Supply and fixing 16 Amps Top Plug with indicator complete all as specified and directed.
39Supply and fixing in repairs modular white cover plate with frame, to true size of the existing concealed metal box & make as per site requirement of 3 Module complete all as specified and directed.
40All as per item no. 40 here-in before but 4 Module
41All as per item no. 40 here-in before but 6 Module
42All as per item no. 40 here-in before but 8 Module
43All as per item no. 40 here-in before but 12/16 Module
44Supply and fixing in repairs GI metal flush boxes 1.2 mm thick, (18 Guage) 50 mm deep, with earth dolly, suitable for mounting modular white cover plate of size 03 Module complete all as specified and directed.
45All as per item no. 44 here-in before but 4 Module
46All as per item no. 44 here-in before but 6 Module
47All as per item no. 44 here-in before but 8 Module
48All as per item no. 44 here-in before but 12/16 Module
49Supply and fixing in repairs plastic surface box, with earth dolly, suitable for mounting modular white cover plate of size 3 Module complete all as specified and directed.
50All as per item no. 49 here-in before but 4 Module
51All as per item no. 49 here-in before but 6 Module
52All as per item no. 49 here-in before but 8 Module
53All as per item no. 49 here-in before but 12/16 Module
54Supply and fixing 3 mm thick white (Hylam) sheet for electrical application to incorporate switches, sockets etc including cutting, drilling, shaping of material to site requirement and fixing with brass cadmium screws of adequate size and length complete all as specified and directed. Note for Item Ser No 20 to 54 : (i) Item will also be exercised in repairs means labour component involved in taking out existing unserviceable from its place and fixing new in position is deemed to be included in the unit rate quoted. (ii) Making good disturbed wall in cement mortar (1:3) & with wall putty for concealing metal box and painting wall surface as per existing finish shall be carried out by the contractor without any extra cost from the department.
55S & F in repairs LED indoor decorative aluminum housing LED batten integrated type tube light fitting, suitable and including wattage 20 / 22W, rated input voltage 140V AC – 270V AC, driver efficiency 88%, Lumens efficiency 100 lm/W, starting voltage 90V, THD<=20, color rendering index (CRI).80, color temperature 6500K, no harmful radiations, inbuilt surge protection 2.5 kv, isolation 3.75kv, Zero mercury content, complete with all accessories internally pre wired and including connected up with twin core twisted flexible copper conductor cable with suitable sizes complete all as specified and directed.
56S & F in repairs LED indoor decorative polycarbonate housing LED batten integrated type tube light fitting, suitable and including wattage 10W, rated input voltage 140V AC – 270V AC, driver efficiency 88%, lumens efficiency 100 lm/W, starting voltage 90V, THD<=20, color rendering index (CRI).80, colour temperature 6500K, no harmful radiations, inbuilt surge protection 2.5 kv, isolation 3.75kv, zero mercury content, complete with all accessories internally pre wired and including connected up with twin core twisted flexible copper conductor cable with suitable sizes complete all as specified and directed.Note for Item Ser No 55 & 56 : (i) Item will also be exercised in repairs means labour component involved in taking out existing unserviceable from its place and fixing new in position is deemed to be included in the unit rate quoted.
57Supply and fixing in repairs amp rating 240V, 10KA 'C' curve, IP 20 protected terminals, miniature circuit breaker (MCB) of SP 6-32 Amp in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
58Supply and fixing in repairs amp rating 240V, 10KA 'C' curve, IP 20 protected terminals, miniature circuit breaker (MCB) of SPN 32 Amp in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
59Supply and fixing in repairs amp rating 240V, 10KA 'C' curve, IP 20 protected terminals, miniature circuit breaker (MCB) of SPN 40-63 Amp in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
60Supply and fixing in repairs 415V 10KA 'C' curve, IP 20 protected terminals, miniature circuit breaker (MCB) of TPN 40-100 Amp capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
61Supply and fixing in repairs 415V 10KA 'C' curve, IP 20 protected terminals, miniature circuit breaker (MCB) of TP 25-63 Amp capacity in the DB complete with connection testing and commissioning.
62S & F sheet metal enclosure MCB SPN 4 way suitable for flush mounting and surface mounting, MCB DB with fully shrouded neutral bars, earthbar and cable ties for cable management, 240 Volts, IP 43 - #IK 09 with metal double door & magnetic locking system including inserting the DBs in wall by cutting the brick / stone masonary etc and making good of disturbed surface to match the existing colour of wall complete all as specified and directed.
63S & F sheet metal enclosure MCB SPN 8 way suitable for flush mounting and surface mounting, MCB DB with fully shrouded neutral bars, earthbar and cable ties for cable management, 240 Volts, IP 43 - #IK 09 with metal double door & magnetic locking system including inserting the DBs in wall by cutting the brick / stone masonary etc and making good of disturbed surface to match the existing colour of wall complete all as specified and directed.
64S & F sheet metal enclosure MCB SPN 12 way suitable for flush mounting and surface mounting, MCB DB with fully shrouded neutral bars, earthbar and cable ties for cable management, 240 Volts, IP 43 - #IK 09 with metal double door & magnetic locking system including inserting the DBs in wall by cutting the brick / stone masonary etc and making good of disturbed surface to match the existing colour of wall complete all as specified and directed.
65S & F sheet metal enclosure TPN 6 way suitable for flush mounting and surface mounting, MCB DB with fully insulated & shrouded neutral bars, earthbar and cable ties for cable management & provision for FP MCB / Isolator / RCCB / RCBO as incomer and SP MCB's as outgoing, 415 Volts, IP 43 - #IK 09 with metal double door & magnetic locking system including inserting the DBs in wall by cutting the brick / stone masonary etc and making good of disturbed surface in cement mortar to match the existing surface & colour to wall complete all as specified and directed.
66Supply and fixing flush mounting and surface mounting single pole and neutral sheet metal enclosure suitable for 240 V with neutral link, two pin, earth plug and socket plug top complete all as specified and as directed with one single pole MCB upto 20 Amps complete all as specified and directed.
67S & F sheet metal enclosure MCCB VTPN 6 way suitable for flush mounting and surface mounting, MCB DB with 250 Amps rated bus bar for each phase, fully insulated & shrouded 2 neutral bars, 2 earthbar and cable ties for cable management & with provision for MCCB as incomer and SP/TP MCB's as outgoing, 415 Volts, IP 43 - #IK 09 with metal double door & magnetic locking system including inserting the DBs in wall by cutting the brick / stone masonary etc and making good of disturbed surface in cement mortar to match the existing surface & colour to wall complete all as specified and as directed.
68S & F sheet metal enclosure MCCB VTPN 4 way suitable for flush mounting and surface mounting, MCB DB with 250 Amps rated bus bar for each phase, fully insulated & shrouded 2 neutral bars, 2 earthbar and cable ties for cable management, & with provision for DPX³ 100 MCCB as incomer and SP / TP MCB's as outgoing, 415 Volts, IP 43 - #IK 09 with metal double door & magnetic locking system including inserting the DBs in wall by cutting the brick / stone masonary etc and making good of disturbed surface in cement mortar to match the existing surface & colour to wall complete all as specified and as directed.
69S & F sheet metal enclosure MCCB VTPN 8 way suitable for flush mounting and surface mounting, MCB DB with 250 Amps rated bus bar for each phase, fully insulated & shrouded 2 neutral bars, 2 earthbar and cable ties for cable management & with provision for MCCB as incomer and SP/TP MCB's as outgoing, 415 Volts, IP 43 - #IK 09 with metal double door & magnetic locking system including inserting the DBs in wall by cutting the brick / stone masonary etc and making good of disturbed surface in cement mortar to match the existing surface & colour to wall complete all as specified and as directed. Note for Item Ser No 67 to 69 : (i) Item will also be exercised in repairs means Labour component involved in taking out existing unserviceable from its place and fixing new in position is deemed to be included in the unit rate quoted.(ii) Making good disturbed wall in cement mortar (1:3) & with wall putty for concealing metal box and painting wall surface as per existing finish shall be carried out by the contractor without any extra cost from the department
70Taking down carefully existing unserviceable main switch / cutout / DBs of any type, capacity and description and removing materials from site and making good disturbed surfaces of walls, floors as per the existing finishes complete all as specified and directed.
71Supply and fixing in repairs DPX³ 100 MCCB with overload & short circuit thermal magnetic protection unit, 25 KA breaking Capacity, 4 Pole, 100 Amps complete all as specified and directed.
72Supply and fixing in repairs DPX³ 63 MCCB with overload & shortcircuit thermal magnetic protection unit, 25 KA breaking Capacity, 4 Pole, 63 Amps complete all as specified and directed.
73Supply and fixing in repairs DPX³ 125 MCCB with overload & short circuit thermal magnetic protection unit, 25 KA breaking Capacity, 4 Pole, 125 Amps complete all as specified and directed.
74M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 4 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 4 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 4 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed.
75M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 6 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 6 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 6 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed.
76M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 10 Sqmm nominal area and drawing into existing surface / recessed, PVC / Steel conduit including PVC insulated multistranded copper conductor 10 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed.Note - Three run of 10 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed.
77M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 4 Sqmm nominal area and drawing into PVC casing caping with all fittings, PVC junction boxes etc and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 4 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed.Note - Three run of 4 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed.
78M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 6 Sqmm nominal area and drawing into PVC casing caping with all fittings, PVC junction boxes etc and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 6 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed.Note - Three run of 6 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed.
79M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 4 Sqmm nominal area and drawing into existing surface / recessed, PVC / Steel conduit including PVC insulated multistranded copper conductor 4 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note - Three run of 4 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed.
80M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 6 Sqmm nominal area and drawing into existing surface / recessed, PVC / Steel conduit including PVC insulated multistranded copper conductor 6 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 6 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed.
81M & L for three phase submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 6 Sqmm nominal area and drawing into PVC conduit with all fittings, PVC junction boxes etc and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 6 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed.Note - 05 run of 6 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed.
82M & L for three phase submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 6 Sqmm nominal area and drawing into existing surface / recessed, PVC / Steel conduit including PVC insulated multistranded copper conductor 6 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed.Note - Five run of 6 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed.
83M & L for three phase submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 10 Sqmm nominal area and drawing into existing surface / recessed, PVC / Steel conduit including PVC insulated multistranded copper conductor 10 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed.Note- Five run of 10 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed
84Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed.
85S & F in repairs PVC rigid non-metallic conduit of dia 20 mm dia inclusive of all tees, bends, elbows reducers, junction box etc and fixing accessories such as couplers, lock nuts, saddles, etc for telephone cable, TV cable and public address system complete all as specified and directed by Engineer-in-Charge.
86S & F in repairs PVC rigid non-metallic conduit of dia 25 mm dia inclusive of all tees, bends, elbows reducers, junction box etc and fixing accessories such as couplers, lock nuts, saddles, etc for telephone cable, TV cable and public address system complete all as specified and directed by Engineer-in- Charge.
87Labour for taking down of unserviceable ceiling fan of any sweep and make after disconnecting cable end terninal from ceiling rose, dismantling blades and hanging serviceable fan at same location of any sweep, make by connecting cable end terminal to ceiling rose, after fixing blades at site with fan, testing for smooth running complete all as specified and as directed.Note : Transportation to & fro involved of unserviceable ceiling fan to deposit in EM Store yard Powai and back to site hanging serviceable fan after collecting from store is deemed to be included with unit rate.
88Servicing / over hauling of ceiling fan 230 Volts of any make and sweep, along with following others repairs.a) Dismantaling of ceiling fan complete part by part carefully, testing stator coils, degreasing bearing and display all the parts without damaging any portion for inspection of Engineer-in- Charge to ascertain the serviceability of existing partsb) Heating & varnishing to stator coils with super quality varnish and dried out properely with external heat as ordered & directed.c) Reassembeling of ceiling fan complete with all existing serviceable parts obtained against Item 1 (a), and new parts as required / ordered by Engineer in Charge.Note (i). Any Parts required for replacement shall be measured and paid seperately under appropriate item as ''Supply only'' (s) of this schedule. However labour element involved in replacement is included in unit rate quoted against this Item.(ii).Any unforeseen minor repair and minor parts that are not covered under Item No-88 (a) to (c) (Total cost less than Rs 100) but required to complete the repair work / smooth functioning of fan shall be deemed to be included with the unit rate. (iii) Transportation of fan to workshop for repair and back to site in E/M Bhandup store yard is deemed to be included with unit rate.(iii) Rewinding of stator coils of ceiling fan, where involved shall be measured and paid separately against relevant item of this schedule. (iv) 3 core PVC insulated and sheathed 0.75 Sqmm cable from ceiling rose to fan connector of adequate length (maximum upto 1 mtr) and (greasing the bearing with ball bearing grease where involved) shall deemed to be included in the unit rate.
89S & F Ball bearing rubber sealed for bottom cover complete all as specified and directed by Engineer-in-charge.
90S & F Ball bearing rubber sealed for top cover complete all as specified and directed by Engineer-in-charge.
91Material and labour for rewinding stator of ceiling fan 1200 / 1400 mm sweep with supper enamelled copper wire of existing gauge, and testing complete all as specified and as directed.
92M & L in replacement of ceiling fan capacitor 2.5 MFD with or without taking down the ceiling fan fixed at any height refixing in original position after repaired and connecting up, complete all as specified and as directed.
93M & L for taking out old paint of ceiling fan (any size) with paint remover liquid, preparing smooth surfaces for painting, cleaning all dust etc, filling cavities with filler, and Painting of complete ceiling fans including blades with synthetic enamel white rust proof paint by spraying complete all as specified and as directed.
94S & F ceiling fan down rods cut to required length as per site requirement of 15 mm dia GI pipe (medium grade) to the existing trusses of any height including necessary welding, drilling holes complete all as specified and as directed.
95Supply only gun metal bush suitable for ceiling fan of any sweep complete all as specified and directed.
96Supply only shackle clip assembly with rubber bush reel and nuts, bolts and washers suitable for ceiling fan of any sweep complete all as specified and directed.
97Supply only PVC canopy top and bottom with tighten screw suitable for ceiling fan of any sweep complete all as specified and directed.
98Supply and fixing of OEM compatible ceiling fan blades metal body for 1200 mm sweep fan complete all as specified.
99Taking down and opening / dismantling of exhaust / ventilation fan, 200 / 250 / 300 mm sweep and taking out old unserviceable winding and M & L for rewinding the same with super enamelled copper wire of existing / same gauge including all insulating material required as per standard practice, varnishing the same and drying, cleaning the fan bearing / bushing and greasing / oiling and reassembling, testing complete including spray painting with one coats of synthetic enamel paint after preparing rusted surface and refixing, testing and commissioning complete all as specified and directed by the Engineer-in-Charge. Note : 1) Spare parts like capacitor, bush and bearing will be measured and paid separately under respective items. 2) winding fan warrenty will be one year. Note :- To be fixed at min height of 12 m building / store house
100All as per above item no. 99 but size for 450 mm sweep Exhaust fan.
101Supply and fixing bush suitable for existing exhaust fan of 200 / 250 / 300 mm sweep complete all as specified and directed.
102Supply and fixing bearing suitable for existing exhaust fan of 400 mm sweep complete all as specified and directed.
103Supply and fixing bush suitable for existing exhaust fan of 400 mm sweep complete all as specified and directed
104Supply and fixing bearing suitable for existing exhaust fan 200 / 250 / 300 mm sweep complete all as specified and directed.
105Supply and fixing shaft suitable for existing exhaust fan 200 / 250 / 300 / 400 mm sweep complete all as specified and directed.
106Supply and fixing in repair 250 / 300 mm sweep PVC exhaust fan blade all as specified and directed.
107Supply and fixing in repair exhaust fan motor 170 to 250V, 50 Hz (200 mm Sweep to 300 mm Sweep) suitable capacity and size all as specified and directed.
108Supply and fixing in repair 250 / 300 mm sweep PVC exhaust lovers suitable for any size and model complete all as specified and directed.
109Supply and fixing capacitor 1.5 MFD capacity 230 volts complete all as specified and directed.
110Supply and fixing in repair 250 / 300 mm sweep 3 or 4 blade metal body fan blade suitable for any size and model complete all as specified and directed.
111Supply and fixing in repair 250 / 300 mm sweep GI sheet exhaust lovers suitable for any size and model complete all as specified and directed.
112Supply and fixing in repair 400 mm sweep GI sheet exhaust lovers suitable for any size and model complete all as specified and directed.
113Supply and fixing in repair 400 mm sweep 4 blade metal body fan blade suitable for any size and model complete all as specified and directed.
114Taking down and opening / dismantling of BLDC ceiling fan, 1200 / 1400 mm sweep and taking out old unserviceable winding and M & L for rewinding the same with super enameled copper wire of existing / same gauge including all insulating material required as per standard practice, varnishing the same and drying, cleaning the fan bearing / bushing and greasing / oiling and reassembling, testing complete including spray painting with one coats of synthetic enamel paint after preparing rusted surface and refixing, testing and commissioning complete all as specified and directed by the Engineer-in-Charge. Note : 1) Spare parts like capacitor, bush and bearing will be measured and paid separately under respective items. 2) Winding fan warranty will be of one year.
115Supply and fixing in repair BLDC fan control electronic card for 1200 mm sweep ceiling fan as per model complete all as specified and directed.
116Supply and fixing in repair BLDC fan electronic remote for 1200 mm sweep ceiling fan as per model complete all as specified and directed.
117Supply and fixing in repair modular AC box with 25A SP MCB, metal enclosure & unbreakable heavy duty with ISI plug top complete all as specified and directed.
118Supply and fixing in repairs electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed.
119Supply and fixing in repairs electronic meters temper proof LCD display with polycarbonate cover, 3 Phase 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed.
120Supply and fixing, fresh air (ventilation) fan plastic body of 300 mm sweep, AC single phase, 240V, 50 Hz, input voltage, 140-285, with louvers and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to PVC connector block of fan and taking down old exhaust fan carrying to deposit in AGE E/M Bhandup store yard complete all as specified and directed.
121Supply and fixing, fresh air (ventilation) fan plastic body of 250 mm sweep, AC single phase, 240V, 50 Hz, input voltage, 140-285, with louvers and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to PVC connector block of fan and taking down old exhaust fan carrying to deposit in AGE E/M Bhandup store yard complete all as specified and directed.
122Supply and fixing, fresh air (ventilation) fan plastic body of 200 mm sweep, AC single phase, 240V, 50 Hz, input voltage, 140-285, with louvers and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to PVC connector block of fan and taking down old exhaust fan carrying to deposit in AGE E/M Bhandup store yard complete all as specified and directed.
123Supply and fixing, fresh air (ventilation) fan plastic body of 150 mm sweep, AC single phase, 240V, 50 Hz, input voltage, 140-285, with louvers and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to PVC connector block of fan and taking down old exhaust fan carrying to deposit in AGE E/M Bhandup store yard complete all as specified and directed.
124Supply and fixing, fresh air (ventilation) fan plastic body of 100 mm sweep, AC single phase, 240V, 50 Hz, input voltage, 140-285, with louvers and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to PVC connector block of fan and taking down old exhaust fan carrying to deposit in AGE E/M Bhandup store yard complete all as specified and directed.
125M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including GI strip 25×4 mm as earthing lead by means of bolts, nuts, checknuts and washers of galvanized iron or steel drawn through GI pipe 40 mm dia medium grade pipe for protection of G.I earth strip, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors /plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate, including PCC (1:2:4) type B-1 earth pit with precast RCC cover in cement concrete (1:2:4) type B1 with handle, with GI 20 mm dia medium grade pipe for watering and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion complete all as specified and as directed.
126M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including galvnised steel earthing lead wire 4 mm dia, by means of bolts, nuts, check nuts and washers etc; GI pipe 15 mm dia medium grade pipe for protection of GI earth lead wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors / plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate, including PCC (1:2:4) type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion complete all as specified and as directed.Note for Item No. 125 & 126 : Item cost includes cost of dismantling unserviceable earthing pit above ground level with earthing electrode and making good as per existing ground.
127S & F in repairs heating element of 1.5 kw / 2.0 kw / 3.0 kw including rubber washer ISI marked any type complete all as specified and directed.
128Taking down of water storage Geyser and refixing after repair at its own position or other location including new holdfastner complete all as specified and directed.
129S & F in repairs thermostat for water storage heater SP 230V complete all as specified & directed.
130S & F in repairs non return valve 15 mm dia & connecting of complete heavy duty ISI marked complete all as specified & directed
131S&F in repairs safety valve / high pressure release valve 15 mm dia ISI marked complete all as specified & directed
132S&F in repairs indicator neon lamp 230 volts SP square or round complete all as specified & directed
133S & F in repairs connection pipe of 45 cm long stainless steel anti slip technology, anti explosion design complete all as specified & directed.
134Supply and fixing in repair of LED street light fitting new generation energy saving and environment friendly long life LED 70 Watt with following specifications : 230 V AC outdoor type, top opening , IK-08, seperate driver compartment, input voltage AC 140V-300V, power factor > 0.95, beam angle 140 x 90 degree, colour temperature 6500 K, rated life 50,000 Hours, pressure die cast aluminum hosing and heat resistant with tempered PC cover with integrated lens, efficiency 145 lumen/watt, BIS Certified to LM-79/LM-80 lamp with impact and corrosion resistant including thermal management, over-voltage, short circuit, open circuit and surge protection in multiple optics complete with IP 66 protection including bracket of suitable size with 5 years manufacture warrenty complete all as specified and as directed by Engineer-in-charge.
135Supply and fixing in repair of LED building security light fitting new generation energy saving and environment friendly long life LED 35 Watt with following specifications : 230 V AC outdoor type, top opening, IK-08, seperate driver compartment, input voltage AC 140V-300V, power factor > 0.95, beam angle 140 x 90 degree, colour temperature 6500 K, rated life 50,000 Hours, pressure die cast aluminum hosing and heat resistant with tempered PC cover with integrated lens, efficiency 120 lumen/watt, BIS Certified to LM-79/LM-80 lamp with impact and corrosion resistant including thermal management, over-voltage, short circuit, open circuit and surge protection in multiple optics complete with IP 66 protection including bracket of suitable size with 5 years manufacture warranty complete all as specified and as directed by Engineer-in-charge.
136Taking out existing unserviceable bracket & supply and fixing in repairs pipe bracket made out of 25 mm / 40 mm dia GI pipe, medium grade, upto 1.5 mtr long, bent to shape and fixed on existing pole / wall including necessary clamp / saddle and fixing by screw / bolt complete all as specified and directed. Please Enable Macros to View BoQ information
137Taking out existing unserviceable bracket & supply and fixing in repairs pipe bracket made out of 25 mm / 40 mm dia GI pipe, medium grade, upto 1.5 mtr long, bent to shape and fixed on existing pole / wall including necessary clamp / saddle and fixing by screw / bolt complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57850407
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 31-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Day To Day Preventive Maintenance And Repair Internal Electric Supply, Switch Board, Switches, Mcb, Mcb Dbs, Led Tube Lights, Post Top Lantern, Gate Lights, Frp Boxes, Electric Geysers, Air Circulators, Ceiling Fans And Exhaust Fans And Internal Point Wiring Of High Rise Building And Otm Accn At Nchc Powai Under Ge (Nw) Bhandup
Basic Detail
Tender No 8547/B
Bidding Type Tender
Location
City Mumbai Suburban
State Maharashtra
Key Dates
Publish Date 24 Oct 2026
Submission Date 31 Oct 2026
Open Date 02 Nov 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
2dafe28a-8766-416a-8bf4-af14b2854339.html
BOQ_888335.xls
TENDERDOCUMENTS_8547.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 31, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 3 days
Oct 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Nov 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

2dafe28a-8766-416a-8bf4-af14b2854339.html

xls

BOQ_888335.xls

pdf

TENDERDOCUMENTS_8547.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender