Tender For Repair/Main Of B/R & E/M Works Services Of Wsa At Af Stn Gorakhpur Under Ge (Af) Gorakhpur.
Tender Value
40 Lakhs
Estimated cost
Bid Submission
23 Oct 2026
12 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gorakhpur → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Main Of B/R & E/M Works Services Of Wsa At Af Stn Gorakhpur Under Ge (Af) Gorakhpur.
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Garrison Engineer (AF) Gorakhpur Name of Work: REPAIR/MAIN OF B/R & E/M WORKS SERVICES OF WSA AT AF STN GORAKHPUR UNDER GE (AF) GORAKHPUR. Contract No.: GE(AF)/GKP/E-73 OF 2026-27 File No.9524/E8 Serial Page No.15 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of items Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Demolition for Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed . |
| 3 | M&L for Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed . |
| 4 | M&L for rendering 15 mm thick in CM ( 1:3 ) plaster on brick wall, finish even and smooth without using extra cement complete all as specified. |
| 5 | M&L cement concrete 1:2:4 type B1 using 20 mm graded aggregate as in flooring benching to drain, coping, bed block etc and the like edge slightly rounded or chamfered including necessary use and waste of form work complete all as specified and directed. |
| 6 | M&L for preperation of newly plastered surfaces of wall es etc and applying two coats of exterior emulsion paint in camouflage pattern (One, two or more colour combination) over 2mm thick cement based putty complete all as specified and directed . |
| 7 | Demolition floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified & directed. |
| 8 | M&L for non-skid ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1 :6 complete all as specified and directed. |
| 9 | S&F Machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 20mm thick screed bed in CM 1 :4 complete all as specified and directed. |
| 10 | M&L for preparation of old painted steel surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint or (one ,two or more colours) in camouflage pattern complete all as specified and as directed by Engr-in-Charge. |
| 11 | Taking down cement plaster on brick wall and ceiling including raking out joints hacking for key scrubbing down with water etc complete all as directed. |
| 12 | M&L for rendering 05 mm thick in CM ( 1:4 ) plaster on Ceiling/concrete surfaces finish even and smooth without using extra cement complete all as specified. |
| 13 | M&L for applying 02 coat of white wash including preparation of new surface of ceiling complete all as specified |
| 14 | M&L for rendering 15 mm thick in CM ( 1:6 ) plaster on wall / concrete surfaces finish even and smooth without using extra cement complete all as specified. |
| 15 | M&L for applying 02 coat of white wash including preparation of newly surface of wall complete all as specified |
| 16 | M&L for applying 01 coat of white wash including preparation of old undecorated plastered surface on ceiling and Washing, rubbing down and stopping of distempered and painted surfaces, complete all as specified |
| 17 | M&L for complete removal of existing treatment of wall and applying two coats of white wash over one coat of priming on old decoratice surface complete all as specified and as directed |
| 18 | M&L for preperation of old painted surfaces of wall by scrapping, washing, rubbing down & stopping etc of old painted surfaces and applying one coats of exterior emulsion paint in camouflage pattern (two or more colour combination) over 2mm thick cement based putty complete all as specified and directed . . |
| 19 | Dismentling of wall and ceiling board (fibre, pulp, insulation board/ slab/ blankets, any thickness including wooden cover fillets aluminium frame work all as directed |
| 20 | S&F anodised aluminium snap grid (size 605mm x605mm) frame work for false ceiling with hangers 6mm dia, galvanised iron (upto 1200mm length) adjuting level fixed to roof slab by means of ceiling cleats made out of galvanised iron flat 40mm x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long and fixing 4mm thick non asbestos fiber cement building boards on aluminium framework complete all as specified and directed. |
| 21 | Repair/ servecing / easing of hanger steel gate shutter (exc 7.00 m width and 8.25 m hieght) sliding/ rolling over wheels (minimum 06 Nos) on track at floor and rolling over rollers (minimum 08 nos) between framed MS track at top with following specifictions :-(i) Servicing of existing bush bearings mounted at both sides of each wheels and top rollers by claening, greasing etc. including all necessary arrangements of suppots/ shoring etc. for taking out wheels and rollers complete all as specified and directed.(ii) Cleaning, greasing and strengthening of tracks fixed over floor and realignment of track if required.(iii) Welding of guide bracket and other strutural steel member of gate as required.(iv) Realigning and refixing of wheels and rollers with cleaning and greasing etc. |
| 22 | S&F in repair 1.25 mm thickness of laths, steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and Two coat paint over one coat of primer; erected in position as indicated, complete: gear operated type with bevel gear box and crank handle complete all as spectified and as directed. |
| 23 | Dismantling/demolition and removal of mud in roofs, any thickness, including old tarfelt,plastering and leeping of any thickness as reqd at site complete all as specified and directed . |
| 24 | M&L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and Brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and directed. |
| 25 | M&L cement concrete type B1 (1:2:4) 20 mm graded aggregate average thickiness of 55mm on RCC roof slab complete all as specified and directed. |
| 26 | M/L rendering 15 mm in average thickness in CM 1:4 on RCC roof slab/terrace with mixing of integral water proofing compound @ 3% by weight of cement including finishing even and smooth without using extra cement. Note : WPC shall be measured and paid separately |
| 27 | Supply only water proofing compound as per complete all as specified and directed . |
| 28 | M&L for roof treatment using 3mm thick APP membrane with torching laid over bitumen based @ 3Sqm/litre priming coat using gas burner to head substrate keeping overlap margin of minimum 100mm as per manufacturer instructions (Dr Fixit Torchshield AP or equivalent) incl 15mm thick screed bed in CM 1:4 and covered with 20cmx20cmx 20mm thick PCC tiles pointed in CM 1:4 without pigment complete all as specified and directed. |
| 29 | M&L for 100 mm thick cement concrete type D-2, 1:4:8 using (40mm graded aggregate) complete all as specified and directed. |
| 30 | M&L sand filling under floors or in foundation including watering and consolidation complete all as specified and directed . |
| 31 | S&F machine pressed precast concrete interlockng paver block of any shape and size and colour confirming to IS 15658-2006 of 60 mm thickness M-35 grade laid using grey cement and pigment |
| 32 | Demolition of plain cement Concrete (unreinforced) in ground floors and roof and paving not exceeding 15 CM thickness (Below or above ground level), complete all as specified and directed . |
| 33 | Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed . |
| 34 | Removing excavated material exc 500 m and n exc 1.5 km and depositing where direced by Engr-in-charge complete all as specified and directed . |
| 35 | M&L for 75mm thick cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregate) as in plinth protection finished surface even and smooth without using extra cement complete all as specified and directed . |
| 36 | M&L for hardcore (broken stone or boulders) of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed . . |
| 37 | M&L forming construction/dummy joint 30mm deep x 10mm wide filled with sealing compound Grade 'B' |
| 38 | S&F in repair mild steel, plain, black sheet 1.60 mm thick in hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and directed. |
| 39 | S&F in repair framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 40 | M&L for repair to RCC chajja/facia/fins, roof projection by removing loose concrete including cleaning of exposed reinforced with wire brush and cutting/removing of rusted unsericeable reinforcement if any and providing new reinforcement inserting/welding or binding of reinfoced , applying a coat of forsect chemical - Nito bond ( for bonding of old & new cone) and provn of RCC 1:2:4 type B0, finishing surface even and smooth with applying 2 coats of Cement base paint over a coat of primer complete all as specified and as directed. (Note : formwork or scafolding as required at site deemed to be included in the rate.) |
| 41 | S&F in repair PVC (SWR) pipes single socketed of any length with rubber rings joints 110mm dia fixed to walls complete all as specified and directed |
| 42 | M&L 100mm thick plain cement concrete (1:2:4) type B-2 using 40mm graded stone aggregates as in flooring/ hard standing/ paved area etc finished even and smooth without using extra cement including spike rolling to surface or making impression of expanded metal whilst the concrete in green complete all as specified and directed. |
| 43 | M&L in repairs for Linoleum sheet 4.5mm thick , plain coloured, laid, sealed down with approved adhesive including stretching, cutting and fitting and all as specified and directed |
| 44 | Taking up or down 15mm dia GI steel tubing including connections complete all as directed. |
| 45 | Taking up or down 20mm dia GI steel tubing including connections complete all as directed. |
| 46 | S&F GI Tubes 15 mm dia ‘medium grade’, Concealed with all fitting including cutting chases, pinning in brick walls and making good. |
| 47 | S&F GI Tubes 20 mm dia ‘medium grade’, Concealed with all fitting including cutting chases, pinning in brick walls and making good. |
| 48 | S&F in repairs Vitreous china WHB, white, flat back, of size 550 x 400 mm including brackets, waste coupling 32mm, and waste Pipe, 32mm complete all as specified and directed. |
| 49 | S&F in repair pillar tap 15 mm, chromium plated, fancy type complete all as specified and directed |
| 50 | S&F in repair Soap dish holder of CP complete all as specified and directed. |
| 51 | S & F CP Towel Rail 600mm long fixed with and including Chromium plated brass screws and wooden/plastic cleats. complete all as specified and directed. |
| 52 | Supply and fix in repair 15 mm bore CP bib taps cast copper alloy with crutch or butterfly handles screwed down for iron pipes all as directed complete all as specified and directed. |
| 53 | Supplying approved earth (from out side MD land) with and incl Rough excavation not exceeding 1.5m deep and getting out in hard/dense soil removing excavated material to site from a distance exc 1.5 km and n exc.15km and filling under traverse wall, floor,paving or any other locations including spreading, levelling in layers n exc. 25cm, watering and well ramming complete all as specified and directed. |
| 54 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. for taking credit and making good disturbed surfaces of walls, floors, etc. |
| 55 | M&L point wiring complete copper conductor 1.5 Sq mm size (nominal area)PVC insuloated FRLS unsnearned cable 1100 V grade conforming to IS 694 drawn in and including 1.6 mm thick concealed ER W stove enameled rigid steel conduit conforing to IS:9537 of size not less than 25mm dia including flame proof fittings such as MS junction bos,. MS coupling uninors bends, reducers inspection albow seeling conduits, plugs etc and also including single core standed copper conductor 1.5 Sq mm PVC insulated unsheathed FRLS cable as earth wire to common earth adn connected to earth doily and body of the flameproof lumiaires an drawn in the same concealed conduit complete all as specified and directed for following:-(a) One flame proof light/ fan point controlled by single pole one way 10 Amp flame proof ON-OFF rotary switch. |
| 56 | All as per item above here in before but with copper conductor cable for one 3 pin socket outlet, 16 amp independent, with cable 2.5 sqmm size all as specified and directed. |
| 57 | S & F \Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V all as specified and directed. |
| 58 | S & F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A,250V, 2P+earth complete all as specified and directed |
| 59 | S & F in replacement old and UNSV LED light fitting 2x 16 watt flame proof , CMRI certified recommended for gas / vapour/ group of IIA& IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixture , driver, holder, connector etc . complete with all accessories prewired and including connecting up with three core flexible copper conductor cable of suitable size all as specified and directed. |
| 60 | Disconnecting and taking out old existing unserviceable street light fitting of any description and Supply & fixing Street light fitting IP-66 powder coated pressure die cast aluminium housing with high power LED as lighting source with heat resistant toughtened glass 70 W LED with 10kv surge protection complete with all assessaries of capacity 70 watt all as specified and directed. |
| 61 | Disconnecting and taking out old existing unserviceable junction box and S & F in repairs IP rated junction box made of impact resistance polycarbonate & heat resistant materials of available size , dust proof, water tight, light weight, acid resistant, corrotion proof insulated and shock proof, fire retardant, self extinguishing, helogen & silica free non toxic material, UV resistant with internally embedded gasket and fitted with required terminals alongwith complete all as specified and directed directed. |
| 62 | M&L for taking out and disconnecting of UPS (digital/analog type), 3 phase, 415 volts, AC, 50 Hz, 3 KVA and detecting the internal faults of following parts/assembly etc of any make and type and repair / replace the same defective parts of same type / capacity as OEM design and testing on load complete all as reqd and as directed :-(Note :- Cost of Spare parts/assembly will be paid inclusive in this quoted rate )(a) Intelligent slot,(b) SNMP card,(c) Transformer,(d) Auxillary circuit,(e) Communication port/EPO port,(f) Support time,(g) Suitable operating software package,(h) LCD/LED display information,(j) Buzzer alarm status,(k) Bypass switch,(l) Identification menu |
| 63 | M & L for servicing of split type AC of capacity 1.5/2 TR of any make including cleaning of filter on front side by removing dust, cleaning the condenser including fins, blower fan motor and checking and testing of all parts for its serviceability, oiling/greasing to condenser cum blower fan motors, replacing worn out rubber, bushes/rubber packing, rectification of unusual noise, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc and reassembling of complete AC including testing for smooth functioning Complete all as directed by Engineer-in-Charge. |
| 64 | S & F of Human Body Voltage Checker of Dimension 180 X 100 X 45mm,Power Supply-9V,Accuracy-10 %,Indicating Range-+/- 1999V,Resolution-1 Volt,Weight-300 grams complete all as specified and directed Total in Figures 23 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysOct 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender