Tender For Design, Build, Supply, Delivery, Installation, Testing, And Commissioning Of Additional Boat Charger Electrical Infrastructure At High Court Terminal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
05 Nov 2026
26 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
23600
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Design, Build, Supply, Delivery, Installation, Testing, And Commissioning Of Additional Boat Charger Electrical Infrastructure At High Court Terminal
BOQ
| Sl. No. | Item Description |
| 1 | Supply of following sizes of XLPE insulated PVC sheathed, FRLS earthed Aluminium conductor armoured power cable of 11 KV grade conforming to IS 7098 amended upto date.3C X 300 sq.mm. |
| 2 | Laying of one no. PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in recess/ surface/ cable tray/ wall with saddles, clamps and all other accessories as required 3C X 300 sq.mm. |
| 3 | supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required3C X 300sq.mm. |
| 4 | 2.5 MVA 11kV Transformer :Design, fabrication,Supply, installation, testing and commissioning of indoor type transformer enclosure with 11kV/433V 3 Ph, 50Hz, Dyn11, dry type, Transformer with IP23 enclosure, winding temperature alarm& trip and LV chamber suitable to terminate bus duct, complete with all fittings and accessories etc including louvers and as per specifications. It shall includes all necessary control cabling for alarm, tripping & indication, all internal cabling. The rate shall be inclusive of necessary civil works.Transformer Compartment: 2.5 MVA, 11kV/433V 3 Ph, 50Hz, dry type, Dyn11 Transformer, copper wound, Class F, indoor distribution Transformer with forced ventilation. Losses shall be as per ECBC guidlines.The transformer shall have off load tap changer range: + 10% to -10% in steps of 2.5%. The transformer shall have suitable enclosure for providing neutral CT of xxx/5A 15VA 5P10 on earthed star point with connector for connection Earth Fault relay. |
| 5 | 4000A,415V Indoor Bus Duct:Supply and Installation of following sandwitch type copper Bus Duct including necessary 90° Indoor Bend, Panel end termination with tinned copper flexible, Transformer end termination with tinned copper flexible, wall frame assemly with FRP seal of plate, Phase cross over chamber, adaptor box in accordance with electrical specification. Rates shall be inclusive of all structural steel as required for Brackets/mounting frames and necessary hardware/fastners. 415V, 2500A TPN Bus duct suitable for 50kA for 1Sec. Fault level (for 415V LT Panels) all the features of the bus duct shall be as per the tender specification |
| 6 | 4000A Power Control Center (PCC) Panel:Design, fabrication,Supply, installation, testing and commissioning of indoor type PCC Floor mounted, Indoor ,415V, IP 42 , Form 4b,Enclosure Material : Sheet Steel 2mm CRCA , Powder Coated with RAL 7032 Seimens,Gray Paint Shade after 7 tank treatment, Mounted on black painted 75mm Base Channel including internal wiring with suitable size wires/cable, interconnection, including following components as per drawing and technical specifications.The panel shall be with top entry to receive incoming Bus duct & outgoing cable.All the Bolt/Nus shall be of SS316Incomer: 4000A, FP ACB 50 kA Thermal-magnetic based, RS 485 communication facility- 1 No, Instruments(incomer): 3P,4A MCB - 1 nos, RYB indication lamp, LED type - 1 set, ON-OFF-TRIP indicator -1 set, Digital Multi function meter with Acc Cl-1 with RS 485 communication - 1 no, (0-500)V voltmeter, Acc. class 1 with 90 deg defl. scale - 1 Nos, (0-4000)A ammeter Acc. class 1 with 90 deg defl. scale - 1 Nos,4000/ 5A 15VA class 1 resin cast CT - 1 set, Busbar: 4000A ,50 kA TPN busbar chamber with Aluminium busbar,Surge Protection Devices for Main Panel: Class B & Class C -1 setOutgoings: MCCB with microprocessor based release with LSIG protection, 1000A,TPN, 50kA - 5 Nos, Instruments(Outgoings): 4A MCB - 5 nos, ON-OFF-TRIP indicator - 5 set, Three phase digital MFM meter Acc Cl-1 and having RS 485 communication - 5 no, 630/5A 15VA class 1 resin cast CT-5 set. |
| 7 | Boat Charger LT Switch Board:Supply of LT Panel Board, cubicle type, made out of 2 mm thick CRCA sheet,totally enclosed, IP 65 form 4b, free standing, floor mounting, dust and vermin proof, outdoor, compartmentalised, suitable for operation on 3phase , 415 V, 50 Hz AC system with busbars, including internal wiring with suitable size wires/cable, interconnection, duly powder coated with seven tank process etc., including following components as per drawing and technical specifications.The panel shall be with bottom entry to receive incoming & outgoing cableAll the Bolt/Nus shall be of SS316.Incomer: 1000A, FP ACB 50 kA Thermal-magnetic based, RS 485 communication facility- 1 No, Instruments(incomer): 3P,4A MCB - 1 nos, RYB indication lamp, LED type - 1 set, ON-OFF-TRIP indicator -1 set, Digital Multi function meter with Acc Cl-1 with RS 485 communication - 1 no, (0-500)V voltmeter, Acc. class 1 with 90 deg defl. scale - 1 Nos, (0-1000)A ammeter Acc. class 1 with 90 deg defl. scale - 1 Nos,1200/ 5A 15VA class 1 resin cast CT - 1 set, Busbar: 1000A ,50 kA TPN busbar chamber with Aluminium busbar,Surge Protection Devices for Main Panel: Class B & Class C -1 setOutgoings: MCCB with microprocessor based release with LSIG protection, 630A,TPN, 36 kA - 3 Nos, Instruments(Outgoings): 4A MCB - 3 nos, ON-OFF-TRIP indicator - 3 set, Three phase digital MFM meter Acc Cl-1 and having RS 485 communication - 3 no, 630/5A 15VA class 1 resin cast CT-3 set. |
| 8 | Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, FRLS armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.3.5C x 400 Sq. mm Al |
| 9 | Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required including supply and installation cable tray.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 10 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of XLPE insulated PVC sheathed aluminium/copper conductor cable of 1.1 kV grade as required.3.5C 400 Sq. mm Al |
| 11 | Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, FRLS armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.3.5C x 240 Sq. mm Al |
| 12 | Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required including supply and installation of cable tray.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 13 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 185 sq. mm and upto 400 sq. mm |
| 14 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm |
| 15 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of XLPE insulated PVC sheathed aluminium/copper conductor cable of 1.1 kV grade as required.3.5C 240 Sq. mm Al |
| 16 | Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, FRLS armoured Aluminium/Copper conductor cable conforming to IS 7098 (Part 1) amended upto date. |
| 17 | 3.5C x 35 Sq. mm Al |
| 18 | 3C X 2.5 sq.mm Cu |
| 19 | Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required including supply and installation of cable tray.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 20 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of XLPE insulated PVC sheathed aluminium/copper conductor cable of 1.1 kV grade as required. |
| 21 | 3.5C 35 Sq.mm Al |
| 22 | 3C X 2.5 sq.mm Cu |
| 23 | Supply,laying and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required. |
| 24 | 50mmX6mm GI |
| 25 | 25mm x 6 mm GI |
| 26 | 25mm x 3 mm Cu |
| 27 | Supplying and laying following GI or copper strip(tinned at the points of contacts) / wire at 0.6m below ground level including excavation and refilling for conductor earth electrode including welding etc as required. |
| 28 | 50mmX6mm GI |
| 29 | 25mm x 6 mm GI |
| 30 | 25mm x 3 mm Cu |
| 31 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 32 | Supply,installation ,testing and comissioning of maintenance free earthing using 4 mtrs length,20mm dia 250 microns molecularly copper bonded steel rod, stainless stell connectors and fasteners for connecting earth strip.The earth electrode shall be filled with earth enhancing compound (12.5 kg mineral compound / 22.6 kg low resistivity graphite compound).FRP (UFE FRP)Earth electrode inspection chamber with heavy duty cover should be used to cover the Earth Rod. The dimension shall be 300mmx 300mmx 300mm with a weight bearing capacity of 15KN.The item shall be inclusive of installation charges,including digging bore,providing all required accessories like terminal connector,screw for fixing earth pit cover etc. |
| 33 | Supply and installation of required size & required runs of 1.1 kV grade PVC insulated FRLS sheathed,multicore bright annealed stranded copper conductor,unarmoured,flexible cable conforming to IS 694 (amended up to date) and IS:8130 (amended up to date) as per technical specification which shall run from the Boat charger LT Panel Board to EVSE Module in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required or laying in RCC/ HUME/ METAL/ISI marked HDPE pipes with suitable size of 10 kgf/cm2 conforming to as per IS 4984,1985 PE-100 including all fittings and tees, elbows, bends, reducers, end caps, complete including supply and installation of pipes etc. in complete as required and technical specification. Necessary saddles, plugs, coupling, MTA etc. including price of all jointing materials, bolts, nuts, rubber washers, ferrule, pipe supports, hire of tools, cutting and finishing etc. shall also to be supplied and installed as per the requirement and specification. Providing, laying and fixing suitable dia RCC pipe NP 2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching and refilling etc. as required also covered in the scope. The work also includes the supply, installation of cable termination with all accessories including double compression cable glands, lugs suitable for 1.1kV grade as required.Size: 4Cx120sq.mm Copper cable |
| 34 | Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 35 | Supply and fixing anodised aluminum glass framed shock treatment chart. |
| 36 | Supply and fixing of First aid box |
| 37 | Supply of Rubber hand gloves suitable for 11 KV. |
| 38 | Supply and fixing of of fire retardant/extinguishing electrical insulated synthetic mat of 2m x 1m x 2 mm for 3.3kV grade thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 3.3kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound . |
| 39 | Supply and fixing of fire retardant/extinguishing electrical insulated synthetic mat of 2m x 1m x 2.5 mm for 11kV grade thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 11kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound . |
| 40 | Supply of ISI marked HDPE pipes with following size of 10 kgf/cm2 conforming to as per IS 4984,1985 PE-100 including all fittings and specials such as tees, elbows, bends, reducers, end caps,complete so as to withstand the internal design pressure of 10 fkg/cm2 as directed by Engineer -in-Charge.120 mm dia (OD) |
| 41 | Laying, jointing and hydrostatically testing ISI marked HDPE pipes with following size of 10 kgf/cm2 conforming to as per IS 4984,1985 PE-100 with saddles, plugs,coupling, MTA etc.including cost of all jointing materials, bolts, nuts, rubber washers, ferrule, pipe supports, hire of tools, cutting and finishing of HDPE pipe etc.as required. (including excavation, sand cushioning, protective covering and refilling the trench etc as required.) 120 mm dia (OD) |
| 42 | Disconnection of cable, dismantling, Loading, transporting, unloading of the following items from the terminal DG room to the proposed new location in front of High court water metro terminal including exhaust pipe etc. in complete.160 kVA DG set along with all its accessories |
| 43 | Disconnection of the cable and shifting the following items from the existing location to proposed new location inside the Electrical room of High court water metro terminal including re-installation and re-connection of cable.25 kVAR, 415V APFC Panel |
| 44 | liasioning charges for getting initial scheme approval from EIG |
| 45 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 46 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 47 | 450 mm width X 50 mm depth X 2.0 mm thickness |
| 48 | 600 mm width X 50 mm depth X 2.0 mm thickness |
| 49 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 50 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 51 | 450 mm width X 50 mm depth X 2.0 mm thickness |
| 52 | 600 mm width X 50 mm depth X 2.0 mm thickness |
| 53 | Supplying and installing following size of perforated Hot DippedGalvanised Iron cable tray “Tee” (galvanisation not less than 50microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required |
| 54 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 55 | 450 mm width X 50 mm depth X 2.0 mm thickness |
| 56 | 600 mm width X 50 mm depth X 2.0 mm thickness |
| 57 | Supplying and installing following size of perforated Hot DippedGalvanised Iron cable tray “Cross members” (galvanisation not less than 50microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required |
| 58 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 59 | 450 mm width X 50 mm depth X 2.0 mm thickness |
| 60 | 600 mm width X 50 mm depth X 2.0 mm thickness |
| 61 | Supplying and installing following size of perforated Hot DippedGalvanised Iron cable tray “REDUCERS” (galvanisation not less than 50microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required |
| 62 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 63 | 450 mm width X 50 mm depth X 2.0 mm thickness |
| 64 | 600 mm width X 50 mm depth X 2.0 mm thickness |
| 65 | Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba / rubbish to the nearest municipal dumping ground.For door / window / clerestory window |
| 66 | Supply and installation of Hollow metal fire rated steel doors as per IS 3614 part-1 & part-2 for stability and integrity. Pressed Galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI or ARAI for maximum rating of 2hrs with vision panel. Test certificates should be available for vision panels as part of the fire door assembly. Independent glass test certificates will not be accepted. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied should be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory by approved manufacturer. Colour of the door unit shall be RAL 7040. a. Door frame shall be Single rebate frame profile of size 125 x 60mm made out of 1.50mm minimum thick galvanized steel sheet. Frames shall be mitered, and field assembled with self-tabs. Frames to have in build grooved sealing system and shall be site fitted with EPDM gasket as standard. All provision should be mortised, drilled, and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be filled with PUF or with cement & sand slurry as recommended by the manufacturer of the engineer. |
| 67 | b. Door leaf shall be 46mm thick fully flush double skin door with or without vision panel. Door leaf shall be manufactured from 1.15mm (18guage) minimum thick galvanized steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core /96 density Rockwool insulation. c. All doors shall be factory prepared with necessary reinforcement for hinges, locks, handles, door stopper and door closers. The required hardware details per door is as follows: - • SS ball bearing hinges of size 100x75x3mm. Minimum 03Nos for 2100mm height. In each panel,• Hydraulic door closer – 1No per door leaf.• Door stopper – 1 No per door leaf • Mortise sash lock with SS liver handles (1 set for each panel) side with key operationThe edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. All hardware shall be provided GEZE brand or equivalent fittings including all hardware’s in SS shall be of 304 grade with fire rating standards. d. Vision panel wherever applicable should be provided as per manufacturer’s recommendation with a clip-on arrangement. The glass should be 5mm clear borosilicate fire rated glass of relevant rating of the door by Approved hardware manufacturer / Supplier. Size of the vision panel of size 200x300mm.Door size 1200 X 2100 |
| 68 | Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock |
| 69 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 70 | Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 71 | Taking out existing CC interlocking paver blocks from footpath/ central verge,including removal of rubbish etc. and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 72 | Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 73 | Soling with soling stone of size 150 to 75 mm brokenstone and binding materials, including hand packing and wedging them tightly so that the whole is formed as a solid mass, spreading binding material in 12mm thick layers and sweeping the same to fill the voids,watering profusely and consolidating with hand rammer/ plate vibrator etc complete as per the direction of Engineer-in - Charge. |
| 74 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 75 | Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns |
| 76 | Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- minimum cement content is @ 380 kg/ cum. All work upto plinth level |
| 77 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 78 | Providing and fixing stainless steel ( Grade 316 min 2.1mm wall thick) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge,( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 79 | Welded steel wire fabric fencing with angle iron post of standard design placed and embedded in cement concrete blocks 45x45x 60 cm of mix 1:5:10 (1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size),every 15th post, last but one end post and corner post shall be strutted on bothsides and end post on one side only and struts embedded in cement concreteblocks 70x45x50 cm of the same mix, provided with welded steel wire fabric fixedbetween the posts fitted and fixed with G.I. staples on wooden plugs or tied to 6mm bar nibs with G.I. binding wire (cost of posts, welded steel wire fabric, painting,earth work in excavation and concrete to be paid for separately). |
| 80 | Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. |
| 81 | Welded steel wire fabric of required width having rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer (Priming & painting to be paid for separately) |
| 82 | Applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works |
| 83 | Applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat) |
| 84 | Providing, supplying, detailing, fabricating, transporting, erecting and aligning steel work in built up tubular sections YST 310 grade as per IS: 4923 hot dipped galvanised as per IS 2629 & IS 4759 at a facility prior approved by Engineer in charge to obtain layer thickness of at least 700 grams/sqm (approx 100 microns) including cutting, hoisting, fixing in position, welded and bolted including special shaped washers etc. complete with electric resistance or induction butt welded tubes, closing all the open ends properly with same material including making good the defects after errection such as re-painting with galvanising paint etc. including the cost and conveyance of galvanisation, all materials, labour charges, lead, lift etc complete as directed by Engineer in Charge at all levels. |
| 85 | Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/m2 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 26 daysNov 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 28 daysTender Documents
Download All (ZIP) ↓
Disclaimer