Tender For Provn Of Installation Of 04 Fire Hydrants At Sasf At Lgj Mil Stn Under Ge Lalgarh Jattan

Issued by Statutory Bodies & Commissions/Committees · Ganganagar, Rajasthan
Tender Value
44.50 Lakhs
Estimated cost
Bid Submission
22 Oct 2026
19 days left
EMD
89000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ganganagar → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Installation Of 04 Fire Hydrants At Sasf At Lgj Mil Stn Under Ge Lalgarh Jattan

BOQ

Name of Work:- PROVN OF INSTALLATION OF 04 FIRE HYDRANTS AT SASF AT LGJ MIL STN UNDER GE LALGARH JATTAN
Sl. No. Item Description
1Supplying, laying, testing & commissioning of 'C' class heavy duty 100 mm MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. ,anticorrosive treatment with coaltar/asphalt tape as per IS 10221 for underground laying & fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade of following sizes complete as required.
2Supplying, laying, testing & commissioning of 'C' class heavy duty 80 mm MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. ,anticorrosive treatment with coaltar/asphalt tape as per IS 10221 for underground laying & fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade of following sizes complete as required.
3Supplying, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Grooved fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :(a ) 25 mm dia
4Supply and fixing fire hydrant landing valve type A (single head outlet) gunmetal of 80 mm dia landing valve with 63 mm dia female outlet complete and 80 mm inlet with rubber blank cap and chain as per IS 5290-1983, suitable for IS 903 complete all as specified and directed by Engr-in-charge.
5Supplying, fixing, testing and commissioning of 100 mm bore butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
6Supplying, fixing, testing and commissioning of 80 mm bore butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
7Supplying, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber, gasket,GI bolts, nuts, washers etc.as required :(a) 100 mm dia.
8Providing, installation, testing and commissioning of stainless steel Ystrainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.(a) 100 mm bore
9Supply, fixing, testing and commissioning of forge brass ball valves 25 mm dia with screwed ends lever operated, conforming to IS standard complete all as directed by Engr-in-charge.
10Supplying and fixing 63 mm dia, 30 m long RRL hose pipe with 63 mm dia male and female gun metal couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
11Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as directed.
12Supplying and fixing first-aid Hose Reel 30 mtr with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585. 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket
13Supply, fixing, testing and commissioning of pressure switchs with accessories shall be of approved make and design and chall actuate ('Cut-off and/or 'make contact' as required) at pre-set pressures with isolation valve complete all as specified and directed by Engr-in-charge.
14Supply, fixing, testing and commissioning of pressure gauges with controlling cocks etc shall be of approved makes having pressure range, bourndon material and 100 mm dial size with isolation valves on discharge pipe of each pump complete all as specified and directed by Engr-in-charge.
15Providing supply, erection and installation of fire house cabinet to be mounted externally near the hyrdant post fabricated from 160 SWG MS sheet of approx size 1000 mm X 800 mm X 350 mm with canopy, door with 4 mm glass encased in heavy grade rubber beading, a key box in built in the box, suitable to accomadate one hydrant valve one branch nozzle and two 30 mtrs hose, weather proof, finished with post office fire red colour (sample to be approved prior to entire supply ) complete all as specified and directed by Engr-in-charge.
16Providing, fixing, testing and commissioning standard fireman's axe with heavy insulated rubber handle tested for 20000 watts (Conforming to I.S. 926).
17Providing & fixing flow switch of 100 mm M.S. pipe including connection etc as required.
18Supplying, installation, testing and commissioning of Electric driven MainFire Pump suitable for automatic operation and consisting of following,complete in all respects, as required :(a) Horizontal type, single stage, centrifugal, split casing pump of cast ironbody & bronze impeller with stainless steel shaft, mechanical sealconforming to IS 1520.(b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supplywith IP 55 protection for enclosure, horizontal foot mounted type withClass-'F' insulation, conforming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard, foundationbolts etc. as required.(d)Suitable cement concrete foundation duly plastered with anti vibrationpads.(e) 1620 lpm at 35 m Head
19Providing supply, erection and insatallation of structural steel including 8mm thick MS Plate, ISMC, ISA, M14, 110 long Anchor Fastners with one coat of RED LEAD primer and two coat of Black paint complete
20Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 3.15 mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required:INCOMING:63 Amps. MCCB (25 KA) -01 NoAmmeter with CTs 400/5A class-IOne Digital Volt meter (0-500 V) with selector switch.Set phase indication lights (R, Y, B)BUS BARS:-150 Amps. TP&N aluminium bus bars (25 KA)OUT GOINGS:-63 A, MCCB TPN (25KA)- (02 Nos)fully automatic Star Delta starters suitable for 22 KW Pump Motor with suitable capacity MN type over load relay, timer push buttons and Auto/Manual selector switch.(02 Nos)Three panel Digital type Amp. Meters, one for each motor with ASS CTS etc.Three sets of On/Off –neon indicating lamp.All interconnecting power and control wires/cable suitable size within the panel and from panel to motors diesel engine, pressure switches, level switches, cable tray, pipes etc. including brass glands termination within fire pump house.SYSTEM CONTROLLERDesigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification
21Earthing complete with galvanised mild steel earth plate electrode 600X600X6.3 mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate electrode at a depth not less than 1.5m below normal ground level and including GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate electrode at one end and connected to metallic bodies of HT/LT equipments etc at the other end, earth strip encased in and including 40 mm bore GI medium grade pipe with all fittings from top of earth plate electrode to body of equipment fixed with and including 25x 6mm flat iron clamps, bolts, nuts and washers and including providing watering pipe 20mm bore GI pipe medium grade from Bottom of concrete pit to top of earth plate electrode complete all as specified and shown in electrical plate No 3 of MES SSR Part-I. The scope of work includes necessary excavation and earth work in any type of soil, removal of soil upto 50 metre, PCC pit with precast RCC cover, charcoal/salt, funnel, CI frame etc complete.(i)The concrete pit shall be made in PCC 1:3:6 type C-1, using 12.5mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover shown in electrical plate No 3 of MES SSR Part-I shall be provided. Reinforcement in RCC cover shall be of 8mm dia TMT bars laid @150mm c/c both ways.(ii) Item includes the cost of GI pipe for protection of earth wire including earth strip up to 7.5 Metre.(iii) Any variation of GI pipe and GI wire below or above shall be adjusted through deviation.
22Supply, installation, testing and commissioning of outdoor silent type diesel driven generating set to give an out put of 58.5 KVA /45.6 KW at 415 Volts, AC supply, 50 HZ, 3 phase, 4 wire directly coupled to diesel engine, liquid cooled, mounted on PCC Base with common base plate complete with fuel tank of adequate capacity, vibration damper, other accessories, acoustic enclosure, alternator etc complete all as specified and as directed . The DG set shall offer best fuel economy, best comprehensive warranty terms on entire package including rubber components and lowest maintenance cost to give most economical power solution. The DG set shall offer lowest noise levels in its range and shall be CPCB certified for emissions and noise compliance to give environment friendly power solution. The generator set shall meet the stringent exhaust emission tests as per latest CPCB norms without sacrificing fuel efficiency at normal operating loads of following make and technical specifications :- Engine Make - Cummins, Ruston, Greaves Cotton, Cater Pillar, Ashok Leyland, Mahindra or as approved by GEAlternator Make - Stamford, Jyoti, Alstom, Areva, Crompton Greaves, Leroy Somer or as approved by GE
23A. Engine Specifications:-Developing a net minimum power as per MoEF certified - 63 HP ( ± 5 % ), suitably matched with alternator to give a net directed output as specified. The engine shall be capable of delivering the required out put at 1500 RPM, as per BIS under NTP condition with provision of 10% overloading for one hours in every 12 hours of operation. The diesel engine shall also conform to IS : 10000/IS 1460/IS 13018/ISO : 3046/BS : 649 / BS : 5514 as amended upto date. The scope of supply includes :-(i) Electrical starter motor 12V DC(ii) Battery charging alternator(iii) MICO fuel system (iv) Dual spin-on fuel filter(v) Turbocharger(vi) Residential silencer(vii) Dry type air cleaner(viii) Shut-off coil with safeties for LLOP/HWT(ix) Dynamically balanced fly-wheel and flywheel housing(x) First fill of lube oil and coolant
24The technical data shall be all as specified below comprising of the following:-(i) BHP – suitable for giving a min power of 63 HP as per ISO 8528-Part-1/certified MoEF at the load terminals of alternator at 1500 rpm.(ii) All moving parts of the engine shall be mechanically guarded in such a manner that a human finger cannot touch any moving Part.(iii) Cooling – Liquid Cooled.(iv) Aspiration – Turbo Charged air cooled.(v) No. of Cylinders – 06.(vi) No. of cycles – 4 stroke.(vii) RPM – 1500.(viii) Fuel - HSD(ix) Fuel injection : Engine should have suitable fuel injection system in order to achieve low fuel consumption.(x) Starting System - 12V Electrical(xi) Lube oil specification – CI4 15W40.(xii) Governing specification – Electronic governor of class A1, as per ISO 3046/BS 5514 to maintain engine speed at all conditions of load.(xiii) Type of driven – Direct SAE flange coupling.(xiv) Battery capacity/rating – 12V DC, 88/90 AH.(xv) Any other item not included/specified, but is a standard design of the manufacturer.
25ALTERNATOR :- The diesel engine mentioned herein before shall be coupled through flexible coupling to an indigenous synchronous copper wound alternator mounted on a strong mild steel fabricated common base frame, with AVM pads suitable for continuous operation at 1500 RPM, 415VAC, 0.8 pf (lag) suitable for 50 HZ, 3 phase, 4 wire system, brushless type, screen protected revolving field, self excited self regulated through an AVR all as conforming to IS 4722, BS 5000 & IEC:60034 as amended upto date. The alternator shall have the following features :-(i) Voltage Regulation - ± 1.0% (max) in static conditions.(ii) Voltage variation - ± 5.0 %(iii) Class of Insulation - H Class(iv) Degree of protection - IP 23(v) Overload duration/capacity - 10% for one hour in every 12 hours of continuous use(vi) Frequency variation - As defined by the Engine Governor (± 1.0 %)(vii) Type of AVR( Automatic Voltage Regulator) - Electronic(viii) Stator Winding - Double layer lap(viii) Rotor - Dynamically balanced
26Contrl Panel with microprocessor based monitoring and control system :- The control panel should be manufactured with 14/16 gauge CRCA sheet with powder coated for weather proof and long lasting finishThe control panel consisting Multifunction digital meter displaying the following parameters :- (i) Voltage (Phase to Neutral & Phase to Phase).(ii) Current.(iii) Frequency.(iv) Coolant temperature.(v) Engine Oil pressure.(vi) Power Factor.(vii) KWHR.(viii) DG Set running Hrs.(ix) Engine RPM.(x) Battery voltage.(xi) MCCB of suitable rating with overload and short circuit protections.(xii) Push button-switch or ON/OFF Switch for ON and OFF operation.(xiii) Aluminium bus bar with suitable capacity with in and outgoing terminals.(xiv) LED Indicating Lamps set for 'Load On' and 'Set Running'.(xv)Insrument fuses duly wired and ferruled.
27System operation : Manual Mode.(i) In a manual mode, it shall be feasible to start-up the generator set by the operator on pressing the start push button(ii) Three attempts starting facility shall be operative for the start-up function(ii) Alternator circuit breakers closing and trip operations shall also be through operator only by pressing the appropriate button on the panel and closure shall be feasible only after alternator has built up full voltage. If the load is already on ‘mains’, pressure on ‘close’ button shall be ineffective.Engine shut down and alternator protection equipments : Following shut down and protection system with audio visual annunciation shall be integrated in the controller panel.1. For Engine :- (i) Low lubricating oil pressure.(ii) High/low coolant temperature.(iii) Engine over/under speed (iv) Low Fuel level.(v) High canopy temperatureFor Alternator :- (i) Over load) Short circuit) Earth fault) Over voltage) Over/Under frequency.
28Battery/Electrical System -(i) Batteries of 12 VDC, 88/90 AH with copper cable of suitable sizes should be supplied with Genset are generally dry and uncharged. First charging of uncharged batteries is very important and should be done from authorized battery charging centre. Initial charging should be done for 72 - 80 hours.(ii) Batteries should be placed on stands and relatively at cool place.FUEL TANK :- One No of sheet metal steel tank fabricated from 2mm thick MS sheet of suitable capacity to contain diesel for 8.0 Hrs running at full load including the following :-(i) Level indicator duly calibrated for indicating the quantity of diesel in the tank.(ii) Drain plug with 2 meter pipe for drain out.(iii) Fuel strainer.(iv) Pipe for fuel supply to engine.(v) Fuel pump manually operated for filling tank rotary type.
29Acoustic enclosure: The acoustic enclosure shall be fabricated out of the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet conforming to MoEF/CPCB norms suitable for out door installation in exposed to weather condition and to limit over all noise level to 75 dBA at a distance of 1 Mtr at 75 % load or as specified by MoEF(Ministry of Environment & Forest). The enclosure has the following features:-(a) The construction should be such that it prevents entry of rain water splashing into the enclosure and allows free & quick flow of rain water to the ground in the event of heavy rain.(b) The hinged doors shall be made form not less than 16 SWG (1.6 mm) thick CRCA sheet and will be made air tight with neoprene rubber gasket and heavy duty locks(c) Designed to have optimum serviceability (d) Air inlet louvers specially designed to operate at rated load made on special purpose CNC machines for consistency in quality and workmanship(e) Powder coated for long lasting service life and superior finish (f) Acoustic enclosures are supplied with built in Anti Vibration Mountings (AVM). As such Genset can be installed directly on the leveled surface(g) USE of special hardware for longer life(h) Insulation material meets exacting IS 8183 specifications for better sound attenuation.
30(j) Flush styling - no projection (k) Fluid drains for lube oil & fuel.(l) The canopy should be as compact as possible with good aesthetic look.(m) Fuel tank suitable for 8 hours of operation(n) The enclosure is of modular construction with the provision to assemble and dismantle easily at site.(o) The sheet metal components are hot dip seven tank pretreated before powder coating.(p) The enclosure is powder coated (inside as well outside) with a special pure polyester based powder. All nut and bolts/external hardware is made from stainless steel.(q) There is provision for filling fuel from outside the enclosure with locking arrangement.(r) External drain plugs are provided for draining Lub. Oil and diesel.(s) The doors are gasketed with high quality EPDN gaskets to prevent leakage of sound.(t) The door handles are locking type.(u) Sound proofing of the enclosure is done with high quality rock wool/mineral wool confirming to IS 8183. The rock wool is further covered with fiber glass tissue and perforated sheet.(v) A special residential silencer is provided within the enclosure to reduce exhaust noise.
31(w) Specially designed attenuators are provided to control sound at air entry and exit points.(x) Adequate ventilation is provided to meet total air requirement. If required, a blower is provided to meet total air requirement.(y) Temperature of enclosure does not exceed beyond 5 degree centigrade of ambient temperature.(z) The enclosure is provided with high enclosure temperature safety trip.(aa) Provision of emergency shut down from outside the enclosure.(ab) An arrangement for illuminating the enclosure from inside.(ac) The acoustic lining should be made up of high quality insulation material i.e. glass/mineral wool of minimum 50mm thickness and 75 Kg/cubic metre to 100 Kg/ cubic meter for sound absorption as per standard design of manufacturer’s to reduce the sound level as per CPCB norms. The insulation material shall be covered with fine glass fiber cloth and should be supported by perforated M.S. Sheet duly powder coated. Please Enable Macros to View BoQ information
32(w) Specially designed attenuators are provided to control sound at air entry and exit points.(x) Adequate ventilation is provided to meet total air requirement. If required, a blower is provided to meet total air requirement.(y) Temperature of enclosure does not exceed beyond 5 degree centigrade of ambient temperature.(z) The enclosure is provided with high enclosure temperature safety trip.(aa) Provision of emergency shut down from outside the enclosure.(ab) An arrangement for illuminating the enclosure from inside.(ac) The acoustic lining should be made up of high quality insulation material i.e. glass/mineral wool of minimum 50mm thickness and 75 Kg/cubic metre to 100 Kg/ cubic meter for sound absorption as per standard design of manufacturer’s to reduce the sound level as per CPCB norms. The insulation material shall be covered with fine glass fiber cloth and should be supported by perforated M.S. Sheet duly powder coated. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57847373
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 44.50 Lakhs
LAST DATE 22-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Installation Of 04 Fire Hydrants At Sasf At Lgj Mil Stn Under Ge Lalgarh Jattan
Basic Detail
Tender No 8937-38/GE/2026-27
Bidding Type Tender
Location
City Ganganagar
State Rajasthan
Key Dates
Publish Date 03 Oct 2026
Submission Date 22 Oct 2026
Open Date 24 Oct 2026
Finance
Tender Value 44.50 Lakhs
Tender Fee 500
EMD 89000
Exemption Available
Document List
BOQ_888258.xls
cede2767-f886-4093-995b-a42dd2362ccf.html
Tendernotice_1.pdf
tender_merged.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 03, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Oct 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Oct 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_888258.xls

html

cede2767-f886-4093-995b-a42dd2362ccf.html

pdf

Tendernotice_1.pdf

pdf

tender_merged.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders