Tender For Repair And Maintenance Of Unserviceable Lt Panels, Lt Switchgears Mccbs Earthing, Damaged Lt Underground Cables And Other Misc Items In D-Ii Zone, Cbs Gharota Under Age E/M Of Ge (S) Mamun.
Tender Overview
Project Description
Tender for Repair And Maintenance Of Unserviceable Lt Panels, Lt Switchgears Mccbs Earthing, Damaged Lt Underground Cables And Other Misc Items In D-Ii Zone, Cbs Gharota Under Age E/M Of Ge (S) Mamun.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-Oct-2026 | Corrigendum No. 1 | Date | 28-Oct-2026 |
| 2 | 28-Oct-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 04-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches in hard/dense soil, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, laying cables etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n. exc 1.5 m in depth and getting out complete all as specified and directed. |
| 2 | Excavating in trenches in hard/dense soil, n. exc. 1.5 m wide and exc. 1.5 m but n. exc.3 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and exc 1.5 m but n. exc. 3 m in depth and getting out complete all as specified and directed. |
| 3 | Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed. |
| 4 | Supply and laying DWC (double wall corrugated) pipe 40mm bore dia, as per IS-16205, laid for protection of cable, in trenches, floors etc. complete all as specified and directed. |
| 5 | Supply and laying DWC (double wall corrugated) pipe 50mm bore dia, as per IS-16205, laid for protection of cable, in trenches, floors etc. complete all as specified and directed. |
| 6 | Supply and laying DWC (double wall corrugated) pipe 63mm bore dia, as per IS-16205, laid for protection of cable, in trenches, floors etc. complete all as specified and directed. |
| 7 | Supply and laying DWC (double wall corrugated) pipe 90mm bore dia, as per IS-16205, laid for protection of cable, in trenches, floors etc. complete all as specified and directed. |
| 8 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.Note:- Volume of pole/strut embedded shall be deducted for the purpose of payment. |
| 9 | M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in pedestal/coping including necessary weathering and form work etc complete all as specified and directed. Note:- Volume of pole/strut embedded shall be deducted for the purpose of payment. |
| 10 | Supply and laying in repairs in trenches or fixed to wall/pole or passing through ducts or pipe, electric cable, LT 1100 volts grade heavy duty, XLPE insulated, armoured heavy duty, with aluminium conductor of size 6 Sqmm x 2 core or fixed to wall/pole or passing through ducts or pipe of any size, any core, complete all as specified and directed.Note: including taking out Bricks, sand cushioning Excavation, earth work, ducts etc shall be measured and paid seperatalety. |
| 11 | All as per description of srl item No. 10.00 here-in-before but size of cable 10 Sqmm 2 core |
| 12 | All as per description of srl item No. 10.00 here-in-before but size of cable 16 Sqmm 2 core. |
| 13 | All as per description of srl item No. 10.00 here-in-before but size of cable 6 Sqmm 4 core |
| 14 | All as per description of srl item No. 10.00 here-in-before but size of cable 10 Sqmm 4 core |
| 15 | All as per description of srl item No. 10.00 here-in-before but size of cable 16 Sqmm 4 core |
| 16 | All as per description of srl item No. 10.00 here-in-before but size of cable 25 Sqmm 4 core |
| 17 | All as per description of srl item No. 10.00 here-in-before but size of cable 35 Sqmm 3.5 core |
| 18 | All as per description of srl item No. 10.00 here-in-before but size of cable 50 Sqmm 3.5 core |
| 19 | All as per description of srl item No. 10.00 here-in-before but size of cable 70 Sqmm 3.5 core |
| 20 | All as per description of srl item No. 10.00 here-in-before but size of cable 95 Sqmm 3.5 core |
| 21 | All as per description of srl item No. 10.00 here-in-before but size of cable 120 Sqmm 3.5 core |
| 22 | All as per description of srl item No. 10.00 here-in-before but size of cable 185 Sqmm 3.5 core |
| 23 | All as per description of srl item No. 10.00 here-in-before but size of cable 240 Sqmm 3.5 core.Note for item No. 10.00 to 23.00:- Excavation & earth work, sand cushioning,Brick/DWC pipe/ GI pipe for protection pipe etc. shall be measured and paid for separately. |
| 24 | Supplying, jointing and connecting in repairs cable end termination joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 sqmm to 50 Sqmm 3.5 core, 1100 volts grade complete all as specified and directed. |
| 25 | Supplying, jointing and connecting in repairs cable end termination joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 70 sqmm to 120 Sqmm 3.5 core, 1100 volts grade complete all as specified and directed. |
| 26 | Supplying, jointing and connecting in repairs cable end termination joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 150 sqmm to 185 Sqmm 3.5 core, 1100 volts grade complete all as specified and directed. |
| 27 | Supplying, jointing and connecting in repairs cable end termination joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 240 sqmm to 300 Sqmm 3.5 core, 1100 volts grade complete all as specified and directed. |
| 28 | Supplying, jointing and connecting in repairs straight through joint, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 sqmm to 50 Sqmm 3.5 core, 1100 volts grade complete all as specified and directed. |
| 29 | Supplying, jointing and connecting in repairs straight through joint, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 70 sqmm to 120 Sqmm 3.5 core, 1100 volts grade complete all as specified and directed. |
| 30 | Supplying, jointing and connecting in repairs straight through joint,out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 150 sqmm to 185 Sqmm 3.5 core, 1100 volts grade complete all as specified and directed. |
| 31 | Supplying, jointing and connecting in repairs straight through joint, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 240 sqmm to 300 Sqmm 3.5 core, 1100 volts grade complete all as specified and directed. |
| 32 | Supply & laying in repairs 40 mm bore galvanised steel tubing, light grade, with all fittings, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with and including 02 Nos. MS clamp made of FI 25x4 mm, nuts, bolts and washers complete all as specified and directed. |
| 33 | Supply & laying in repairs 50 mm bore galvanised steel tubing, light grade, with all fittings, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with and including 02 Nos. MS clamp made of FI 25x4 mm, nuts, bolts and washers complete all as specified and directed. |
| 34 | Supply & laying in repairs 80 mm bore galvanised steel tubing, light grade, with all fittings, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with and including 02 Nos. MS clamp made of FI 25x4 mm, nuts, bolts and washers complete all as specified and directed. |
| 35 | S&F in repairs MCCB 4 Pole, 415 V, fixed type, 160 Amps rating with rupturing capacity 25 KA, as approved complete all as specified and directed. |
| 36 | S&F in repairs MCCB 4 Pole, 415 V, fixed type, 200 Amps rating with rupturing capacity 25 KA, as approved complete all as specified and directed. |
| 37 | S&F in repairs MCCB 4 Pole, 415 V, fixed type, 250 Amps rating with rupturing capacity 25 KA, as approved complete all as specified and directed. |
| 38 | S&F in repairs MCCB 4 Pole, 415 V, fixed type, 315 Amps rating with rupturing capacity 36 KA, as approved complete all as specified and directed. |
| 39 | S&F in repairs MCCB 4 Pole, 415 V, fixed type, 400 Amps rating with rupturing capacity 36 KA, as approved complete all as specified and directed. |
| 40 | S&F in repairs MCCB 4 Pole, 415 V, fixed type, 630 Amps rating with rupturing capacity 36 KA, as approved complete all as specified and directed. |
| 41 | Trimming up Bushes/ Tree branches upto 5 mtr all around security light poles & LT line, removing cut branches/ leaves from site complete all as specified and directed, Note :- (i) The overhead lines will be kept clear from all trees by trimming of tree branches with 5 mtr all around the line. (ii) Necessary permission shall be obtained by contractor from department one day prior to trimming and shut down in particular area will be arranged by department. (iii) Only effected Span where tree branches are touching nearly LT lines shall be measured. |
| 42 | M&L for detection of any type of fault in LT underground cable, laid in soil at plane area or forest area, with the help of Cable fault locator machine. Cable fault locator with carriyng vehicle and cable fault detection technician shall be provided by the contractor. Span of faulty cable shall be traced out by the technician by meggering LT cable. complete all as specified and directed. Note : (i) Detection of fault in one span of length will be measured as Each Job.(ii) Technicians will be employed by the working agencies. (iii) Excavation & Earth work shaill be measured and paid seperately.(iv) Replacement of cable & joints shall be measured and paid saperately.(v) Measurement & Payment shall be made only if the fault has been located & rectified. (vi) Recovery Rs. 2000/- par fault shall be made from contractors due in case the fault if not rectified with in 40 hours. |
| 43 | M&L in repairs for mild steel cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat & two coats of aluminium paint including dismantling from pole complete all as specified and directed. Please Enable Macros to View BoQ information |
| 44 | M&L in repairs for mild steel cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat & two coats of aluminium paint including dismantling from pole complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender