Tender For Shifting Of Main Lt Panel D Block & Ups Panel Kidney Block Alongwith Replacement Of 01 Nos. Acb In Old Lt Panel, A Block Including Rewiring With Replacement Of Electrical Fixtures In Lt Canteen,Nehru Hospital, Pgimer, Chandigarh
Tender Overview
Project Description
Tender for Shifting Of Main Lt Panel D Block & Ups Panel Kidney Block Alongwith Replacement Of 01 Nos. Acb In Old Lt Panel, A Block Including Rewiring With Replacement Of Electrical Fixtures In Lt Canteen,Nehru Hospital, Pgimer, Chandigarh
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 15-Oct-2026 | The item No. 30 of the BOQ may be read and considered | Technical Bid | 20-Oct-2026 |
| 2 | 15-Oct-2026 | Extended for more participation | Date | 20-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Part-A: Shifting of main LT panel D Block & UPS Panel Kidney Block |
| 2 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required |
| 3 | 3½ X 185 sq. mm |
| 4 | 3½ X 400 sq. mm |
| 5 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following sizes in masonry open duct as required. |
| 6 | Above 95 sq. mm and upto 185 sq. mm |
| 7 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 8 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25/3mm MS flat clamp) |
| 9 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 10 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. |
| 11 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25/3mm MS flat clamp) |
| 12 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 13 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 14 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 15 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 16 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 17 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 18 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 19 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 20 | Supplying and making end termination with brass compression gland and Aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE Aluminium conductor cable of 1.1 kV grade as required. |
| 21 | 3.5x50 sqmm (35mm) |
| 22 | 3.5x120 sqmm (45mm) |
| 23 | 3.5x185 sqmm (57mm) |
| 24 | 3.5x400 sqmm (82mm) |
| 25 | NS ITEMS |
| 26 | Removal of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. |
| 27 | Above 95 sq. mm and upto 185 sq. mm |
| 28 | LT Panel |
| 29 | Supplying installation, testing & commissioning of suitable size modular cubicle type LT panel, min. IP54, outdoor type with canopy structure on top, suitable for 415 V, 3Phase, 4 Wire 50 Hz AC supply , compartmentalized made from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates, complete with 7 tank process for powder coating in approved shade, Panel shall be minimum Form 3B. Panel shall be Tested for IK 10, Internal Arc protection and Fault Level of Minimum 50 A for 1 sec as per IS/IEC 61439. Panel Busbar rating shall be as per test report of OEM as per IS/IEC 61439 ( same shall be verified on drawings and during inspection). All switchgear used shall have Fault level Ics =Icw=100 %Ics . |
| 30 | Panel should be designed such that it has a curved MS shed at top for external use. Cable entry from botton after construction of suitable base. Bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 2.5 sq. mm. PVC insulated copper conductor cable, providing with following switch gears :- |
| 31 | Incomer 1&2 |
| 32 | MCCB FP 630A, 36KA, Microprocessor based with O/L S/C protection - 2 Nos. |
| 33 | Spreader set |
| 34 | Extended rotary handle |
| 35 | Undervoltage release |
| 36 | Mechanical lock |
| 37 | Digital ammeter with ASS |
| 38 | Digital voltmeter with VSS |
| 39 | R,Y Phase indicating lamp 240V AC |
| 40 | B Phase indicating lamp 240V AC |
| 41 | 6A. SP Control MCB |
| 42 | CT`s 630/5A. CL-1 15VA Resin cast/nylon casing |
| 43 | CT Shorting link |
| 44 | Neutral link |
| 45 | BUS COUPLER |
| 46 | MCCB FP 400A, 36KA, Microprocessor based with O/L & S/C Protection - 1 Nos |
| 47 | Spreader set |
| 48 | Extended rotary handle |
| 49 | Mechanical Interlock |
| 50 | OUTGOING SECTION -1 |
| 51 | For MS LV1 LEFT SIDE TO MS LV5 LEFT SIDE |
| 52 | MCCB TP 250A, 36KA, Thermomagetic based With O/L, & S/C Protection - 5Nos. |
| 53 | Spreader set |
| 54 | Extended rotary handle |
| 55 | For VTPN1, VTPN2 PROCUREMENT BRANCH |
| 56 | MCCB TP 200A, 36KA, Thermomagetic based With O/L, & S/C Protection - 2Nos. |
| 57 | Spreader set |
| 58 | Extended rotary handle |
| 59 | For VTPN3 CNO OFFICE SIDE |
| 60 | MCCB TP 160A, 36KA, Thermomagetic based With O/L, & S/C Protection - 1 Nos. |
| 61 | Spreader set |
| 62 | Extended rotary handle |
| 63 | MCCB 125A |
| 64 | MCCB TP 125A, 36KA, Thermomagetic based With O/L, & S/C Protection - 2 Nos. |
| 65 | Spreader set |
| 66 | Extended rotary handle |
| 67 | OUTGOING SECTION -2 |
| 68 | For DATA CENTER |
| 69 | MCCB TP 400A, 36KA. Microprocessor based with O/L & S/C Protection - 1 Nos. |
| 70 | Spreader set |
| 71 | Extended rotary handle |
| 72 | MS LV1 RIGHT SIDE TO MS LV5 RIGHT SIDE |
| 73 | MCCB TP 250A, 36KA, Thermomagetic based With O/L, & S/C Protection - 5 Nos. |
| 74 | Spreader set |
| 75 | Extended rotary handle |
| 76 | PVT GRANT CELL |
| 77 | MCCB TP 160A, 36KA, Thermomagetic based With O/L, & S/C Protection - 1 Nos. |
| 78 | Spreader set |
| 79 | Extended rotary handle |
| 80 | AHU PANEL SUPPLY |
| 81 | MCCB TP 160A, 36KA, Thermomagetic based With O/L, & S/C Protection - 1 Nos. |
| 82 | Spreader set |
| 83 | Extended rotary handle |
| 84 | MCCB 125A. |
| 85 | MCCB TP 125A, 36KA, Thermomagetic based With O/L, & S/C Protection - 2 Nos. |
| 86 | Spreader set |
| 87 | Extended rotary handle |
| 88 | ENCLOSURE & ACCESSORIES |
| 89 | FABRICATION IN 2.0/1.6MM CRCA SHEET POWDER COATING IN SIEMENS GRAY SHADE, CABLE ENTRY WILL BE TOP & BOTTOM SUITABLE FOR CABLE,LOCK, RUBBER GASKET, HARDWARE ETC. |
| 90 | BUS BAR & HARDWARE |
| 91 | 600A. TPN ALUMIMIUM MAIN BUS BAR,LOAD WISE SUB FEEDER BUS BAR COLOUR COATED HEAT SHRINK BUS BAR SLEAVE NUT-BOLT,WASHER,HARDWARE ETC. |
| 92 | WIRING & ACCESSORIES |
| 93 | POWER & CONTROL WIRING WILL BE (ISI 1100V) FLAME RETARDENT LOW SMOKE PVC SINGLE CORE COPPER WIRE,COPPER LUGGS, PVC SLEEVE, FERRULES, NUMBERS, HARDWARE & LABOUR ETC. |
| 94 | Shifting and reinstallation of UPS changeover assembly from existing UPS room to appropriate location after opening connections and mounting on a wall surface after drilling and fixing with bolts/fastners etc as required and providing earthing connection with full satisfaction of Engineer in charge. Testing and commsioning of this assembly after connecting cables needs to be done before handover to EIC. |
| 95 | Supply of copper conductor XLPE insulated armoured and served cable to be laid as per requirement at the site of work including all petty material required to complete the job. upto entire satisfaction of the Engineer-in-charge. |
| 96 | 50sqmm , 3.5 core cable |
| 97 | 120 sqmm, 3.5 core cable |
| 98 | 185 sqmm, 3.5 core cable |
| 99 | 400 sqmm, 3.5 core cable |
| 100 | Part-B: Replacement of 01 Nos. ACB in old LT Panel, A Block |
| 101 | Supply,installation in existing panel, testing and commissioning of 800A , EDO type, MP based ACB having Icu=Ics=Icw(1sec)= 50KA and conforming to IS/IEC 60947-2&3 standard. Job inludes installation and fabrication if any, in existing LT panel with all materials and spares required with full satisfaction of Engineer in charge. |
| 102 | 800A 4P ACB having Mircroprocessor based releases for O/L, S/C & E/F. SITC of Indicator RYB, On,Off,trip, current transformer, CT shorting Terminals, MCB , Neutral Link, Auxiliary Contractor, Terminal Blocks, Wiring for feeder, Busbar Link for ,etc as required at site. |
| 103 | ACB shall have one set of the following items: |
| 104 | Intelligent multi function digital meter Datalog (8 MB),Analog I/O, digital I/O variants available, Meter with Ethernet port available Parameters: V, A, F, kW, KVA, kVAr, kWh, kVAh, kVArh, PF, Runhr, Onhr, Interupts,Phase angle, THD, Neutral current, Max Demand (with RTC), Events (high-low) with time stamp,Individual Harmonics upto 31st. |
| 105 | 1 Set Indication Lamps, LED type, for RYB with2 Amp control MCB.& breaker 'ON', 'OFF', 'TRIP' & spring charged lamps with 2 Amp MCB for controlling alonwith SITC of TNC switch. |
| 106 | De-termination and dismantling of following material from existing panel including transportation from PGI for rebate |
| 107 | Old ACB |
| 108 | Part-C: Rewiring with replacement of electrical fixtures in LT canteen,Nehru Hospital |
| 109 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 110 | Group C |
| 111 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 112 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface / recessed steel / PVC conduit as required. |
| 113 | 3x1.5mm2 |
| 114 | 3x4mm2 |
| 115 | Supplying and fixing following size / modules, GI box along with modular base and cover plate for modular switches in recess etc. as reqd. |
| 116 | 6 module(200mmx75mm) |
| 117 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 118 | 5/6 A switch |
| 119 | 15/16 A switch |
| 120 | 3 pin 5/6 A socket outlet |
| 121 | 6 pin 15/16 A socket outlet |
| 122 | Supplying and fixing following way, horizontal type three phase and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 123 | 6 way (4 + 18), Double door |
| 124 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 125 | Single pole |
| 126 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 127 | Extra for fixing the alumiium louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 128 | Supplying, installation,testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 3 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. |
| 129 | Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/square/ Rectangular) COB type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. |
| 130 | 18 watt |
| 131 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 132 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 133 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size oncable tray as required. |
| 134 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 135 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 136 | 4 X 16 sq. mm (28mm) |
| 137 | Supply of 380 mm Exhaust Fan heavy duty 900 rpm inlcuding Al louvers and all accessories to complete the job making the connections etc as require at site upto the complete satisfaction of Engineer Incharge. |
| 138 | Supply Installation, testing and commissioning of Led fixture 1200mmX300mm (approx) 36W Surface Mounted Led luminaire having minimum system lumen efficacy of 120lm/W with P.F.>0.95 with THD<10% ,CRI>80,CCT = 5700K, efficency of driver >85% and shall have under voltage and over voltage protection, Glare index shall be <23 complete with all accessories, and mounting of light in ceiling as per the satisafaction of the Engineer Incharge. |
| 139 | Supply of copper conductor XLPE insulated armoured and served cable to be laid as per requirement at the site of work including all petty material required to complete the job. upto entire satisfaction of the Engineer-in-charge. |
| 140 | 16 sqmm, 4 core cable |
| 141 | Supplying and fixing following rating, TPN, 415 volts,MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 142 | 63 amps TPN |
| 143 | Dismentling of existing light fixtures, switch/sockets, celing fans, light point etc complete in all respect. |
| 144 | Rebate of the old Dismentled material i.e. Old Panel, old light fixtures, wiring points, switch sockets, etc complete in all respect including removal of the same prom PGI premises.The serviceable material like MCCBs, lights/Ceiling fan shall be retained by the department. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender