Tender For Erection Of 220/132 Kv 200 Mva Transformer And Associated Work At 220 Kv Gss Pali Distt. Jodhpur On Labour Contract Basis
Tender Value
5.26 Lakhs
Estimated cost
Bid Submission
12 Oct 2026
5 days left
EMD
10540
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pali → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Erection Of 220/132 Kv 200 Mva Transformer And Associated Work At 220 Kv Gss Pali Distt. Jodhpur On Labour Contract Basis
BOQ
| Sl. No. | Item Description |
| 1 | EARTH MESH WORK |
| 2 | Laying of earth mesh with 25mm/28mm dia ,M.S. Rod at depth Of 0.80 metre from top of foundation including excavation of trench of required depth and backfiling of the same transportation of M.S.Rods from site store to locations, welding of M.S.Rod along the length, at crossings and with earth electrodes as per drawing application of bitumen compound and covering with bitumen impregnated tape on all welded joints, for the type of soil prevalent at 0.80 metre below top level of foundations (M.S.Rod of above sizes & M.S.Flat required shall be made available by RVPN) |
| 3 | a) In case electricity is made available by RVPN without charges |
| 4 | i) Any soil,soft rock other than hard rock |
| 5 | Laying of earthing risers of 50x6mm/50x10mm/50x12mm size M.S.Flat at a depth of 0.80 metre from top level of foundations, including excavation of trench of required depth and backfilling of the same, transportation of M.S.Flat from site store to location preparation of risers, bending as per requirement (after heating if necessary), fixing on and welding/bolting to equipment/ structure abd oeajs if structures, laying in the trench, welding to the earth mesh of M.S. Rod as per drawing including welding of extra length of M.S.Flat if required, application of bitumen compound and covering with bitumen impregnated tape on all welded joints,painting of all surface of risers above ground level with red oxide and green paint, for the type of soil prevalent at 0.80 metre below top level of foundations (M.S.Rod of above sizes & M.S .Flat as required shall be made available by RVPN) |
| 6 | (a) In case electricity is made available by RVPN without charges. |
| 7 | i) Any soil,soft rock other than hard rock |
| 8 | Placing/Driving of earth electrode of 25/28mm dia M.S.Rod of length 3.30 meters (approx) to a depth of 3.80 meters from the top level of foundation including excavation of pit as required and back filling of the same, transportation of M.S.Rod from site store to locations, cutting of M.S.Rod to desired length preparation of one end as spike if necessary,welding of earth electrode to earth mesh of M.S. Rod as per drawing, application of bitumen compound and covering with bitumen impregnated tape on all welded joints for the type of soil prevalent at 3.80 meters below top level foundations (M.S.Rod of above sizes & M.S.Flat as required shall be made available by RVPN) |
| 9 | (a) In case electricity is made available by RVPN without charges. |
| 10 | i) Any soil,soft rock other than hard rock |
| 11 | BUS-BAR WORK: |
| 12 | STRINGING of 220KV, 132KV, 33KV & 11KV Bus Bar of ACSR Conductor, including transportation of conductor,disc insulator and tension hardware from site stores to location, laying and cutting required length of conductor, cleaning and assembly of disc insulators as required along with fitting of bolted type or compression tape tension hardware as made available, making up at one end, stringing of conductor between the beam with specific sag and tension, also equalizing sag and fitting spacers and spacer T-clamps for twin conductor, for three phase of conductor in each bus-section. |
| 13 | ii) Any Double Conductor |
| 14 | JUMPERS OF ACSR conductor ( 3 nos Y- type) between bus to equipment or between equipment to equipment or between bus to bus, including transportation of conductor, disc insulators and hardware from site stores to locations, cleaning and assembly of disc insulators as required along with fitting of suspension hardware and erection as required, cutting required length of conductor making connections, fixing of spacers & spacer T-clamps as required, tightening of clamps / connectors, dressing etc, for three phases (Per jumper basis). |
| 15 | i) Any Conductor |
| 16 | Erection of Current Transformer / Potential Transformer / Capactive Voltage Transformer / Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation fro site store to location, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc. complete in all respect. |
| 17 | i) 220 KV CT / PT / CVT |
| 18 | ii) 132 KV CT / PT / CVT |
| 19 | Erection of 220 KV or 132 KV Circuit Breakers, including transportation of equipment, structure members, nuts & bolts, clamps & connectors, accessories etc. from site store to location, assembly of support structure, their placing on foundation, levelling and preparing for grouting as required, but excluding grouting. assembly / placing of support colums / poles, mechanism box / control cubicle and other accessories as per manufacturer’s drawings, fitting of SF-6 gas pipeline, fabrication of air / oil pipeline as required, electrical wiring from pole to control cubicle, fixing of terminal connectors as required, but excluding commissioning of CB, for all types of operating mechanism, as required. |
| 20 | i) 220 KV |
| 21 | Erection of 220 KV Class EHV Transformer (Gas filled tank already placed on foundation with wheels), including transportation of accessories from site store to locations, erection of HV, IV, LV & Neutral bushings, erection of cooler bank with associated pipe line, radiators, fans, pump, main & OLTC conservators, equalizing pipe line, marshalling kiosk, etc. as per manufacturer's drawing, preparation of oil, oil filling, dehydration of transformer along with cooler bank & diverter switch (filter machine, oil tank & operating staff shall be provided by RVPN), electrical wiring from individual equipment, e.g., Buchholz relay, MOLG, OSR, Fans, Pumps, Bushing C'T's etc. to marshalling kiosk, etc., but excluding testing & comrnissioninq of transformer |
| 22 | a) If electricity is available & arranged by RVPN without charges. |
| 23 | Erection of Control & Relay Panels complete in all respect including transportation from site store to control room, placing on foundation / cable trench as per layout, interconnection between Control & Relay panels and with existing panels fixing of site / top covers and doors earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control room and relay panel as required. |
| 24 | ii) Duplex Panel |
| 25 | iii) Simplex Panel, DC Panel,RTCC Panel,PLCC Panel,etc. |
| 26 | LAYING AND TERMINATION OF CABLES |
| 27 | Control Cable: |
| 28 | i) Laying of P.V.C insulated unarmoured / armoured control cable of 1.1 KV grade with copper conductor in cable trenches as per specification as required, including transportation of cable drums from site store to locations, laying in cable trenches, cutting to required length, placing them on cable racks / cable trays / cable batten & dressing, including removing and re-fixing trench covers as required making necessary connections, testing, cable marking on both the terminating ends, etc. as required for all sizes from 2c x 2.5 sq.mm to 20c x 2.5 sq.mm, 4c x 4 sq.mm and 4c x 6 sq.mm. a) Unarmoured control cable. |
| 29 | b) armoured control cable. |
| 30 | ii) Fixing of control cables in position with single compression nickel plated brass cable glands confirming to IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates, etc. as required, & including cost of cable glands, for each cable gland of size.a) 19 mm unarmoured control cable |
| 31 | b) 19 mm armoured control cable |
| 32 | c) 25 mm unarmoured control cable |
| 33 | d) 25 mm armoured control cable |
| 34 | e) 32mm unarmoured control cable |
| 35 | f) 32mm armoured control cable |
| 36 | iii) Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type as required of Dowell’s or equivalent make as approved by the Engineer-in-Charge duly crimped with crimping tool, including making wire ends ready for crimping, ferruling & dressing of wires etc. as required, including cost of terminal ends for all wires, for each cable at both ends for cables of the following sizes. |
| 37 | a) 2.5 Sq.mm for any number of core |
| 38 | b) 4 Sq.mm for any number of core |
| 39 | Dismantling |
| 40 | Dismantling of Jumpers any conductor |
| 41 | Dismantling of 132 kV CT |
| 42 | Dismantling of 220/100 MVA TRF |
| 43 | Dismantling of C&R Panel Duplex |
| 44 | Dismantling of C&R Panel Simplex |
| 45 | Shifting of 220/132 kV, 100 MVA Transformer (Foundation to Yard) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysOct 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender