Tender For Provn Of External Electricity Supply Connection For Various Engr Op Wks Shelter ; Chequred/Interlocking Tiles Track With Cgi Sheet Covering Pathway With Iron Frame Near From T-197 To T-191 & T-188 To T-189 (Approx 90 Mtr),(Jco Mess To Cook
Tender Overview
Project Description
Tender for Provn Of External Electricity Supply Connection For Various Engr Op Wks Shelter ; Chequred/Interlocking Tiles Track With Cgi Sheet Covering Pathway With Iron Frame Near From T-197 To T-191 & T-188 To T-189 (Approx 90 Mtr),(Jco Mess To Cook House) ;Toilet Block Behind Dsls;Septic Tank & Soakage Well Near Bde Mt At Along Mil Stn Under Ge 872 Ews
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-Oct-2026 | BOQ Corrigendum | Other | 26-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Surface dressing not exc. 150mm deep and getting out in Soft/Loose Soil, complete all as specified and as directed. |
| 2 | Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 3 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, trenches for shafts, wells, cesspits, manholes, pier holes, cable etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 4 | Excavating over areas, n exc 1.5 m deep and getting out as in Soft/Loose Soil, complete all as specified and as directed. |
| 5 | Excavating over areas, exc 1.5 m deep but n exc. 3.00 and getting out as in Soft/Loose Soil, complete all as specified and as directed. |
| 6 | Excavating over areas, exc 3.0 m deep but n exc. 4.50 and getting out as in Soft/Loose Soil, complete all as specified and as directed. |
| 7 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed. |
| 8 | Excavating in post holes (or similar holes) each n. exc. 0.5 cum, getting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc. 25 cm watering and removing surplus soil to distance n. exc 50 m and making good surface complete all as specified and directed. |
| 9 | Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 10 | Earth Filling under floors or in foundation including watering and consolidation well ramming including spreading and levelling n. exc 25 cm thick complete all as specified & directed. |
| 11 | M & L for broken brick , Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface all as specified & directed. |
| 12 | M & L for Sand filling under floors or in foundations including spreading, levelling, watering and consolidation complete all as specified and directed. |
| 13 | M & L for Pre-cast cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate), block masonry with solid blocks of size 300x200x200mm or 300x200x100mm, having compressive strength of not less than 100 Kg/Sq Cm (As per IS-2185) exc. 10 cm in width and setting in mortar 1:6 complete all as specified and directed. |
| 14 | M & L for Providing Pre-cast cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed) setting in mortar, complete, in walls in width and setting in mortar 1:6 complete all as specified and directed. |
| 15 | M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed. |
| 16 | M&L Plain Cement Concrete type C2 (1:3:6), using 40mm graded crushed stone aggregate as in foundation of man holes complete all as specified and as directed. |
| 17 | M & L for precast cement concrete (1:2:4) type B1 (using 12.5mm graded stone aggregate) setting in CM 1:6 work for in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces,complete all as specified and as directed. |
| 18 | M&L for Plain cement concrete 1:2:4, type B-1, (using 20 mm graded stone aggregate) as in benching, coping and brick steps including necessary form work complete all as specified and directed. |
| 19 | M&L for 40mm thick damp proff course to horizontal or vertical surfaces in cement concrete 1:2:4, type B-0 using 12.5mm graded stone aggregate complete all as specified and directed. |
| 20 | M&L Reinforced Cement Concrete (Design Mix) M-25 in Foundations including Rafts, Footings, Foundation Beams; Plinth Beams; bases for Columns, etc.; Basement Slabs, Under-reamed Piles and Mass Concrete, complete all as specified and as directed. |
| 21 | M&L Reinforced Cement Concrete (Design Mix) M-25 in Columns, Pillars, Piers, Posts and Struts, etc. complete all as specified and as directed. |
| 22 | M&L Reinforced Cement Concrete (Design Mix) M-25 in Roof Beams, Cantilevers, Bres-summers, Lintels over 1.50 Metre Span, complete all as specified and as directed. |
| 23 | M&L Reinforced Cement Concrete (Design Mix) M-25 in Chajja etc., complete all as specified and as directed. |
| 24 | M & L Reinforced Cement Concrete 1:2:4, Type B-1 (Nominal Mix) (using 20 mm graded stone aggregate) for columns ,pillars ,Piers ,posts and struts complete all as specified and directed.(Note : Reinforcement will be measured & paid seperately) |
| 25 | M & L Reinforced Cement Concrete 1:2:4, Type B-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in beams, cantilevers, lintels over 1.5m span complete all as specified and directed.(Note : Reinforcement will be measured & paid seperately) |
| 26 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter all as specified & directed |
| 27 | M&L Use and waste for Formwork to Sides and Soffits of Floor or Roof Beams, Beam Haunchings, Girders, Bres-Summers, Lintels, Cantilevers, Shelves including supports, overhangs, etc. also splays between floors and beams, etc., flat, rough finished surfaces of concrete, complete all as specified and as directed. |
| 28 | M&L Use and waste of Formwork to sides of Pillars, Posts, Struts, Piers, Columns and stanchions, flat, rough finished surfaces of concrete, ( complete all as specified and as directed. |
| 29 | M&L Formwork to Soffits of suspended slab such as Roof slab, Floor slab, landings and similar works horizontal or sloping etc., not exceding 200mm thick ,flat rough finished surfaces of concrete, complete all as specified and as directed. |
| 30 | M & L for Formwork to chullah hoods, chajjas, troughs and similar items including edges,complete all as specified & directed. |
| 31 | S&F powder coating (minimum thickness of powder coating 50 micron)aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and as directed. |
| 32 | S&F powder coated Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed .Note:- Fixing of wire mesh and glass shall be measure and paid separately under relevant items. |
| 33 | S & F solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed. |
| 34 | S & F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded, plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, as per specification and drawing and as directed. |
| 35 | S & F 75 mm long, mild steel butt hinges fixed with stainless steel hinge pin etc complete all as specified and directed. |
| 36 | S & F 150 mm long, Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 37 | S & F 150 mm size, extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 38 | S & F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed. |
| 39 | S & F Pre-Painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/vally gutter, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed. |
| 40 | M&L Mild Steel Work in Tubular Trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conform-ing to IS:1161-1979 grade St.-240, complete all as specified and as directed. |
| 41 | M & L for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165, complete all as s[ecified & directed. |
| 42 | S&F Rolled mild steel as in Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. and fixing complete Fe 290 Gde-E-165 quality-A complete all as specified and directed. |
| 43 | S&F Mild Steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment (Fe-290 Gde-E165) complete all as specified and directed. |
| 44 | M&L for TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (anealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 45 | S & F high strength Mild steel TMT bars 5mm dia and over upto and including 10mm dia in strirrups, spacers and binders spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed. |
| 46 | M & L for 25 mm thick, plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in flooring, etc and finished the surface even and smooth without using extra cement complete all as specified and directed. |
| 47 | M & L for 100 mm thick, plain cement concrete 1:4:8, type D-2(using 40 mm graded stone aggregate) as in sub base under floor complete all as specified and directed. |
| 48 | M & L for 75 mm thick, plain cement concrete 1:4:8, type D-2(using 40 mm graded stone aggregate) as in sub base under floor complete all as specified and directed. |
| 49 | M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed. |
| 50 | M&L cement concrete chequered tiles of size 300 x 300 x 20 to 25 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match including 20mm thick screed bed in cement mortar 1:6 for laying floor finishes and including dismantling of chequered tiles . complete all as specified and directed. |
| 51 | M&L Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade , complete all as specified and as directed. |
| 52 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc, and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed. |
| 53 | M&L Glazed Ceramic Coloured Tile 450 x 350 x 7.0mm thick on Vertical Surfaces such as Skirting, Dados, Risers to Steps, etc., Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over and including 10mm thick backing layer in cement mortar (1:4) complete all as specified and as directed. |
| 54 | M&L Rendering 10 mm thick in Cement Mortar 1:6 on Brick Walls or on Concrete Surfaces, finishing plastered surfaces Even and smooth without using extra cement complete all as specified and as directed. |
| 55 | M&L 15 mm thick rendering in cement mortar (1:4) on fair faces of brick or concrete external surfaces in two layers (10mm+5mm thick) finished even and smooth without using extra cement using water proofing compound on top layer @2% by weight of cement or as per manufactures instruction on external wall surface upto height of 4th storied bldg complete all as specified and directed.Note : WPC shall be measured and paid seperately |
| 56 | M&L Rendering 15mm thick in Cement Mortar 1:4 on other than fair faces of Brick Walls or on Concrete Surfaces, finishing plastered surfaces Even and Smooth without using Extra Cement complete all as specified and as directed. |
| 57 | Nerrufinish to plastering as specified & directed. |
| 58 | Supply only integral water proofing compound (ISI marked) complete all as specified and directed. |
| 59 | M & L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 60 | M & L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and directed. |
| 61 | M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed. |
| 62 | S & F 15 mm bore, Stop/angle valves, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 63 | S & F 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed. |
| 64 | S & F 15mm bore, bib taps, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule fixed in repair complete all as specified and directed. |
| 65 | S & F Soap dish, Vitreous china white, approximate size 160mm x 160mm x 90mm, embedded in walls/fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 66 | S&F Rotational Moulded Polyethylene (HDPE) Water Storage Tank 1000 Litre Capacity (Cylindrical Vertical with Closed Top), Black in Colour, Three Layered Construction, hoisted and fixed in Position all specified in MES Schedule Part-I including provision of 25mm x 100mm GI nippples with check nuts for inlet, outlet wash and overflow pipe including 20 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe complete all as specified and as directed. |
| 67 | Supply and fix in repairs Vitreous China squatting pan of ‘Orissa pattern’, size 580 mm x 440mm (white) with ‘P’ or ‘S’ trap, front or back inlet and foot rests, any pattern complete including provision of PCC bedding and connection to trap, and to flushing pipe, antisyphonage pipe, etc. complete including making good to floor all as specified and directed. |
| 68 | S&F PVC connection 15mm size with PTMT nut of length 450mm complete all as specified and directed. |
| 69 | Supply and fixing 10 litre capacity low level PVC flushing cistern (any colour), syphonic action type, with inlet, ball valve, float, handle, fixed with cast iron bracket (of suitable size) and providing 32 mm dia PVC flush pipe and making all necessary connections complete as directed. |
| 70 | S & F in repair 20 mm bore, gun metal Gate valves, with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed. |
| 71 | S&F Brass chromium plated tubular towel rail, 20mm dia, D type, 60,cm long between flanges as in repair complete all as specified and directed. |
| 72 | S & F 600mmX450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plug with chromiun plated brass screws and cup washers complete all as specified and directed. |
| 73 | S & F steel tubing of 15 mm bore medium grade including fittings fixed to wall/ Ceiling laid in floors etc complete complete all as specified & directed. |
| 74 | S & F steel tubing of 20 mm bore medium grade including fittings fixed to wall/ Ceiling laid in floors etc complete and including taking down old steel tubing & connection complete all as specified & directed. |
| 75 | S & F 75 mm bore, PVC (SWR), Soil, waste and vent pipes, single socketed in any length with rubber ring joints fixed to walls, etc complete all as specified and directed. |
| 76 | S&F PVC (SWR) Soil, Waste and Ventilating Pipe 110mm bore (dia), single socketed, in any length with Rubber Ring Joints fixed to Walls or in any position complete all as specified and as directed. |
| 77 | S & F 110 mm bore, PVC (SWR), Soil, waste and vent pipes, single socketed in any length with rubber ring joints laid in trenches , etc complete all as specified and directed. |
| 78 | S & F 75 mm bore, PVC (SWR), Soil, waste and vent pipes, single socketed in any length with rubber ring joints laid in trenches , etc complete all as specified and directed. |
| 79 | M&L for Concrete bed Type C-2 (1:3:6) (Using 40mm graded crushed stone aggregate) to 110 mm bore PVC (SWR) pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed |
| 80 | S & F 150 mm bore, PVC (SWR), Soil, waste and vent pipes, single socketed in any length with rubber ring joints laid in trenches , etc complete all as specified and directed. |
| 81 | M&L for Concrete bed Type C-2 (1:3:6) (Using 40mm graded crushed stone aggregate) to 150 mm bore PVC (SWR) pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed |
| 82 | S & F 75 mm bore, PVC (SWR) bends of any radius complete all as specified and directed. |
| 83 | S & F 110 mm bore, PVC (SWR) bends of any radius complete all as specified and directed. |
| 84 | S & F 75mm bore, PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 85 | S & F 110mm bore, PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 86 | S & F 75 mm bore, PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed. |
| 87 | S & F PVC (SWR) 75 mm bore (dia) vent cowl , complete all as specified & directed. |
| 88 | S & F PVC (SWR) 100 mm bore (dia) vent cowl , complete all as specified & directed. |
| 89 | S&F Vitreous China Wash Hand Basin 600x480mm in size, White (Flat Back )including cutting for and pinning in , including 32 mm waste pipe and CP Waste coupling etc. complete all as specified and as directed. |
| 90 | S&F Vitreous China Wash Hand Basin 450 x 300mm in size, White (Flat Back )including brackets and pedestal cutting for and pinning in , including 32 mm waste pipe and CP Waste coupling etc. complete all as specified and as directed. |
| 91 | M & L for Point wiring for one light/exhaust fan/ceiling fan point/call bell controlled by one way switch with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC casing capping (ISI marked) (aprox size 20/25/40mm width) surface type with all fittings/fixtures such as Tee, Bend, elbow, socketr, shaddle etc including 1.5mm thick MS sunken/terminal box including 3mm thick backelite sheet cover for fixing flush type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed.(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.) |
| 92 | S & F Modular switch one way 6 Amp 240 volts, 1 module ,240 volt AC and connecting up ,complete all as specified and as directed. |
| 93 | S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed. |
| 94 | S & F LED Bulb 7 watt complete all as specified & directed. |
| 95 | S & F Angle Holder , PVC /polycarbonate type with backplate including LED Bulb , 15 watts , B-22 Lumen ≥ 900, Luminous afficancy ≥ Lum/watt, CCT: WW/NW/CW, CRI > 80 Ra , IP20 rated ,overmounted plastic housing, polycarbonate diffuser , 4 KV surge protection with over Voltage protection withstand upto 440 V (for 10 minute) with open and short circut protections as per IS :16102 complete all as specified & directed. |
| 96 | S & F LED tube light fittings, retro bar professional WH 5700K to 6000K, 20 Watt and 2000 Lumens of cool white with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. |
| 97 | S & F LED Bulk Head, 10 Watt, IP 65 rated, compact design, PC Co extruded with high energy saving with all accessories and connecting up including lamp complete all as specified and directed. |
| 98 | S & F sheet metal enclosure for DB's when MCBs to be used 4-way, SPN 4 Way, 240V, Double door with IP 43 protection epoxy based powder coated suitable for mounting MCB DP/SPN as incomer and MCB SP as out -goings with 200 amps rated Bus-bar , neutral Bar, earth bar, connecting cable links and connecting up , including taking down unserviceable sheet metal enclosure of any description ,complete all as specified and as directed. |
| 99 | S & F MCB SPN 32A Amps, 240 Volts, 10KA, C Curve complete all as specified and as directed |
| 100 | S & F MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed |
| 101 | Supply & fixing /Laying Galvanised steel water tubing (medium grade) ,ISI marked with all new GI fittings and fixed to wall and ceilings or laid in floors etc. of size 25 mm dia , complete all as specified & directed. |
| 102 | Supply & fixing /Laying Galvanised steel water tubing (medium grade) ,ISI marked with all new GI fittings laid in trenches etc. of size 40 mm dia , complete all as specified & directed. |
| 103 | Supply & fixing /Laying Galvanised steel water tubing (medium grade) ,ISI marked with all new GI fittings laid in trenches etc. of size 25 mm dia , complete all as specified & directed. |
| 104 | Supply and fix in repair Gun metal, globe or gate valves (ISI marked) ( Class-I) with iron wheel head, screwed both ends for 25 mm bore GI pipe including taking down old unserviceable one complete as specified and as directed |
| 105 | S & F Ball Brass valves,high pressure with polythene float anf fly nut complete for brass ferrule of size 25 mm bore dia ,complete all as specified & directed. |
| 106 | Materials and Labour Cutting existing road / path etc by manual ,depth width not less than 30 cm for pipes upto 50 mm dia and filling back with excavated soil upto 75% road pertion and 25% shall be made with cement concrete C2 ( 1:2:4,) using 20mm graded crushed stone aggregates) of suitable depth complete all as specified & directed. |
| 107 | Materials and Labour Cutting existing road / path etc by manual ,above 50 mm upto 100 mm dia bore ,depth and width not less than1 meter for pipes below Ground level and filling back with excavated soil upto 75% road pertion and 25% shall be made with cement concrete C2 ( 1:2:4,) using 20mm graded crushed stone aggregates) of suitable depth complete all as specified & directed. |
| 108 | Materials and Labour Cutting existing PPR/Steel tubing for alterations or additionsif necessary done , in any position without taking down of size upto 50 mm dia bore , complete all as specified & directed. |
| 109 | M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab of size 350x350x50mm (reinforced with 10 mm dia TMT bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed. |
| 110 | Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately) |
| 111 | Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 4 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately) |
| 112 | Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 2 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately) |
| 113 | Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately) |
| 114 | Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 4 Sqmm 2 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately) |
| 115 | Supply & laying of GI tubing light grade of size 25 mm dia bore in protection of cable at road crossing/hard standing/pole protection fixed with clamps as per site requirement etc. all as pecified and directed. |
| 116 | Supply & laying of GI tubing light grade of size 50 mm dia bore in protection of cable at road crossing/hard standing/pole protection fixed with clamps as per site requirement etc. all as pecified and directed. |
| 117 | Supply and laying dry coarse sand as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified and as directed.Note:- Thickness after punning down shall be measured for payment. |
| 118 | Supply and laying locally available best quality, well burnt sub class B bricks (old size), laid dry in trenches for protection of UG cables complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 8 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender