Defence Government Departments Closing in 7 days TDR #57844624

Tender For Supply Installation Testing and Commissioning of Security Lights And Pole Near Ftr Generator Room To Rpao Office At Bsf C Us Umpling Under Ftr Hq Bsf Meghalaya

Issued by Government Departments · East Khasi Hills, Meghalaya
Tender Value
19.92 Lakhs
Estimated cost
Bid Submission
12 Oct 2026
7 days left
EMD
39847
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
East Khasi Hills → Meghalaya
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of Security Lights And Pole Near Ftr Generator Room To Rpao Office At Bsf C Us Umpling Under Ftr Hq Bsf Meghalaya

BOQ

Name of Work:- SITC OF SECURITY LIGHTS AND POLE NEAR FTR GENERATOR ROOM TO RPAO OFFICE AT BSF C US UMPLING UNDER FTR HQ BSF MEGHALAYA
Sl. No. Item Description
1Supplying and erection of 7 Mtrs long continously tapered octagonal pole (bolt fixing type) in single section with single longitudinal weld & galvanized having top dia 70MM as per following specification:- Make Bajaj/Nezone/Crompton/Jintal/Tata/Utkarsh a) Top dia - 70mm b) Bottom dia - 130 mm c) Thickness of sheet - 3mm d) Base plate size - 220mm X 220 mm X 12mm e) The pole shall be complete with following :- Set of foundation bolts -4 nos, 20mm dia, 600 mm in length complete with anchor plate. The foundation bolt shall be hot dipped galvanised. f) Integral junction box duly hot dipped galvanised complete with door and locking arrangement as required.
2Supplying and fixing of 4 Pole,3 phase 63 Amp heavy duty connector bolt type with bakelite sheet MCB din rail in the existing junction box of the octagonal pole (as per item No 1) etc as required
3Providing and erection of channeled shaped Flood Lighting Bracket of required size (To be appoved by Engg-in-charge) suitable for mounting of flood lighting luminaire on polygone (8 sides) cross section, octagonal type, 7 Meter height pole with 04 Nos 18 mm dia symmetrically located holes / slots including providing and fixing matching G.I nuts-bolts and washers required for fixing the bracket on the pole as per specifications.
4Supplying,Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 Hz,Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (A) 100 WATT
5S/L of 3 Core cable 1.5 sqmm size of PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to IS 694 : 2010 from looping box to light fitting including interconnection with connector,testing complete etc as required
6S.I.T.C of feeder pillar , outdoor type, dust and vermin proof made out of 2 mm thick CRCA sheet of nominal size 0.9 mt. x 0.75 mt X450 deep, front and back openable- hinged type door, duly eposy based pwder coated (from inside and outside), and fixed on M S angle iron frame work of size 40 mmx 40 mmx 6 mm length with 4 nos. 750 mm long legs duly welded to the frame structure and out of which 300 mm will be grouted in 1:2: 4 cement concrete foundation i/c supply and fixing of following accessores, connection and interconnection, inter locking wiring, thimbling, numbering-ferrules up & lowering system, earthing stud etc. complete as reqd.(Panel should be as per design & drawing approved by Engg in charge) (I)Main incomer 415 V, 100 Amp 4 Pole, 36 KA MCCB,Ics=100%Icu,Adjustable termal & adjustable magnetic : 1 No. (ii) Indicating lights - 03 Nos (3 Nos for Incoming power supply) (iii)Out going 415 V,40 Amp 4 Pole, 25 KA MCCB,Ics=100%Icu,Adjustable termal & adjustable magnetic : 2 No
7Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required a) Double pole
8Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
9Providing and laying earth connection from earth electrode with 6 SWG gia G.I. wire in 15 mm dia G I Pipe from earth eletrode including connection with G.I. thimble excavation and filling as required
10Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
11Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. complete as required.(a) 63 mm dia (OD-63 mm & ID-51 mm nominal)
12Supplying and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminume armoured 4 X 16 sqmm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
13Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminum armoured 4 X 16 sqmm in the existing RCC/ HUME/ METAL pipe as required.
14Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminum armoured 4 X 16 sqmm in the existing masonry open duct as required.
15Supplying and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminume armoured 3.5 X 50 sqmm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
16Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminume armoured 3.5 X 50 sqmm in the existing RCC/ HUME/ METAL pipe as required.
17Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of alluminum armoured 3.5 X 50 sqmm in the existing masonry open duct as required.
18Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.A) All kinds of soil
19Providing and laying in position concerte 1:2:4 ( 1 cement: 2 coares sand: 4 graded stone aggregate 20 mm nominal size) in foundation of pole etc including from work etc as required.
20Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars
21Centering and shuttering including strutting, propping etc. and removal of form for all heights :Foundations, footings, bases of columns, etc. for mass concrete Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57844624
AUTHORITY Government Departments
TENDER VALUE 19.92 Lakhs
LAST DATE 12-10-2026
Authority
Authority Name Border Security Force
Work Description Tender for Supply Installation Testing and Commissioning of Security Lights And Pole Near Ftr Generator Room To Rpao Office At Bsf C Us Umpling Under Ftr Hq Bsf Meghalaya
Basic Detail
Tender No 05/NIT/FTR MEGH/ELECT/2026-27
Bidding Type Tender
Location
City East Khasi Hills
State Meghalaya
Key Dates
Publish Date 03 Oct 2026
Submission Date 12 Oct 2026
Open Date 14 Oct 2026
Finance
Tender Value 19.92 Lakhs
Tender Fee Ref. Documents
EMD 39847
Exemption Not Available
Document List
73741c51-5c79-4e43-9d54-a03da1f4454a.html
BOQ_975991.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Oct 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

73741c51-5c79-4e43-9d54-a03da1f4454a.html

xls

BOQ_975991.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders