Drinking Water Supply and Sanitation Government Departments Closing in 11 days TDR #57844123

Tender For Revised Augmentation Water Supply Scheme For Village Sodhon Block Phillaur District Jalandhar Providing And Installing Deep Tubewell 150Mm I/D Straight 115 Mtr Deep With 10 Mtr Stainless Strainer With Hand Boring, Pumping Machinery, Disinf

Issued by Government Departments · Jalandhar, Punjab
Tender Value
31.78 Lakhs
Estimated cost
Bid Submission
15 Oct 2026
11 days left
EMD
63600
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jalandhar → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Revised Augmentation Water Supply Scheme For Village Sodhon Block Phillaur District Jalandhar Providing And Installing Deep Tubewell 150Mm I/D Straight 115 Mtr Deep With 10 Mtr Stainless Strainer With Hand Boring, Pumping Machinery, Disinfection Unit , Solar Penal , Supplying And Laying Of Pvc Pipes, Sluice Valves And Specials For Rising Main And Distribution System Etc. Household Connection, Construction Of Pump Chamber Size 2.50X2.50, Construction One No. 15Kl (15,000 Itrs) Capacity Having Height 15.00 Mtr Of Up To Fsl & 13.00 Mtr The Cost Of Inlet, Outlet, Overflow & Scour & Vertical Pipes, Di Duck Foot Bends, Expansion Joints, Puddle Collar, Lightening Conductor, Earthing, Ms Steel Ladder Of Tank Portion Stair Case With G.I Pipe Railing On Both Sides Ventilation Aluminum Ladder Inside Ohsr, Scour/Overflow All Civil Works Complete In All Respects. (Under Nabard Xxxi)

BOQ

Name of Work:- Revised AUGMENTATION WATER SUPPLY SCHEME FOR VILLAGE SODHON BLOCK PHILLAUR DISTRICT JALANDHAR Providing and Installing deep tubewell 150mm i/d straight 115 mtr deep with 10 mtr Stainless strainer with Hand Boring, Pumping Machinery, Disinfection Unit , Solar penal , supplying and laying of PVC pipes, Sluice valves and specials for Rising Main and Distribution System etc. Household connection, Const. of Pump Chamber size 2.50x2.50, Construction One No. 15KL (15,000 Itrs) capacity having height 15.00 mtr of up to FSL & 13.00 mtr the cost of inlet, outlet, overflow & scour & vertical pipes, DI duck foot bends, expansion joints, puddle collar, lightening conductor, earthing, MS steel ladder of tank portion stair case with G.I pipe railing on both sides Ventilation Aluminum Ladder inside OHSR, Scour/overflow all Civil Works complete in all respects. (UNDER NABARD XXXI)
Sl. No. Item Description
1WATER SUPPLY
2Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested , equipment as requried such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect.
3b) Boring with 200mm id Housing Pipe
41) Upto 150 m depth BGL.
5Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.
6(b)) 150mm nominal diameter (weight 21.6 kg per metre) 5.4 mm thickness
7Supplying, Fixing & lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore.
8a) 150mm Steel Strainer (slot size 0.15/0.20mm) 5.0 mm thickness
9Supplying, Fixing & lowering of Stainless Steel Socket as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore complete in all respect.
10a) 150mm internal diameter
11Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect.
12(b)) 150mm internal diameter
13Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.
14Supplying at site Wooden Box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore.
15Supplying & Fixing of bail plug of M.S pipe complete with inverted U-hook attched to the bottom plug complete in all respect.
16(b)) 150mm internal diameter (weight 21.6 kg per metre) 5.4 mm thickness
17Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect.
18(b)) 150mm internal diameter
19Development and Stabilizing of the tubewell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
20(a)) Capacity of Air compressor 300 cfm at 250 PSI
21Development and Stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
22Collection of water sample from different strata and testing of sample from approved laboratory (Phisical & chemical Analysis)
23Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.)
24Provision for Sanitary Clay Seal [as per BIS code IS 2800 : 2019] including sterilization of tubewell.
25Constructing one No. of 15 KL (15000 litres) Capacity with sill level not less than 13.00 m height upto FSL 15.00 mtr from formation level complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator single main hole cover lightening conductor etc. complete as described in schedule No.3. Providing and fixing C.I D/F expansion joints (IS-1536-1989) or latest bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, Conforming to ISI - 13382 and C.I D/F sluice Valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes, including providing and installing inlet, outlet scour pipe and overflow C.I double flanged pressure pipes horizontally as per IS:7181/1986 and latest duly ISI marked from bottom dome to duck foot bend and further up to 2.75 mtr as per detail specification. TMT steel & painting of all complete shall be included in cost & P/F aluminium leader inside the OHSR complete in all respect as per specifications. (The specifications & drawing are based on safe bearing capacity of soil is less than 8.75 tone per sqm. In case the safe bearing capacity of soil is less than 8.75 tone per Sqm. The contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceiling Preminum including overflow haudi complete in all respects including cost:- Supplying, fixing and testing at site automatic Electronic Water Level indication system with gun metal float sensor and electrical cable suitable for three phase pump submerisble/ monoblock to be fixed on existing panel for OHSRs complete in all respects. Construction of plinth protection around OHSR with in masonry toe wall & inside earth filling 40mm thick CC 1:2:4 on top over 100 mm thick CC 1:8:16 complete in all respects. Note 1) Providing and applying intergal crystalline slurry of hydrophilic in nature for water proofing management etc. (For vertical and horizontal surface) 2) Providing and applying of swellable type water staop tape etc.
26WATER SUPPLY
27Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge).
28A) Class PN-1 as per ISI
29a) 80mm i/d Sluice Valves flanged
30Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.
31a) Size 0.6 m. x 0.6 m.
32Providing, Stringing out, cutting, Jointing and testing of ISI Marked PVC Pipe (S&S) as per IS 4985 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage. ( (Mechanically Excavation and Including specials)
3390 mm o/d PVC pipe 10 kgf/cm2
34Providing Strining out PVC pipes 6Kgf Cm2 ISI marked as per ISI-4985 the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications for More than 3 mtr street width (Mechanically Excavation and Including specials) (6kgf/ cm2) Pressure
35PVC pipe 63 mm o/d (6kgf/ cm2) Pressure
36PVC pipe 75 mm o/d (6kgf/ cm2) Pressure
37PVC pipe 90 mm o/d (6kgf/ cm2) Pressure
38Providing Strining out PVC pipes 6Kgf Cm2 ISI marked as per ISI-4985 the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications for less than 3 mtr. Street width Complete in all respect. Specifications for Manually Excavation including speicals (6kgf/ cm2) Pressure
39PVC pipe 63 mm o/d (6kgf/ cm2) Pressure
40PVC pipe 75 mm o/d (6kgf/ cm2) Pressure
41PVC pipe 90 mm o/d (6kgf/ cm2) Pressure
42Dismantling of matalled road with Bithminous course 50 to 75 mm thick with base course complete
43Restortation of the Mettalled to its original condition Bituminious course 50 to 70 mm thich C.C 1:8:16 and Making good the same to its original condition complete. All respect as per analysis A-25 (will be done by concerned department.
44Dismantling and Refixing of Interlocking Tile 80mm thick cement concrete Interlocking paver block and including restoration of roads to orginal Position
4563 mm o/d PVC Pipe
4675 mm o/d PVC Pipe
4790 mm o/d PVC Pipe
48Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge).
49Class PN-1 as per ISI
50a) 80mm i/d Sluice Valves flanged
51Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.
52Size 0.6 m. x 0.6 m.
53Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting and including restoration of roads to original Position
5463 mm
5575 mm
5690 mm
57Providing proposed water connection to house hold up to wall with providing, laying jointing testing GI pipe lines 15mm i/d = 2.50 mtr, B-Class as per CSR 28.36 (A), (Above GL), Providing & fixing MDPE pipe 15 mm i/d with specials 2.00 mtr (Below GL) including cost of specials such as tees, bends, sockets, elbow, etc. cutting, threading and testing in trenches in the ground and ISI 15 mm i/d GM ferrule as per IS: 2692 and 3\\" i/d clamp with C.I bib cock, 15 mm i/d as per IS: 210 with stainless steel spindle of approved make as per CSR 30.65 (b)
58Prov. & Fixing Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS standard specifications.
59Providing & installing,testing & commisioning of 1 no electrically driven Submersible Pump set capable of delivering 86 LPM against a head of 62 mtr along with electric panel board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter,Main Switch, VM, AMpere Meter,ELCB, Shunt capacitor. Single phase,preventer,Indicating lamps,Kit-Kat etc. including M.S column Pipe of IS 1239-2004 medium class suitable size 40 mm & length 41 mtr (in 3mtr lengths each with flanges,screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable of 55 mtr length and 2.50mm2 size as per IS694-1990 reaffirmed 2000 complete in all respects
60Rate of Motor with Pump 86 lpm, head 62 mtr
61Panel Board
62WATER SUPPLY
63Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B- Class, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete.
64e) 40mm i/d
65COMMON SCHEDULE OF RATES
66PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
67(xiii)) Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
68(c)) Overall size 2.5sq.mm (50/0.25mm), 3Core
69Providing and installing 80 mm dia delivery main (From Tube well to Duck Foot bend including cost of D.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as D.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects.
70Construction of Pump Chamber size 2.50m X 2.50 m, With gravel pit but including electric wiring as per DWSS standard design & analysis, complete in all respects.
71Providing, Fixing, Installing, Commissioning, Solar Panel Energy System (Monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, Bulb etc in water works site. including Bi-directional meter and inverter of suitable capaity as per guidelines issued by PEDA complete in all respects.
72Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing D-6 & 8 (as per Analysis A-6)
73Providing and Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4 mm dia fencing pole size at bottom 4\\" x 4\\", size top 3\\" x 4\\",Lenght 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects.
74Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing Complete in all respect.
75Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing Complete in all respect.
76Construction of masonry gate pillar including cost of MS Steel Gate size 1.22mtr x 1.37 mtr as per standard Drawing complete in all respects.
77Construction of Cement Concrete, Foot Path with masonry toe wall & earth filling inside water works as per standard Drawing D-7 & Analysis A-10. Complete in all respect.
78Providing & fixing MS Sign board including painting & printing complete as per standard size of DWSS complete in all respects.
79Fine Aggrigate
80Course Aggrigate
81Site clearance
82Surface dressing of ground including removing rank vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m in all kinds of soil.
83Supplying and planting permanent trees in prepared pits and watering
84Planting seasonal flower in beds
85Planting seedlings including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of seedlings at 20cm distance from plant to plant and row to row.
86Planting ground covers (ordinary) including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of sapling at 25cm distance from plant to plant and row to row.
87Provision for one way stand post with Khura complete in all respects Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57844123
AUTHORITY Government Departments
TENDER VALUE 31.78 Lakhs
LAST DATE 15-10-2026
Authority
Authority Name Water Supply And Sanitation Department
Work Description Tender for Revised Augmentation Water Supply Scheme For Village Sodhon Block Phillaur District Jalandhar Providing And Installing Deep Tubewell 150Mm I/D Straight 115 Mtr Deep With 10 Mtr Stainless Strainer With Hand Boring, Pumping Machinery, Disinfection Unit , Solar Penal , Supplying And Laying Of Pvc Pipes, Sluice Valves And Specials For Rising Main And Distribution System Etc. Household Connection, Construction Of Pump Chamber Size 2.50X2.50, Construction One No. 15Kl (15,000 Itrs) Capacity Having Height 15.00 Mtr Of Up To Fsl & 13.00 Mtr The Cost Of Inlet, Outlet, Overflow & Scour & Vertical Pipes, Di Duck Foot Bends, Expansion Joints, Puddle Collar, Lightening Conductor, Earthing, Ms Steel Ladder Of Tank Portion Stair Case With G.I Pipe Railing On Both Sides Ventilation Aluminum Ladder Inside Ohsr, Scour/Overflow All Civil Works Complete In All Respects. (Under Nabard Xxxi)
Basic Detail
Tender No Revised -Sodhon- Nabard-31 -2026
Bidding Type Tender
Location
City Jalandhar
State Punjab
Key Dates
Publish Date 03 Oct 2026
Submission Date 15 Oct 2026
Open Date 15 Oct 2026
Finance
Tender Value 31.78 Lakhs
Tender Fee 1000
EMD 63600
Exemption Not Available
Document List
7f0f6840-b9ab-4ed1-a2c8-29611d2c79ed.html
BOQ_359962.xls
DNIT.pdf
PriceBid.pdf
Tendernotice.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Oct 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

7f0f6840-b9ab-4ed1-a2c8-29611d2c79ed.html

xls

BOQ_359962.xls

pdf

DNIT.pdf

pdf

PriceBid.pdf

pdf

Tendernotice.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders