Tender for Open Well Construction Work in Village Devpura ps Rashmi Under Dmft Head.
Tender Value
12.10 Lakhs
Estimated cost
Bid Submission
15 Oct 2026
12 days left
EMD
24200
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chittorgarh → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Open Well Construction Work in Village Devpura ps Rashmi Under Dmft Head.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation over areas (exceeding 30cm depth, 1.5 mtr in width and 10 SQM in plan) for construction of open well, lift up to 1.5 Mtr. including taking out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 meter.Rates are exclusive of GST. |
| 2 | All kinds of soil. |
| 3 | From 0.00 m to 3.0 m BGL |
| 4 | Ordinary Rock |
| 5 | From 3.00 m to 6.0 m BGL |
| 6 | Hard rock (requiring blasting) useful material 30 % |
| 7 | From 6.00 m to 10.0 m BGL |
| 8 | From 10.00 m to 25.0 m BGL |
| 9 | Recovery of Hard rock useful material 30% |
| 10 | Add extra over item No. 2.39.2-4 for every additional lift of 1.5 Mtr. or part thereof : In Ordinary rock and hard rock. |
| 11 | In ordinary rock and hard rock |
| 12 | From 3.00 m to 4.5 m BGL |
| 13 | From 4.5 m to 6.0 m BGL |
| 14 | From 6.0 m to7.5 m BGL |
| 15 | From 7.50 m to 9.0 m BGL |
| 16 | From 9.0 m to 10.5 0m BGL |
| 17 | From 10.50 m to12.0 m BGL |
| 18 | From 12.00 m to 13.50 m BGL |
| 19 | From 13.50 m to 15.0 m BGL |
| 20 | From 15.0 m to 16.50 m BGL |
| 21 | From 16.50 m to 18.0 m BGL |
| 22 | From 18.0 m to 19.50 m BGL |
| 23 | From 19.50 m to 21.0 m BGL |
| 24 | From 21.0 m to 22.50 m BGL |
| 25 | From 22.50 m to 24.0 m BGL |
| 26 | From 24.0 m to 25.0m BGL |
| 27 | Add extra for shuttering in circular work (in respectivecentering and shuttering items) |
| 28 | Providing and fabricating reinforcement for RCC work including straightening, cutting, bending, placing in position in binding (including cost of binding wire ) all complete up to floor three level |
| 29 | Thermo mechanically treated bars (conforming to relevant IS:1786.) |
| 30 | Providing and layiny in position specified grade of cement concrete for RCC Structure elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement ; 3 coarse sand) and making good the joints excluding the cost of centering shuttering and reinforcement for :Walls (any thickness) including attached pilasters buttresses, plinth and string courses fillets columns pillars pears abutments posts struts etc.M20 grade nominal mix (with graded stone aggregate 20mm nominal size). |
| 31 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10m), fixing in position and applying a priming coat of approved steel primer all complete. |
| 32 | In flates, tees, angles & Channals |
| 33 | In R.S. Joists |
| 34 | Labour charges for horizontal boring 100 mm dia in open well in rocky strata with all types of rock cutting & drilling tools etc. including all T&P required for job including dewatering arrangement. |
| 35 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. |
| 36 | Above 10 HP and up to 15 HP |
| 37 | Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. |
| 38 | 10.0 Sq.mm, 4 core |
| 39 | Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. |
| 40 | 3 core 6.0 Sq.mm |
| 41 | Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. |
| 42 | Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B\\" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer &nut bolts etc. complete in all respect. |
| 43 | 65 mm dia |
| 44 | Providing, installation, testing and commissioning of submersible Monoblock pump set conforming to IS 8034 and 2 pole motor operating at synchronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fibre bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer's design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following poery, tools, and tackles required, construction of temporary works as |
| 45 | 9.3 KW (12.5 HP) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysOct 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender