Tender For Purchase Of Equipment , Fume Hood With Laminar Air Flow Cabinet , Type: Benchtop Laboratory Fume Hood Without Accessories; Application: Suitable For Safe Handling Of Chemical Fumes, Vapours, And Low-To-Medium Hazardous Laboratory Applications;
Tender Overview
Project Description
Tender For Purchase Of Equipment , Fume Hood With Laminar Air Flow Cabinet , Type: Benchtop Laboratory Fume Hood Without Accessories; Application: Suitable For Safe Handling Of Chemical Fumes, Vapours, And Low-To-Medium Hazardous Laboratory Applications; Size: Minimum 5 Feet Width Benchtop Fume Hood; Design: Aerodynamic Fume Hood Design With Smooth Airflow And Minimum Turbulence; Airflow Type: Auto-Bypass/Constant Volume Airflow Design Or Equivalent; Face Velocity: Designed To Maintain Uniform Face Velocity Of 0.4 To 0.6 M/S Or Equivalent As Per Laboratory Safety Requirement; Sash: Vertical Sliding Transparent Toughened Safety Glass Sash With Smooth Movement; Sash Mechanism: Counter-Balanced Sash Mechanism For Safe And Easy Operation; Work Chamber: Chemically Resistant Inner Work Chamber Suitable For Laboratory Fume Handling; Outer Construction: Powder-Coated Gi/Ms/Crca Steel Or Equivalent Corrosion-Resistant Construction; Inner Lining: Chemical-Resistant Liner Such As Compact Laminate/Phenolic Resin/Frp/Ceramic Or Equivalent; Work Surface: Chemical-Resistant Worktop With Raised Edge/Spill Containment Provision; Airfoil: Front Airfoil Profile To Improve Airflow And Reduce Turbulence; Baffles: Rear Baffle Arrangement For Uniform Exhaust Of Fumes; Exhaust Connection: Exhaust Collar/Outlet Provision For Connection To External Ducting System; Lighting: Inbuilt Illumination Provision, If Part Of Standard Fume Hood Supply; Safety Standard: Design Should Comply With Ashrae 110/En 14175 Or Equivalent Fume Hood Safety Standard; Power Supply: 230 V, 50 Hz Power Supply For Inbuilt Electrical Provisions, Wherever Applicable; Excluded Accessories: Blower, Ducting, Exhaust Stack, Scrubber, Base Cabinet, Sink, Service Valves, Electrical Sockets, Gas Cock, Water Tap, And Other Accessories Are Not Included Unless Separately Specified; Installation Requirement: Bidder Shall Indicate Site Requirements For Exhaust Ducting, Blower, And Utilities Separately; Warranty: Minimum 1-Year Comprehensive Warranty. Type: Laminar Air Flow Cabinet; Application: Suitable For Providing A Clean Air Working Environment For Sample Preparation, Media Handling, Microbiology, Tissue Culture, And General Laboratory Applications; Working Area: Minimum 6 Ft × 2 Ft × 2 Ft; Internal Dimensions: Approximately 1828 × 610 × 610 Mm Or Equivalent; Airflow Direction: Horizontal/Vertical Laminar Airflow As Per Site And User Requirement; Cleanliness Class: Iso Class 5/Class 100 Or Better; Hepa Filter: H13/H14 Hepa Filter With Minimum 99.97% Efficiency At 0.3 Micron Particle Size; Pre-Filter: Washable/Replaceable Pre-Filter To Protect Hepa Filter And Blower Assembly; Air Velocity: Uniform Airflow Velocity Of Approximately 0.3 To 0.5 M/S Or Equivalent; Blower Assembly: Dynamically Balanced Low-Noise Blower Suitable For Continuous Operation; Noise Level: Low-Noise Operation, Preferably ≤65 Db; Work Surface: Stainless Steel Work Surface, Ss 304 Or Equivalent; Body Construction: Powder-Coated Ms/Gi Outer Body With Stainless Steel Work Zone Or Equivalent Laboratory-Grade Construction; Side Panels/Front Panel: Transparent Acrylic/Toughened Glass Panels As Per Cabinet Design; Illumination: Inbuilt Led/Fluorescent White Light For Work Area Illumination; Uv Lamp: Germicidal Uv Lamp With Safety Interlock/Timer Provision; Pressure Indication: Magnehelic Gauge/Digital Pressure Indicator For Filter Condition Monitoring; Electrical Socket: Internal Electrical Socket Provision For Small Laboratory Equipment; Control Panel: User-Friendly Control Switches For Blower, Light, Uv, And Power; Power Supply: Suitable For Operation On 230 V Ac, 50 Hz, Single-Phase Power Supply; Stand: Suitable Powder-Coated/Stainless-Steel Support Stand To Be Supplied; Safety Features: Uv Safety Provision, Electrical Protection, And Airflow/Filter Monitoring Provision; Validation/Test Report: Factory Test Certificate/Validation Report For Hepa Filter Efficiency, Airflow Velocity, And Cleanliness Class To Be Provided; Warranty: Minimum 1-Year Comprehensive Warranty.
BOQ
| Sl. No. | Item Description |
| 1 | Fume Hood with Laminar Air Flow Cabinet |
| 2 | Type: Benchtop Laboratory Fume Hood without accessories; Application: Suitable for safe handling of chemical fumes, vapours, and low-to-medium hazardous laboratory applications; Size: Minimum 5 feet width benchtop fume hood; Design: Aerodynamic fume hood design with smooth airflow and minimum turbulence; Airflow Type: Auto-bypass/constant volume airflow design or equivalent; Face Velocity: Designed to maintain uniform face velocity of 0.4 to 0.6 m/s or equivalent as per laboratory safety requirement; Sash: Vertical sliding transparent toughened safety glass sash with smooth movement; Sash Mechanism: Counter-balanced sash mechanism for safe and easy operation; Work Chamber: Chemically resistant inner work chamber suitable for laboratory fume handling; Outer Construction: Powder-coated GI/MS/CRCA steel or equivalent corrosion-resistant construction; Inner Lining: Chemical-resistant liner such as compact laminate/phenolic resin/FRP/ceramic or equivalent; Work Surface: Chemical-resistant worktop with raised edge/spill containment provision; Airfoil: Front airfoil profile to improve airflow and reduce turbulence; Baffles: Rear baffle arrangement for uniform exhaust of fumes; Exhaust Connection: Exhaust collar/outlet provision for connection to external ducting system; Lighting: Inbuilt illumination provision, if part of standard fume hood supply; Safety Standard: Design should comply with ASHRAE 110/EN 14175 or equivalent fume hood safety standard; Power Supply: 230 V, 50 Hz power supply for inbuilt electrical provisions, wherever applicable; Excluded Accessories: Blower, ducting, exhaust stack, scrubber, base cabinet, sink, service valves, electrical sockets, gas cock, water tap, and other accessories are not included unless separately specified; Installation Requirement: Bidder shall indicate site requirements for exhaust ducting, blower, and utilities separately; Warranty: Minimum 1-year comprehensive warranty. Type: Laminar Air Flow Cabinet; Application: Suitable for providing a clean air working environment for sample preparation, media handling, microbiology, tissue culture, and general laboratory applications; Working Area: Minimum 6 ft × 2 ft × 2 ft; Internal Dimensions: Approximately 1828 × 610 × 610 mm or equivalent; Airflow Direction: Horizontal/vertical laminar airflow as per site and user requirement; Cleanliness Class: ISO Class 5/Class 100 or better; HEPA Filter: H13/H14 HEPA filter with minimum 99.97% efficiency at 0.3 micron particle size; Pre-Filter: Washable/replaceable pre-filter to protect HEPA filter and blower assembly; Air Velocity: Uniform airflow velocity of approximately 0.3 to 0.5 m/s or equivalent; Blower Assembly: Dynamically balanced low-noise blower suitable for continuous operation; Noise Level: Low-noise operation, preferably ≤65 dB; Work Surface: Stainless steel work surface, SS 304 or equivalent; Body Construction: Powder-coated MS/GI outer body with stainless steel work zone or equivalent laboratory-grade construction; Side Panels/Front Panel: Transparent acrylic/toughened glass panels as per cabinet design; Illumination: Inbuilt LED/fluorescent white light for work area illumination; UV Lamp: Germicidal UV lamp with safety interlock/timer provision; Pressure Indication: Magnehelic gauge/digital pressure indicator for filter condition monitoring; Electrical Socket: Internal electrical socket provision for small laboratory equipment; Control Panel: User-friendly control switches for blower, light, UV, and power; Power Supply: Suitable for operation on 230 V AC, 50 Hz, single-phase power supply; Stand: Suitable powder-coated/stainless-steel support stand to be supplied; Safety Features: UV safety provision, electrical protection, and airflow/filter monitoring provision; Validation/Test Report: Factory test certificate/validation report for HEPA filter efficiency, airflow velocity, and cleanliness class to be provided; Warranty: Minimum 1-year comprehensive warranty. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender