Tender For Providing, Installation, Testing And Commissioning Of Ivrf Ac Systems At 3(Three) No. Medicine Ward In First, Second And Third Floor Of Old Super Speciality Block, Agmc & Gbp Hospital, Agartala Along With Operation & Comprehensive Annual M
Tender Overview
Project Description
Tender for Providing, Installation, Testing And Commissioning Of Ivrf Ac Systems At 3(Three) No. Medicine Ward In First, Second And Third Floor Of Old Super Speciality Block, Agmc & Gbp Hospital, Agartala Along With Operation & Comprehensive Annual Maintenance Contract (O&Camc) {Operation For 3(Three) Years After Installation And Comprehensive Annual Maintenance For 2(Two) Years After Post Installation Warranty Period Of 1(One) Year} (2Nd Call)
BOQ
| Sl. No. | Item Description |
| 1 | Supply, Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R410A Refrigerant, vibration isolators, suitable foundation etc, with lifting / shifting of the system to required location at terrace/ platform (as per actual site condition) complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The units shall be of latest technology/latest generation of VRF system of the manufacturer and in successful operation for at least last three years. The unit shall be filled with first charge of the refrigerant and ready for use as required. The Unit should have free phase technology so that unit can work in case of phase reversal also without tripping of units. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. Individual Circuit and its Combination of single module units shall be as per approval of the engineer-in-charge. |
| 2 | Supply Installation, Testing & Commissioning of following minimum capacity 4-way VRF Cassette Type Indoor ceiling mounted unit equipped with cordless remote, synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump, cassette grill, insulation, necessary supports, vibration isolation etc, suitable for operation on 230 V±10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT. |
| 3 | Minimum Cooling Capacity: 4.0 TR |
| 4 | Minimum Cooling Capacity: 3.0 TR |
| 5 | Minimum Cooling Capacity: 2.0 TR |
| 6 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric Nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc as required. |
| 7 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 8 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 9 | 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 10 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 11 | 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 12 | 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 13 | 25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 14 | 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 15 | 31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation |
| 16 | 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation |
| 17 | 38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation |
| 18 | 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation |
| 19 | 44.45 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation |
| 20 | Supply, laying, dressing, testing and commissioning of communication cable (of approved make), copper, of appropriate core/size, 2C x 1.5 sqmm, multistrand screened shielded, laying in PVC conduit with bent, tee as required as required for VRF IDUs and ODUs and for central indoor & outdoor monitoring control system. |
| 21 | Providing and charging of additional Refrigerant R410A as required any during actual installation & testing. |
| 22 | Supply, Installation, testing and commissioning of indoor and outdoor monitoring control system for all the ODUs and IDUs of proposed system as per Sl.No1 & 2 including PC monitoring system (with laptop/desktop of latest specification) as per instruction of the Engineer-in charge. |
| 23 | Supply, installation, testing and commissioning of Copper Refnet of appropiate size required copper pipeline. |
| 24 | Supply, installation, testing and commissioning of UPVC drain pipes complete with fittings like elbows. tees. reducers, flanges, supports as per specification and duly insulated with 9 mm thick class-O nitrile rubber insulations complete with supports. |
| 25 | 25 mm dia |
| 26 | 32 mm dia |
| 27 | 40 mm dia |
| 28 | Operation of 300 HP IVRF AC system including all accessories, IDUs, ODUs to be installed during warranty period of 01 year with standby deployment of staff in 2(two) shifts (8 hours), one staff in each shift each day, on all days of the year i.e. 365 days. |
| 29 | Operation and Comprehensive annual maintenance of installed 300 HP IVRF AC system including all accessories after warranty period of 01 year with standby deployment of staff in 2(two) shifts (8 hours), one staff in each shift each day, on all days of the year i.e. 365 days as per terms & conditions and satisfaction of Engineer-in-Charge. |
| 30 | 1st year of CAMC |
| 31 | 2nd year of CAMC Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender