Housing Urban and Rular Development Government Departments Closing in 4 days TDR #57833174

Tender For Providing, Installation, Testing And Commissioning Of Ivrf Ac Systems At 3(Three) No. Medicine Ward In First, Second And Third Floor Of Old Super Speciality Block, Agmc & Gbp Hospital, Agartala Along With Operation & Comprehensive Annual M

Issued by Government Departments · tripura, Tripura
Tender Value
1.51 Crore
Estimated cost
Bid Submission
12 Oct 2026
4 days left
EMD
3.03 Lakhs
Bank guarantee accepted
Document Fee
8000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
tripura → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing, Installation, Testing And Commissioning Of Ivrf Ac Systems At 3(Three) No. Medicine Ward In First, Second And Third Floor Of Old Super Speciality Block, Agmc & Gbp Hospital, Agartala Along With Operation & Comprehensive Annual Maintenance Contract (O&Camc) {Operation For 3(Three) Years After Installation And Comprehensive Annual Maintenance For 2(Two) Years After Post Installation Warranty Period Of 1(One) Year} (2Nd Call)

BOQ

Name of Work:- Providing, Installation, Testing and Commissioning of IVRF AC Systems at 3(three) no. medicine ward in first, second and third floor of Old Super Speciality Block, AGMC & GBP Hospital, Agartala along with Operation & Comprehensive Annual Maintenance Contract (O&CAMC) {Operation for 3(three) years after installation and Comprehensive Annual Maintenance for 2(two) years after post installation warranty period of 1(one) year} (2nd Call)
Sl. No. Item Description
1Supply, Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R410A Refrigerant, vibration isolators, suitable foundation etc, with lifting / shifting of the system to required location at terrace/ platform (as per actual site condition) complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The units shall be of latest technology/latest generation of VRF system of the manufacturer and in successful operation for at least last three years. The unit shall be filled with first charge of the refrigerant and ready for use as required. The Unit should have free phase technology so that unit can work in case of phase reversal also without tripping of units. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. Individual Circuit and its Combination of single module units shall be as per approval of the engineer-in-charge.
2Supply Installation, Testing & Commissioning of following minimum capacity 4-way VRF Cassette Type Indoor ceiling mounted unit equipped with cordless remote, synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump, cassette grill, insulation, necessary supports, vibration isolation etc, suitable for operation on 230 V±10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT.
3Minimum Cooling Capacity: 4.0 TR
4Minimum Cooling Capacity: 3.0 TR
5Minimum Cooling Capacity: 2.0 TR
6Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric Nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc as required.
76.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
89.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
912.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
1015.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
1119 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
1222.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
1325.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
1428.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
1531.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
1634.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
1738.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
1841.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
1944.45 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
20Supply, laying, dressing, testing and commissioning of communication cable (of approved make), copper, of appropriate core/size, 2C x 1.5 sqmm, multistrand screened shielded, laying in PVC conduit with bent, tee as required as required for VRF IDUs and ODUs and for central indoor & outdoor monitoring control system.
21Providing and charging of additional Refrigerant R410A as required any during actual installation & testing.
22Supply, Installation, testing and commissioning of indoor and outdoor monitoring control system for all the ODUs and IDUs of proposed system as per Sl.No1 & 2 including PC monitoring system (with laptop/desktop of latest specification) as per instruction of the Engineer-in charge.
23Supply, installation, testing and commissioning of Copper Refnet of appropiate size required copper pipeline.
24Supply, installation, testing and commissioning of UPVC drain pipes complete with fittings like elbows. tees. reducers, flanges, supports as per specification and duly insulated with 9 mm thick class-O nitrile rubber insulations complete with supports.
2525 mm dia
2632 mm dia
2740 mm dia
28Operation of 300 HP IVRF AC system including all accessories, IDUs, ODUs to be installed during warranty period of 01 year with standby deployment of staff in 2(two) shifts (8 hours), one staff in each shift each day, on all days of the year i.e. 365 days.
29Operation and Comprehensive annual maintenance of installed 300 HP IVRF AC system including all accessories after warranty period of 01 year with standby deployment of staff in 2(two) shifts (8 hours), one staff in each shift each day, on all days of the year i.e. 365 days as per terms & conditions and satisfaction of Engineer-in-Charge.
301st year of CAMC
312nd year of CAMC Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57833174
AUTHORITY Government Departments
TENDER VALUE 1.51 Crore
LAST DATE 12-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Providing, Installation, Testing And Commissioning Of Ivrf Ac Systems At 3(Three) No. Medicine Ward In First, Second And Third Floor Of Old Super Speciality Block, Agmc & Gbp Hospital, Agartala Along With Operation & Comprehensive Annual Maintenance Contract (O&Camc) {Operation For 3(Three) Years After Installation And Comprehensive Annual Maintenance For 2(Two) Years After Post Installation Warranty Period Of 1(One) Year} (2Nd Call)
Basic Detail
Tender No ACE_PWD_MECH_DNIT_46_2526
Bidding Type Tender
Location
City tripura
State Tripura
Key Dates
Publish Date 01 Oct 2026
Submission Date 12 Oct 2026
Open Date 12 Oct 2026
Finance
Tender Value 1.51 Crore
Tender Fee 8000
EMD 3.03 Lakhs
Exemption Not Available
Document List
BOQ_78768.xls
DNIT.pdf
ea5c1fab-bcad-445e-869e-731e0cc3517c.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Oct 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_78768.xls

pdf

DNIT.pdf

html

ea5c1fab-bcad-445e-869e-731e0cc3517c.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders