Tender For Construction Of 0.2 Ml Ugr With Other Ancillary Work At Bhaluchuan, Rairakhol Town
Tender Value
25.06 Lakhs
Estimated cost
Bid Submission
15 Oct 2026
8 days left
EMD
25060
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sambalpur → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of 0.2 Ml Ugr With Other Ancillary Work At Bhaluchuan, Rairakhol Town
BOQ
| Sl. No. | Item Description |
| 1 | Supplying all materials , Labour,T&P for Design , Drawing , Construction , Commisioning & Testing of R.C.C UGR including required specials , SS Lader, lightinging arrangement, water level indicator and piping arrangement up to 5 1 RM from external face all complete as per specification and direction of Engineer-in-charge. |
| 2 | 200 Kl- UGR |
| 3 | Supplying all materials , Labour,T&P and Construction of RCC roof Pump House along with Guard Room with RCC Column Structure of plinth areas (5mtrx3.5mtr) with 3 mtr hight , providing fly ash brick work of 25 cm thick including M.S Door , Windows, painting the pump house and labour cess , all complete as per specification and direction of Engineer-in-charge. |
| 4 | Supplying & Laying in trenches MS pipes of all Classes conforming to IS:3589 - 2001 & IS:3601 - 2006 of the following outside diameter as per specification complete. (Earthwork in trenches, jointing of pipes,specials and fittings to be measured separately)including cost of pipe,conveyance of all materials to worksite,contractor profit & labour cess etc all complete as per direction of Engineer-in-charge. |
| 5 | 168.3 mm O.D.M.S.ERW pipe 4.50mm thick) |
| 6 | Supplying all materials, labour, T&P for flame cutting and facing of MS plate or pipes upto 8mm thick including cost of all labor, material,conveyance to worksite,contractor profit & labour cess for following plate thickness all complete as per specification and direction of Engineer-in-Charge.(Ref:-PH AR-2013,Sl No.2.2.2,P-32) |
| 7 | Providing joints by welding with two welding beads/pass, conforming to IS:816-1998 (Fillet weld) to MS pipes and fittings at site by using welding generator including testing of joints, as per specification complete and direction of Engineer-in-charge. |
| 8 | Cutting of C.I /DI pipe by eletric arc welding,at site including cost of materials,labour,T & P etc all complete |
| 9 | Supplying of the following sizes of Ductile Iron fittings & Specials confirming to IS Specification including cost of contractor profit & labour cess etc all complete as per direction of Engineer-in-charge. (150 mm dia A/F Tee) (150 mm Flange Socket) |
| 10 | Providing flanged joints conforming to IS:3114-1994 to flanged Cast Iron pipes and fittings of the following nominal diameters including testing of joints, cost of bolts and nuts and rubber insertions as per specification complete and direction of Engineer-in-charge.(Ref:-ARPH-2013,Item Sl No.2.1.25,P-14) |
| 11 | 150 mm diameter |
| 12 | Providing push-on-joints conforming to IS:3114-1994 to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes using Rubber Gaskets Conforming to I.S 5382 of S.B.R quality including testing of joints as per specification complete and direction of Engineer-in-charge. |
| 13 | 150mm dia |
| 14 | Supply, install and commission Electromagnetic Flow Meter (EMF) As Per ISO 4064, for Raw/Pure water with accuracy +/- 0.5% of measured value & protection as per given specifications for size 100 mm1000mm including sensor, transmitter surge arrestor, cable GI duct if suitable size for 25 mtrs built in GSM/GPRS ( with Simcard and its charges,valid for 36 months) including the pipe cutting, leveling and installation of flow meter in the pipelines with necessary tool tackles, cranes including 36 months guarantee etc complete, as may be required at site & based on technical specifications. 1) The sensor should be as per IP-68 protection & with flanges of PN 10 rating from CS-1 No. 2) The sensor coil housing shall be IP-68.This protected against external magnetic field. 3) The transmitter shall have one current 4 m A-20 mA output. 4) The current output shall be galvanically / optically isolated. transients without damage. It shall be fitted with switched mode power supply capability 85- 260 V & 45-65 Hz to cope up with power transient without damage 5) Signal & power cables shall be of 50 Mtrs length/each. |
| 15 | Conduit pipe ( PVC Plumbing schedule 4 ) 25 mm diameter with suitable rating of cable with digging, laying & concealed the duct - 25 mtrs/each 7) UPS working on 230 V AC, 50 Hz power supply suitable for 12 hrs continuous operation-1 No.8) Data storage capacity with built in or separate for date time,actual flow rate, totaliser & error messages if any with storage capacity of 120 days -1 No. 9) Proper earthing shall be provided for protection against high voltage surge. 10) Suitable over voltage protection unit for protection of instrument from higher voltage (upto 275 V-300 V AC)11) Fixing flow meter transmitter to internal walls of buildings in a suitably designed panel cabinet with proper locking arrangement with glass window on front door for seeing the readings of flow transmitter and data logger without opening of the panel cabinet. electrical power supply from near by apparatus. The panel cabinet shall be It should house complete ancillaries and including the provision for connection of prewired and with suitable gland entries.The approved make (ABB ,krone,immersion,BermadE&H,Adept etc. |
| 16 | 150 mm Nominal Diameter Flowmeter |
| 17 | Supplying with fittings and fixing of D.I Mechanical dismentaling joint for use to main uninterrupted water supply in the pipeline in case of flowmeter as per specification and direction of Engineer-in-charge |
| 18 | 150mm Nominal Diameter |
| 19 | Supplying ,installation , testing & commission of 3 phase Horizental Submersible pump set of reputed make having discharge of 32 lps against total head of 35 mtr (15 H.P - 2sets) |
| 20 | Supplying ,installation , testing & commission of ATS Controle Pannel of reputed make (15 H.P -2sets) |
| 21 | Supplying ,installation , testing & commission of 10 sqmm 3 Core Flat Copper conducter for Horizental Submersible pump sets including contrctor profit and cess all complete as per specification and direction of Engineer-in-charge. |
| 22 | Supplying, installation, Trsting & Commissioining of DI Resilient Seated Glandless Sluice Valve with double flanged ends for water works purposes conforming to IS 14846 - 2000 for the following rating and nominal diameters as per specification complete(including cost of nut bolt ,washer,rubber inseration sheet& cost of D.I. Gate valve(1:6) with Cape(Talis make)(PN 1.6) |
| 23 | 150mm dia ( Talis Make) |
| 24 | Supplying & Fixing swing check type Reflux Valves (Non-return valves) with double flanged ends conforming to IS : 5312 (Part-I) - 2004 for water works purposes for the following rating and nominal diameters as per specification complete and direction of Engineer-in-charge.(PN 1.6) |
| 25 | 150mm dia |
| 26 | Providing & fixing of CI mechanical joint collar conforming to IS:13382/92 to flanged ends of Cast Iron Pipes or Ductile Iron Pipes including testing of joints as per specification complete and direction of Engineer-in-charge. |
| 27 | 150mm dia C.I mechanical joint collar Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysOct 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender