Tender for E-Tender For Installation Of 1 No. Deep Tubewell Along With Needful Works At 220 Kv Sub Station, Bbmb Jamalpur (Ludhiana).
BOQ
| Sl. No. | Item Description |
| 1 | Drilling of 675mm dia bore with Reverse Rotatry Rig in all kinds of soil including the cost of consumable stores, fuel oil and transportation of rig to the site. complete in all respect. a. Drilling of 675mm dia bore with Reverse Rotatry Rig Upto 150 m depth BGL. PB CSR REF 28.85(A) a |
| 2 | Drilling of 675mm dia bore with Reverse Rotatry Rig in all kinds of soil including the cost of consumable stores, fuel oil and transportation of rig to the site. complete in all respect. b. Drilling of 675mm dia bore with Reverse Rotatry Rig Beyond 150 m depth up to 300 Mtr. PB CSR REF 28.85(A) b |
| 3 | Supplying, lowering of MS Pipe as per IS: 4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore complete in all respect.(b) 355.6mm outer diameter (weight 51.72 kg per mtr) minimum 6mm thickness, PB CSR REF 28.74(B)b |
| 4 | Supplying, Lowering of MS pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore. 200 mm nominal diameter(weight 41.6 Kg per meter) 8.0 mm thickness., PB CSR REF 28.74 A(d) |
| 5 | Supplying, Fixing & Lowering of Strainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore. 200 mm Steel Strainer(slot size .75mm)8.00 mm thickness , PB CSR REF 28.75 A(o) |
| 6 | Supplying & fixing of bail plug of M.S pipe complete with inverted U-hook atteched to the bottom plug complete in all respect.200 mm internal diameter(weight 41.6 Kg per metre) 8.0 mm thickness., PB CSR REF 28.79(A)(c) |
| 7 | Supplying, Fixing & Lowering of Stainless Steel Socket as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore complete in all respect.200 mm internal diameter , PB CSR REF 28.75AA(b) |
| 8 | Supply & Fixing of well cap having thread to to fix on housing pipe complete in all respect350mm internal diameter, PB CSR REF 28.80(f) |
| 9 | Supplying & Fixing of M.S. Clamp of size 150mmX12mm made out of MS Flat 1.52m long, suitable to fit housing pipe including the cost nut & bolts of Suitable size complete in all respect., PB CSR REF 28.77 |
| 10 | Supplying at site wooden box of suitble size with lid & locking arragment for preserving strata sample collected from the bore , PB CSR REF 28.78 |
| 11 | Supplying at site of gravel of 1/16\\" to 1/8\\" sizes including pouring and packing in the annular space between the pipes assembly and the bore.The gravel should be free from, dust,dirt, or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per actual length of pipe)., PB CSR REF 28.88 |
| 12 | Supplying and fixing mild steel centering guides made out of 32 mm x 6 mm thick M.S. bar complete in all respects., PB CSR REF 28.89 |
| 13 | Development and Stabilizing of the tubewell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.Capacity of Air compressor 300 cfm at 250 PSI, , PB CSR REF 28.81(a) |
| 14 | Development and Stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in- chargeincluding cost of tools, appliances & consumable to the satisfaction of Engineer-incharge., PB CSR REF 28.82 |
| 15 | Making Electric logging of borehole with electronic well logger including cost of equipment at site etc. complete in all respect. , PB CSR REF 28.87 |
| 16 | Making temporary water supply arrangement for drilling of tubewell with reverse rotary rig till completion of bore & packing of gravel ( depth of temporary bore up to 90 m) , PB CSR REF 28.86 |
| 17 | Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete.Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra. Class PN-1.0 as per ISI with gun metal flap 150mm i/d Non-return valve, PB CSR REF 28.31(B)(d) |
| 18 | Supplying and laying C.I. specials as per IS:1538 complete as desired by Engineer-in-Charge conforming to ISI specifications.Note: If C.I specials of ISI Marked is used intead of specials confirming to ISI Specifications , than 10% extra on rates of this item will be paid.C.I. specials upto 300mm i/d , PB CSR REF 28.24(a) |
| 19 | Providing & fixing double air valve ISI Marked as per IS-14845 including jointing all carriages complete.C.I Double air valve (Size 80mm) , PB CSR REF 28.30(d) |
| 20 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge). Class PN-1 as per ISI 150 mm i/d Sluice valves flanged, PB CSR REF 28.27 A (c) |
| 21 | Copper earthing: 8 SWG Copper earthing Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (madecylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap(For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long , PB CSR REF 34.14(i)(a) |
| 22 | SWITCH DISCONNECTOR FUSE UNIT (With Sheet Enclosure):Supply and erection of Switch Disconnector Fuse Unit with HRC Fuses(Suitable for DIN HRC Fuses) in sheet enclosure on the existing surfaceConfirms to IS 13947 (Part-III), IEC 60947- 3 complete with G.I. Bolts, Nuts & Connections on both sides of switch with suitable size of thimbles, including cost of DIN HRC fuses as per PWD General Specifications:-SDF TP&N 125Amp., 415volts (With Sheet Enclosure) , PB CSR REF 34.21(B / iv) |
| 23 | Supply and erection of heavy duty Copper thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completelyCopper thimble cable Core size 10 - 16sq.mm, PB CSR REF 34.38 B(ii) |
| 24 | Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) alongthe Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.75mm o/d PVC Pipe Of 4 KGf/sqcm, PB CSR REF 28.13(xx) |
| 25 | Excavation manually in trenches for pipe lines with straight or open cutting in streets and lanes in builtup area where width of street /Lane from wall to wall is less than 3 meter including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. Providing & fixing caution boards, watching, fencing, etc. and removal of surplus soil from the site upto 15 meter distance complete in all respects. Note: Earth work upto 1.5 m. Depth All classes of soil except rocky , PB CSR REF 28.1(a)(i) |
| 26 | Bailing out water from the trenches for making new connections in existing pipe lines including cleaning trimming and dressing the trenches to correct alignment and grade as required by the Engineer-in-charge.Connection with pipe line Upto 300mm i/d , PB CSR REF 28.49(a) |
| 27 | Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage, cost of rubber ring.D.I. Pipe as per IS 8329 DI-K7150mm i/d pipe lines laid complete , PB CSR REF 28.7(B)(A)(c) |
| 28 | Supplying and fixing of ISI Marked CI D-joint (complete with nut, bolts & rubber ring) as per IS:8794 for repair of pipe line including cutting , jointing and testing etc. but excluding cost of excavation complete.150 mm , PB CSR REF 28.10(c ) |
| 29 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonary in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 mtrs., PB CSR REF 6.6 |
| 30 | Cement Concrete 1:8:16 with stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type , PB CSR REF10.6(b) ii AOR |
| 31 | First Class burnt brick work laid in cement sand mortar 1:7 in foundation and plinth, PB CSR REF 11.1(AOR) |
| 32 | Damp proof course 4cm thick of cement concrete 1:2:4 with two coats of bitumen 20/30 penetration @ 1.65 Kg per Sqm laid hot and sanded , PB CSR REF 10.26 |
| 33 | 20mm thick cement plaster damp proof course 1:3 with two coats of bitumen at 1.65 kg per Sqm laid hot and sanded (a) Vertical , PB CSR REF 15.50(a) |
| 34 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4meters above plinth level , PB CSR REF11.6(i) AOR |
| 35 | Extra for work done in additional storey upto 4 metre above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block. , PB CSR REF 11.29(a) |
| 36 | 115mm thick wall laid in cement sand mortar 1:4 without reinforcement in super structure , PB CSR REF 11.36 |
| 37 | Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels , PB CSR REF 9.6 |
| 38 | Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. , PB CSR REF 9.8 |
| 39 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. , PB CSR REF 10.20(AOR) |
| 40 | Terracing consisting of tiles 22.86cm×11.43cum×3.83cm laid over25mm mud plaster, 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot @ 1.65Kg. Per Sqm on top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing , PB CSR REF 13.13(i) |
| 41 | Conglomerate floor 40mm thick cement concrete 1:2:4 on 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100mm fine sand filling using mechanical mixer for mixing material. , PB CSR REF 14.9 |
| 42 | Conglomerate floor 50mm thick cement concrete rate 1:2:4 on 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing material., PB CSR REF 14.10 |
| 43 | 12.5mm thick cement plaster 1:4, PB CSR REF15.9 |
| 44 | Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position panelled, glazed or glazed and panelled. 40 mm thick, PB CSR REF 17.10(xvii) a (i) |
| 45 | Hollock wood cup board shutter with plywood panels or faced on both side fixed in position (excluding the cost of handles, bolts hasp with staple but including the labour for fixing them)(a) 30mm thick , PB CSR REF 17.12(ii) (a) |
| 46 | Kiln seasonal Hollock wood cup board chowkats including iron hold fasts, iron hinges corner straps, wooden knobs or handles fixed in position (Size 45 x 60mm)., PB CSR REF 17.16(ii) |
| 47 | Applying Pink Primer or-aluminium priming coat on wood work including preparation of surface noting & stoping etc. , PB CSR REF 16.16 |
| 48 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade., PB CSR REF 16.17 |
| 49 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge., PB CSR REF 13.74 |
| 50 | Applying priming coat with metal primer on new steel or iron work incluing preparation of surface., PB CSR REF 16.20 |
| 51 | Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend, PB CSR REF 13.76(a) |
| 52 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend, PB CSR REF 13.75(a) |
| 53 | Steel work, fixed independently without connecting plates, including cutting, hoisting and fixing in position R.S. Joist , PB CSR REF 18.1(a) |
| 54 | Cold twisted deformed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding & bending and placing in position complete . , PB CSR REF 18.18 AOR |
| 55 | Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete(a) Doors and Windows frame of Size 118mm×60mm with 40mm wide single rebate weighing 3.43 kg per meter., PB CSR REF 18.24(a) |
| 56 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position , PB CSR REF 18.4 |
| 57 | Cement Cencrete 1:2:4 gola 10cm×10cm concave quardrant along junction of roof with parapet wall finished smooth where specially specified , PB CSR REF 13.55 |
| 58 | Earth filling:-Earth filling under floors with surplus soil containing more than 40% gravel or kankar excavated from foundation and taken only from outside the building plinth in 15cm layers including ramming watering and consolidating lead upto 30 meters. , PB CSR REF 6.8 a (ii) |
| 59 | White washing 3 coats , PB CSR REF16.3 |
| 60 | Supplying & fixing glass panes with glazing clips and special metal sash putty of approved make.Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm area , PB CSR REF 18.25(b) |
| 61 | Footrest for manholeProviding orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design. , PB CSR REF 29.35 |
| 62 | RECESSED HGW CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge welded conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for having (Flush/ Piano type accessories) Step type electronic fan regulators 100watts (socket size), bell push, 5Pin 6Amp. sockets (4Module Box), 16Amp. universal sockets (6Module Box), 6/16/20Amp. Switches etc. and covered with brown bakelite white glazed translucent backside painted sheet 3mm thick etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½\\" deep for walls and 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- (i)(a) Wiring fan point without fan box , PB CSR REF 34.04 (i)(a) |
| 63 | RECESSED HGW CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge welded conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for having (Flush/ Piano type accessories) Step type electronic fan regulators 100watts (socket size), bell push, 5Pin 6Amp. sockets (4Module Box), 16Amp. universal sockets (6Module Box), 6/16/20Amp. Switches etc. and covered with brown bakelite white glazed translucent backside painted sheet 3mm thick etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½\\" deep for walls and 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- (ii) Wiring light point , PB CSR REF 34.04(ii) |
| 64 | RECESSED HGW CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge welded conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for having (Flush/ Piano type accessories) Step type electronic fan regulators 100watts (socket size), bell push, 5Pin 6Amp. sockets (4Module Box), 16Amp. universal sockets (6Module Box), 6/16/20Amp. Switches etc. and covered with brown bakelite white glazed translucent backside painted sheet 3mm thick etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½\\" deep for walls and 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- (v) Wiring 6 Amp. Plug control comprising wall socket point., PB CSR REF 34.04(v) |
| 65 | RECESSED HGW CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge welded conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for having (Flush/ Piano type accessories) Step type electronic fan regulators 100watts (socket size), bell push, 5Pin 6Amp. sockets (4Module Box), 16Amp. universal sockets (6Module Box), 6/16/20Amp. Switches etc. and covered with brown bakelite white glazed translucent backside painted sheet 3mm thick etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½\\" deep for walls and 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- (vi)Wiring 16/20 amp. power plug control point., PB CSR REF 34.04 (vi) |
| 66 | COPPER EARTHING8 SWG COPPER EARTHING :Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt &charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mmdia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mmdeep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-COPPER EARTHING: 8 SWG COPPER EARTHING : Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cmx 60cmx 2mm thick copper plate burried 4.50metre (14.76 feet) below ground level (up to 8metre in Length) with G.I.pipe 20mm dia. (A-class), 3metre long , PB CSR REF 34.14 (i) a |
| 67 | Providing & lowering of submersible pump set complete 33 HP discharge 19500 Gallon per hour at head 80 mtr, REF NON SCHEDULE ITEM |
| 68 | Submersible three core cable size 10mm2 , REF NON SCHEDULE ITEM |
| 69 | Supplying and lowering of 6\\" D/F MS column pipe with R-Jain nut & bolts including labour, Each column pipe 10' long. , REF NON SCHEDULE ITEM |
| 70 | P/F of MS Clamp 6\\" size 24\\" long and 6\\" wide ½\\" thick with nut bolts and washers. , REF NON SCHEDULE ITEM |
| 71 | P/F 6\\" Dia Fibag pressure gauge 0-100 PSI, REF NON SCHEDULE ITEM |
| 72 | Providing of Star Delta Switch Starter Panel with Section Pillor Consisting of BCH/ L&T parts i.e. Digital Ampare meter/ Volt Meter, SPP, Timer etc. , REF NON SCHEDULE ITEM |
| 73 | Providing of Eletronic Chlorine Dozing machine inside the pump chamber , REF NON SCHEDULE ITEM |
| 74 | P/F of Power Factor Controller T/well 25HP make BCH/CELEC/L&T- REF NON SCHEDULE ITEMTechnical Specification 1) MCB TP-63 AMP 1Nos.2) APFC Relay 6 Steps 1 Nos.3) Control MCB(SP)4) Contactors 5 Nos.5) Current Trasformer 200AMP6) Wall Mounted Powder cioated CRCA Sheet Metal enclosure for all parts7) Shunt capacitor 25 KVAR8) Installation and wiring including Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayNov 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender