Tender For Repair And Maintenance Of Internal Electrification, Fittings And Fixtures, Earthing Of Md/ Otm Accns Including E/M Installations At Amdalli Township Of Naval Base Area Karwar.
Tender Value
44.90 Lakhs
Estimated cost
Bid Submission
22 Oct 2026
20 days left
EMD
89800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Uttara Kannada → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of Internal Electrification, Fittings And Fixtures, Earthing Of Md/ Otm Accns Including E/M Installations At Amdalli Township Of Naval Base Area Karwar.
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendants, regulators, sockets, etc can be measured separately) removing the material from wall/ceiling etc, removing materials from site and making good the disturbed surfaces of walls, floors etc as per existing specification and taken as credit complete all as specified and as directed by the Engineer-in-Charge. |
| 2 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross sectional area, PVC insulated FRLS unsheathed cable with multi-stranded copper conductor confirming to IS:694:1990 with ISI marking, drawn through existing conduit, including all accessories in wall/ ceiling/ floor/ roof etc., and accessories IS marked with valid CML No and with modular switch boxes and PVC modular cover plate of suitable size for fixing of switches sockets and fan regulators etc. including 1.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLS cable single core multistranded cable as earth continuity wire and making disturbed surface matching with existing surface all as specified and as directed for One light point controlled by one switch. |
| 3 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross sectional area, PVC insulated FRLS unsheathed cable with multi-stranded copper conductor confirming to IS:694:1990 with ISI marking, drawn through existing conduit, including all accessories in wall/ ceiling/ floor/ roof etc., and accessories IS marked with valid CML No and with modular switch boxes and PVC modular cover plate of suitable size for fixing of switches sockets and fan regulators etc. including 1.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLS cable single core multistranded cable as earth continuity wire and making disturbed surface matching with existing surface all as specified and as directed for One fan point controlled by one switch. |
| 4 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross sectional area, PVC insulated FRLS unsheathed cable with multi-stranded copper conductor confirming to IS:694:1990 with ISI marking, drawn through existing conduit, including all accessories in wall/ ceiling/ floor/ roof etc., and accessories IS marked with valid CML No and with modular switch boxes and PVC modular cover plate of suitable size for fixing of switches sockets and fan regulators etc. including 1.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLS cable single core multistranded cable as earth continuity wire and making disturbed surface matching with existing surface all as specified and as directed for One bell point controlled by one switch. |
| 5 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross sectional area, PVC insulated FRLS unsheathed cable with multi-stranded copper conductor confirming to IS:694:1990 with ISI marking, drawn through existing conduit, including all accessories in wall/ ceiling/ floor/ roof etc., and accessories IS marked with valid CML No and with modular switch boxes and PVC modular cover plate of suitable size for fixing of switches sockets and fan regulators etc. including 1.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLS cable single core multistranded cable as earth continuity wire and making disturbed surface matching with existing surface all as specified and as directed for One 3 pin socket outlet 5 Amp on same board with other switches. |
| 6 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross sectional area, PVC insulated FRLS unsheathed cable with multi-stranded copper conductor confirming to IS:694:1990 with ISI marking, drawn through existing conduit, including all accessories in wall/ ceiling/ floor/ roof etc., and accessories IS marked with valid CML No and with modular switch boxes and PVC modular cover plate of suitable size for fixing of switches sockets and fan regulators etc. including 1.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLS cable single core multistranded cable as earth continuity wire and making disturbed surface matching with existing surface all as specified and as directed for One 3 pin socket outlet 5 Amp on independent board. |
| 7 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross sectional area, copper conductor unsheathed FRLS cable 1100 Volts grade IS-694 marked with valid CML No. single core multistranded cable in and through PVC casing and caping and accessories IS marked with valid CML No (IS-9573-1983 for conduits and IS: 3419: 1976 for conduit accessories) and with modular switch boxes and PVC modular cover plate of suitable size for fixing of switches sockets and fan regulators etc. including 1.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLS cable single core multistranded cable as earth continuity wire and making disturbed surface matching with existing surface all as specified and as directed for One light point controlled by one switch. |
| 8 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross sectional area, copper conductor unsheathed FRLS cable 1100 Volts grade IS-694 marked with valid CML No. single core multistranded cable in and through PVC casing and caping and accessories IS marked with valid CML No (IS-9573-1983 for conduits and IS: 3419: 1976 for conduit accessories) and with modular switch boxes and PVC modular cover plate of suitable size for fixing of switches sockets and fan regulators etc. including 1.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLS cable single core multistranded cable as earth continuity wire and making disturbed surface matching with existing surface all as specified and as directed for One fan point controlled by one switch. |
| 9 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross sectional area, copper conductor unsheathed FRLS cable 1100 Volts grade IS-694 marked with valid CML No. single core multistranded cable in and through PVC casing and caping and accessories IS marked with valid CML No (IS-9573-1983 for conduits and IS: 3419: 1976 for conduit accessories) and with modular switch boxes and PVC modular cover plate of suitable size for fixing of switches sockets and fan regulators etc. including 1.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLS cable single core multistranded cable as earth continuity wire and making disturbed surface matching with existing surface all as specified and as directed for bell point controlled by bell push. |
| 10 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross sectional area, copper conductor unsheathed FRLS cable 1100 Volts grade IS-694 marked with valid CML No. single core multistranded cable in and through PVC casing and caping and accessories IS marked with valid CML No (IS-9573-1983 for conduits and IS: 3419: 1976 for conduit accessories) and with modular switch boxes and PVC modular cover plate of suitable size for fixing of switches sockets and fan regulators etc. including 1.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLS cable single core multistranded cable as earth continuity wire and making disturbed surface matching with existing surface all as specified and as directed for one 3/5 pin socket outlet 6 Amp on same board with other switches. |
| 11 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross sectional area, copper conductor unsheathed FRLS cable 1100 Volts grade IS-694 marked with valid CML No. single core multistranded cable in and through PVC casing and caping and accessories IS marked with valid CML No (IS-9573-1983 for conduits and IS: 3419: 1976 for conduit accessories) and with modular switch boxes and PVC modular cover plate of suitable size for fixing of switches sockets and fan regulators etc. including 1.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLS cable single core multistranded cable as earth continuity wire and making disturbed surface matching with existing surface all as specified and as directed for One 3 pin socket outlet 5 Amp on independent board. |
| 12 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 2.5 sqmm nominal cross sectional area, copper conductor unsheathed FRLS cable 1100 Volts grade IS-694 marked with valid CML No. single core multistranded cable in and through PVC casing and caping and accessories IS marked with valid CML No (IS-9573-1983 for conduits and IS: 3419: 1976 for conduit accessories) and with modular switch boxes and PVC modular cover plate of suitable size for fixing of switches sockets and fan regulators etc. including 2.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLS cable single core multistranded cable as earth continuity wire and making disturbed surface matching with existing surface all as specified and as directed for One 3 pin socket outlet 5 Amp on independent board. |
| 13 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 4 sqmm nominal cross sectional area, copper conductor unsheathed FRLS cable 1100 Volts grade IS-694 marked with valid CML No. single core multistranded cable in and through PVC casing and caping and accessories IS marked with valid CML No (IS-9573-1983 for conduits and IS: 3419: 1976 for conduit accessories) and with modular switch boxes and PVC modular cover plate of suitable size for fixing of switches sockets and fan regulators etc. including 4 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLS cable single core multistranded cable as earth continuity wire and making disturbed surface matching with existing surface all as specified and as directed for with cables 2.5 Sqmm for one 3 pin socket outlet 15 Amps on independent board. |
| 14 | S&F Switch piano type 5 Amp single pole one way complete in repair all as specified and directed. |
| 15 | S&F Switch piano type 5 Amp single pole two way complete in repair all as specified and directed. |
| 16 | S&F flush type bell push 5 Amp, single pole 230 volts one way complete in repair all as specified and directed. |
| 17 | S&F modular switch socket combination, 3 pin along with gang box 5 amp flush type complete in repair all as specified and directed. |
| 18 | S&F switch socket combination multipurpose along with gang box 3 pin 15 Amp and 3 pin 5 amp flush type 2 in 1 complete in repair all as specified and directed. |
| 19 | S&F one module switch modular type, single pole one way 6/10 Amps 230 Volts ISI Marked complete in repair, all as specified and as directed by the Engineer-in-Charge. |
| 20 | S&F one module switch modular type, single pole one way 16 Amps 230 Volts ISI Marked complete in repair, all as specified and as directed by the Engineer-in-Charge. |
| 21 | S&F socket two module type 6 Amps , 3 pin , 230 Volts ISI Marked complete in repair, all as specified and as directed by the Engineer-in-Charge. |
| 22 | S&F socket two module type 6/16 Amps, twin socket , 3 pin , 230 Volts ISI Marked complete in repair, all as specified and as directed by the Engineer-in-Charge. |
| 23 | S&F ceiling rose surface Bakelite min dia 35 mm three terminal complete in repair all as specified and directed. |
| 24 | S&F Modular bell push 6 Amp, 1 modular 230 volts one way complete in repair all as specified and directed. |
| 25 | S&F call bell single pole, ding dong type and including 03 mm thick plastic laminated sheet cover of suitable size with brass screws and washers etc complete in repair all as directed. |
| 26 | S&F cover plate 1 module with inner frame complete in repair all as specified and directed. |
| 27 | S&F cover plate 2 module with inner frame complete in repair all as specified and directed. |
| 28 | S&F cover plate 4 module with inner frame complete in repair all as specified and directed. |
| 29 | S&F cover plate 8 module with inner frame horizontal/vertical type complete in repair all as specified and directed. |
| 30 | S & F modular blank plate, two module 240 volts,50 Hz complete in replacement all as specified and directed. |
| 31 | S&F LED base building security luminaire 45 Watt with pressure die cast aluminium housing with Poly carbonate cover and high power LEDs and secondary lenses with IP 66 Protection including 40x6mm flat iron clamps,nut,bolts,washer with 32 mm dia GI pipe light grade bracket bend to shape not less than 1.2 m long complete in repair all as specified and directed. |
| 32 | Taking down the old unserviceable SK fitting/ FTL fitting/ lamp holder and taken as credit and S&F LED batten tube light fitting with aluminium housing & integrated housing suitable for fixing on wall & surface of 20 watt capacity & 4 feet complete with all electrical connection all as specified and directed by Engr-In-Charge. |
| 33 | Taking down the old unserviceable SK fitting/ FTL fitting/ lamp holder and taken as credit and S&F LED batten tube light fitting with aluminium housing & integrated housing suitable for fixing on wall & surface of 10 watt capacity & 2 feet complete with all electrical connection all as specified and directed by Engr-In-Charge. |
| 34 | S&F Inverter LED 20W light, white colour temperature 6500K along with 4ft batten consisting of a Lithium Ion battery with charging time 8-10 hours and back up time upto 4 hours complete with all connected accessories including connecting up with twin core twisted flexible copper conductor cable of suitable size complete in repair all as specified and directed. |
| 35 | S&F T8 LED tube rod, 18/20 Watt, 4 feet length, 6000K colour temperature, complete in repair, with all accessories, all as specified and directed. |
| 36 | S&F LED Bulb type B22 of 9 watts/ thread bulb as per site requirement complete in repair all as specified. |
| 37 | S&F weather proof bulkhead light fitting made of UV-stabilized poly carbonate plastic body with opal diffuse, complete with 10W LED lamp, suitable for 230V AC supply, IP 54 protection,, including all accessories complete in repair all as specified and directed. |
| 38 | S&F holder, PVC/Polycarbonate type with back plate suitable for batten fittings for LED Lamp or threading bulb as per site requirement complete in repair all as specified and as directed.. |
| 39 | S&F decorative, wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED lamp B22 base including 9W lamp complete in repairs all as specified and directed. |
| 40 | Taking down submain wiring cable of any size/type alongwith earth wire with or without concealed/surface conduit/casing caping complete all as specified and directed. |
| 41 | M&L for Sub main wiring with 2.5 sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, drawn through existing Conduit including 2.5 sqmm (nominal area) single core PVC insulated multistrand unsheathed copper conductor as earth wire and duly connected to all common earth point all as Specified and directed by Engr-in-Charge. |
| 42 | M&L for Sub main wiring with 4.0 sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, drawn through existing Conduit including 4.0 sqmm (nominal area) single core PVC insulated multistrand unsheathed copper conductor as earth wire and duly connected to all common earth point all as Specified and directed by Engr-in-Charge. |
| 43 | M&L for submain wiring with 2 runs of single core 6 Sqmm PVC insulated unsheathed multistranded copper conductor cable, FRLS cable 1100 volt grade drawn through and including PVC surface conduit complete except beam and RCC roof and one run of 6Sqmm PVC insulated unsheathed single core 1100 volts grade multistranded copper conductor cable as earth continuity conductor and connecting with suitable size thimble complete all as specified and as directed by Engineer-in-Charge. Note: two run of 6sqmm size PVC cable , one run of 6 Sqmm size PVC cable as earth wire and one run of PVC conduit shall be measured as one unit length. |
| 44 | M&L for submain wiring with 2 runs of single core 10 Sqmm PVC insulated unsheathed multistranded copper conductor cable, FRLS cable 1100 volt grade drawn through and including PVC surface conduit complete except beam and RCC roof and one run of 10Sqmm PVC insulated unsheathed single core 1100 volts grade multistranded copper conductor cable as earth continuity conductor and connecting with suitable size thimble complete all as specified and as directed by Engineer-in-Charge. Note: two run of 10 sqmm size PVC cable , one run of 10 Sqmm size PVC cable as earth wire and one run of PVC conduit shall be measured as one unit length. |
| 45 | S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete in repair all as specified and directed by Engr-in-charge. |
| 46 | S&F stepped modular type electronic fan regulator 120 W 2 module suitable with existing sheet for 1200 /1400 mm sweep fans complete in replacement. |
| 47 | S&F Sheet metal enclosure DB 4 way ,Single pole and neutral with 200 Amps rated bus bar,230 volts double door type including connecting all connections of wire to MCBs with proper lugs & arrangements, making good to the disturbed surface including taking down existing DB all as specified and directed. |
| 48 | S&F Sheet metal enclosure DB 8 way ,Single pole and neutral with 200 Amps rated bus bar,230 volts double door type including connecting all connections of wire to MCBs with proper lugs & arrangements, making good to the disturbed surface including taking down existing DB all as specified and directed. |
| 49 | S&F Sheet metal enclosure DB 12 way ,Single pole and neutral with 200 Amps rated bus bar,230 volts double door type including connecting all connections of wire to MCBs with proper lugs & arrangements, making good to the disturbed surface including taking down existing DB all as specified and directed. |
| 50 | S&F Sheet metal enclosure DB 4 way ,Triple pole and neutral with 200 Amps rated bus bar,415 volts double door type including connecting all connections of wire to MCBs with proper lugs & arrangements, making good to the disturbed surface including taking down existing DB all as specified and directed |
| 51 | S&F Sheet metal enclosure DB 8 way ,Triple pole and neutral with 200 Amps rated bus bar,415 volts double door type including connecting all connections of wire to MCBs with proper lugs & arrangements, making good to the disturbed surface including taking down existing DB all as specified and directed |
| 52 | S&F VTPN distribution box 4 way, AC, TP & neutral metal enclosure, double door, 415V AC, concealed type with suitable bus bar, neutral link, earth link suitable for MCCB, as incomer and MCB,SP as out going after taking down existing DB complete in replacement all as specified and directed. |
| 53 | S&F VTPN distribution box 8 way,, AC, TP & neutral metal enclosure, double door, 415V AC, concealed type with IP-43 protection complete with suitable bus bar, neutral link, earth link suitable for MCCB 125/150Amps as incomer and MCB, SP as out going after taking down existing DB complete in replacement all as specified and directed. |
| 54 | S&F sheet metal enclosure with Single pole enclosure with a two pin and earth plug and socket complete with one single pole MCB with 20 Amps after taking down existing complete in replacement all as specified and directed. |
| 55 | S&F MCCB, 4 pole, 415 volt AC, 63 amps, fixed type with breaking capacity 16KA complete in replacement all as specified |
| 56 | S&F MCCB, 4 pole, 415 volt AC, 100 amps, fixed type with breaking capacity 16KA complete in replacement all as specified. |
| 57 | S&F MCB TPN 25-63 Amps 4 Pole, with breaking capacity 16 KA along with replacement of old unserviceable one complete all as specified and directed. |
| 58 | S&F MCB TPN 16-32 Amps 4 Pole, with breaking capacity 16 KA along with replacement of old unserviceable one complete all as specified and directed. |
| 59 | S&F MCB TPN 40-100 Amps 4 Pole, with breaking capacity 16 KA along with replacement of old unserviceable one complete all as specified and directed. |
| 60 | S&F MCB SPN 240 Volts 40 to 63 Amp breaking capacity 10 KA along with replacement of old unserviceable one complete all as specified. |
| 61 | S&F MCB SPN 240 Volts 32 Amp breaking capacity 10 KA along with replacement of old unserviceable one complete all as specified. |
| 62 | S&F MCB SP 240 Volts 5 to 32 Amps breaking capacity 10 KA along with replacement of old unserviceable one complete all as specified and directed. |
| 63 | M&L for taking down & Overhauling of ceiling fan any size and make, dismantling parts, properly cleaning/removing old existing grease oil and removing old paint from blades and body including down rods complete. Applying new oil grease, varnishing of winding, cleaning dust, rust and applying one coat white enamel paint over a coat of steel primer, assembling and refixing at site complete all as specified. |
| 64 | M&L for taking down & Overhauling of Exhaust fans/wall mounted fans/ pedestal fans any size and make, dismantling parts properly cleaning/removing old existing grease oil and removing old paint from blades. Applying new oil grease, varnishing of winding, cleaning dust, rust , assembling and refixing at site complete all as specified. |
| 65 | M&L for taking down ceiling fan, removing the old burnt motor, and replacing the conventional motor with a BLDC motor suitable for operation with regulator/remote, including electronic circuit, blades, down rod, canopy, and all necessary connecting items, complete all as directed. |
| 66 | M&L for taking down & repairing of Exhaust fans of any make and any sweep dismantling its parts cleaning properly, rewinding with super copper enamelled wire suitable gauge, varnishing, oiling and greasing replacing petti items such as split pins, assembling and testing after fixing of fan blades, refixing at site with required plywood and connecting complete. Note: Worn out/damaged parts such as canopy, rubber bush, capacitors, and Gun metal bushes, ball bearing shall be measured and paid separately as S&F under relevant items of Sch 'A'. |
| 67 | S&F gun metal bush of any type and size of ceiling fan/ exhaust fan/ Wall fans complete in replacement. |
| 68 | S&F ball bearing for Ceiling fan 1200/1400 mm sweep complete in replacement. |
| 69 | S&F ball bearing for Exhaust fan 150/200/300/350/450 mm sweep complete in replacement. |
| 70 | S&F capacitor 1.5 mfd, 230 volts, AC + 5% complete in replacement all as specified and directed. |
| 71 | S&F capacitor 2.5 mfd, 230 volts, AC + 5% complete in replacement all as specified and directed. |
| 72 | S&F PVC / metallic clamp for holding capacitor of any type/ size complete in replacement all as directed. |
| 73 | S&F MS fan down rod 1 feet for holding ceiling fan complete in replacement all as specified and directed by Engr-in-charge. |
| 74 | S&F MS fan down rod 2 feet for holding ceiling fan complete in replacement all as specified and directed by Engr-in-charge. |
| 75 | S&F wooden frame of thickness 6 mm of suitable size for fixing of exhaust fan in existing hole including all nut/bolts complete in repair all as specified and directed by Engineer-in-Charge. |
| 76 | S&F cup made of plastic complete with nut bolt for fixing in position suitable for ceiling fan 1200mm/1400mm sweep complete in replacement all as directed. |
| 77 | S&F blade suitable for 1200mm sweep Ceiling fan complete in replacement all as directed. |
| 78 | S&F blade suitable for 1400mm sweep Ceiling fan complete in replacement all as directed. |
| 79 | S&F Bollard light, New generation, energy saving, environmental friendly, long life of size Height 900 mm, Diameter 120 mm, Base plate 160 mm aesthetically designed aluminium landscape IP 65 luminaire for diffused lighting with 8W, 3000K high power LED as light source. Providing and laying PCC 1:2:4 (M15) foundation of size 300×300×450 mm with sand bedding, conduit provision, foundation bolts, curing and finishing for mounting bollard light including all materials and labour, complete in repair all as specified and directed by Engr-in-Charge. Make: Jaquar- MLED-MABOL-16L or equivalent Panasonic/ Bajaj/ Havells. |
| 80 | S&F new generation, post top lantern or garden light fitting 20 W LED, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire complete in repair all as specified and directed by Engr-in-Charge. |
| 81 | S&F XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor,1100 volts grade, cross sectional area 10 sq mm 2 core including taking down old unserviceable cable complete in repair all as specified and directed. |
| 82 | S&F XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor,1100 volts grade, cross sectional area 10 sq mm 4 core including taking down old unserviceable cable complete in repair all as specified and directed. |
| 83 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying/taking out cable and getting out in soft/loose soil all as specified and directed. |
| 84 | Returning, filling in soil including spreading levelling, watering and well ramming in layers not exceeding 25cm thick all as specified and directed. |
| 85 | Removing excavated material/ soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed. |
| 86 | Supply and laying flexible DWC-HDPE pipe of nominal dia 63 mm, conforming to IS 16205, suitable for laying XLPE cables, including drawing of cables through the pipe, making joints, bends and fixing in position, complete in repair all as specified and directed. |
| 87 | Supply and laying galvanised iron tubing, light grade of size 40 mm dia with all fittings as in cable protection, laid in trenches, including taking down existing unserviceable GI pipes & its connections complete all as specified and directed by Engr-in-Charge. |
| 88 | Demolition of un-reinforced cement Concrete in road and paving's not exc 15 cm thickness (below or above ground level) |
| 89 | M&L for PCC 1:2:4 type B2 (40mm graded crushed stone aggregate) as in road filling all as specified and directed. |
| 90 | M&L for testing of resistance of earth pits of transformer/panels/ buildings or any other indicated place etc after testing report will be furnished to Engr-in Charge in standard format approved by Engr-in Charge. |
| 91 | M&L in replacement of Earthing complete with galvanised steel earth electrode 60Cm x 60Cm x 6 mm thick directly buried in ground (earth pit not less than 2.25 M deep below the normal ground level connected to galvanised earth lead dia 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron steel including necessary excavation earth work PCC chamber CI chamber cover protection pipe watering pipe etc. (Complete all as shown in electrical plate No 3 and connected to earthing test point complete including excavation earthwork, PCC chamber, chamber cover ,funnel watering and protection pipe etc all specified and directed and testing on completion. Note:- If the desired earth resistance is not less than 5 Ohms, earthing shall be redone by the contractor at no extra cost to the department. |
| 92 | M&L for Earth continuity galvanised earth lead dia 4 mm dia or main earthing lead fixed to wall with clamps or recess or crosses or buried in ground or drawn in conduits/pipe or fixed to poles or any other indicated situation for loop earthing etc including taking down as required all as specified and directed by Engr-in-Charge. |
| 93 | M&L for painting of building electrical panel of size 3ftx3ft including scraping, cleaning, surface preparation and applying one coat of red oxide primer and two coats of synthetic enamel paint using mechanical spray (maximum working pressure of 3300 PSI), marking and lettering complete as directed by Engr-in-charge. |
| 94 | S&F 20A, 220V AC, 1-way modular switch suitable for geyser/water heater, complete with matching modular plate, GI/metal/PVC concealed box, fixing accessories and all connections, complete in repair as specified and directed. |
| 95 | S&F 40 Amps, 2 Pole, 30mA sensitivity, 240V AC, Type-A RCCB, suitable for protection against earth leakage/shock hazards, complete in repair, with necessary accessories, connections, fixing and testing, as specified and directed. |
| 96 | S&F 32 Amps, 4 Pole, Automatic Changeover/ Changeover Contactor (ACCL) suitable for automatic transfer of load from normal mains supply to DG supply and vice versa, complete with necessary control wiring, interlocking arrangement, auxiliary contacts, mounting accessories, connections and testing, in replacement of existing ACCL, complete in repair all as specified and directed. |
| 97 | S&F 2.5 inch dia surface mounted LED light fitting, suitable for 230V AC, complete with LED driver, diffuser, mounting accessories, connectors and all necessary wiring/ terminations, complete in repair all as specified and directed. |
| 98 | S&F/ laying of 1100 volts grade PVC insulated, screened, PVC bedded, unarmoured, sheathed electric power cable with stranded copper conductor of size 2.5 Sqmm, 3 core complete in repairs all as specified and directed by Engr-in-charge. |
| 99 | M&L for dressing of hanging/loose electrical wires by enclosing in 20 mm dia PVC flexible hose/Casing capping or higher size as per site requirement and fixing with nylon cable ties at suitable intervals, including all materials, labour, and accessories, complete all as specified and directed by Engr-in-charge. |
| 100 | M&L for opening the geyser 25/50 ltr capacity and taking out inner tank and glass wool from inside the geyser for descaling and washing with acid to remove the scale, dirt etc if any and re-fixing the same after re-assemble into the geyser and proper filling of glass wool around inner tank complete all as specified and directed by Engr in charge. |
| 101 | S&F plug top 3 pin 16 Amp 240 volts ISI marked complete in replacement all as specified and directed by Engr in charge. |
| 102 | S&F only gate valve of size 15mm dia including removal of old one by cleaning the pipe line all as specified and directed by Engr in charge. |
| 103 | S&F non return valve (gun metal) of size 15mm including removal of old ones complete all as specified and directed by Engr in charge. |
| 104 | S&F fusible plug suitable for 25 Ltrs Cap storage type water heater including provision of necessary GI fittings removal of existing valves complete in replacement all as specified and directed by Engr-in-Charge. |
| 105 | Supply heating element 1.5/2 KW of storage type water heater of compatible type including making all connections by replacing inter connecting copper conductor cables and removal of old unserviceable elements complete in replacement all as directed by Engineer-in-Charge of capacity ISI Marked |
| 106 | S&F thermostat suitable for 25/50 ltrs capacity storage type water heater including removal of old unserviceable ones complete in replacement all as directed by Engineer-in-Charge. |
| 107 | S&F pressure release valve suitable for 25 ltrs geyser complete in replacement all as specified and directed by Engineer-in-Charge. |
| 108 | S&F drain plug brass with washer suitable for 25 ltrs geysers complete in replacement all as specified and directed by Engineer-in-Charge. |
| 109 | S&F geyser hot water heavy duty connection branded flexible pipe made out of brass female coupling for connecting geyser outlet to existing tab of 12/15 mm dia, 600 mm long complete in replacement all as specified and directed by Engineer-in-Charge. |
| 110 | S&F geyser hot water heavy duty connection branded flexible pipe made out of brass female coupling for connecting geyser outlet to existing tab of 12/15 mm dia , 450 mm long complete in replacement all as specified and directed by Engineer-in-Charge |
| 111 | Attending internal Electrification fault/ complaint of emergent nature related to all internal wiring and connected accessories.Note:1. All the materials required shall be paid separately under relevant item of the schedule.2. Tools required for the same will be provided by the contractor. |
| 112 | Note for Item No.1 to 111: All tools/ladders/equipment and other accessories required for proper and complete execution of the work throughout the contract period shall be provided by the Contractor at his own cost. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysOct 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender