Tender for Repair / Maintenance Of Air Conditioning Plant And Other Misc Works At Hemrl Sutarwadi Under Ge(I) R&D Pashan
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-Oct-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 29-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling and disconnecting of Reciprocating compressor any capacity /make of central Air conditioning plants by putting plates to plant the suction and discharge valve by taking down the crank shaft and reinstalled in the position with correct alignment after cleaning, overhauling testing of Compressor including removing unserviceable /damaged internal parts cleaning overhauling complete replacement of worn out Spare parts such as suction reed, discharge reeds, Cylinder liners, Loading / unloading system compressor spring, Oil pump bearing, shaft Bearing, Shaft Wisher Washers nut bolts, Gaskets, shaft seal, unserviceable flanges sockets \\"O\\" ring, cutting, balancing the crank shaft if required & reassembling the compressor including changing the compressor oil, leak testing with Nitrogen Pressure , repairing leakages & charging R-22 gas, charging of compressor oil and refrigerant completely complete all as specified and directedNote: - Nitrogen Gas, R-22 Gas will be Masured and Paid Separately |
| 2 | Supply Only Crank shaft for Voltas compressor sutable for model No. 5H40 complete all as specified and directed |
| 3 | Supply Only seal End Bearing for Voltas compressor sutable for model No. 5H40 complete all as specified and directed |
| 4 | Supply Only Pump end Bearing for Voltas compressor sutable for model No. 5H40 complete all as specified and directed |
| 5 | Supply Only Connecting Road Bearing for Voltas compressor sutable for model No. 5H40 complete all as specified and directed |
| 6 | Supply Only Oil Ring for Voltas compressor sutable for model No. 5H40 complete all as specified and directed |
| 7 | Supply Only Comp. Ring for Voltas compressor sutable for model No. 5H40 complete all as specified and directed |
| 8 | Supply Only Piston Pin for Voltas compressor sutable for model No. 5H40 complete all as specified and directed |
| 9 | Supply Only Piston Lock Ring for Voltas compressor sutable for model No. 5H40 complete all as specified and directed |
| 10 | Supply Only Oil Pump Assembly Complet Set for Voltas compressor sutable for model No. 5H40 complete all as specified and directed |
| 11 | Supply Only Oil Pump Bush for Voltas compressor sutable for model No. 5H40 complete all as specified and directed |
| 12 | Supply Only Pum End Bearing Wisher for Voltas compressor sutable for model No. 5H40 complete all as specified and directed |
| 13 | Supply Only Cranck Shaft Wisher for Voltas compressor sutable for model No. 5H40 complete all as specified and directed |
| 14 | Supply Only Shaft Seal Assembly Wisher for Voltas compressor sutable for model No. 5H40 complete all as specified and directed |
| 15 | Supply Only Seal Cover Plate for Voltas compressor sutable for model No. 5H40 complete all as specified and directed |
| 16 | Supply Only Gasket Set for Voltas compressor sutable for model No. 5H40 complete all as specified and directed |
| 17 | Supply and Fix In repair Crank Case Heater for Voltas compressor sutable for model No. 5H40 complete all as specified and directed |
| 18 | Supply only Compressor Oil Seal complete all as specified and directed |
| 19 | Supply Only Suction Valve Disc for Voltas compressor sutable for model No. 5H40 complete all as specified and directed |
| 20 | Supply Only Suction Valve Spring for Voltas compressor sutable for model No. 5H40 complete all as specified and directed |
| 21 | Supply Only Star Washer for Voltas compressor sutable for model No. 5H40 complete all as specified and directed |
| 22 | Material and labour for disconnecting electrical connections of motor located at the top of cooling tower, keep cables at safe custody for reconnection and dismantling and taking out fan blade assembly along with motor mounted on base frame at the top of cooling tower after cutting/dismantling all nuts, bolts and fixtures from the mounting frame and removing whole assembly including motor and base frame from the top of cooling tower with the help of necessary T&P for servicing of cooling tower suitable for 15 TR to 60 TR capacity and comprising of following Complete all as specified and directed :-(i) Cleaning /scrapping of inner and outer surface of FRP basin, repair of damaged portion if any incuding FRP lining of all surfaces joints to avoid leakage including replacement of all nuts and bolts joining all parts of Basin complete. (ii) servicing cooling tower plant through cleaning re-agent complete pipe line, including servicing of cooling tower motor, fan and make the necessary alignment with motor. (iii) Replacement of bearing with suitable capacity including greasing and replacement of nut, bolts and preventing leakage with adheives etc (iv) Taking out PVC fills blocks, cleaning and refixing as per existing location and channel direction. (v) Servicing of spray header and sprinkler assembly complete. (vi) Repair of water strainer complete. (vii) Rate for Spare parts will be measured and paid separately under relevant items of Schedule as free for fixing. |
| 23 | Supply only Suitable bearings for Fan Motor of Cooling Tower of Capacity 15 TR to 60 TR Complete all as specified and directed |
| 24 | Supply only Suitable bearings for Fan Motor of Cooling Tower of Capacity 75 TR to 180 TR Complete all as specified and directed |
| 25 | Supply only Sprinkler Hub top and bottom portion with PVC Pipe and cap complete set for capacity 15 to 60TR complete all as specified and directed |
| 26 | Supply only the following spare parts of cooling tower complete all as specified and directed :-(a) PVC fills in columns of size 60 x 30 x 15 cm or next higher size as per existing specification and requirement complete all as specified and directed |
| 27 | (b) PVC fills in columns of size 60 x 15 x 15 cm or next higher size as per existing specification and requirement complete all as specified and directed |
| 28 | Supply & Fix in repairs 10 Micron Filter class G3 as per EN 779 for AHU complete all as specified and directed of following size:- a)490mm x 610mm x 45mm |
| 29 | b) 500mm x 630mmx45mm |
| 30 | c ) 510mm x 610mm x 45mm |
| 31 | d) 500mm x 500mmx45mm |
| 32 | e) 510mm x 630mm x 45mm |
| 33 | f) 630mm x 630mm x 45mm |
| 34 | g ) 630mm x 510mm x 45mm |
| 35 | h) 590mm x 700mm x 45mm |
| 36 | i) 630mm x 500mm x 45mm |
| 37 | j) 630mm x 400mm x 45mm |
| 38 | k) 470mm x 630mmx 45mm |
| 39 | l) 500mm x 600mm x 45mm |
| 40 | m) 910mm x 720mm x 30mm |
| 41 | n) 600mm x 600mm x 45mm |
| 42 | o) 470mm x 610mmx 45mm Please Enable Macros to View BoQ information |
| 43 | o) 470mm x 610mmx 45mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender