Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #57831990

Tender For Repair/Maintenance Of Geysers And Connected Items For Md Accn And Otm Accn At Hisar Mil Stn Under Ge Hisar

Issued by Statutory Bodies & Commissions/Committees · Hisar, Haryana
Tender Value
25 Lakhs
Estimated cost
Bid Submission
22 Oct 2026
19 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hisar → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maintenance Of Geysers And Connected Items For Md Accn And Otm Accn At Hisar Mil Stn Under Ge Hisar

BOQ

Name of Work:- REPAIR/MAINTENANCE OF GEYSERS AND CONNECTED ITEMS FOR MD ACCN AND OTM ACCN AT HISAR MIL STN UNDER GE HISAR
Sl. No. Item Description
1Attending of complaints pertaining to unsatisfactory/unfunctional state of solar water heater/ Geyser through telephone or in person on detailment at MES Service centre for Married/OTM accommodation in Hisar Mil Station by rectification of fault of geysers / solar water heater points complete and carrying out repairs to the extent of disconnection and carefully taking down Geysers/faulty wires, sheet metal enclousers, switches & sockets, PVC Connection, conduits, boxes, main switches, MCBs, DBs heating elements, heating plate assembly, glasswool, pressure valve,thermostat, split plates, indicating lamps, inner and outer tank and other E/M faults pertaining to particular instrument including wire upto 1.00 mtr and insulation tape required for the rectification of defect and refixing all serviceable/new electrical and mechanical items to existing/shifted location all specified by Engg-in-charge and make good for functional serviceability after repair/replacement of fixtures complete. Notes:- 1.Contractor will provide one geyser/solar water heater mechanic and one helper for daily complaint except Sunday/Holidays 2. Penalty will be charged @ 50 Rs per day on absent either mechanic/helper or Both.3. Cost of work requiring replacement of spare parts/items shall be measured as supply only and paid separately. Contractor shall provide the complaint slip containing 100 pages in duplicate (in two colour) of existing size properly binded and printed all as per sample and directed by Engr-in-Charge.
2S & F in renewal of 15mm dia fancy type pillar tap cast copper alloy with capstan head, chromium plated, screwed down, high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe or for brass ferrule complete all as specified & directed.
3S & F in renewal gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe, ISI marked and fixed of size 25mm bore dia complete all as specified and directed.
4S & F in renewal of gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe, ISI marked and fixed of size 20mm bore dia complete all as specified and directed.
5S & F in renewal of gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe, ISI marked and fixed of size 15mm bore dia complete all as specified and directed.
6Supply only pressure release valve for geyser 15 mm dia all as specified and directed by Enge in charge.
7Supply only geyser heating element 1500 watt suitable for any type, size & make of geyser complete all as specified and directed by Enge in charge. Make : Hincavo/ SHBM/ PNK Agency/PMW/ Ultino-pro/ R AND I/ Swastik/ Roshni/ Litost/ Airex/ Generic/ PMW
8Supply only geyser heating element 2000 watt suitable for solar water heater of any type, size complete all as specified and directed by Enge in charge. Make:Hincavo/SHBM/PNK Agency/PMW/Ultino-pro/ R AND I/ Swastik/ Roshni/ Litost/Airex/ Genric/PMW
9Supply only thermostat/cut off of geyser suitable for any type, size/capacity & make of geyser.
10Supply only PVC Cable of size 2.5 sqmm 3 core copper conductor round type complete all as specified and directed by Enge in charge. Make-Anchor/Havells/polycab/KEI/RR Kable
11Supply only indicating lamp round type suitable for Geyser complete all as specified and directed by Enge in charge.
12Supply only S/S heating plate assembly complete with water inlet & outlet, rubber gasket, nuts and bots and washers of required size suitable for 25 Ltr Capacity Geyser of any type and make etc complete all as specified and directed by Enge in charge.
13Supply only glass wool for geyser vessel of any size and capacity complete all as specified and directed by Enge in charge.
14Supply only mild steel holding/anchor bolts and nuts machine made of size 10cm to 15cm long and dia of bolt 10mm to 15mm complete all as specified and directed by Enge in charge.
15Supply only dead nut/Safety plug of brass as per sample suitable for Geyser of any capacity/make complete all as specified and directed by Enge in charge.
16Supply only inner tank of geyser capacity 25 ltr made out of 16 SWG sheet Steel suitable for Geyser of any type and make to match the existing size and shape of inner tank of Geyser installed at site complete all as specified and directed by Enge in charge.
17Supply only outer tank of geyser made out of GI sheet of existing gauge, shape including top and bottom cover plate complete suitable for inner tank 25 ltr capacity geyser of any make complete all as specified and directed by Enge in charge.
18Supply only metal clad plug Socket single phase 20 Amp (enclosure type) suitable to fix in sheet and metal enclouser for geyser complete all as specified and directed by Enge in charge.Make:-Havells/HPL/Benlo
19Supply only metal clad plug top single phase 20A (enclosure type) suitable to fix in sheet and metal enclouser for geyser complete all as specified and directed by Enge in charge. Make:-Havells/HPL/Benlo
20Supply only hot water PVC connection of 15mm bore heavy duty, length upto 45cm with brass nut joints and washers at both ends complete all as specified and directed by Enge in charge.
21Supply only Cold water PVC connection of 15mm bore heavy duty, length upto 45cm with brass nut joints and washers at both ends complete all as specified and directed by Enge in charge.
22Supply and fix sheet metal single pole and neutral enclosure provision of one SPN MCB of 20 Amp rating 240 volt and 2 pin earth plug and socket complete all as specified and directed by Engg-in-charge. Note: Cost of making good and taking down existing sheet metal enclosure is included in this item and nothing will be paid extra on this account.
23Taking down unserviceable geysers 25/35 litre capacity of any make opening up for inspection, inlet, outlet and thermostat pipe, washing the inner tank with anti corrosion solution, the inlet & outlet valves, safety valve, dead weight and refixing the geysers in position and testing for proper functioning including soldering/welding where required to stop the leakage and other jobs connected with plumber and mason which would be required in connection with making the geyser functional complete all specified and directed by EIC.
24Supply only MCB, SPN 6 - 32 AMP, 240V, 10 KA (B Curve) complete all specified and directed by EIC.
25Supply only MCB, SP 6 - 32 AMP 240 V 10 KA (B Curve) complete all specified and directed by EIC.
26M&L for sub main wiring with 2 runs of single core 6 Sqmm FRLS PVC insulated unsheathed cable, 1100V grade with copper multi stranded conductor drawn through and including surface PVC conduit ISI marked medium grade 20mm dia with all fitting and fixing accessories including one run of 6 Sqmm FRLS PVC insulated unsheathed Copper cable green colour as earth wire connected to earth including taking down existing sub main wiring complete all specified and directed by EIC.
27All as per serial item 26 here in before but with 2 run of single core 4 Sqmm cable with 4.0 sqmm earth wire complete all specified and directed by EIC.
28M&L for concealed point wiring for one light point controlled by one way switch complete with FRLS PVC insulated /unsheathed stranded copper conductor of wire 2.5 Sqmm, 1100 Volt grade, alongwith one single core of same size stranded copper as continuous earth wire to common earth dolly in and including PVC conduit pipe fitting medium grade of 20 mm dia fixed in concealed surface of wall/ceilling/false ceilling including cutting /chasing in wall as required with powder coated sheet metal terminal boxes modular type of required sizes and thickness (factory made) sunk in wall where as required and accessories complete and make good of disturbed surface complete all specified and directed by EIC.
29M&L for point wiring for one light point controlled by one way switch complete with FRLS PVC insulated /unsheathed stranded copper conductor of wire 2.5 Sqmm , 1100 volt grade, alongwith one single core of same size stranded copper as continuous earth wire to common earth dolly in existing PVC conduit/ pipe casing fitting as required with powder coated sheet metal terminal boxes modular type of required sizes and thickness (factory made) sunk in wall where as required and accessories complete including taking down of old unserviceable point wiring and accessories complete all specified and directed by EIC.
30Supply only plug top 16/ 20 Amps, complete all as specified and as directed.
31Supply only bottom split inspection cover of 25 ltr geyser of any make all as specified and directed by Engineer-in-charge.
32Supply in replacement flush type socket, 6/ 16 Amps - 2/3 pin combined 2 module, ISI marked complete all as specified and as directed.
33Supply in replacement switch piano flush type, one way, 16/ 20 Amps, 1 module, ISI marked complete all as specified and as directed.
34Taking down carefully copper/aluminium point wiring (light/fan/socket/power socket ) complete including taking out existing unserviceable terminal boxes and conduit with switches/sockets/fan regulators and fitting such as ceiling rose, pendant tube light fittings, lamp holder, brackets light fittings, rectangular blocks etc and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed.
35Supply and fixing to walls/laid in floors CPVC pipes 15 mm of pressure rating 6kgf/sq cm including pipe fittings viz tee, sockets bends, elbow, union, nipple etc with screwed and socketed joints complete all as specified and directed Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57831990
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 25 Lakhs
LAST DATE 22-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maintenance Of Geysers And Connected Items For Md Accn And Otm Accn At Hisar Mil Stn Under Ge Hisar
Basic Detail
Tender No GE(H)-35/2026-27
Bidding Type Tender
Location
City Hisar
State Haryana
Key Dates
Publish Date 01 Oct 2026
Submission Date 22 Oct 2026
Open Date 24 Oct 2026
Finance
Tender Value 25 Lakhs
Tender Fee 500
EMD 50000
Exemption Available
Document List
9e327d51-eef2-4f4c-8c80-1af6ae164333.html
BOQ_888046.xls
TENDERGE35.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Oct 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

9e327d51-eef2-4f4c-8c80-1af6ae164333.html

xls

BOQ_888046.xls

pdf

TENDERGE35.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders