Defence Statutory Bodies & Commissions/Committees Closing in 2 days TDR #57831978

Tender For Repair / Maintenance Of Lt Panels, Mccbs And Connected Works At Rowriah, Saraibari And Bhalukmara Under Ge Jorhat.

Issued by Statutory Bodies & Commissions/Committees · Jorhat, Assam
Tender Value
48 Lakhs
Estimated cost
Bid Submission
29 Oct 2026
2 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jorhat → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance Of Lt Panels, Mccbs And Connected Works At Rowriah, Saraibari And Bhalukmara Under Ge Jorhat.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 22-Oct-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 29-Oct-2026

BOQ

Name of Work:- REPAIR / MAINT OF LT PANELS, MCCBs AND CONNECTED WORKS AT ROWRIAH, SARAIBARI AND BHALUKMARA UNDER GE JORHAT.
Sl. No. Item Description
1NOTE:-(i) The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.(ii) It is highlighted that the certain condition of General Condition of Contracts (IAFW-2249) has been modified as per direction of MoD i.e. inclusssion of Performance Security, deletion of Risk & Cost Provisions and increase in defect liability period all as per tender documents. The tenderers should keep in mind while quoting their offer. (iii) (Applicable for all items/parts):- The bidders/contractors are advised to refer Notes on BOQ/SCH'A' before entry/quoting the rates.
2Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 6 Sqmm 2 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed.
3Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 10 Sqmm 2 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed.
4Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 10 Sqmm 4 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed.
5Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 16 Sqmm 4 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed.
6Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 25 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc.and replaement of old unserviceable cable complete all as specified and as directed.
7Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 35 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed.
8Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 50 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed.
9Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 70 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed.
10Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 95 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed.
11Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 120 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed.
12Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 150 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc. and replaement of old unserviceable cable complete all as specified and as directed.
13Supply and fixing as in replacement for LT 1.1 KV (Earthed) grade heat shrinkable end termination jointing kit straight through type complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 10 to 16 sqmm complete all as specified and as directed.
14Supply and fixing as in replacement for LT 1.1 KV (Earthed) grade heat shrinkable end termination jointing kit straight through type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 to 50 sqmm complete all as specified and as directed.
15Supply and fixing as in replacement for LT 1.1 KV (Earthed) grade heat shrinkable end termination jointing kit straight through type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 150 sqmm complete all as specified and as directed.
16Material and labour for HDPE pipe of pressure rating 10 kgf/cm² and dia 75 mm for passing of cable through PCC foundation from trench to distribution board with necessary clamp nuts and bolts complete all as specified and as directed.
17Supply and laying GI tubing 40mm bore light grade with fittings laid in trenches or for road crossing for protection of LT underground cables including taking up old unserviceable pipe complete all as specified and as directed.
18Supply and laying GI tubing 80mm bore light grade with fittings laid in trenches or for road crossing for protection of LT underground cables including taking up old unserviceable pipe complete all as specified and as directed.
19Supply and laying GI tubing 100mm bore light grade with fittings laid in trenches or for road crossing for protection of LT underground cables including taking up old unserviceable pipe complete all as specified and as directed.
20Labour only for boring of hole under roads with mechanical arrangement upto 100 mm dia without disturbing the top surface of the road for passing the cable across the road complete all as specified and as directed.
21Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 400 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 36 KA including making incoming and outgoing connections complete all as specified and as directed.
22Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 350 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 36 KA including making incoming and outgoing connections complete all as specified and as directed.
23Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 250 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 25 KA including making incoming and outgoing connections complete all as specified and as directed.
24Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 200 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 25 KA including making incoming and outgoing connections complete all as specified and as directed.
25Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 160 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 18 KA including making incoming and outgoing connections complete all as specified and as directed.
26Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 125 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections complete all as specified and as directed.
27Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 100 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections complete all as specified and as directed.
28Supply and fixing as in replacement MCCB triple pole and neutral (Four pole) 63 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections complete all as specified and as directed.
29Supply and fixing as in replacement steel tubular swaged poles, type 410 SP-31 (Overall length 9.00 meter) conforming to IS-2713 (Part 1 to 3) 1980 complete with cast iron base plate, finial taper plug, bolts, nuts and washers, screws. Pole shall be painted with two coat of black bituminous throughout internally and externally upto planting depth and the remaining external portion shall be painted with two coats of aluminum paints over a coat of red oxide primer, painting black & white alternate strips of 30cm each externally from ground level upto 1.2m with synthetic enamel paint, numbering of poles complete all as specified and as directed.Note: Excavation and earth work and PCC shall be measured and paid separately under respective items.
30Supply and fixing as in replacement of Danger notice boards/plate of size 200 mm x 150 mm x 1.6 mm thick, mild steel sheet, vitreous enamelled white with letters 440 Volt, figures and conventional skull and bones in signal red colour and fixed with and including MS clamps made out of MS Flat 25 x 3 mm, bolts and nuts of approved size for LT poles/panels complete all as specified and as directed.
31Supply and fixing as in replacement of Danger notice boards/plate of size 250 mm x 200 mm x 1.6 mm thick, mild steel sheet, vitreous enamelled white with letters (1100 Volt)/11 KV, figures and conventional skull and bones in signal red colour and fixed with and including MS clamps made out of MS Flat 25 x 3 mm, bolts and nuts of approved size for HT poles / panels complete all as specified and as directed.
32Materials and labour as in replacement for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed.
33Materials and labour as in replacement for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip 32x6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed.
34Supply and fixing Galvanised Iron Strip 32 × 6 mm with saddles and fixing screws for roof/earth running and down conductors above ground including taking down unserviceable strip complete all as specified and as directed.
35Supply and fixing Aluminium Strip 25 × 3.15 mm with saddles and fixing screws for roof/earth running and down conductors above ground including taking down unserviceable strip complete all as specified and as directed.
36Materials and labour for trimming of branches of trees touching LT electric over head line and making clear about 3 mtr in radius by climbing up tree or by providing ladder, at a height 7 mtr and above and carrying and depositing where directed not exceeding 50 mtr complete all as specified and directed. Note:-One span of 2 to10 no conductors in one pole to another pole consider as per one span.
37Cutting, trimming and prunning of trees/tree branches/creepers/climbers of all around existing LT panels including cleaning the disturbed area beneath the LT junction boxes and removing the tree branches and debris from site and depositing complete all as specified and as directed.
38Supply and fixing as in replacement on-load change over switch 04 pole of capacity 200Amps - 415 Volts with SS enclosure complete all as specified and as directed.
39Supply and fixing as in replacement on-load change over switch 04 pole of capacity 160Amps - 415 Volts with SS enclosure complete all as specified and as directed.
40Supply and fixing as in replacement on-load change over switch 04 pole of capacity 125Amps - 415 Volts with SS enclosure complete all as specified and as directed.
41Supply and fixing as in replacement on-load change over switch 04 pole of capacity 63Amps - 415 Volts with SS enclosure complete all as specified and as directed.
42Supply and laying in replacement of synthetic insulating fiber mat of size 2m x 1m x 3 mm thick for HT/LT Panel/Feeder pillar boxes etc complete all as specified and as directed.
43Supply and fixing in replacement of 3 Ph LED Ammeter Cl1 for LT Panel, flush mounting 96x96 mm with inbuilt selector switch complete all as specified and as directed.
44Supply and fixing in replacement of 3 Ph LED Voltmeter for LT Panel suitable for input voltage measurement range 50-550 VAC, flush mounting 96x96 mm with inbuilt selector switch complete all as specified and as directed.
45Supply and fixing in replacement of ammeter selector switches for line current with off with CT complete all as specified and as directed.
46Supply and fixing in replacement of voltmeter selector switches for voltage between phases with OFF complete all as specified and as directed.
47Supply and fixing in replacement of R-Y-B LED indicators(set of three) having 16mm dia with LVGP and Surge Protection complete all as specified and as directed.
48Supply and fixing in replacement of 4 pole power contactors, type MCX21, suitable for 80 Amps AC rating complete all as specified and as directed.
49Material and labour for disconnecting and taking down existing LT panel of any size, raising and re-fixing the same to a height of 0.70 to 1.00 m above finished floor level by providing suitable angle iron/MS structural supports or PCC pedestal/base, including necessary cutting, welding, fabrication and anchoring works, reconnection of existing cables/wiring and earthing as required, minor denting, patch repair and welding of panel/enclosure, complete with cleaning and preparation of all internal and external surfaces by wire brushing/scraping and fine sand papering, removing loose/old paint, rust, dirt and scale, making surface smooth, applying two coats of approved super synthetic enamel paint by brush or spray over suitable primer, protecting/removing paint from glass, rubber and other fittings, and all necessary tools, plant and tackles, complete all as specified and as directed.Note: Rate included Excavation, PCC and complete connected works.
50Material and labour for isolating, disconnecting and taking down existing HT and LT cables/connections from transformer of any capacity, including complete electrical isolation, removal of connections, lifting and lowering of transformer by suitable lifting arrangement, construction of raised brick masonry plinth/platform of approximately 1.50 m × 1.50 m plan size and 1.00 m height, including necessary PCC/RCC foundation, brick masonry, cement mortar, plastering/finishing and allied masonry works as required, curing and making platform suitable to sustain transformer load, including lifting and re-fixing the transformer on the newly constructed raised platform, alignment, reconnection of HT/LT cables, earthing and other associated connections, testing and commissioning, including all necessary tools, plant, tackles and safety arrangements, complete all as specified and as directed.
51Supply and fixing in replacement of MCCB enclosure DB, Frame-1 type, suitable for 415 V, 3-phase, 50 Hz AC supply, of approved make and construction, complete with mounting arrangement, busbar/chamber as required, cable entry provisions, gland plates, earthing terminals, required hardware and all necessary accessories complete all as specified and directed.
52Supply and fixing in replacement of MCCB enclosure DB, Frame-2 type, suitable for 415 V, 3-phase, 50 Hz AC supply, of approved make and construction, complete with mounting arrangement, busbar/chamber as required, cable entry provisions, gland plates, earthing terminals, required hardware and all necessary accessories complete all as specified and directed.
53Supply and fixing in replacement of MCCB enclosure DB, Frame-3 type, suitable for 415 V, 3-phase, 50 Hz AC supply, of approved make and construction, complete with mounting arrangement, busbar/chamber as required, cable entry provisions, gland plates, earthing terminals, required hardware and all necessary accessories complete all as specified and directed. Please Enable Macros to View BoQ information
54Supply and fixing in replacement of MCCB enclosure DB, Frame-3 type, suitable for 415 V, 3-phase, 50 Hz AC supply, of approved make and construction, complete with mounting arrangement, busbar/chamber as required, cable entry provisions, gland plates, earthing terminals, required hardware and all necessary accessories complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57831978
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48 Lakhs
LAST DATE 29-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance Of Lt Panels, Mccbs And Connected Works At Rowriah, Saraibari And Bhalukmara Under Ge Jorhat.
Basic Detail
Tender No 8365/GE/E8
Bidding Type Tender
Location
City Jorhat
State Assam
Key Dates
Publish Date 22 Oct 2026
Submission Date 29 Oct 2026
Open Date 03 Nov 2026
Finance
Tender Value 48 Lakhs
Tender Fee 500
EMD 96000
Exemption Available
Document List
822ab41a-a598-4889-bc62-f29d06086638.html
BOQ_887105.xls
Tendernotice_1.pdf
Tender_8365.rar

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 29, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 2 days
Oct 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Nov 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

822ab41a-a598-4889-bc62-f29d06086638.html

xls

BOQ_887105.xls

pdf

Tendernotice_1.pdf

rar

Tender_8365.rar

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender