Tender For Repairs To Boundary Wall, Drain, Fencing, Gate, Pathways, Sewage Lines & Septic Tanks & Attending Complaints Mm Rd, Arjun Marg, Kohima Line, Pg Rd, Comd Mt, Shivnery C , Milkha Singh, 752 Tpt Coy, Ssag, Sfc And Other Variour Nearby Locatio
Tender Overview
Project Description
Tender for Repairs To Boundary Wall, Drain, Fencing, Gate, Pathways, Sewage Lines & Septic Tanks & Attending Complaints Mm Rd, Arjun Marg, Kohima Line, Pg Rd, Comd Mt, Shivnery C , Milkha Singh, 752 Tpt Coy, Ssag, Sfc And Other Variour Nearby Locations In The Area Of Age B/R (Central) Under Ge (N) Pune.
BOQ
| Sl. No. | Item Description |
| 1 | Demolition Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 2 | Demolition of brick work / stone masonry / block masonry built in built in cement mortar or cement lime mortar complete all as specified and as directed. |
| 3 | Dismantling plain or corrugated steel/asbestos sheeting , any gauge or any thickness, as in roof coverings complete all as specified and as directed. |
| 4 | Dismantiling chain link fencing wire mesh of any type complete all as specified and as directed. |
| 5 | Dismantiling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 6 | Taking Down Old RCC Louvered Jalli/ Jaffery without harming the exisiting wall of Stone/ Block or Bricks masonry complete all as specified and directed. |
| 7 | Taking down cement plaster on brick/ stone walling including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 8 | Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 m in depth for foundation, cable etc. or for shafts, wells, cesspits, manholes, pier holes, pole etc. n. exc 10 sq m on plan and getting out in hard/ dense soil complete all as specified and as directed. |
| 9 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick with soils complete all as specified and as directed. |
| 10 | Removing of excavated material (soil) to distance exceeding 1.5Km and not exc. 5Km and deposited where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed. |
| 11 | M&L in repair for 150mm bore RCC pipes, class NP-2 laid and jointed with collars and tested including demolition and breaking up 150mm bore dia drain pipes (salt glazed earthern ware, AC or reinforced concrete), set in cement mortar complete all as specified and as directed. |
| 12 | M&L in repair for 200mm bore RCC pipes, class NP-2 laid and jointed with collars and tested including demolition and breaking up 200mm bore dia drain pipes (salt glazed earthern ware, AC or reinforced concrete), set in cement mortar complete all as specified and as directed. |
| 13 | M&L in repair for 300mm bore RCC pipes, class NP-2 laid and jointed with collars and tested including demolition and breaking up 300mm bore dia drain pipes (salt glazed earthern ware, AC or reinforced concrete), set in cement mortar complete all as specified and as directed. |
| 14 | M&L for PCC (1:3:6) type C2 ( using 40mm graded broken stone aggregates) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore of pipe including demolition of existing PCC complete all as specified and as directed. |
| 15 | M&L for PCC (1:3:6) type C2 ( using 40mm graded broken stone aggregates) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200mm bore of pipe including demolition of existing PCC complete all as specified and as directed. |
| 16 | M&L for PCC (1:3:6) type C2 ( using 40mm graded broken stone aggregates) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 300 mm bore of pipe including demolition of existing PCC complete all as specified and as directed. |
| 17 | M&L for Cement concrete (1:2:4) type B-1 (using 20 mm graded broken stone aggregate) as in coping, benching, bed blocks, lintels upto 1.5m clear span and including weathering, slightly rounded or chamfered angles and throating, using necessary form work including demolition of existing concrete all as specified and as directed. |
| 18 | M&L for PCC (1:2:4) type B1 (using 20mm graded broken stone aggregates) as in surface channel and drain including demolition of existing concrete complete all as specified and as directed. |
| 19 | M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC (1:2:4) type B-1, smooth finished and reforming benching as required for 150 mm internal dia of pipe complete all as specified and as directed. |
| 20 | M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC (1:2:4) type B-1, smooth finished and reforming benching as required for 200 mm internal dia of pipe complete all as specified and as directed. |
| 21 | M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC (1:2:4) type B-1, smooth finished and reforming benching as required for 300 mm internal dia of pipe complete all as specified and as directed. |
| 22 | S&F Precast RCC manhole cover include frame, 50mm thick light duty factory made with IS code-12592:2002 specification and fixed properly over manhole on new/old and set in CM 1:4 and handles including demolition of existing RCC cover (reinforcement cut as required to facilitate demolition) of any description and in any position complete all as specified and as directed. |
| 23 | M&L in repair for precast cement concrete 1:2:4 type B1 (using 20mm graded stone aggregates) as in landings, cover slab (for manholes), shelves & similar articles with plan faces & set in CM 1:4 complete all as specified and directed. |
| 24 | M&L for mild steel TMT bars 6 mm to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed. |
| 25 | Taking out semi solid, liquid suspension sludge and foreign material from man hole/ septic tanks/ soakage well of any description and any depth including sucking/ pumping of water by honey sucker with pump set and removing and refixing of acessories and appliances required for safe disposal of sludge and foreign materials either by carrying the same in covered van or trolley at out side MOD land and burring the same (semi solid/ liquid shall not be burried) in ground complete all as specified and as directed. (Note: Disposal of foreign material to be disposed of outside of MoD land as directed by Engr-in-charge). Note: (i) Measurement shall be actual plane area X 1/2 total depth of septic tank (ii) Complete solid, liquid & sludge shall be removed (iii) Complaint should be obtained every day from complaint cell /JE by Contractor / rep of Contractor. (iv) Disposal of complaints should be within 36 Hrs from date of receipt of complaints. |
| 26 | Cleaning of manhole of any size by removing solids,semi solids,sludge and any type of foreign materials with manual/ mechanical means and disposal of taken down items outside the MD land complete all as specified and as directed. (Note: (i) Measurement of solid shall be taken before dispose of material outside MD land. (ii) Complaint should be obtained every day from complaint cell /JE by Contractor / rep of Contractor.(iii) Disposal of complaints should be within 36 Hrs from date of receipt of complaints. |
| 27 | Cleaning/clearing & Maintanance of sewage lines including CI/PVC/SGSW/RCC stacks, incl under ground sewage lines any depth by removing any type of blockage from sewage drain upto and including 100mm bore/ dia by rodding or any other means from manholes to manholes including plugging of manholes temporarily as and when required and flushing with water after cleaning including intermediate manholes. Sludge/sludge water in form of semi solid/loose state will be disposed off either by carrying the same in covered van or trolley at out side MOD land and burring the same (semi solid/ liquid shall not be burried) including taking off manhole covers and refixing the same after cleaning. The operation shall be executed/carried out with any kind of sewage cleaning device such as sewage cleaning Mechanical Pump / Vehical and cost of same shall be deemed to be included in the rate quoted by the contractor.Note:(i) Complaint should be obtained every day from complaint cell /JE by Contractor / rep of Contractor.(ii) Disposal of complaints should be within 36 Hrs from date of receipt of complaints. |
| 28 | Cleaning/clearing & Maintanance of sewage lines including CI/PVC/SGSW/RCC stacks, incl under ground sewage lines any depth by removing any type of blockage from sewage drain exceeding 150mm and not exceeding 200mm bore/ dia by rodding or any other means from manholes to manholes including plugging of manholes temporarily as and when required and flushing with water after cleaning including intermediate manholes. Sludge/sludge water in form of semi solid/loose state will be disposed off either by carrying the same in covered van or trolley at out side MOD land and burring the same (semi solid/ liquid shall not be burried) including taking off manhole covers and refixing the same after cleaning. The operation shall be executed/carried out with any kind of sewage cleaning device such as sewage cleaning Mechanical Pump / Vehical and cost of same shall be deemed to be included in the rate quoted by the contractor.Note:(i) Complaint should be obtained every day from complaint cell /JE by Contractor / rep of Contractor.(ii) Disposal of complaints should be within 36 Hrs from date of receipt of complaints |
| 29 | Cleaning/clearing & Maintanance of sewage lines including CI/PVC/SGSW/RCC stacks, incl under ground sewage lines any depth by removing any type of blockage from sewage drain exceeding 200mm and not exceeding 300mm bore/ dia by rodding or any other means from manholes to manholes including plugging of manholes temporarily as and when required and flushing with water after cleaning including intermediate manholes. Sludge/sludge water in form of semi solid/loose state will be disposed off either by carrying the same in covered van or trolley at out side MOD land and burring the same (semi solid/ liquid shall not be burried) including taking off manhole covers and refixing the same after cleaning. The operation shall be executed/carried out with any kind of sewage cleaning device such as sewage cleaning Mechanical Pump / Vehical and cost of same shall be deemed to be included in the rate quoted by the contractor.Note:(i) Complaint should be obtained every day from complaint cell /JE by Contractor / rep of Contractor.(ii) Disposal of complaints should be within 36 Hrs from date of receipt of complaints |
| 30 | Cleaning of blocked WC/gully trap/ Floor trap, upto and including first manhole by manual labour as well flushing with clean water making the WC seat , gully trap, floor trap operational complete all as specified and directed by Enge-in-ChargeNote:(i) Complaint should be obtained every day from complaint cell /JE by Contractor / rep of Contractor.(ii) Disposal of complaints should be within 36 Hrs from date of receipt of complaints |
| 31 | Cleaning/clearing & Maintanance of sewage lines including CI/PVC/SGSW/RCC stacks, incl under ground sewage lines any depth or any dia using pressure jet machine complete all as specified and directed by Enge-in-Charge. |
| 32 | S&F in repair PVC (SWR) pipe 75mm bore single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed. |
| 33 | S&F in repair PVC (SWR) pipe 110mm bore single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed. |
| 34 | S&F in repair PVC (SWR) pipe 75mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed. |
| 35 | S&F in repair PVC (SWR) pipe 110mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed. |
| 36 | S&F in repair PVC (SWR) bends any radius of 75mm bore complete all as specified and as directed. |
| 37 | S&F in repair PVC (SWR) bends any radius of 110mm bore complete all as specified and as directed. |
| 38 | S&F in repair PVC (SWR) branch piece, single Y, equal or unequal for 75mm bore pipe complete all as specified and as directed. |
| 39 | S&F in repair PVC (SWR) vent cowl for 110 mm bore pipe complete all as specified and as directed. |
| 40 | S&F in repair cast iron nahani/floor trap, 75mm dia of outlet, with grating including joining to waste pipe fixed in PCC (1:2:4) type B-1 (using 20mm graded broken stone aggregates) complete all as specified and as directed. |
| 41 | M&L in repair PVC (SWR) gully trap 125/ 110 setting and jointing with solvent cement complete all as specified and as directed. |
| 42 | M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate.) as in foundation filling & mass concrete, bed of manholes etc. complete all as specified and directed. |
| 43 | M&L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick or concrete surfaces finished even and smooth without using extra cement all as specified as directed. |
| 44 | S & F of rolled mild steel in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc,; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde e-165, complete all as specified and directed |
| 45 | M&L for mild steel framed work such as grill, grating, gate etc with ends of bars shouldered or rebated or forged into spike framed guard bars barred iron doors, ladders, framed baluster, walk way, railing; frame work, including pintle hinges, stops, hand-made sliding bolts etc,sliding channels for sliding of gate and similar work conforming to Fe 290 Gde-E-165 complete all as specified & as directed. |
| 46 | S&F mild steel rolled section as in main cross beams purlins, rafters and running rails fixed independently with angle iron cleats or connecting pieces conforming to Gde Fe-410-W, Gde E-250, quality A complete all as specified and directed. |
| 47 | S&F mild steel work in tubular trusses including special shaped washer etc. complete using hollow mild steel sections round, square or rectangular for structural use as in main and cross beams, hip and jack rafters, purlins conforming to IS 4923:1997 fixed with angle cleats or other connecting plates complete all as specified and as directed. |
| 48 | M&L for preparation of old painted steel surfaces of any description over 10 cm girth or width and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 49 | M&L two coats of synthetic enamel paint on new steel surfaces over a coat of red oxide primer surfaces of any description exc 10 cm in witdth or girth complete all as specified and as directed. |
| 50 | M&L Granite (of any type) work (table rubbed and polished) of 20mm thick in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 15mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 51 | M & L stone walling of Random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and as directed. |
| 52 | All as per Srl item No. 51 above but except stones |
| 53 | M&L for Flush pointing to block in course or ashlar masonry or concrete block walling in cement mortar 1:3 including raking out joints complete all as specified and as directed |
| 54 | M&L Brick work with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 etc including demolition of brickwork built in cement mortar complete all as specified and directed. |
| 55 | M&L for Pre-cast cement concrete block masonry with solid blocks type C1, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and directed |
| 56 | M&L for preparation of newly plastered surfaces and applying two coats of weather proof exterior emulsion paint ('APEX' brand of Asian or equivalent brand of Berger/Shalimar) over one coat of primer to wall complete all as specified and as directed by Engineer-in-charge. |
| 57 | Use and waste for formwork to sides and soffits of floor or roof beams, coping, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed |
| 58 | M&L for RCC (Nominal mix)1:2:4, type B1 as in columns, pillars, piers,posts and struts complete all as specified and as directed. |
| 59 | S & F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 60 | All as per tem No 59 above but 6-8mm dia stirrups |
| 61 | M & L precast cement concrete Type B0 1:2:4 (12.5mm graded aggregate) louvres and jallies, 40 mm thick (measured solid), in cluding all mould- ings complete all as specified and directed |
| 62 | Excavating in post holes in hard/dence each n exc 0.5 cum, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed. |
| 63 | S & F fibre glass reinforced translucent corrugat/plain sheeting with two corrugations side lap fixed with coach screw andwasher in roof, wall etc complete all as specified and directed |
| 64 | S&F polycarbonate fibre glass reinforced translucent corrugated sheeting 6.00 mm thick hollow section fixed with coach screw and washer in roof, wall etc. complete all as specified and as directed. |
| 65 | M & L 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc. complete all as specified and directed |
| 66 | S&F in repair for 6mm thick asbestos cement, two piece adjustable serrated ridge for corrugated or semi corrugated sheets fixed with L-type or J-type or cranked hook bolts etc. complete all as specified and as directed. |
| 67 | S&F Plain, galvanised, mild steel sheeting,0.63mm in ridges, hips, valley gutters, drip and straight flashings (length and girth asfixed) with grade of zinc coating 275 complete all as specified and directed |
| 68 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed |
| 69 | M & L for Machine pressed precast concrete interlocking paver block with gray cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade complete all as specified and as directed |
| 70 | Fixing only interlocking tile of any thickness and size including 30mm thick sand cushoning complete all as spcified and directed. |
| 71 | M&L textured heavy duty parking tile of size 300mm X 300mmX10mm thick , set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including a screed bed in CM 1:4 all as specified. Make :- Jonhson endura textured design or equivalent of kajaria/ somany. |
| 72 | M&L for 25mm thick coloured glossy rubber moulded chequered cement concrete tiles with grey cement & pigment of area exc. 0.08 Sqm and n.exc 0.16sqm each, set, jointed and pointed in net cement slurry mixed with grey cement and pigment in floors including 15 mm thick screed bed or bedding layer of cement mortar (1:6) for laying floor finishes including dismantling of existing complete all as specified and as directed. |
| 73 | M & L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 74 | M & L 75 mm thick cement concrete (1:4:8) type D2 (using 40mm grade broken stone aggregate) as in sub base complete all as specified and as directed. |
| 75 | M&L for Filleting in any position and to any shape in cement mortar 1:4 exc.25 but n exc.50 sq.cm including all mitres, stops, etc. complete all as specified and as directed. |
| 76 | M&L for wall cladding tiles 600 mm x 300 mm and 7 to 8 mm thick as in wall cladding, set and jointed in grey cement paste and pointed in coloured cement or with mixture of white cement and pigment to match colour of tiles complete all as specified and as directed.Make : RAK or Techno commercially equivalent in approved makes |
| 77 | M&L for preparation of old surfaces and applying two coats of weather proof exterior emulsion paint ('APEX' brand of Asian or equivalent brand of Berger/Shalimar) on wall complete all as specified and as directed by Engineer-in-charge. |
| 78 | M&L in repair for concentina punch type wire 610 mm dia of each coil avg weight n less than 1.06 kg/RM after stretching including coating of anti rust compound fixed on angle iron bracktes top of compound wall complete all as speified and directed. |
| 79 | S&F in repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as speified and directed. |
| 80 | Supply Chain link MS galvanisd fencing, any size or type complete all as specified and as directed. |
| 81 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and as directed. |
| 82 | S&F MS Screw bolts ( machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut but length of bolt exc 25mm but n exc 50mm long, dia of 5 to 10 mm dia of neck all as specified. |
| 83 | M&L for round bars 10mm dia and over cut to length& fixed as in straining bars for stiffining chainlink fence all as specified and directed. |
| 84 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed |
| 85 | M & L for preparation of new/old concrete surfaces/kerb stone of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed. |
| 86 | M&L 75mm thick PCC (1:3:6) type C2 (using 40mm graded broken stone aggregate) as in plinth protection/court yard finishing the surface even and smooth without using extra cement including demolition of existing complete all as specified and as directed. |
| 87 | Note : 1. Performance security:- Refer Condition 22 of Special Conditions. 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender