Tender For special Repair To Building No P-216 And P-219 Of Certain Units At Mil Stn Jamnagar Under Ge(A) Jamnagar.
Tender Overview
Project Description
Tender for special Repair To Building No P-216 And P-219 Of Certain Units At Mil Stn Jamnagar Under Ge(A) Jamnagar.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-Oct-2026 | AMENDMENT TO BOQ | BOQ | 22-Oct-2026 |
| 2 | 22-Oct-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 29-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down cement plaster on brick or concrete surfaces including racking out joints hacking for keys scrubbing down with water etc complete all as specified and as directed. |
| 2 | Dismantaling floor, hearth or wall tiling including cement mortar bedding(but not backing) removing servicable tiles to store and rubbish off premises complete all as specified and as directed. |
| 3 | Taking down Chowkats or Frames, not exc. 1.50 Sqm Each with Shutters (without Taking Off Shutters from the Frames), complete all as specified and as directed. |
| 4 | Taking down shutter of any description exc 1 sqm but n exc 2 sqm complete all as specified and as directed. |
| 5 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and as directed. |
| 6 | Demolition Cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 7 | Demolition of brick work or stone/boulder masonary built in CM including all quoins, arches, pillars, etc but excluding ashlar, facing, dressed stone work and pre-cast concrete articles complete all as specified and as directed by Engineer-in-Charge |
| 8 | Rendering 10mm thick on fair faces on brick masonary or concrete surfaces in cm 1:6 finished complete all as specified and as directed. |
| 9 | M&L 15 mm thick rendering on other than fair faces of external wall of brick/ stone / block masonary or concret surfaces in two layers Ist layer shall be 10mm in cm 1:6, secound and final layer shall be 5mm thick in CM 1:4 finished fair and even without using extra cement mixed with integral water proofing compound complete all as specified and as directed. |
| 10 | M&L Prepration of newly plastered surface of wall by hand held sander / long handle sander including cornices, pilasters etc and appliying with Airless spray two or more coats of 100 % premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (company Depot Tinted) with silicon additives @1.43 litre/10Sqm over and including priming coat of exterior primer applied @ 0.9 ltr/10sqm complete all as specified and as directed. |
| 11 | M&L for Prepration by hand held sander / long handle sander including cornices, pilasters etc of newly plastered on wall complete and applying three coat of white wash, complete as specified. |
| 12 | M&L for Prepration by hand held sander / long handle sander including cornices, pilasters etc of old plastered wall complete and applying one coat of white wash, complete all as specified and as directed. |
| 13 | M&L complete removal of existing tretment by hand held sander / long handle sander washing down with Jet washer and appliying Airless spray two or more coats of 100 % premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (company Depot Tinted) with silicon additives @1.43 litre/10Sqm over and including priming coat of exterior primer applied @ 0.9 ltr/10sqm complete all as specified and as directed. |
| 14 | S & F PVC door with chowkhats frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supply & fixing in opening as per specification & drawing. |
| 15 | S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete, all as specified & directed. |
| 16 | Providing cement concrete type BO 1:2:4 (12.5mm graded aggregate) in cills, steps, seismic and other similar bands plinth coureses string courses lacing courses parapets and railing copings kneelers apex bed plates kerbs. etc. water troughs and the like including wethering slightly rounded or chamfered angles and throating complete all as specified and as directed. |
| 17 | S&F for 35 mm thick flush shutters, solid core construction with block board core and plywood face panels, commercial type on both sides and fitted to chowkhats , side of door is covered from 3 side with external teak wood lipping complete all as specified and directed. |
| 18 | S&F powder coated anodised aluminium alloy sections 3 tier track sliding windows series B of size 92mm x 31.75mm x 1.2mm and shutter section 18mm x 43mm x 1.30mm weight 0.547 kg/m Jindal or equivalent duly fitted with neoprene beading, glazing clips, tinted glass panes 4.80/5.0 mm nominal thickness, stainless steel wire cloth 0.36 mm dia and average width of aperture 1.4 mm, aluminium alloy handles etc including taking down old window in any size and make. complete all as specified and directed.Note : Rate shall include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangements, handle etc |
| 19 | S&F powder coated anodised aluminium fixed louvered ventilator frame of size 63.5 x 38.1 x 1.01 mm thick or equivalent section fixed in vertical position with aluminium vertical members and half portion to be provided with 4 mm thick pinhead glass and remaining portion to be louvered using 4 mm thick pinhead glass and louvered portion covered with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm incl necessary channel frame work, including rubber gasket and aluminium beading including taking down old ventilator in any size and make complete all as specifiedNote : rates shall include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading etc |
| 20 | S & F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 21 | M&L for preparation of old steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint upto 10 mtr height complete all as specified and directed. |
| 22 | M/L two coats of synthetic enameled painting over a coat of pink primer to new wooden surfaces of any description exc 10 cm width or girth complete all as specified and as directed. |
| 23 | S&F Mild Steel Butt hinges, heavy weight, cold rolled, of size 100 mm complete all as specified and directed. |
| 24 | S&F aluminium anodised, barrel tower bolt of extruded section 100mm long, complete all as specified and as directed. |
| 25 | S&F 100 mm long aluminium handle, cast type, anodised complete all as specified and as directed. |
| 26 | S&F aluminium alloy anodised sliding door bolt with hasp staple(bolt type) ,250 mm long,and fixing clip of sheet cast or extruded section or fixing bolt cast aluminium alloy and fixed complete all as specified and as directed. |
| 27 | M&L for screed bed or bedding 15mm thick in CM 1:4 on floor to receive tile complete all as specified and as directed. |
| 28 | S & F Non Skid Ceramic Colour Tiles 7 to 8 mm thick area of each tiles exc 0.06 Sqm but n. exc 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 29 | S & F vitrified tiles 8 to 10 mm thick area of each tiles n exc 0.36 Sqm in floor , skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 30 | M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 20mm screed bed in CM 1:4 complete all as specified and as directed. |
| 31 | M&L rendering 10 mm thick in CM 1:3 finish fair and even on wall to receive tile complete all as specified and as directed. |
| 32 | M& L glazed ceramic coloured tile in vertical surfaces 300x450x7 mm thick set and jointed in neat cement slurry and poited in white or coloured cement to match complete all as specified and as directed. |
| 33 | M&L for 75mm thick cement concrete Type C-2 ,1:3:6,( Using 40mm graded aggregate) as in plinth protection , subbase complete all as specified and directed by Engr-in-charge. |
| 34 | Taking up or down steel tubing and connections including bore of pipe 25 mm complete all as specified and as directed. |
| 35 | Supplying and laying of 25 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape in any requirement complete to walls and ceilings or laid in floors including all connected brass cpvc fittings, female brass threaded adaptor and cutting grooves, filled with CM1:6 complete all as specified. |
| 36 | Dismantling exc 250 & n exc 500 ltrs water tanks and removing from site complete all as specified and as directed. |
| 37 | S & F 500 liters rotaional moulded polyethylene water storage tank, double layered (cylindrical vertical with closed top cover) as per IS-12701-1996 and PTMT 20mm ball valves/ float valve high pressure with epoxy aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weight 20mm - 210 gms) , hoisted and fixed in position including necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc, complete as specified in SSR Part-I complete all as directed by Engr -in-charge. |
| 38 | S&F in repairs 20 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe/upvc pipe complete all as specified and as directed. |
| 39 | S&F in repair fancy type Bib taps, cast copper alloy 15mm dia with long handle, screwed down, screwed for iron pipe incl female brass threaded adaptor on CPVC pipes complete all as specified and as directed. |
| 40 | S&F in repair Fancy type Stop valves angle /concealed 15mm bore, cast copper alloy, screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed incl female brass threaded adaptor on CPVC pipes complete all as specified |
| 41 | S&F in repair 15mm fancy type Pillar taps, cast copper alloy, with long heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed. |
| 42 | S&F PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and as directed. |
| 43 | S&F in repairs PVC(SWR) pipe 110 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, fixed to wall complete all as specified and as directed. |
| 44 | S & F PVC (SWR) junction single (single T) equal or unequal 110mm bore, with access door complete all as specified and directed by Engr-in-charge. |
| 45 | S&F in repairs PVC(SWR) pipe 75 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, laid in trenches complete all as specified and as directed. |
| 46 | S&F in repairs PVC(SWR) bend any radius, 75 mm dia complete all as specified and as directed. |
| 47 | S & F PVC (SWR) junction single (single T) equal or unequal 75mm bore, without access door complete all as specified and directed by Engr-in-charge. |
| 48 | M&L for cement concrete 1:2:4 type B-0 (using 12.5 mm aggregate) sub base of floors , mass concrete complete all as specified and directed by Engr in charge. |
| 49 | M & L in repairs 75mm outlet dia PVC(SWR) floor trap, plain with grating including jointing with solvent cement all as specified and directed. |
| 50 | S&F in repair vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern ) including provision of cement concrete bedding, connection to trap and to flushing pipe, anti syphonage pipe etc complete making good to floor complete all as directed. |
| 51 | Supply and fixing in repair PVC flushing cistern, white, 10ltr capacity with 32mm dia flush pipe any lenth fixed to water closed complete all as specified and as directed. |
| 52 | S & F in repair Vitreous China wash basin, white, flat back, size 550mm x 400 mm with & including a pair of cast iron brakets embedded in PCC 1:3:6) type C-1 (using 20mm graded stone aggregate), blocks of size 10x7.5x15cm , and 32 mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts,flange end bedded in red lead cement and other end fixed, ( excluding tap ) including PVC Waste coupling of PTMT 32mm dia (half or full threaded) Minimum weight 45gms , washers and Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete as specified and directed by Engr-in-Charge. |
| 53 | S&F in repairs glass corner shelf 300 mm (with ABS Bracket 300x 600) as selected including removing existing shelf,specified and directed by Eng-in-charge.(Make: Prayag,Jaquar,Cera or equivalent) |
| 54 | S&F in repair Soap dish of any type (S/S) approximate size 160x160 fixed to plugs with chromium plated brass screws complete all as specified and as directed. |
| 55 | S&F in repair Brass chromium plated Tublar towel rail 20mm dia D type 60 cm long between flanges complete all as specified and as directed. |
| 56 | S&F 600 x 450mm bevelled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood & fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 57 | S&F in repair 125 mm Brass chromium plated shower rose with or without swivel joints, any size, including fixing to steel pipe or union, complete all as specified and directed. |
| 58 | M&L for racking of cracks upto 5 mm wide ,preparation and crack filling with ready to use crack fiber reinforced filler /chemical based crack fillers by approved manufacturer and filling as per manufacturer instructions in walls,roofs of any type or size complete all as specified and as directed. |
| 59 | Removal of all loose/unsound/bad/damaged concrete or plaster existing RCC structure of slab/beams/walls/chajja by using chesel/hammar .Cut and remove unsound reinforcement bars, wires etc without damaging the sound reinforcement . clean loose rust from bars manually with brush . fixing new supplymentary bars if required,either by tying it with existing bars or by welding on it. Applying eppoxy bonding agent and making good with polymer modified plaster/micro concrete as required thickness over a coat of rust removing alkaline primer and match the finishing to the existing surface in ground floor including formwork complete all as specified and directed. |
| 60 | Supply only of Intergral water proofing compound as per manufactures instruction complete all as specified and as directed. |
| 61 | M&L for Brickwork with fly ash moudular bricks built in CM (1:4) , straight or curved on plan exc 6m mean radius, complete all as specified and directed. |
| 62 | Demolition Cement Concrete (reinforced) in Roofs, floors (other than ground floors), beams, shelfs, staircases, landing, chajjas and similar suspended work complete all as specified and as directed. |
| 63 | M&L RCC 1:2:4 Type B-1 (20mm aggregate) nominal mix as Slabs supported on walls, beams and columns in floors, roofs, etc. complete all as specified and directed by Engr-in-charge. |
| 64 | M&L for Formwork to flat soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engr-in-charge. |
| 65 | S&F Mild steel bars (TMT bars) 10 mm and above, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engr-in-Charge. |
| 66 | Exacavation in trenches not exc 1.5mtr wide and n exc 1.5mtr depth for foundation, manhole etc not exc 10 Sqm on plan including getting out in soft/loose soil in foul smell condition complete all as specified and directed. |
| 67 | S&F in repairs PVC(SWR) pipe 110 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints,laid in trenches or in floors complete all as specified and as directed. |
| 68 | S&F in repair PVC (SWR)110 mm bend bore bends without door complete all as specified and as directed. |
| 69 | M&L for concrete bed to drain pipes for 100mm bore SGSW/PVC SWR drain pipe in cm 1:4:8 type D-2, using 40 mm graded stone aggregate including packing under and haunching against the sides of pipes in foul smell condition complete all as specifed and as directed. |
| 70 | Returning, refiiling including spreading, leveling watering and well ramming in layers not exc 25cm in soft/loose soil complete all as specified and directed. |
| 71 | Removing excavated surplus soil/material not exc 50mtr and depositing where directed at a level not exc 1.5mtr above the starting point complete all as specified and directed. |
| 72 | M & L PCC 1:3:6 type C2 (using 40mm graded stone aggregates) as in sub base, flooring , mass concrete etc complete all as specified and as directed. |
| 73 | M&L for Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed. |
| 74 | Dismantling AC sheet (Corrugated, Semi corrugated etc) as in roofs etc including ridges, complete all as specified & directed. |
| 75 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed . |
| 76 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws, ridges complete all as specified and directed . |
| 77 | M&L for Hardcore of gauge n exc. 63 mm (broken stone or boulders) , deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 78 | S&F in repairs 5.5 mm thick tinted coloured glass, with oil putty, rubber gasket in square n exc 0.5 sq.m in each pane of steel frame complete all as specified and as directed |
| 79 | S&F in repairs for Steel rolling shutters with thickness of lath 1.0 mm, gear operated type with bevelled gear box and and crank handle, without ball bearing, as specified including top cover, an choring rod, hasp and staple and one shop coat of primer; erected in position as indicated complete all as specified and as directed. |
| 80 | M & L PCC 1:4:8 type C2 (using 40mm graded stone aggregates) as in sub base, flooring , mass concrete etc complete all as specified and as directed. |
| 81 | M&L for Cement concrete type B-2 1:2:4 (40 mm graded aggregate) in surface channels , flooring etc complete all as specified and directed |
| 82 | Cutting of construction joints 25 mm deep and 10 mm wide by early entry saw cut using diamond bi cutter of appropriate size, straight and smooth edges. Joint cleaned thoroughly with application o compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil, vegetation and othe debris Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant. Placing of closed cell medium density, crossed linked polyethylene foam backup rod of 12 mm dia, application of bond breake tape on top of back up rod for complete width of the joint and filled with polyurethane based sealan complying with BS-5212, BS 4254 and EN- 141875 2003 with minimum movement accommodation factor (MAF) of +I- 30% having minimum 10 yea r performance guarantee, applying masked tape on the edges of joints and removing the masking tape after filling of sealant as per the method specified by the manufacturer complete as specified and directed |
| 83 | Forming 25 mm width expansion joint in concrete slab for full depth of POC. Early entry saw and subsequent cutting by using diamond bit cutter o appropriate size. straight and smooth edges. Join cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil, vegetation and other debris. The join then filled with pre-molded 25 mm thick compressible polyethylene closed cell type filler board as specified thereafter application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant Placing of closed cell medium density, crossed linked polyethylene foam backup rod of 30 mm dia, over filler board and filled with polyurethane based sealant complying with BS 5212, BS 4254 and EN-141875-2003 with minimum movement accommodation factor (MAF) of+/- 30% having minimum 10 year performance guarantee applying masked tape on the edges of joints and removing the masking tape after filling of sealant as per the method specified by the manufacture complete as specified and directed. |
| 84 | Forming dummy/contraction joint with an initial saw cut of 3 mm soon after the concrete has set, upto a depth of 1 J3rd to 1 /41h the thickness of the slab widening the first saw cut to 6 mm and 24 mm deep by using diamond bit cutter of appropriate size straight and smooth edges Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil vegetation and other debris. Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant. Placing of closed cell, medium density, crossed linked polyethylene foam backup rod of 8 mm dia application of bond breaker tape on top of back up rod for complete width of the joint and filled with polyurethane based sealant complying with BS 5212, BS 4254 and EN-141875-2003 with minimum movement accommodation factor (MAF) OF +/- 30% having minimum 10 year performance guarantee applying masked tape on the edges of joints and removing the masking tape after filling of sealant as per the method specified by the manufacturer complete as specified and directed |
| 85 | S&F in repairs for safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and as directed. |
| 86 | S&F in repairs for ball bearing for rolling shutters complete all as specified and as directed. |
| 87 | M&L steel work in roof trusses (framed)trussed, posts, purlins, crane gantries rails and fastenings and heavy bracket framing (beam, tee, angle channel or flat sections ) including distance pieces cleats etc Fe-410 W (Gde - E-250) quality A complete all as specified and as directed. |
| 88 | M&L for steel work in tubular trusses including special shaped washer etc. complete using ERW or indication butt welded tubes confirming to I.S. 1161-1979 grade St - 240 complete all as specified and as directed. |
| 89 | M&L for Plates (plain or chequered ) channels, square cut or notched (ordinary and counter sunk ) forming holes, without any attachment (Fe 410 - w (GdeE- 250) quality - A) complete all as specified and as directed. |
| 90 | M&L preparation of new untreated Steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome complete all as specified and as directed. |
| 91 | S&F in repairs for Vitreous China half stall type urinal, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe and pvc waste pipe. (Exclusive of fixing supply pipe to flushing cistern, trap ) complete incl taking down all as specified and directed |
| 92 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 93 | Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed by Engr in charge. |
| 94 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surfacecomplete all as specified and directed by Engr-in-Charge. |
| 95 | Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed by Engr-in-Charge. |
| 96 | M & L for One light point controlled by one, one way switch 5 Amps Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by Engr-in-Charge. |
| 97 | Description all as per item No 138 here in before but using One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad complete all as specified and directed by Engr in charge. |
| 98 | Description all as per item No 138 here in before but using One using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as specified and directed by Engr in charge. (power point) |
| 99 | S & F for modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified and directed by Engr in charge. |
| 100 | S & F for modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified and directed by Engr in charge. |
| 101 | S & F for modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed by Engr in charge. |
| 102 | S & F for modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed by Engr in charge. |
| 103 | S & F for ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified and as directed by Engineer-in-Charge. |
| 104 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed by Engineer-in-Charge. |
| 105 | S & F for sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 106 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed by Engineer-in-Charge. |
| 107 | S & F for MCB Tripple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed by Engineer-in-Charge. |
| 108 | S & F for MCB Single pole and neutral rated capacity 40 to 63 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed by Engineer-in-Charge. |
| 109 | S & F for MCB Single pole and neutral 5 to 32 Amps, 240 Volts rated capacity breaking capacity 10 KA, 'C' curve complete all as specified and as directed by Engineer-in-Charge. |
| 110 | S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed by Engr-in-Charge. Make:-Make Bajaj Cat Part No BCLAB 20W WH LED P, Wipro Cat Part No LL20-281-xxx065-ALI or equvalent make in Phillips and Havells. |
| 111 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25/35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. Make:- Bajaj Cat Part No ENXT P 24L WH CR PC SD (Edge plus Series) or equivalent in Philips, Wipro |
| 112 | M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted complete all as specified and directed by Engr-in-Charge. |
| 113 | M&L for filling dry and clean sand in trenches for cable cushioning 8cm below and 15 cm above complete all as specified and directed. |
| 114 | M&L for un reinforced precast concrete cable cover, LV low voltage type-I flat size 250mmx150mmx40mm complete all as specified and directed. |
| 115 | M & Lfor XLPE insulated screened PVC bedded galvanised steel strip or wire armoured UG heavy duty electric cable with aluminium conductor 1100 Volts grade cross sectional area of 25 Sqmm 4 core laid in trenches under floor/road/hard standing, along poles etc complete all as specified and as directed by Engineer-in-charge. |
| 116 | S&F GI pipe light grade 40mm bore for cable protection fixed to poles/along wall/floor/under road/acrossthe drain or nallah including taking down old unservuceable GI pipe complete all as specified and as directed by Engineer-in-charge. |
| 117 | M & Lfor XLPE insulated screened PVC bedded galvanised steel strip or wire armoured UG heavy duty electric cable with aluminium conductor 1100 Volts grade cross sectional area of 10 Sqmm 4 core laid in trenches under floor/road/hard standing, along poles etc complete all as specified and as directed by Engineer-in-charge. |
| 118 | M&L for boring of holes under road, pavement, hard standing by manual technique and necessary macine including HDPE pipe of 100mm dia suitable for 0.4 Mpa working pressure complete all as specified and directed. |
| 119 | Excavation in trenches n.exc 1.5 m wide & n.exc 1.5 m depth for foundations, sewage lines etc and n.exc 10 Sqm on plan for manholes and getting out in soft/loose soil complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender