Defence Statutory Bodies & Commissions/Committees Closing in 26 days TDR #57831935

Tender For Provision Of Ht 11 Kv Breaker (Vcb) Panel At Mdss, Naval Base Karwar

Issued by Statutory Bodies & Commissions/Committees · Uttara Kannada, Karnataka
Tender Value
71.53 Lakhs
Estimated cost
Bid Submission
29 Oct 2026
26 days left
EMD
1.32 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Uttara Kannada → Karnataka
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provision Of Ht 11 Kv Breaker (Vcb) Panel At Mdss, Naval Base Karwar

BOQ

Name of Work:- PROVISION OF HT 11 KV BREAKER (VCB) PANEL AT MDSS, NAVAL BASE KARWAR
Sl. No. Item Description
1Design, Manufacture, Supply, Installation, Testing and Commissioning of HT, 11 KV VCB line up 08 panels, standalone switch boards including Bus coupler with VCB and bus bar chamber consiting of 800 A VCB 11 KV - 02 Nos Incomer, 800 A VCB 11 KV - 01 No for Buscoupler and 630 A VCB 11 KV - 05 Nos outgoing, Indoor type VCB, both side extendable, 630 Amps, 25 kA / 1 Sec. totally enclosed, free standing, floor mounting type, compartment based with truck mounted Vacuum Circuit Breaker, Spring Operated Electrically and Manually Charged Operating Mechanism suitable for horizontal isolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltage rated, complete VCB Panel conforming to IEC 62271-200 standards and IP 4X Class of protection comprising necessary bus-bar extensions and connections, Circuit Breaker suitable for E2, M2, C2 duty, Vacuum Interrupters of the circuit breakers completely encapsulated in epoxy housing, Switchgear and control gear panels of fully arc proof for 25 kA for 1 Sec AFLR with Microprocessor based Numerical Relay Communicable type in line with RS 485 Modbus Protocol, comprising of Three Over Current , One Earth Fault Protection Relay with high set for both Phase & Earth and with Fault Memory, Universal Auxiliary Supply, Master Trip Relay, Trip Circuit Supervision Relay, Digital Multifunction Meter with Class 1.0, PT 11KV/110V AC, Power Pack 11KV/230V AC Complete all as specified and as directed and with the following features:-
211 kV, 800 Amps, 25 KA VCB Incomer Panel - 02 Nos Shall be consisting of the following each:[a] 800 Amps Continuous high conductivity electrolytic copper bus bar, Raychem Insulated for full voltage, phase identification made at the end by coloured tape, bus bar shall be mounted on integral seal of bushing and inter connection with electrolytic grade copper with joints silver plated.[b] Circuit Breaker shall be mounted on with drawable truck which shall roll out horizontally from service position to isolated position with ease.[c] Motorised Spring Charged Mechanism 230V, AC. [d] Cast Resin Current Transformer , 11 KV , 200-100/1+1 Amp , 15 VA, CI 5P 10, CL:0.5 - 03 Nos. [e] Cast Resin 3 Phase PT 11KV/110 volts, 100 VA , CI 1.0 - 03 Nos with 3A capacity PT Fuses.
3[f] Accessories like Local Remote Selector Switch, Breaker Control Switch [TNC] , Space Heater with Thermostat, DC & AC control circuit through MCB, Indication Lamps for RYB Phases , Spring Charged, DC Supply Health Breaker ON/OFF, Breaker in Service, Test, Disconnected Position.[g] Multi Function Meter, Digital Type [Displaying A, V, PF, Hz, KVA, KW, KVAR, KWH, KVARH etc. Class 0.5 with RS 485 Port [MODBUS PROTOCOL] [h] High Speed Master Trip Relay - 01 No [i] Trip Circuit Supervision Relay - 01 Set[j] PT Fuse Failure Relay - 01 set [k] Anti Pumping Relay [VAA11] - 02 Set: [l] Air Insulated Rear Bottom Entry Cable Box And Side Cable Box suitable for termination of incoming and Outgoing HT XLPE 11KV cables.
4[m] Feeder Protection Relay with Phase overcurrent (50/51), Directional phase overcurrent (67), SOTF Switch On To Fault (50 HS), Current unbalance (46), Thermal overload (49), Earth fault (50N/51N), Directional earth fault (67N), Undervoltage (27), Overvoltage (59), Zero sequence voltage protection (59N), Frequency (81), auto reclose (79), Circuit breaker failure (50BF),Cold load pick-up and magnetising inrush, Programmable stages (99), CB wear. Relay shall have 4CT and 4 VT inputs. Relay shall be provided with at least 16 digital inputs and 8 digital out puts and 1 self-supervision output. Relay shall have also these features inbuilt. MIMIC display with single line representation and switch gear controls shall be possible through the MIMIC. Shall support native IEC 61850 communication Protocol, front USB for connecting to PC, conformal coating to withstand harsh environment, support PRP redundancy communication protocol on FO ports. Web server (web HMI) feature to monitor and control using LAN. Shall have minimum 1000 events. Relay shall support SNTP time synchronization & support customer defined programmable logic with minimum 8 programmable LED. Relay shall have disturbance recorder with settable sample rate from 8 cycle to 32 cycle.
5[n] Panel shall also have additional features like Continuous Rated Closing / Tripping Coils, Spring Charging Handle, Manual Closing / Tripping off the VCB with Compartment Door Closed, Short Time Rating 01 Sec as per IEC 62271-200 and VCB shall be suitable for E2, M2, C2 Class.[o] Breaker shall also be provided with Auxiliary Switch 6NO + 6 NC Contacts mounted on the draw out portion of the Switchgear and Position Cell Switch with 03 NO + 1 NC Contact each for Test Position and Service Position.
611 kV, 630 Amps, 25 KA VCB Outgoing Panel [05 Nos] each consisting of:[a] 630 Amps Continuous high conductivity electrolytic copper bus bar, Raychem Insulated for full voltage, phase identification made at the end by coloured tape, bus bar shall be mounted on integral seal of bushing and inter connection with electrolytic grade copper with joints silver plated.[b] Circuit Breaker shall be mounted on with drawable truck which shall roll out horizontally from service position to isolated position with ease.[c] Motorised Spring Charged Mechanism 230V, AC. [d] Cast Resin Current Transformer , 11 KV , 200-100/1+1 Amp , 15 VA, CI 5P 10, CL:0.5 - 03 Nos. [e] Cast Resin 3 Phase PT 11KV/110 volts, 100 VA , CI 1.0 - 03 Nos with 3A capacity PT Fuses. [f] Accessories like Local Remote Selector Switch, Breaker Control Switch [TNC] , Space Heater with Thermostat, DC & AC control circuit through MCB, Indication Lamps for RYB Phases , Spring Charged, DC Supply Health Breaker ON/OFF, Breaker in Service, Test, Disconnected Position.[g] Multi Function Meter, Digital Type [Displaying A, V, PF, Hz, KVA, KW, KVAR, KWH, KVARH etc. Class 0.5 with RS 485 Port [MODBUS PROTOCOL] [h] High Speed Master Trip Relay - 01 Nos [i] Trip Circuit Supervision Relay - 01 Set [j] PT Fuse Failure Relay - 01 set [k] Anti Pumping Relay [VAA11] - 01 Set:[l] Air Insulated Rear Bottom Entry Cable Box And Side Cable Box suitable for termination of incoming and Outgoing HT XLPE 11KV cables.
7[m] Feeder Protection Relay with Phase overcurrent (50/51), Directional phase overcurrent (67), SOTF Switch On To Fault (50 HS), Current unbalance (46), Thermal overload (49), Earth fault (50N/51N), Directional earth fault (67N), Undervoltage (27), Overvoltage (59), Zero sequence voltage protection (59N), Frequency (81), auto reclose (79), Circuit breaker failure (50BF),Cold load pick-up and magnetising inrush, Programmable stages (99), CB wear. Relay shall have 4CT and 4 VT inputs. Relay shall be provided with at least 16 digital inputs and 8 digital out puts and 1 self-supervision output. Relay shall have also these features inbuilt. MIMIC display with single line representation and switch gear controls shall be possible through the MIMIC. Shall support native IEC 61850 communication Protocol, front USB for connecting to PC, conformal coating to withstand harsh environment, support PRP redundancy communication protocol on FO ports. Web server (web HMI) feature to monitor and control using LAN. Shall have minimum 1000 events. Relay shall support SNTP time synchronization & support customer defined programmable logic with minimum 8 programmable LED. Relay shall have disturbance recorder with settable sample rate from 8 cycle to 32 cycle. [n] Panel shall also have additional features like Continuous Rated Closing / Tripping Coils, Spring Charging Handle, Manual Closing / Tripping off the VCB with Compartment Door Closed, Short Time Rating 01 Sec as per IEC 62271-200 and VCB shall be suitable for E2, M2, C2 Class.
8[o] Breaker shall also be provided with Auxiliary Switch 6NO + 6 NC Contacts mounted on the draw out portion of the Switchgear and Position Cell Switch with 03 NO + 1 NC Contact each for Test Position and Service Position.[p] Numerical relay differential protection [87] - 1 No.[q] 12 Window annunciator. (r) Neccessary fabrication work including extension of busbar between both incommig panels for buscoupler as drawing approved by GE is included in the above qouted rate.
9Supply and laying or fixing or passing through pipe or in cable ducts, 11000 volts (E) grade XLPE insulated,screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor of 3 core 240 Sqmm size complete all as specified and as directed by Engineer -in-Charge
10Supply and laying or fixing or passing through pipe or in cable ducts, 11000 volts (E) grade XLPE insulated,screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor of 3 core 185 Sqmm size complete all as specified and as directed by Engineer -in-Charge
11Supply, jointing & testing Indoor end termination cable joininting kit, heat shrinkable type 11 KV HT joint kit suitable for PVC / XLPE insulated stranded aluminium conductor of size 3 core 240 sqmm to 300 Sqmm complete all as specified and as directed by Engineer -in-Charge
12Supply, jointing & testing Indoor end termination cable joininting kit,heat shrinkable type 11 KV HT joint kit suitable for PVC / XLPE insulated stranded aluminium conductor of size 3 core 120 Sqmm to 185 Sqmm complete all as specified and as directed by Engineer -in-Charge
13Supply, jointing & testing straight through type cable joininting kit heat shrinkable 11 KV HT joint kit suitable for 3 core 240 Sqmm to 400 Sqmm PVC / XLPE insulated stranded aluminium conductor complete all as specified and as directed by Engineer -in-Charge
14Supply, jointing & testing straight through type cable joininting kit heat shrinkable 11 KV HT joint kit suitable for 3 core 120 Sqmm to 185 Sqmm PVC / XLPE insulated stranded aluminium conductorcomplete all as specified and as directed by Engineer -in-Charge
15M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised iron earth strip 32mmx6mm size, by means of bolts, nuts, check buts and washers of galvanised iron and 32mmx6mm earth lead protected by provision of GI medium grade pipe 40mm bore including provision 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40mmx40mmx6mm with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, 15 CM alternate layer of charcoal and salt around all sides of earth plate with fixing arrangements, funnel, wire mesh and earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57831935
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 71.53 Lakhs
LAST DATE 29-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provision Of Ht 11 Kv Breaker (Vcb) Panel At Mdss, Naval Base Karwar
Basic Detail
Tender No 86147/E8
Bidding Type Tender
Location
City Uttara Kannada
State Karnataka
Key Dates
Publish Date 01 Oct 2026
Submission Date 29 Oct 2026
Open Date 31 Oct 2026
Finance
Tender Value 71.53 Lakhs
Tender Fee 1000
EMD 1.32 Lakhs
Exemption Available
Document List
84fcd6ae-babc-457d-bf55-eab491ead90f.html
86147TENDER.pdf
BOQ_888111.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 26 days
Oct 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 28 days

Tender Documents

Download All (ZIP) ↓
html

84fcd6ae-babc-457d-bf55-eab491ead90f.html

pdf

86147TENDER.pdf

xls

BOQ_888111.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders