Tender For Providing Of Additional Power Plugs, Power Mains And Installation Of Port Arrangements To The Pre Fabricated Workshop Building For Centers Of Excellence In Government Polytechnic College, Coimbatore.
Tender Value
8.55 Lakhs
Estimated cost
Bid Submission
15 Oct 2026
12 days left
EMD
8600
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Coimbatore → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing Of Additional Power Plugs, Power Mains And Installation Of Port Arrangements To The Pre Fabricated Workshop Building For Centers Of Excellence In Government Polytechnic College, Coimbatore.
BOQ
| Sl. No. | Item Description |
| 1 | Supply and fixing of 2 Nos. 6/16A two module socket, 2Nos 16A module switch on suitable module surface mounting Box (GI) with module cover plate (plastic) in flush with wall with connections. (Higher end) |
| 2 | Supply and fixing of 10A DP MCB in sheet steel enclosure in flush with wall and making good of the concealed portion with earth connection. (Higher end) |
| 3 | Supply and fixing of 32A FP MCB in flush in the existing 3 phase 7 Segment DB |
| 4 | Supply and fixing of 32A FP MCB in sheet steel enclosure in flush with wall and making good of the concealed portion with earth connection. (Higher end) |
| 5 | Supply, Installation and termination of RJ 45 Cat-6 I/O Socket with, Back box, Face plate with surface mount. (Make:D link/Legrand/ Equivalent). |
| 6 | Supply and run of 2 of 2.5 sq mm PVC insulated SC unsheathed FRLS copper Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with contineous earth wire connection of 2.5 sqmm copper wire with and making good of the concealed portion. |
| 7 | Supply and run of 2 of 4.0 sq mm PVC insulated SC unsheathed FRLS copper Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with contineous earth wire connection of 4.0 sqmm copper wire and making good of the concealed portion with suitable colour. |
| 8 | Supply and run of 4 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with suitable colour |
| 9 | Supply and run of 4 of 6 sq mm PVC insulated SC unsheathed FRLS copper Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 6 sqmm copper wire and making good of the concealed portion |
| 10 | Supply and clamping of UTP Cat 6 cable through 25mm PVC rigid pipe concealed in the wall/ceiling with necessary connection and making good of the concealed portion with painting of suitable colour Make : Finolex or Dlink or equivalent |
| 11 | Supply and run of cable tray GI/Metal type 300mmx150mm with necessary Angle iron frame work with suitable cutting and welding etc complete as directed by the departmental officers |
| 12 | Supply and installation 19\\" 6U three tier MS Rack for housing LAN Switches with top and Bottom Cable Entry provision along with necessary power distribution unit,cable manager, fan and Lockable Toughened Glass Door. (DATA-7) |
| 13 | Supply and fixing of 4 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 No 40A 4P MCB Isolator as incoming and 2 Nos 32A 10KA FP MCB and 2 Nos 32A 10KA DP MCB as outgoing on suitable angle iron frame on wall with Earth connection only. Higher End(DATA-8) |
| 14 | Supply and Laying of 3 1/2 x 25 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. |
| 15 | Supply and clamping of 3 1/2 x 25 sq.mm PVC LTUG armoured cable on post or on wall with MS clamps |
| 16 | Supply and fixing of brass cable gland for 3-1/2 x 25 sq.mm. PVC armoured LTUG cable with earth connection |
| 17 | Supply and providing cable end termination of 3-1/2x25sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete. |
| 18 | Supply and installation of 4 Megapixel resolution Infrared Network Bullet Camera with IR Range upto 30 meters,120dB WDR,Video Compression in H.264/MJPEG format, Day & Night auto switch IR cut filter, IP67 Protection level with mounting Bracket included (Make and Model: Hikvision/ Dahua/ Equivalent). |
| 19 | supply and fixing of 150w flood light on wall with Integrated Driver over the angle frame. |
| 20 | Earthing as per PWD standard with an earth electrode of 2 metre Class 'B' GI pipe of dia not less than 32mm complete with necessary masonry work |
| 21 | Supply and Run of 1 of No.8 SWG GI wire in suitable PVC rigid pipe on wall / floor / ground for earth connection |
| 22 | Supply and fixing of LT cable route indicator with suitable angle not less than 38mm x 38mm 6mm and 0.6mtr long excavation of earth to a depth of 0.6 mtr and concreting the ground level and making good of the ground as directed by the departmental officers. |
| 23 | Supply and clamping of CAT 6 Outdoor Cable along stay wire with MS clamp support. |
| 24 | Supply and Laying of 3 core 2.5 sq.mm copper cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. |
| 25 | Supply and clamping of 3 core 2.5 sq.mm copper cable on post or on wall with MS clamps |
| 26 | AC arrangements: |
| 27 | Supply erection, testing and commissioning of 2.0 TR (6000 K.c al/Hr) ABS Plastic Split type Air conditioner conforming to IS 1391 (Part-2) 1992 with Amdt No. 1 to 2 fitted with rotary compressor operating on refrigerant R-32/non CFC suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with star rating of 3 star as per BEE specification and capable of performing the functions of |
| 28 | Cooling |
| 29 | Dehumidifying |
| 30 | Air Circulating |
| 31 | Filtering |
| 32 | Convertible AC |
| 33 | Smart 2 way/ 4 way Swing |
| 34 | Low Gas Detection |
| 35 | The installation works for the above split type AC units includes the following. |
| 36 | 1.Mounting / Fitting Indoor and outdoor units at their respective locations. |
| 37 | 2. Laying refrigerant pipeline of required length connecting not exceeding 3 metre distance and both units after drilling hole/holes in the wall if required. |
| 38 | 3. Insulating the suction pipe with expanded polyethylene foam 5mm tubing. |
| 39 | 4. Laying 15mm dia flexible PVC drain pipe to throw out the condensate water being formed within the indoor unit. |
| 40 | 5. Leakage testing the entire system unit. |
| 41 | 6. Charging refrigerant gas in the unit. |
| 42 | 7. Suitable electric wiring to be provided with 2.5 Sq mm PVC insulated copper wire between indoor and outdoor units up to 6 Mtrs length and up to switch within 3 Meters of location of indoor unit (Make: Carrier/Voltas/equivalent) |
| 43 | Supply erection, testing and commissioning of 1.5 TR (6000 K.cal/Hr) ABS Plastic Split type Air conditioner conforming to IS 1391 (Part-2) 1992 with Amdt No. 1 to 2 fitted with rotary compressor operating on refrigerant R-32/non CFC suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with star rating of 3 star as per BEE specification and capable of performing the functions of |
| 44 | Cooling |
| 45 | Dehumidifying |
| 46 | Air Circulating |
| 47 | Filtering |
| 48 | Convertible AC |
| 49 | Smart 2 way Swing |
| 50 | Low Gas Detection |
| 51 | The installation works for the above split type AC units includes the following. |
| 52 | 1.Mounting / Fitting Indoor and outdoor units at their respective locations. |
| 53 | 2. Laying refrigerant pipeline of required length connecting not exceeding 3 metre distance and both units after drilling hole/holes in the wall if required. |
| 54 | 3. Insulating the suction pipe with expanded polyethylene foam 5mm tubing. |
| 55 | 4. Laying 15mm dia flexible PVC drain pipe to throw out the condensate water being formed within the indoor unit. |
| 56 | 5. Leakage testing the entire system unit. |
| 57 | 6. Charging refrigerant gas in the unit. |
| 58 | 7. Suitable electric wiring to be provided with 2.5 Sq mm PVC insulated copper wire between indoor and outdoor units up to 6 Mtrs length and up to switch within 3 Meters of location of indoor unit (Make: Carrier/Voltas/equivalent) |
| 59 | Supply of 5 KVA Electronic Automatic Voltage Stabilizer (Higher end) with Input Voltage range of 170 Volt – 270 Volt and Output Voltage range 200 Volts to 240 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration. |
| 60 | Supply of 4 KVA Electronic Automatic Voltage Stabilizer (Higher end) with Input Voltage range of 170 Volt – 270 Volt and Output Voltage range 200 Volts to 240 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration. |
| 61 | Supply and fixing of water drain pipe line (1\\" PVC pipe). |
| 62 | Supply and fixing of MS stand for fixing Outdoor unit. . |
| 63 | Supply and laying of 5/8\\" and 3/8\\" copper refrigerant pipe of 0.8mm thick with 2.5 sqmm 3 core chord between indoor and outdoor unit. (Extra beyond 3 mts supplied with AC unit) |
| 64 | GST 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysOct 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender