Tender For Replacement Of Online Ph, Cod, Bod & Tss Analyzer With Connectivity Software Iot Datalogger For Cpcb And Spcb At Sewerage Treatment Plant In Pollachi Municipality.
Tender Value
24 Lakhs
Estimated cost
Bid Submission
09 Oct 2026
5 days left
EMD
24000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Coimbatore → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Replacement Of Online Ph, Cod, Bod & Tss Analyzer With Connectivity Software Iot Datalogger For Cpcb And Spcb At Sewerage Treatment Plant In Pollachi Municipality.
BOQ
| Sl. No. | Item Description |
| 1 | Online pH, COD, BOD & TSS Analyzer with AADHAV INTECH TNPCB Connectivity Software for WaterMake: Aadhav IntechModel: AAD-OCEMS-L600Range: pH – 0 to 14COD – 0 to 500 ppmBOD – 0 to 375 ppm TSS – 0 to 200 ppm |
| 2 | IoT Datalogger for CPCB ODAMS and TNPCB ConnectivityMake: Aadhav IntechModel: AAD-DL-0031.5GHz 64-bit Compact Quad Core Microprocessor with GPU4GB High Speed RAM to handle large volume of data1 Gbps Ethernet, 802.11ac Wi-Fi and Bluetooth 5.0 for Network SupportTwo USB 3.0 ports and two USB 2.0 ports64 GB removable storage media (expandable up to 256 GB)Ultra secure Linux Operating SystemPower adapterDIN Aluminium Enclosure with cooling fanEnd User self-configurable application to connect instrument(s) and transmit secured data over internet to CPCB and SPCB |
| 3 | Enclosure IP65 * Wall mount * Weatherproof * Fibre Reinforced Plastic Enclosure including circuit breakers, DIN Rail, Switchbox, etc |
| 4 | RS485 Modbus to USB Converter |
| 5 | Installation, Commissioning & Training Charges |
| 6 | Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in units of (kilolitres/ cubicmeter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3m/sec to 4 m/sec and be constructed as follows:Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects Coil Housing shall be fabricated from stainless steel (SS 304) with Anticorrosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP 68 protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output, Communication interface is RS485, HART output, . The microprocessor based signal converter shall have a self diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out Higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminium with glass window. The converter cum transmitter should be fully programmable form the front facia. The programming should be user friendly, self-prompting menu driven. Flowmeter test calibration certificate from FCRI, flow test lab/ NABL accridiated lab to be furnished. |
| 7 | 500mm |
| 8 | Installation and commissioning Charges for Flowmeter as directed by the Department officers. |
| 9 | Supply and Delivery of MS pipes -Spiral/Longitudinal welding as per as per IS 3589/2001 with excise duty with internal food grade epoxy coating and external epoxy coating |
| 10 | 508X6.3 |
| 11 | Supply and Delivery of MS BOLTS AND NUTS 16 mm dia x 65 to 90 mm length fully threaded bolts and nuts with 2 Nos. Washers. |
| 12 | Supply and delivery of 3 KVA UPS 1 PHASE UPS (Single Phase In & Single Phase Out) capacity -System with Battery -1 hour Back-up. |
| 13 | Comprehensive servicing, inspection, testing and calibration of electromagnetic flowmeter, including dismantling, cleaning of sensor/electrodes, checking of sensing elements, inspection of cable and terminal connections, verification of transmitter/display unit, checking of signal output, troubleshooting, calibration, testing and commissioning. The work shall include all necessary labour, tools and testing instruments required to restore the flowmeter to proper working condition, including consumables spares etc. |
| 14 | Inlet -450mm |
| 15 | GST18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysOct 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓