Tender For State Plan-2026-2027- Renovation Of Existing Mannarkkad Section Office Building -Office Maintenance Work Including Painting, Electrification, Replacing Damaged Plumbing And Sanitary Items, Replacing Brocken Window Glass -General Civil Work
Tender Overview
Project Description
Tender for State Plan-2026-2027- Renovation Of Existing Mannarkkad Section Office Building -Office Maintenance Work Including Painting, Electrification, Replacing Damaged Plumbing And Sanitary Items, Replacing Brocken Window Glass -General Civil Work
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-Oct-2026 | Time Extension | Date | 12-Oct-2026 |
| 2 | 13-Oct-2026 | Date | Date | 22-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Renovation of Mannarkkad Section Office -Painting , Lettering etc complete. |
| 2 | 15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar |
| 3 | 15.11.2:Removing mortar from and cleaning stones and concrete articles ( net quantity of stacks of cleaned materials will be measured):In cement mortar |
| 4 | 50.6.1.6:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete |
| 5 | 13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand). |
| 6 | 13.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm |
| 7 | 14.5.2:Renewing glass panes, with putty and nails wherever necessary including racking out the old putty :Float glass panes of thickness 5.5 mm (weight not less than 12.5kg/sqm) |
| 8 | 4.3.2:Centering and shuttering including strutting, propping etc. and removal of form work for:Retaining walls, return walls, (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. |
| 9 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 10 | 5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 11 | 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 12 | 2.1.1:Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil |
| 13 | 13.50.3:Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works |
| 14 | 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 15 | 13.71:Lettering with black Japan pint of approved brand and manufacture |
| 16 | 14.72:Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done . |
| 17 | 13.109.1:Finishing walls with water proofing cement paint of required shade :Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litrs/10 sqm complete including cost of Priming coat. |
| 18 | ELECTRICAL ESTIMATE |
| 19 | OD269575/2025-2026:Supplying and fixing Good quality 2.5sqmm (1/2 coil),1.5sqmm (1/2coils) with 20mm conduit (70m length),bend(10nos),Clamp(10nos),Round Blocks (2nos),Angle Holder(5nos),5A Switches (45nos),5A Sockets(20nos),16A Socket (2nos),16A Switches (2nos),Switch Board etc. including all cost of materials ,labour charges etc. complete ( Rate taken from Delhi SoR Electrical) |
| 20 | OD269577/2025-2026:Supplying and Fixing 12W LED bulbs -5 nos,20W LED Tubes - 3nos,. including all labour charges etc .complete |
| 21 | OD78160/2026-2027:Supplying and fixing Of Good Quality Ceiling fan Including all cost of Material , Fixing charges , conceying Etc complete. |
| 22 | PVC Door for bathrooms, Office Tables etc. |
| 23 | OD269784/2025-2026:Supplying and fixing PVC Door for Bathrooms Including All costs of materials Labour charges fittigs etc complete. |
| 24 | OD269915/2025-2026:Supplying of good quality Office Table 2nos ,Good Quality Office Chairs 3nos, Pvc chair 5nos and Steel rack 1no Including all costs of conveyance, Material ,fixing etc Complete. |
| 25 | Plumbing Work |
| 26 | 100.98.48:Supply of PVC Tap Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender