Tender For Special Repair To Bldg No. Ow-05 & Provn Of Stone Masonry Retaining Wall In 39 Mdsr Under Pal Ur Mil Stn.

BOQ

Name of Work:- Spl Repair to Bldg No. OW-05 & Provn of stone masonry retaining wall in 39 MDSR Under Pal ur Mil Stn.
Sl. No. Item Description
1Taking down chowkhat or frame with shutter (without taking off shutter from the frame) n exc. 1.50 Sqm each incl taking out hold fast. Complete all as specified and as directed.
2Taking down chowkhat or frame with shutter (without taking off shutter from the frame) exc. 1.50 Sqm but n exc. 4 Sqm each taking each Complete all as specified and as directed.
3S&F pressed steel frames for door made out of MS Sheet 1.25mm thick of size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc Complete all as specified and as directed.
4M&L for Plain cement concrete, M-15 (Nominal mix), type B-1 (Using 20mm graded crushed stone aggregate) as in filling of steel chowkats or frames, cills and hold fast etc. complete all as specified and as directed.
5S&F factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30 mm thick comprising of virgin polymer of K value 58-60 (suspension Grade), calcium carbonate and natural fibres ( wood power/ rice husk/wheat husk) and non toxic additives ( maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N ( face) & 900 N ( Edge) , minimum compressive strenth 50 n/mm2 modulus of elasticity 850 n/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardant . WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screw, complete all as specified and directed.
6S&F factory made single extruded WPC (Wood Polymer Composite) glazed and skeleton shutter of size 35mm thick open rebated prepared to receive glass gauge etc without sash bars for securing glass, gauge etc comprising of virgin polymer of k value 58-60 (Suspension grade) calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 n (face) & 900n (edge), minimum compressive strength 50n/mm2 modulus of elasticity 850 N/mm2 and resistance to spred of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardant . WPC tobe laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessart full body threaded star headed counter sunk ss Screw, Complete all as specified and as directed.
7S & F for floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring, fixed in floor over all length of cover plate 140mm thick complete all as specified and directed.
8S&F butt hinges 100mm, cold rolled medium weight mild steel. Complete all as specified and as directed.
9S&F 125mm size, extruded aluminium alloy handles, fabricated type, anodised.Complete all as specified and as directed.
10S&F 150mm long aluminium tower bolts (ISI Marked) extruded type Complete all as specified and as directed.
11S&F 300mm, Mild steel spring for door, ordinary rat tail rod pattern springs, including roller and roller plate Complete all as specified and as directed.
12S&F 300 mm size brass sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and as directed.
13S&F Galvanised mild steel wire cloth 0.56mm of nominal dia of each wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples.complete all as specified and as directed.
14Providing and fixing factory made PVC White colour sliding window three track made of extruded profiles with wall thickness of 2.03 mm (+,- 0.2 mm) Window profile with hollow section with multi chamber frame (88mmx52mm), sliding sash(42mm x 67 mm). Sliding mesh smash (42mmx 57 mm) Sliding interlock (One vertical length in each shutters) (45.5 mmx 28 mm), Glazing bead (24.5mm x 16 mm) will be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc, making arrangement for fixing of hardware. EPDM gasket, 1.2+ 0.2 mm thick galvanized steel Frame (30mm x 18 mm) 2 Nos, sliding sash (26mm x 10 mm) profile to be inserted in required profile, frame will be fixed to wall with 8 mm x 100 mm long fasteners. Hardware to be included (Touch Lock of Zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and 5 mm thick glazing with selected quality glass. Complete all as specified and directed.
15S & F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290, (Gde-E-16), complete all as specified and directed.
16M&L for 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed
17Dismantling boarding any description fixer in any position with screws, complete all as specified and as directed.
18M&L for Brickwork with old size sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in cm (1:6) complete all as specified and as directed.
19M&L Rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finishing the surface even and smooth without using extra cement
20M & L for Rendering 15 mm thick in two coats i.e. 10 mm thick in CM 1:6 and 5 mm thick in CM 1:4 using water proofing liquid compound as per manufacturer's instructions on other than fair faces brick or concrete surfaces and finishing surfaces even & smooth without using extra cement complete all as specified and directed. Note :- Water proofing liquid compound shall be measured and paid separately
21M&L for Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gm/litre of approved manufacturer of required shade and colour complete as per manufacturers specification two or more coats over 2mm wall care putty on new surface of wall including preparation of surfaces with complete all as specified and as directed.
22Material & Labour for applying two or more coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (Company Depot Tinted ) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces of wall complete including preparation of surfaces of walls complete all as specified and as directed.
23Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
24M&L for 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded crushed stone aggregate) as in plinth protection.complete all as specified and as directed.
25M&L for Cement concrete in foundations, filling and mass concrete PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate), complete all as specified and as directed.
26M&L for RCC Nominal mix 1:2:4 type B1(using 20 mm graded crushed stone aggregate) in foundations, including rafts, footing, foundation beam plinth beams bases for column etc complete all as specified and as directed.
27M&L for RCC Nominal mix 1:2:4 type B1(using 20 mm graded crushed stone aggregate) in chajjas complete all as specified and as directed.
28RCC M-25 design mix (using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
29Formwork to flat sides of concrete foundations, footings, bases for columns, rafts, and raft beams, sides and soffits(if any) of foundation and plinth beams, and similar work, vertical or to batter for fair finished surface.complete all as specified and as directed.
30Formwork to fair flat sides and soffits of floor or roof beams, beams haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams for fair finished surface,complete all as specified and as directed.
31Formwork to flat chullah hoods,chajjas,troughs and similar items including edges fair finished surfaces,complete all as specified and directed.
32M&L for TMT bars 10mm dia and over cut to length, bend to shape required including cranking, bending, spirally for hooping columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
33As per item no.32 above but 5mm dia and over upto and including 10mm dia in stirrups spacers and binders,complete all as specified and as directed.
34Dismanting posts or struts(wood steel,or RCC) any section , including taking out embedded portion embedded in concrete, brick work, masonry etc and making good disturbed ground complete all as specified and directed.
35Dimantling framed trusses,span n exc 10 m complete all as specified and as directed.
36S&F, Rolled mild steel in roof trusses ( framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing ( beam, tee, angle, channel, tubular or flat sections) including distance pieces, cleats etc confirming to Fe 290 ( gde E-165) complete all as specified and as directed.
37S & F Compound girders and stanchions, lattice girders, aerial masts, and the like including caps, bases, splices etc, built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. Fe 290 (Gde- E- 165), complete all as specified and directed
38Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes with riveted,bolted or welded attachment etc confirming to Fe 290 ( gde E-165) complete all as specified and as directed.
39S&F Mild steel bolts purpose made dia n exc 12 mm with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut, exc 30 cm long, complete all as specifies and directed
40M&L Preparation of new steel surfaces and applying two coats of Synthetic enamel Paint over and including one coat of red oxide.complete all as specified and as directed.
41Dismantling of plain or corrugated steel sheeting,including nanital or similar pattern roof covering, M&L pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550MPa as in roof covering/cladding to wall, fixed with self tapping screws. Sheet colour approved by GE, complete all as specified and directed
42Dismanting of plain or corrugated steel sheeting,including nanital or similar pattern roof covering, S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550MPa as in roof covering/cladding/ridges to wall, fixed with self tapping screws complete all as specified and directed.
43Dismantling of wall and ceiling board (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including fillets,complete all as specified and as directed.
44S&F Providing and fixing tiled false ceiling of size 595 x 595mm in true horizontal level suspended on interlocking gypric metal grid of hot dipped galvanised steel section (galvanized @ 120 gsm/sqm, both side inclusive) consisting of 3600mm long main 'T' runner size 24x38mm and 0.30mm thick, 1200mm long cross 'T' of size 24 x 25mm and 0.30mm thick, 600mm secondary cross 'T' of size 24 x 25mm and 0.30mm thick, bottom exposed capping of width 24mm of all T-sections shall be of 0.25mm thick PPGI, wall angle is fixed along the perimeters of the ceiling to walls, partitions or columns etc with rawl plugs and wooden screws at 300mm centers Main 'T' runners are then suspended from ceiling using GI sloted cleats of size 27x37x25x1.6mm fixed to ceiling with 8mm dia and 45mm long dashfasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85x30x0.8mm spaced at max 1200mm centre to centre along main 'T' and not more than 150mm from spliced joints The last hanger at the end of each main runner should not be greater than 600mm from the adjacent wall, then 1200mm cross 'T' is interlocked between the main 'T' at 600mm center to center to form a grid of 1200x600mm and then Secondary cross 'T' is interlocked between the main 'T' at 600mm middle of the 1200x600mm grid to form grids of 600x600mm. Cross tees at the ends having length more than 600mm are to be supported independently. Finally white coloured Gyproc 8mm thick Dew Drop/Granular tiles of size 595x595mm having foil on backside & PVC paper on front side wrapped around edges to be placedin grid complete all as specified and directed, complete all as specified and directed by GE
45Dismantling of floor tiling incl cement mortar bedding (but not backing) removing serviceable tiles to a store and rubbish off premises, M&L non skid ceramic coloured tiles 7 to 8mm thick (square /rectangular) area of each tile exceeding 0 18 sqm but not exceeding 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick in CM 1:6 complete all as specified and directed.
46M&L Glazed ceramic coloured tiles(match as floor tiles) of size 450 x 300 x 7mm thick, on vertical surfaces of walls such as skirting dado etc. set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as specified and directed.
47S&F in repair stainless steel curtain rods 20 mm dia including brackets with cut hole suitable for 20 mm dia rod fixed with screws and gutties in wall, including end caps with wall ornament and fixed to curtain rod with screws of design/shape complete all as specified and as directed.
48M&L, Cement concrete type C-2 1:3:6 using 20 mm graded crushed stone aggregate in surface channels and drains etc including necessary formwork
49Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mi-tred/stopped ends
50M&L for 75 mm thick PCC 1:2:4 type B-2(using 40 mm graded crushed stone aggregate ). Complete all as specified and directed.
51M&L Chequered colour tiles of size 300x300mmx20mm thick or equivalent size as in machine pressed set jointed and pointed in neat cement slurry with grey cement and no pigment, over and including screed bed 20 mm thick in CM 1:4 complete all as specified and as directed.
52M&L for plain cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in roof padding, lintels cum upto 1.5 m span,coping,fillets,bed plates,plinth courses,seismic bands and the like finished fair and even including necessary formwork complete all as specified and as directed.
53M&L for Broken stone or boulders including hand packing (any thickness) at back side of weep holes and raising or lowering to the required level complete all as specified and as directed.
54M&L for PCC 1:5:10 (nominal) type E-2 (using 40 mm graded crushed stone aggregate ) as in foundation filling and mass concrete, complete all as specified and directed.
55S&F 110 mm bore PVC(SWR) pipes laid in weep holes complete all as specified and as directed.
56M & L for walling of random rubble,uncoursed,well bonded,bedded and solidly hearting built in cement mortar 1.4 , straight or curved on plan exceeding 6 mtr mean radius complete all as specified and directed.
57M&L for Raised pointing to random or polygonal rubble , uncoursed or brought upto course in CM 1:4,complete all as specified and as directed.
58Mild steel framed work such as grill,gratings etc. with ends of bars shouldered and/or rivetted or forged into spikes, framed guard bars,barred iron doors,ladders,framed balusters,walk ways,railings,framework of water tanks and similar works conforming to Fe-290 (Gde E-165) ,complete all as specified and as directed.
59Cutting channels, groove or rebates n exc 15 cm girth and trimming surface without reinforcement complete all as specified and as directed.
60Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement.
61Earth work in excavation in all kind of soil by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m,complete all as specified and as directed.
62M&L Walling random rubble stone masonry, uncourced, well bonded, bedded and solidly mearted, build in cement mortor 1:6 complete all as specified and directed.
63M&L Precast cement concrete C1 (1:3:6) as in bond stones, set in cement mortor 1:6 complete all as specified and directed.
64Returning Filling in (soil) including spreading, levelling, watering & well ramming in layers not exceeding 25 cm thick in any type of soil.complete all as specified and as directed.
65Removing Excavated Soil to a distance exceeding 250 m but not exceeding 500 m depositing where directed at a level not exceeding 1.50 m above the starting point, complete all as specified and directed.
66S&F PVC SWR pipe 110mm bore single socketed, in any length with rubber ring joints, fixed walls including clamps at joints, top and bottom complete all as specified and as directed.
67Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface not exceeding 20 mm and dressing of face beds and joints as specified, of random rubble walling uncourced or brought up to courses.
68M & L broken stone or boulders hand packing (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level.complete all as specified and as directed.
69S&F galvanized mild steel wire cloth 0.63mm nominal dia of wire and average width of Sqm aperature 1.40mm behind weep holes as directed by GE.
70Supply only 40 mm graded aggregate( for behind Wheep holes)complete all as specified and as directed.
71Taking down carefully existing aluminum / copper point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, pendants, tube light fitting, ceiling fan with regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces of walls, floors, ceiling etc to match with existing surfaces complete all as specified and directed.
72Taking down un-serviceable DB of any size and capacity including MCB etc, and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed.
73Taking down un-serviceable sub main wiring of any type and any size from wall, ceiling etc, complete all as specified and directed.
74M&L for replacement with 1.5 Sqmm single core multistranded copper conductor FRLSH, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistrand FRLSH, PVC insulated (unsheathed) drawn into and including concealed PVC rigid conduit medium grade ISI marked including pressed steel with existing colour terminated boxes of Modular GI sheet Metal flush Boxes of any way i.e. (1 to 8 way as per site requirement) for mounting switches, sockets, fan regulators etc for fixing one light/fan/bell point/fan/exhaust fan controlled by one 5/6 A switch and making good disturbed surfaces with CM (1:4) to match with the existing whitewash color surface complete all as specified and directed for the following - (a) Wiring shall be done by using proper colour coding(b) Earth wire shall be of green colour (c) On RCC roof/ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by GE.
75Description all as per serial item No 74 Above but 6 Amp socket outlet on same board complete all as specified and directed.
76Description all as per serial item No 74 above but socket outlet 6 Amps independent board complete all as specified and directed.
77Description all as per serial item No 74 above but for one 6 pin socket outlet 16 Amps on independent board with cables 2.5 sqmm size complete all as specified and directed.
78S&F Modular Switch one way 6 Amp, one module 240 volts ISI marked complete all as specified and directed.
79S&F Socket, 6A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
80S&F Socket 6A/16A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
81S&F Modular switch 1 way 16 A, 1 module, 240 volts ISI marked complete all as specified and directed.
82S&F Modular white cover plate 8M complete all as specified and directed.
83S&F Modular white cover plate 6M complete all as specified and directed.
84S&F Modular white cover plate 3M complete all as specified and directed.
85S&F Modular white cover plate 1M complete all as specified and directed.
86S&F Single pole and neutral enclosure with 1 two pin and earth plug and a socket complete with one single pole MCB, 20 Amp, 240 volts ISI marked complete all as specified and directed.
87S&F ceiling rose, 3 terminal surface type complete all as specified and directed.
88S&F Modular Fan step regulator, 120W, 1 module, 240 volts ISI marked complete all as specified and directed.
89S&F in replacement angle lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
90S&F LED bulb 9 watt complete all as specified and directed.
91S&F Decorative ultra slim LED Tubelight fitting of LED with extruded polycarbonate, enviornmental friendly energy efficient ready to use, 20 watt, 6500K fitting, including reqd length of not less than 1.0 Sqmm PVC multistrand BIS marked 03/02 core copper conductor for electrical connection from ceiling rose to connector of LED fitting including testing on completion all as specified and directed.
92S&F Decorative ultra slim LED Tubelight fitting of LED with extruded polycarbonate, enviornmental friendly energy efficient ready to use, 10 watt, 6500K fitting, including reqd length of not less than 1.0 Sqmm PVC multistrand BIS marked 03/02 core copper conductor for electrical connection from ceiling rose to connector of LED fitting including testing on completion all as specified and directed.
93Supply and Fix in replacement Recess mounted slim LED luminaire with drop down diffuser light 36W, 6500K having size 600x600mm, 230 volts AC corrosion resistant complete, as per sample approved by GE
94Supply and fix LED Flood light fitting 50 watt 230 V C outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver lamp bracket IP65 protection with impact and corrosion resistant complete with driver and lamp complete. Note: The item must be brought as per sample approved by GE
95Supply and fix LED bldg security light 35 watt with high pressure die cast aluminium hosing and heat resistant complete with driver lamp and bracket IP65 protection with impact and corrosion resistant complete with driver and lamp complete. Note: The item must be brought as per sample approved by GE
96Dismantling of electric storage heater (vertical type Geysers) 25 Ltrs capacity and deposited to MES yard and refixing grouting with high tensile rag bolt, nut & washer etc as directed as per site requirement and making necessary inlet / outlet water connection for Geysers. complete all as specified and directed.
97S&F 1200 mm sweep elegant white ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with energy efficient motor complete all as specified and directed. Note: Old unserviceable ceiling fan to be deposited in MES store yard.
98Supply and fix exhaust fan made of study Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and directed Note: Old unserviceable exhaust fan to be deposited in MES store yard.
99M&L in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 06 Sq mm for phase and neutral and one run of 06.0 Sq mm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the medium grade ISI mark PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note : Wiring shall be done in proper colour coding.
100M&L distribution board sheet steel powder coated for MCB with rated bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
101S &F in replacement of SPN 40 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
102S&F in replacement 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
103Supplying laying and testing cable XLPE insulate screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm, 4 core flat cable complete all as specified and as directed.
104Excavation in trenches n exc 1.5 m wide and n exc 1.5 mtr in depth for foundation laying of under ground cable erecting of pole stay not exc 10 sqm on plain and not exc 1.5 m depth and getting out in soft/loose soil complete all as specified and directed.
105Removal of excavated material (soil) to a distance n exc. 50m and depositing where directed complete all as specified and as specified.
106M&L for clean dry sand laid in trenches/ duct for bedding and cushioning to cable incuding spreading and levelling complete all as specified and as directed.
107M&L for sub class 'B' brick old size protection cover laid dry flat transversally along the length of cable on cushioning with width equal to the length of brick complete all as specified and directed.
108Material and labour for GI tubing (light grade) with all fitting laid in trenches or along pole/bldg or under road crossing and protection pipe or fixed alongwith wall/pole with necessary clamp nut bolt and washer bore of pipe 40mm complete all as specified and directed.
109Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm thick buried directly under ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level connected to galvanised earth lead wire 4.0mm by means of bolts, nuts, check nuts, washer including test point by means of bolts, nuts, check nuts, and washers of galvanized iron and connected to main switch / control board up to 7.5 metre away from earth electrode and including GI pipe light grade 40mm bore protection pipe & necessary excavation and earth work in any strata, PCC chambers in PCC 1:3:6 type B1, RCC 1:2:4 type B1 cover slab 50mm thick with 8mm dia TMT bars at 140mm C/C both ways, with lifting handle, watering pipe of GI medium grade 40mm dia, wire mesh, funnel, lugs and charcoal, salt etc all as applicable and as per plate No 3 of SSR Part-I and complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57823701
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 22-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Bldg No. Ow-05 & Provn Of Stone Masonry Retaining Wall In 39 Mdsr Under Pal Ur Mil Stn.
Basic Detail
Tender No GEP-84/2026-27
Bidding Type Tender
Location
City Kangra
State Himachal Pradesh
Key Dates
Publish Date 01 Oct 2026
Submission Date 22 Oct 2026
Open Date 29 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 95000
Exemption Not Available
Document List
BOQ_888131.xls
cc80cbc5-c1f8-4410-af80-18b158d2da04.html
td.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Oct 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 26 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_888131.xls

html

cc80cbc5-c1f8-4410-af80-18b158d2da04.html

pdf

td.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders