Project Description

Tender For Special Repairs To Bldg No T-422 & T-424 Xxxxx At Zakhama Mil Stn

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 22-Oct-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 29-Oct-2026

BOQ

Name of Work:- SPL REPAIRS TO BLDG NO T-422 & T-424 XXXXX AT ZAKHAMA MIL STN
Sl. No. Item Description
1Demolition of brickwork built in cement mortar including all quoins, arches, pillars etc. complete all as specified and as directed at site
2Material and labour for half brick work with bricks class designation 75, old size, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and as directed at site
3Taking out old unserviceable floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed at site
4M& L for Non - skid Coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in Cement mortar (1:6) complete all as specified and as directed at site
5M&L for cloured Glazed ceramic tiles in vertical surface 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick cement plaster in CM(1:4)
6Demolition of Reinforced Cement Concrete( Reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed at site
7M&L for RCC type B1 (1:1.5:3) using 20mm graded stone aggregate for slab supported on walls complete all as specified and as directed at site
8M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work for rough finish ; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed at site
9Material and labour for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending lapping etc as required and welding with existing bar and binding with wire complete all as specified and as directed at site
10M&L in repairs 20mm Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including provision of screed bed 15 mm thick in CM 1:4 complete all as specified and as directed at site
11Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including similar pattern roof covering complete all as specified and as directed at site
12M&L Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensil strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping complete all as specified and as directed at site
13M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge/valley gutterl, fixed with self tapping screws complete all as specified and as directed at site
14Dismantling timber scantling 40 Sqcm and over in section, framed work in any position complete all as specified and as directed at site
15M&L for Timber framed and fixed clean sawn 2nd class hard-wood in scantling fixed complete all as specified and as directed at site.
16Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness including cover fillets complete all as specified and as directed at site
17M&L for 4mm thick plywood, grade BWR, type BB, fixed with screws to timber frame work fixed with screws to timber frame work complete all as specified and as directed at site
18Supply and fix 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to GI snap grid frame work(size of 605x605mm) for false ceiling including suspenders/hangers 6mm dia GI wire(upto 1200mm length) adjusting level fixed to roof shads by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long and expansio hold fasteners 12.5mm dia 40mm long complete all as specified as per manufacturers instruction complete all as specified and as directed at site
19Supply and fix in repairs weather boarding, clean sawn, thickness 20mm to 25 mm and rebated on thick edge to give 20mm laps and fixed in 2nd class hardwood complete all as specified and as directed at site
20S&F in repairs Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates of Fe 410 W (Gde E-250 quality `B`) complete all as specified and as directed at site
21Taking down plastering in cement lime or cement mortar complete all as specified and as directed at site
22M&L rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1 : 4 mixed with WPC @ 3 % by the weight of cement used and finishing even and smooth without using extra cement complete all as specified and as directed at site
23M&L rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1 : 6 and finishing even and smooth without using extra cement complete all as specified and as directed at site
24M& L for Preparation of new plaster surface of walls and applying two coats of oil bound distemper over a coat of priming surface chalk whitening complete all as specified and as directed at site
25M&L for preparation of newly plastered surface of walls and applying two coat of cement base paint over one coat of primer complete all as specified and as directed.
26Supply only water proofing compound ISI Marked complete all as specified and as directed at site
27M&L including preparation and treating two coats of synthetic enamel paint over a coat of pink primer to new wood and wooden surface exceeding 10cm width or girth complete all as specified and as directed at site
28M&L including preparation and treating one coat of synthetic enamel paint on old painted wood and wooden surface exceeding 10cm width or girth complete all as specified and as directed at site
29M&L for preparation of old painted steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed at site.
30Demolition of cement concrete(unreinforced) of any description and in any position providedcomplete all as specified and as directed at site
31Materials and labour for 75mm thick PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) as in pavement/plinth protection finished the surface fair and even complete all as specified & directed.
32Taking down Shutters of any description n.exc 1 sqm each complete all as specified and as directed at site
33Taking down Shutters of any description exc 1 sq. m but n exc 2 sq m each complete all as specified and as directed at site
34S&F factory made flush door shutter 35 mm thick solid core construction, with block board core and plywood face panels, commercial type on both sides all as specified and directed at site
35S &F factory made 2nd class hardwood 30mm thick glazed and skeleton window/door shutter any numbers but divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, with plain, chamfered or rounded mitred and framing plain, chamfered or rounded, fitted with cut and metered beads for securing glass etc size of members of shutters as specified in SSR Part I Sec 8 clause 8.24 (b) complete all as specified and as directed at site
36Taking down Chowkhats or frameswith shutters (without taking off shutters from the frames) not exc. 1.5 sqm each complete all as specified and as directed at site
37S&F factory made Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and as directed.
38S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed.
39S&F Butt hinges, heavy weight, cold rolled mild steel, and fixed 100mm size complete all as specified and as directed at site
40S&F Aluminium anodised barrel tower bolt of extruded section and fixed 100 mm long complete all as specified and as directed at site
41Supply and fixing as in replacement 19/20mm dia mild steel chromium plated curtain rods with and including fixing socket complete all as specified and as directed.
42S&F extruded aluminium alloy handles, fabricated type, anodised 100mm size complete all as specified and as directed at site
43S&F in repairs , vitreous china water closet (Squatt pattern) orissa pattern size 580x540mm including connection to drain (or outgoing pipe) and flushing pipe, anti syphonage pipe, and including P trap or S trap complete all as specified and as directed at site
44S&F in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete all as specified and as directed at site
45S&F in repairs PVC valveless, syphonic action type, flushing cistern 10 ltr , low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed at site
46Supply & fix in repair vitreous china wash basin with padestal , white flat size 550x400mm incl bracket cutting for and pining in ends of brackets or erecting stand including PVC connection pipe 15 mm bore 450 mm long , waste coupling of PTMT complete all as specified and directed.
47S&F in repair bib taps cast copper alloy chromium plated fancy type with crutch or butterfly handle screwed down screwed down for iron pipe 15 mm bore complete all as specified and as directed at site
48Supply and fix in repair 15 mm stop cock fancy type, chromium plated each with long shank and cup, complete all as specified and as directed at site
49Supply and fix in repair Vitreous china Urinal bowl type flat back , size 465 X 355 X 265mm white with grating and union for discharge pipe including providing and fixing plugs , bedding urinal against wall in CM 1:2 , securing urinal to plugs with and including 60 mm long brass screws , pointing around urinal back in cement complete all as specified and as directed .
50Supply and fix in repair Pillar taps, 15 mm bore fancy type cast copper alloy, with caspstan heads, chromium plated, screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe or for connection pipe complete all as specified and directed.
51Supply and fix in repairs 15mm bore medium grade galvanized steel tubes with all fittings and fixed to wall and celing or laid in floors etc complete all as specified and as directed.
52All as per item above but 20mm bore complete all as specified and as directed at site
53Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc. removing materials for taking credit and making good disturbed surfaces of walls, floors, etc.etc complete all as specified and directed at site.
54Material and labour for point wiring (surface type) for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LS) unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FR-LS) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC casing caping of suitable size with all accessories and PVC rectangular boxes for mounting switch, socket and fan regulator etc complete all as specified and as directed. Note: (i) Wiring shall be done in proper colour coding using red , yellow, blue for phase, black for neutral and green for earth.
55All as per item No above but for 3 pin,5/6 Amp switch Socket combination on independent board with 2.5 sqmm copper wiecomplete all as specified and directed at site
56All as per item No above but for 15/16 Amp switch Socket combination on independent board with 2.5 sqmm copper wiecomplete all as specified and directed at site.
57Supply & fixing Switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal controlled by one switch complete all as specified & as directed.
58Supply & fixing Switch socket combination 2 in 1, 3 pin, 15 Amp flush type universal controlled by one switch complete all as specified & as directed.
59Supply and fixing in repairs Surface & wall mounted Energy efficient LED Tube Light Fitting, of 20 W, 6500 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
60Supply and fixing in repair Integrated LED Bulk head fitting with luminaire of 10W, 6000 K with Pressure Die Cast Aluminium Housing, IP54 protection, heat resistant glass cover, high power LEDs as light source, electronic driver and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
61Supply & Fixing exhaust fan made of sturdy engineering plastic 300mm sweep complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding and connecting to ceiling rose with 3 core flexible copper cable including making holes on the wall and making good to the disturbed surfaces including taking down and removing old UNSV fan and depositing to MES store yard complete all as specified and as directed.
62Supply & Fixing in repair Energy efficient, BEE 5 Star rated Storage type Water Heater [Geyser] 25 Litres Capacity with 2000 Watt Capacity heating element, 230 Volts, 50 Hz, Single phase AC, Conforming to IS - 2082, Vertical Storage type with Stainless Steel Inner Tank and ABS Outer Shell complete fixed to wall with suitable expansion fasteners including 02 Nos. of 450 mm long x 15mm dia Stainless Steel braided Flexible Hot & Cold Water connections and 15mm bore Non-Return Valve complete all as specified and as directed. NOTE: Old Geuser will be deposited to E/M store yard
63S&F in switch paino flush button single pole one way 5 amp, complete all as specified and directed at site.
64S & F in repair SP & N Enclosure with 2 Pin and Earth Metal Plug & Socket for incorporating SP MCB complete including One MCB, SP, 20 Amps, 240 Volts complete all as specified and as directed.
65Supply and fixing ceiling rose, PVC/polycarbonate, isolated body surface bakelite, 62.5mm x 50mm, ISI marked three terminals complete all as specified & directed.
66Supply and fixing in repairs of MCB DB SPN 8 ways, powder coated, double door, 240 Volts, including bus bar neutral link, earth bar and din rail, for fixing MCB of various rating complete all as specified and as directed
67Supply and fixing in repairs of MCB DB SPN 4 ways, powder coated, double door, 240 Volts, including bus bar neutral link, earth bar and din rail, for fixing MCB of various rating complete all as specified and as directed
68Supply & Fixing of MCB DB of capacity 40-63 Amps, 240 V, 10 KA 'C' curve complete all as specified and as directed.Note : MCB and MCB DB shall be of same make as approved by AGE (I).
69Supply & Fixing of MCB DB of capacity 32 Amps, 240 V, 10 KA 'C' curve complete all as specified and as directed.Note : MCB and MCB DB shall be of same make as approved by AGE (I).
70Supply & Fixing of MCB SP of capacity 6-32 Amps, 240 V, 10 KA 'C' curve complete all as specified and directed.
71Material and Labour in repair for House service bracket (hook type complete with 3.0m long G.I. pipe 40mm dia Medium grade, two nos. 90 degree bends, M.S. hook and stay or guy including dismantling of existing old unserviceable house service brackets, any type complete all as specified and as directed.
72Supply& fixing,1100 volts, grade (heavy duty)cable PVC insulated stranded aluminium conductor surved with inner sheathing of PVC tape and overall PVC sheathed in services connections suspended by insulating hangers not moe than 1 meter apart including 4 mm suspension wire, one twin core cable flat or round or 16 sqmm cable incl taking down old one, complete all as specified and as directed.
73S&F in repair submain wiring with PVC insulated & unsheathed two run of 6 sqmm single core multi stranded copper conductor cable (FRLSH), 100 Volt grade alongwith one run of 6 sqmm PVC insulated 7 unsheathed copper conductor cable (FRLSH), 1100 Vol grade, connected to common earth dolly as eartg continuity conductor,drawn through PVC casing caping of adequate size with all acessories including taking down existing burnt sub main wiring complete all as specified an as directed.NOTE: Three runs of 6 Sqmm cable and one run of casing caping shall be measured as one unit for payment purpose.
74Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set all as specified and as directed.Notes:-(i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57823695
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 24.25 Lakhs
LAST DATE 29-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repairs To Bldg No T-422 & T-424 Xxxxx At Zakhama Mil Stn
Basic Detail
Tender No 8177/E8
Bidding Type Tender
Location
City zakhama
State Nagaland
Key Dates
Publish Date 22 Oct 2026
Submission Date 29 Oct 2026
Open Date 05 Nov 2026
Finance
Tender Value 24.25 Lakhs
Tender Fee 500
EMD 48500
Exemption Not Available
Document List
8177tenderdocu.pdf
b9bf4206-5cfd-498c-8a23-9d5a7b95d2e2.html
BOQ_887943.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 29, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 3 days
Oct 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Nov 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.