Defence Statutory Bodies & Commissions/Committees Closing in 12 days TDR #57823491

Tender For Providing Of Otm Accn (200 Or) At Rrrc Under Ge (P) East Delhi Cantt-10

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
14.62 Crore
Estimated cost
Bid Submission
04 Dec 2026
12 days left
EMD
10.56 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Providing Of Otm Accn (200 Or) At Rrrc Under Ge (P) East Delhi Cantt-10

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 29-Oct-2026 Amendment No 1 Date 19-Nov-2026
2 12-Nov-2026 Amendment No 2 Date 04-Dec-2026

BOQ

Name of Work:- PROVN OF OTM ACCN (200 OR) AT RRRC UNDER GE (P) EAST DELHI CANTT-10
Sl. No. Item Description
1Lump sum price worked out by the contractor for Schedule 'A' Section-I (BUILDING WORKS) (Ref pre priced Schedule attached separately)
2Lump sum price worked out by the contractor for Schedule 'A' Section-II (SITE CLEARANCE AND SITE DEVELOPMENT) (Ref pre priced Schedule attached separately)
3Lump sum price worked out by the contractor for Schedule 'A' Section-III (EXACAVATION AND EARTH WORK) (Ref pre priced Schedule attached separately)
4Lump sum price worked out by the contractor for Schedule 'A' Section-IV (INTERNAL ELECTRIC SUPPLY) (Ref pre priced Schedule attached separately)
5Lump sum price worked out by the contractor for Schedule 'A' Section-V (INTERNAL WATER SUPPLY) (Ref pre priced Schedule attached separately)
6Lump sum price worked out by the contractor for Schedule 'A' Section-VI (SUMMER APPLIANCES) (Ref pre priced Schedule attached separately)
7Lump sum price worked out by the contractor for Schedule 'A' Section-VII (DG SET) (Ref pre priced Schedule attached separately)
8Lump sum price worked out by the contractor for Schedule 'A' Section-VIII (LIFT) (Ref pre priced Schedule attached separately)
9Lump sum price worked out by the contractor for Schedule 'A' Section-IX (FIRE FIGHTENING SYSTEM) (Ref pre priced Schedule attached separately)
10Lump sum price worked out by the contractor for Schedule 'A' Section-X (LIGHTING PROTECTION SYSTEM) (Ref pre priced Schedule attached separately)
11Lump sum price worked out by the contractor for Schedule 'A' Section-XI (HOT WATER SUPPLY) (Ref pre priced Schedule attached separately)
12Lump sum price worked out by the contractor for Schedule 'A' Section-XII (CENTRAL AIR COOLING) (Ref pre priced Schedule attached separately)
13Lump sum price worked out by the contractor for Schedule 'A' Section-XIII (BOREWELL) (Ref pre priced Schedule attached separately)
14Lump sum price worked out by the contractor for Schedule 'A' Section-XIV (EXTERNAL ELECTRIC SUPPLY) (Ref pre priced Schedule attached separately)
15Lump sum price worked out by the contractor for Schedule 'A' Section-XV (EXTERNAL WATER SUPPLY) (Ref pre priced Schedule attached separately)
16Lump sum price worked out by the contractor for Schedule 'A' Section-XVI (ROAD, PATH AND CULVERT) (Ref pre priced Schedule attached separately)
17Lump sum price worked out by the contractor for Schedule 'A' Section-XVII (SEWAGE DISPOSAL) (Ref pre priced Schedule attached separately)
18Lump sum price worked out by the contractor for Schedule 'A' Section-XVIII (AREA DRAINAGE) (Ref pre priced Schedule attached separately)
19Lump sum price worked out by the contractor for Schedule 'A' Section-XIX (RAIN WATER HARVESTING) (Ref pre priced Schedule attached separately)
20Lump sum price worked out by the contractor for Schedule 'A' Section-XX (DEMOLITION B/R AND E/M) (Ref pre priced Schedule attached separately)
21Schedule ‘A’ Section- XXI (MISCELLANEOUS ITEMS)INTERNAL ELECTRIC SUPPLY)
22S&F Surface/wall mounting LED batten luminaire with following specifications :-(a) System Power : 20W(b) Length : 4ft(c) Housing : Epoxy powder coated white extruded aluminium channel(d) Diffuser : Milky white Polycarbonate(e) Rated Voltage : 240V(f) Safe operating Voltage : 140V to 270V(g) Rated Frequecy : 50 Hz(h) Power Factor : ≥ 0.95(j) THD : ≤ 10(k) Operating Temp : - 10 deg C to + 45 deg C(l) Lumen Efficacy of LED : ≥ 120 Lm/W(m) System Luminous Efficacy : ≥ 100 Lm/W(n) CRI : ≥ 80 (o) CCT : 5700K(p) Driver : Integral SMPS based constant current type with short circuit , surge voltage protection upto 2.5 KV. (r) IP rating : 20(s) IK rating : 03(t) Average LED life : 50000 Hrs
23S&F Surface/wall mounting LED batten luminaire with following specifications :-(a) System Power : 10W(b) Length : 2ft(c) Housing : Epoxy powder coated white extruded aluminium channel(d) Diffuser : Milky white Polycarbonate(e) Rated Voltage : 240V(f) Safe operating Voltage : 140V to 270V(g) Rated Frequecy : 50 Hz(h) Power Factor : ≥ 0.95(j) THD : ≤ 10(k) Operating Temp : - 10 deg C to + 45 deg C(l) Lumen Efficacy of LED : ≥ 120 Lm/W(m) System Luminous Efficacy : ≥ 100 Lm/W(n) CRI : ≥ 80 (o) CCT : 5700K(p) Driver : Integral SMPS based constant current type with short circuit , surge voltage protection upto 2.5 KV. (r) IP rating : 20(s) IK rating : 03(t) Average LED life : 50000 Hrs
24S&F Surface mounting LED Down Lighter luminaire with following specifications :-(a) System Power : 15W(b) Dia : 200mm(c) Housing : Pressure die-cast aluminium heat sink fitted in white finish polycarbonate housing. (d) Diffuser : Polycarbonate in opal finish(e) Rated Voltage : 240V(f) Safe operating Voltage : 140V to 270V(g) Rated Frequecy : 50 Hz(h) Power Factor : ≥ 0.95(j) THD : ≤ 10(k) Operating Temp : - 10 deg C to + 45 deg C(l) Lumen Efficacy of LED : ≥ 120 Lm/W(m) System Luminous Efficacy : ≥ 100 Lm/W(n) CRI : ≥ 80 (o) CCT : 5700K(p) Driver : Integral SMPS based constant current type with short circuit , surge voltage protection upto 2.5 KV. (r) IP rating : 20(s) IK rating : 03(t) Average LED life : 50000 Hrs
25S&F surface mounting LED Down Lighter luminaire with following specifications :-(a) System Power : 10W(b) Dia : 200mm(c) Housing : Pressure die-cast aluminium heat sink fitted in white finish polycarbonate housing. (d) Diffuser : Polycarbonate in opal finish(e) Rated Voltage : 240V(f) Safe operating Voltage : 140V to 270V(g) Rated Frequecy : 50 Hz(h) Power Factor : ≥ 0.95(j) THD : ≤ 10(k) Operating Temp : - 10 deg C to + 45 deg C(l) Lumen Efficacy of LED : ≥ 120 Lm/W(m) System Luminous Efficacy : ≥ 100 Lm/W(n) CRI : ≥ 80 (o) CCT : 5700K(p) Driver : Integral SMPS based constant current type with short circuit , surge voltage protection upto 2.5 KV. (r) IP rating : 20(s) IK rating : 03(t) Average LED life : 50000 Hrs
26S&F Wall mounted light fitting made up of Polycarbonate with B-22 base 15W LED Lamp, complete all as specified and directed.
27S&F in replacement LED building security light fitting complete with mounting bracket made out of light grade GI pipe 40mm bore 1.20 mtr long bend to shape including 02 Nos of 40x5mm FI clamps with GI bolt, nut, washer and 3-core copper cable connection from ceiling rose to light fitting. Specification of light fitting are as under :-(a) System Power : 35 W(b) Housing : Pressure die cast aluminium alloy having separete optical & control gear compartment, top opening, polyster powder coated after phosphochromate treatment (c) Optics : Polycarbonate UV stabilised with integrated lens(d) Light source : SMD LED module mounted on MCPCB(e) Rated Voltage : 240V(f) Safe operating Voltage : 140V to 270V(g) Rated Frequecy : 50 Hz(h) Power Factor : ≥ 0.95(j) THD : ≤ 10(k) Operating Temp : - 10 deg C to + 50 deg C(l) Lumen Efficacy of LED : ≥ 140 Lm/W(m) System Luminous Efficacy : ≥ 100 Lm/W(n) CCT : 5700K(o) Driver : Inbuilt SMPS based constant current type with protections for output open / short circuit , phase to phase, over voltage & surge voltage upto 10KV.(p) IP rating : 66(q) IK rating : 07
28Note for Srl Item No. 22 to 27 :- Make of light fitting & Driver shall be same and manufactutrer shall have in house NABL accredited lab.
29S&F Sheet metal enclosure distribution board double door Vertical triple pole and neutral (VTPN), AC, 440 volts, 06 ways with minimum 200 Amps rated copper bus bar for each phase, 2 neutral bar, 2 earth bar and cable ties metal door with IP 43 & IK 09 protection confirming to IEC 61439-3, along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing, suitable for 4-pole MCCB as incomer & MCB SP/TP as outgoing having rating as per load requirement, complete all as specified and directed
30All as per Srl item No. 28 here-in-before but 04 Way
31S&F Sheet metal enclosure distribution board confirming to IEC- 61439-3, single pole and neutral, AC, 240 volts, 6 way, with 100 Amps rated copper bus bar and metal double door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing, complete all as specified and directed. Note for Srl item No. 28 to 30 :-(i) MCCB & MCB shall be measured and paid separately under respective item of Sch.(ii) Make of DB, MCCB & MCB shall be same.
32S&F MCB confirming to IS/IEC- 60898-1(2002), AC, 240 volts, 10 KA breaking capacity including making connections by using suitable copper lugs of following ratings :-
33SP 63 Amp \\"B\\" curve
34SPN 10 Amp \\"B\\" curve
35SPN 16 Amp \\"B\\" curve
36S&F Blank Plate 1-module in DBs, complete all as specified and directed.
37S&F Bus bar chamber of approx dimensions 397x300x172mm, made of 1.6mm thick CRCA sheet powder coated, comprising of MCB TPN 63 Amp,10KA-01 No, Tin Plated ETP Copper bus bar 4-pole 100A rating, duly supported on DMC insulators, complete all as specified and directed.
38S&F Modular TV socket, complete all as specified and directed.
39S&F Commercial type Electric Chimney with SS 304 exhaust hood 2700x1800x450 mm with baffle filter including wet Scrubber - 5000 cfm double skin type with required GI ducting and volume control damper, heavy duty 3 phase 5.0 HP cap centrifugal blower with dynamically balanced MS impleller fixed over with suitable frame and base, complete all as specified and directed.
40INTERNAL WATER SUPPLY
41S&F 2 way Bib tap 15 mm bore, ISI marked inlet and 2 independent outlets each operated by its own individual handle, complete all as specified and directed.
42SUMMER APPLIANCES
43Supply, installation, testing & commissioning of Refrigerator electric driven single phase 240 V, 50 Hz, 310 Ltr capacity (or next higher cap), frost free, double door, CFC Free refrigerent, 5-Star rated, complete with all standard accessories, complete all as specified and directed.
44Supply, installation, testing & commissioning of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 270 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and directed.
45DG SET
46Supply, installation, testing and commissioning complete by manufacturer of OEM (Original Eqpt Manufacture) auto main fialure static Silent Diesel Engine driven generating set capable of delivering 82.5 KVA output, 415 volts (AC 3 Phase, 4 wire system of supply) 50 Hz at power factor 0.8 (Lag). The DG set shall consist of a Diesel Engine coupled through flexible coupling to a matching alternator and mounted on AVM pads on a common base frame installed in MoEF/CPCB approved acoustic enclosure, first filling of lubricant oil, radiator coolent, SMF battery etc. all as specified complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete and shall comprise of the following :-
47(a) ENGINE (PRIME MOVER). CPCB-IV + compliant Diesel Engine 1500 RPM of suitbale HP as recommended by manufacturer water cooled, 4-cylinder, In-line-4 stroke, Turbocharged aircooled, electronic governor, 12 Volts (of AH rating as per manufacturer specification) battery start, complete with fly wheel and all standard fittings/fixtures as per manufacturing practice including suitable engine control panel with tachometer, lub oil temp & pressure gauge, water temp guage and frequency meter (digital type) including safety shutdown contents) and also including self starter, dynamo, fuel tank etc and conforming to IS 10002, ISO 3046, BS-5514. The engine shall give electrical out put of 82.50 KVA at 0.8 PF (lag). (b) ALTERNATOR. AC alternator, self excited, self regulated, self ventilated, brushless design, conforming to IS/IEC: 60034-1, 3 Phase, 415 volts, 50 Hz, 4 wire system output 82.50 KVA PF 0.8 1500 RPM insulation class `H' enclosure IP 23/SPDP complete with AVR with ± 1.5% voltage regulation directly coupled to and match the above engine and capable for over load of 10% for one hr in 12 hr operation. (c) CONTROL PANEL (AMF PANEL) : Inbuilt control panel to match with the requirment of DG set and shall be manufactred with 14/16 gauge CRCA sheet and is powder coated for a weather proof and long lasting finish . The control panel consist of following parts as per manufactured norms: (i) PCC- key switch/ Autostart Generator set controller. (ii) Multifunction meter displaying the parameter as voltage current, frequency water oil pressure KVA,KW (iii) Contractors with HRC fuse of suitable rating,current transformers, AMF logic Battery Charger Aluminium Bus bar of suitable capacity indicating lamps. (iv) Standard foundation as per manufactrers specification anti vibration foundation pad of approved make & suitable capacity.
48(d) BASE FRAME. Made out of structural steel as per manufactur's recommended design/specications.(e) ACOUSTIC ENCLOSURE. Accoustic enclosure designed to meet stringent MoEF/CPCB norms of 75 dBA @ 1mtr at 75% load under free field conditions made of CRCA sheets and structural /sheet metal base frame with high quality noise absorbant anf fire retardant grade accoustic insulation material (foam) complying to IS: 8183 . Provision of LED light with door NO/NC contact, engine emergency stop push button, hinged door (with toughened glass on door shutter facing monitoring panel) locking and rain guard arrangement, thermostate to for automatic engine stop on increse of temp above set temp range.(f) CATALOGUES. Operation and Maintenance manual, spare parts list, overhauling manual - 01 setsNotes :- Rates are inclusive of the below provisions:-(i) PCC foundation as per manufacturer specifications. Foundation shall be at least 450mm above GL and extended 600mm on each side from base of DG set.(ii) Water/heater load test at site for 12 Hrs duration (1 Hr at 25% load, 1 Hrs at 50%,1 Hrs at 75% load, 8Hrs at 100% load, 1 Hr at load in excess of 10% of rated load) in presence of IEM / Rep of accepting officer with necessary artificial load , T&P and FOL etc.(iii) Periodical maintenance like A-Check, B-Check, C-Check, D-Check as per OEM maintenance manual including Lub oil change, filter replacement etc during Defect Liability Period .
49Supply, installation, testing and commissioning by OEM 13 Passengers Lift suitable to serve G+5 floors with AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories conforming to IS : 17900, simplex collective selective automatic & manual dual controlled operation with/without attendant, automatic centre opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors (opening size not less then 900 x 2000 mm), automatic rescue device (ARD) system, complete all as specified below and as directed :-
50Notes :- Lift OEM to submit detailed specification/design parameters, construction drawing of all components of lifts as per IS-17900 and as per latest ammendement for approval of GE before execution of work. (a) Type of Lifts : Passenger(b) No. of Passengers & Load capacity : 13 Nos & 884 Kg(c) Speed: 1.50 mtr/sec with single speed motor(d) Power Supply : 415 volts, 3 phase AC, 50 Hz(e) Type of Drive: AC variable voltage & variable frequency drive. (f) Type of Machine: Gearless permanent magnet & directly coupled horizontal traction machine (g) Car size (Inside): As per IS -17900.(h) Car and landing door at all floors : Automatic centre opening with VVVF, sliding type and stainless steel sheet not less than 1.5 mm having hair line finish (N-304) the car and landing doors.(j) Car enclosure: manufactured with stainless steel frame not less than 1.5 mm with Hair line finish (N-304) having stainless steel false ceiling with hair line finish, Internal lighting arrangement with PIR sensor automatic operation LED light fittings on automatically in human presence with in 05 mtr range complete internal ventilation system provided with concealed arial flow/cross flow fan with auto cut off system and stainless steel grill wire mesh for protection, looking mirror and hand rails as per OEM design.
51(k) Terminal buffers: Metal special spring buffers as per manufacturer specifications. (l) Door opening (Inside): protected by centre opening glass doors/ stainless steel doors with hairline finish doors with clear opening.(m) Counter weight shall be of cast iron as recommended by OEM as per IS(n) Car counter weight guide : guide rails of ‘T’ section mild steel as per OEM design as per IS(o) Flooring: Aluminum chequred plate 5mm thick complete(p) Signals :-(i) Combined luminous hall buttons with LCD/VFD hall position indicators at all floors.(ii) Vacuum Filled Display (LCD/VFD ) for car position indicator of stainless steel (iii) One Number car operating panel with luminous braille buttons with coloured LCD display.(iv) Car direction indicator in car & Landing.(v) Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery
52(q) Stops & Opening : Six landings ( All opening on same side).(r) Safety device : (i) Automatic rescue device (ARD)/automatic landing device to be operating with independent maintenance free batteries having suitable capacity. The batteries must have auto charging facilities. (ii) The ARD actuation time should be less than twenty second after failure of power supply and when ARD is operative the car should stop at the nearest floor and then open.(s) Operation: Simplex, full collective selective automatic operation with and without attendant.(t) Machine room :- Located above the hoist way. (u) Hoist way construction; RCC structure with brick wall construction.Total height from G/L to slab of Machine room can be seen at site before installation of lifts. (v) Control system shall be closed loop type.(w) Door shall have AC VVVF controlled door operator.(x) Faceplate shape shall be Rectangular and of stainless steel in hairline finish.(y) Civil work : Necessary civil work such as scaffolding in elevator shaft, cutting, making holes, grouting/welding barricading for all openings of elevators to avoid accidents & disturbances during pre and post erection of lift and making good disturbed surfaces, modifications to landing space to suit to car size, necessary foundation to machine, minor plastering of lift shaft wall etc and touch-up of white wash shall be applied on the lift shaft after completion of lift installation and all as per OEM recommendation/suggesting during execution of work.
53(z) Provn of travelling cable with copper conductor FRLS of suitable size & core or required wiring to intercom speaking,connect to complete cell and provn of through & other accessories as per OEM recommendation. (aa) Provn of governor and governor rope of suitable size, buffer springs as per manufacture's design, car cabin having powered doors and inspection box at top of the car cabin.(ab) Provn of safety guarding equipments such as 02 Nos Pit switches controller guarding pit pulley,guarding pit ladders,facia plate to cover free space between car cabin and hoist way & switches. Or as per OEM recommendation.(ac) Door sensor 81 beam, 2D infra red full length .(ad) Provn of “Press and speak” system to be connected with lift existing Intercom Exchange compatible with exchange.(ae) Do's & Don'ts chart to be installed inside the car cabin.(af) Evacuation process chart to be installed inside the car cabin. Incase when lift stuck in midway shaft. The letters/Numbers in chart should be luminous radium coloured to see in all day/night time.
54FIRE FIGHTING SYSTEM
55Supply, installation, testing and commissioning of Fire Pump set automatic electric control panel floor/wall mounted suitable for outdoor installation fabricated from CRCA sheet polyester powder coated of post man red colour and comprising of dry type fully automatic DOL starter, complete with contactors, push button, LED indication lamp, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc. suitable for following pump rating :-
56900 LPM, 36 mtr head.
57450 LPM, 30 mtr head.
58Supply and fixing for PN 1.6 rated air vent valve having brass body, cover, adopter, disc assembly & cap, stainless steel strainer, plastic float and 25 mm screwed threaded ends suitable for maximum operating temperature 100 °C installed on all high points in the water piping system to automatically remove the trapped air with necessary accessories, complete as specified and directed.
59Supply and fixing FM approved, UL listed, 6 kg capacity multipurpose dry chemical powder (ABC) type (IS: 15683-2006) fire extinguishers consisting of welded MS cylinderical body fabricated from 1.6 mm thick MS sheet internally protected with anticorrosive treatment and hydrolically tested, extinguishers externaly painted with red enamel and fixed on wall with bracket complete with initial filled / charged, complete all as specified and directed.
60Supply and fixing FM approved, UL listed, CO2 type fire extinguisher of 4.5 Kg capacity with steel cylinder with a discharge valve and confirming to (IS: 15683) extinguishers shall be painted with red enamel and fixed on wall with bracket complete with initial filled / charged, complete all as specified and directed.
61Supply and fixing 6 Ltr capacity pre engineered Linear heat detection LHS cable operated wet chemical based fire extinguisher system of indirect release low pressure( ILP) complete with CE approved MS cylinder fitted with automatic valve, low pressure switch for monitoring system activation, pressure Gauge , slip-on push-in tube connector, wet chemcal , mounting brecket, other accesories required viz a) Providing Flexible linear pneumatic heat detection cable 120 degree UL listed, b) Proving indirect release low pressure (ILP) system with Discharge SS pipes, Cross-Pattern Discharge (4) nozzle discharge connector , fitting valve etc c) Providing on panel, manual release, hooter, heat detectors etc., complete all as specified and directed.
62Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete all as specified, directed and comprising of the followings :-(i) 10 Zone panel for fire alarm system, 250 Watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required - 2 Nos.(one to act as standby) (ii) Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set.(iii) Announcement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc. complete as required -1 set.(iv) Amplifier change over switch for inter changing amplifier -1 No.(v) Monitor panel for loudspeaker complete with output selector ON/OFF switch, fuse, visual indications etc. complete as required- 1 No.(vi) Gooseneck microphone with stand and ON/OFF switch- 1No.(vii) Main ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters, terminal blocks etc. complete as required -1 set.(viii) Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos.12 volt, 60 AH each sealed maintenance free batteries -1 set.
63Supplying, installation, testing & commissioning of fire fighter telephone handset suitable for 2-way comminication, complete all as specified and directed.
64Supplying, installation, testing & commissioning of fire fighter telephone jack suitable for 2-way communucation, complete all as specified and directed.
65Supply & drawing through existing conduit annealed copper conductor cable sheathed 2 core 1.5 Sqmm HFFR, PVC insulated RED in colour, including termination and ferruling, complete all as specified and directed.
66Supplying and drawing through existing conduit 1-pair 0.5 mm dia HFFR PVC insulate annealed copper conductor, unarmourd telephone cable including termination and ferruling, complete all as specified and directed.
67Supplying and fixing of steel conduit 20mm NB along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required, complete all as specified and directed.
68Supply and fixing of the following type of signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners, complete all as specified and directed of the following sizes :-
69Sign of size 300 mm X 150 mm reading 'EXIT' in 12.5 mm block letters in Green and white background, properly spaced to provide good legibility located directly in corridor near to each staircase and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level. These lights shal emit maximum light required even during electricity supply or in black out period with high energy efficiency manufactured using superior quality aluminium extrusion body raw material. It shall meet following technical/operational requirements :(i) Product material : Aluminium alloy extrusion.(ii) Product Finish : Matt Black / Snow White finish after phosphochromate treatment.(iii) Wattage - 5 Watt(iv) Mounting : Surface / Hanging.
70Sign of size 500 mm x 500 mm, posted and maintained within each stair enclosure on every floor, indicating the 'Floor Number' in bold type and at 75 mm high numerals in red and white background, securely attached to the stair side of the door in a way that the bottom of the sign is not above 1.5 m from the finished floor level.
71Sign of size 450 MM x 150 MM reading 'FIRE POINT' in 12.5 mm block letters in White and Red background, properly spaced to provide good legibility located directly in corridor near to each Manual call point/Fire Extinguisher and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level.
72Sign of size 150 MM x 600 MM reading 'FIRE POINT' posted in and maintained at each lift landing and on side of stair way door from where egress is to be made on every floor, indicating \\"STAIRCASE/LIFT\\" by an alphabetical letter in bold type and 75mm high letter in red and white background.
73HOT WATER SUPPLY
74Supply and fixing 25mm dia CPVC Ball valves for cpvc pipe, Half round, high pressure with crutch or butterfly handle, screwed both ends for cpvc pipe or for unions and fixed, complete all as specified and directed.
75Supply and fixing 20mm dia CPVC Ball valves for cpvc pipe, Half round, high pressure with crutch or butterfly handle, screwed both ends for cpvc pipe or for unions and fixed, complete all as specified and directed.
76M&L for fabrication of water suction/delivery header pipe using C-Class MS pipe of 50mm size/dia with insulation glass wool as required at site, provided with both end flanged dead plugs for future extensions have in one incoming of size 25mm and five outgoing of size 25mm, complete all as specified and directed.
77S&F Rotational moulded polyethylene water storage tank (cylindrical vertical tank with close top) of 300 Ltr capacity, triple layer as make up water tank including 20mm dia brass float valve, complete all as specified and directed.
78M&L for staging for make up water tank made of angle iron stand of 75x75x6 mm with 03 RM height duly painted with 2 coat of synthetic enamel paint over a coat of zinc oxide primer alongwith 50x6mm MS flat iron 8 nos bottom of PVC tank and 50x50x6mm cross angles in all sides, top & bottom, height of stage should not less then 02 mtr from Collector level and grouted in PCC 1:2:4 type B-1 (using 20mm graded stone aggregate), complete all as specified and directed.
79CENTRAL AIR COOLING
80Supply, installation, testing and commisioning of Ductable Air Cooler (Evaporative Cooling System) modular unit comprising of weather & shock resistant UV stabilized high grade engineering plastic body, four side high quality air pre-filter to protect honey comb cooling pad 100 mm thick with cooling surface area 2.60 Sqm, minimum cooling efficiency 80%, top & bottom discharge option as per site conditions, ISI marked heavy duty 3-phase, 415 V, 50 Hz, Copper wound, single speed fan motor of minimum capacity 1.5 KW, fan dia 620 mm suitable to produce 14700 CFM, low sound,air flow upto 1500 Sqft, complete in all respects including water and electric connections, complete all as specified and directed. Note : Installation, commissioning and maintenance during the Defect Liability Period shall be carried out by the contractor through the original manufacturers of the machine/ equipment.
81Supply, installation, testing and commisioning of Ductable Air Cooler (Evaporative Cooling System) modular unit comprising of weather & shock resistant UV stabilized engineering plastic body, four side high quality air pre-filter to protect honey comb cooling pad 100 mm thick with cooling surface area 3.60 Sqm, minimum cooling efficiency 80% top & bottom discharge option as per site conditions, ISI marked heavy duty 3-phase, 415 V, 50 Hz, Copper wound, single speed fan motor of minimum capacity 3.0 KW, fan dia 710 mm suitable to produce minimum 23950 CFM, low sound,air flow upto 2500 Sqft, complete in all respects including water and electric connections, complete all as specified and directed.Note : Installation, commissioning and maintenance during the Defect Liability Period shall be carried out by the original manufacturers of the machine/ equipment.
82Supply & fixing ABS plastic suppply Air Grills, having double deflection adjustable blades, specially engineered grill for upto 2X longer air flow & wider angle coverage and upto 50% less sound including nuts, screws, rubber gasket etc. to make the system, complete all as specified and directed.
83Supply and fixing Flexible duct connector with air delivery side of cooler made of durable fire retardant fabic Canvas, complete all as specified and directed.
84Material & labour for mild steel work as in iron frame stand for mounting of machine & fixing on location all as per the site requirement made out of angle iron of size as per recommendation of manufacturer including foundation where necessary, cutting, welding, required PCC foundation for grouting support, painted with 2 coats of weather proof synthetic enamel paint over a coat of zinc oxide primer, complete all as specified and directed.
85Supply and fixing Control wiring with 5 x 4 Sqmm FRLSH PVC round insulated and sheathed wire, ISI marked featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through rigid non-metallic PVC concealed/surface conduit medium grade 32 mm dia confirming to IS - 9537 (Part 3), complete all as specified and directed.
86Supply & fixing Industial wall mounted plug socket three phase 16 Amp rating 3P+N+E suitable for IP 67 degree of protection, complete all as specified and directed.
87M&L for duct insulation 19mm thick XLPE (Cross linked Polyethylene) factory laminated with aluminium foil duly provided with external protective layer of woven fiberglass cloth fixed with a UV resistant weather proof polymer coating. Joints to be sealed with high stength aluminium foil tape, complete all as specified and directed.
88BOREWELL WORKS
89M&L for carrying out Geophyical Electrical Resistivity Survey of proposed bore well site to investigate subsurface geological properties required for underground water exploration including collection of data, its interpretation & to submit detailed report to Engr-in-Charge. Note : Survey to be carried out through a NABL accredited Lab only.
90M&L for Trial bore holes of 200 mm dia in any type of soil/starta including hard stone boulders by means of any method by deploying combination of rig unit as per site conditions, complete all as specified and directed.
91Drilling, reaming and enlargement of trial bore dug under Srl item No.75 here-in-before upto 350 mm dia bore below existing ground level by deploying DTH rig unit, complete all as specified and directed for following depths:-
92upto 60 mtr depth
93Below 60mtr and upto 150 mtr depth.
94M&L for electric logging of complete tubewell with computerized electric logger machine and submission of report alongwith its interpretation, complete all as specified and directed.
95Supply, assembling, jointing, lowering and fixing in position of 200 mm NB dia ERW MS plain end casing pipe, wall thickness 5.4mm, Fe-410 grade, IS-4270 : 2001 marked duly welded with coupler ring (welding to be done through out the circumference of the pipe and coupler ring both sides), complete all as specified and directed.
96Supply, assembling, jointing, lowering and fixing in position of 200 mm NB dia ERW MS less plain end slotted pipe, 7.04 mm wall thickness, Fe-410 grade, IS-8110:2000 assembled and lowered as per location including cutting welding as required complete, complete all as specified and directed.
97Supply, fixing and lowering into bore holes centring guides madeout of 16 mm dia MS bar ring suitable for 200 mm bore housing/casing pipe, complete all as specified and directed.
98Supply and fixing of MS bail plug 200 mm dia size, complete all as specified and as directed.
99Supply and fixing Housing clamp 90 cm long 20 cm wide out of 20 mm thick MS plate for 200 mm dia casing pipe with necessary MS bolts, nuts and washers at ground level in PCC (1:2:4) type B1 using 20 mm graded stone aggregate in block, complete all as specified and directed.
100Supply and packing with Pea gravel of 3.35 mm to 4.75 mm size as per IS-4097:2008 approved quality as ordered to packed around the casing and slotted pipe in bore well, complete all as specified and directed.
101Development of tube well by compressed air with compressor of minimum capacity of 250 PSI suitable to remove sediment from water well upto 5 PPM as per IS: 11189:2020 followed by pumping by lowering submersible pump set of oversize to clear the water upro potable standards, complete all as specified and directed.
102Yield test of bore well by continuosly pumping for to determine safe pumping yield by V-notch method, complete all as specified and directed.
103Supply lowering testing and commissioning of energy efficient submersible pump set complete of suitable for discharge 180 LPM and head 80 to 100 mtr with suitable cap of electric motor 415 volt 3-phase with stainless steel body and SS impleller, complete all as specified and directed.
104Supply and fixing Galvanised iron column pipe heavy grade IS-1239 marked 80 mm bore x 3 mtr long both end flanged joint duly screwed and welded with pipe suspended in deep bore well with groove/cut for submersible cable including rubber gasket and GI nut, bolts on both ends, complete all as specified and directed.
105Supply and fixing Submersible cable flat copper conductor PVC insulated and PVC sheathed 4.0 sqmm 3-core 415 V, 1100 V grade fixed to column pipe with suitable clamps jointing material, complete all as specified and directed.
106Supply & fixing Well cap made out of MS PGI 6mm thick suitable for 200mm dia casing pipe with locking arrangement on top of casing pipe, complete as specified and directed.
107Supply and fixing Swing Check type Non Return valve 80 mm dia PN 1.0 conforming to IS:5312 (2004) complete with set of EPDM rubber gasket, GI nut & bolt with washer, complete all as specified and directed.
108Supply and fixing Strainer Y type, flanged end of class 1.0 PN, 80mm dia with perforated screen mesh of SS conforming to IS : 12785 (1994), complete with set of EPDM rubber gasket, GI nut & bolt with washer, complete all as specified and directed.
109Supply and fixing Water Meter, flanged ends, woltman type, IP-68 of size 50mm having dry dial removal mechanism for easy cleaning complete with set of EPDM rubber gasket, GI nut & bolt with washer, complete all as specified and directed.
110Supply and fixing Cast iron air release valve with single air outlets, conforming to IS 14845 of size 50 MM dia bore and fixing up in cast iron water supply mains of size 50 mm dia, complete all as specified and directed.
111M&L for water potability chemical & bacteriological analysis test from a govt approved lab inculding collecting the water from the given point in sterelized glass/plastic jar, taking sample to the lab for testing and submiting the report, complete all as specified and directed.
112M&L for bore assembly chart in laser colour print duly laminated, complete all as specified and directed.
113M&L for bore strata box made of hard board with cabinet to place different bore soil strata in plastic transparent boxes with lockable door frame with glass and hanging arrangement in pump house wall, complete all as specified and directed.
114Supply, installation, testing and commissioning of LT Panel board out door type made out of 3.15 mm CRCA Sheet cubical type totally enclosed wheather dust and vermin proof with front and rear opening , 415 Volts 3 phase 4 wire 50 Hz having 4 pole aluminium bus bar capacity 40 Amps insulated with heat shrinkable sleeves RYB and supported on SMC/DMC insulator including internal wiring with FRLS copper wire powder coated including connecting all in coming and out going cable feeders with necessary lugs ferrules etc . The panel should have angle iron support of size 40x40x6 mm with 4 legs of 750 mm long (300 mm grouted in PCC and 450 mm above GL) on the base all around including PCC foundation support, well finishing with cement mortar, complete all as specified, directed and comprising of the following switchgear and accessories :-(a) INCOMING :-(i) MCB TPN 40 Amps,415 V, 10 KA -01 Nos.(ii) Digital type Multifunctional meter to measure Amp,Voltage-01 No(b) OUT GOING :-(i) MCB TPN 40 Amps, 415 V, 10 KA - 01 Nos. (ii) MCB SPN 10 Amp 240 V- 02 Nos (iii) Dry type Automatic Star delta suitable for 3-phase Submersible P/set upto 7.50 HP motor complete with safety protection against over/under volatge, single/reverse phasing-01 No
115Making hole below the road/hard standing by mannaul auger or hand drill without damaging road for inserting pipe upto 100 mm dia, complete all as specified and directed.
116EXTERNAL ELECTRIC SUPPLY
117Supply, installation, testing and commissioning of 11 KV outdoor Compact Sub Station (CSS), type tested assembly as per latest IEC standard 62271-202, OEM make totally factory assembled (no-walk in type) comprising of 11KV 1 way RMU – 01 No, 11/0.433KV , 315 KVA with eco friendly Synthetic Easter Oil cooled transformer, 433 V rating LT distribution panel appended as below :-
118MV COMPARTMENT : 11KV, 630A, indoor type non-extensible, SF6 gas insulated Ring Main unit with sealed pressure system criterion in accordance with IEC: 60298, 62271-202, IAC category IAC-AFL with following specifications :(a) Rated Voltage – 12 KV(b) Rated power frequency voltage – 28 V(c)Rated lightning withstand voltage – 75 KV(d) Rated current rating – 630 Amp(e) Rated short time current rating – 21 KA / 3sec(f) Rated short time current making rating – 50 KA(g) Rated internal arc rating – 21 KA / 1 sec for tank and cable box category IAC-AFLR(h) RMU shall be provided with protection CTs rated 20/1 Amp , class-5P10accuracy, 2.5VA burden(j) Self powered protection relay with OC+EF for transformer with serial port for communication on modbus protocol(k) Dead short circuit life of VI- 40Nos.TRANSFORMER : (a). Rating – 315 KVA, 11/0.433KV(b) Standard – IS 1180 (part-I) 2014, & 2026(c) Vector Group – Dyn11(d) Cooling - ONAN(e) Winding - Copper(f) Magnetic Core – Prime grade of M4 or better(g) HV Power Frequency (KV rms) – 28 KV(h) HV Impulse withstand voltage (KV peak) – 75 KVp
119(j) Energy Efficiency Level – 3 (as per IS:1180 Part- 1 2014 amended upto date)(k) % impedance - 4.5% with IS tolerance(l) Temperature Rise – 40/45 deg C (Max) for Oil / Winding.(m) Tap Changer- OLTC, 7 steps each of 2.5% to vary voltage from +5% to -10%(n) Standard Accessories - As per IS:1180(Part-1): 2014LV COMPARTMENT : LV compartment with IP:54 designed for 40 degree ambient temperature. The is modular, freestanding, floor mounted made of CRCA sheet 2.0mm thick powder coated and comprising of the following switchgears:-INCOMING(a) Bus bar 4-pole 433V, 630A rating of electrolytic grade aluminium with coloure coded heat shrinkable sleeves. (b) MCCB 4-pole, 415V, 630A, 50KA (Ics=100% Icu) rating confirming to IEC: 60947-2 with microprocessor based release, adjustable over load setting (0.7-1xIin), adjustable short circuit setting (5-10xIr), adjustable neutral protection, front indication LED- 01 No (c) LED type phase indicator (RYB) – 01 Set(d) Digital type multifunctional meter (A,V,Hz,KWH,PF) - 01 No.OUTGOING(a) MCCB 4-pole, 415V, 125A, 16KA (Ics=100% Icu) rating confirming to IEC: 60947-2 , adjustable over load setting (0.7-1xIin), adjustable short circuit setting (5-10xIr), adjustable neutral protection, front indication LED - 01 No (for APFC Panel) Please Enable Macros to View BoQ information
120(j) Energy Efficiency Level – 3 (as per IS:1180 Part- 1 2014 amended upto date)(k) % impedance - 4.5% with IS tolerance(l) Temperature Rise – 40/45 deg C (Max) for Oil / Winding.(m) Tap Changer- OLTC, 7 steps each of 2.5% to vary voltage from +5% to -10%(n) Standard Accessories - As per IS:1180(Part-1): 2014LV COMPARTMENT : LV compartment with IP:54 designed for 40 degree ambient temperature. The is modular, freestanding, floor mounted made of CRCA sheet 2.0mm thick powder coated and comprising of the following switchgears:-INCOMING(a) Bus bar 4-pole 433V, 630A rating of electrolytic grade aluminium with coloure coded heat shrinkable sleeves. (b) MCCB 4-pole, 415V, 630A, 50KA (Ics=100% Icu) rating confirming to IEC: 60947-2 with microprocessor based release, adjustable over load setting (0.7-1xIin), adjustable short circuit setting (5-10xIr), adjustable neutral protection, front indication LED- 01 No (c) LED type phase indicator (RYB) – 01 Set(d) Digital type multifunctional meter (A,V,Hz,KWH,PF) - 01 No.OUTGOING(a) MCCB 4-pole, 415V, 125A, 16KA (Ics=100% Icu) rating confirming to IEC: 60947-2 , adjustable over load setting (0.7-1xIin), adjustable short circuit setting (5-10xIr), adjustable neutral protection, front indication LED - 01 No (for APFC Panel) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57823491
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 14.62 Crore
LAST DATE 04-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Providing Of Otm Accn (200 Or) At Rrrc Under Ge (P) East Delhi Cantt-10
Basic Detail
Tender No CEDZ/TOKEN-09 OF 2026
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 12 Nov 2026
Submission Date 04 Dec 2026
Open Date 09 Dec 2026
Finance
Tender Value 14.62 Crore
Tender Fee 3000
EMD 10.56 Lakhs
Exemption Available
Document List
1drawing83217.pdf
54c80eb3-a082-4a02-836e-5cd8b158248d.html
BOQ_888007.xls
Tendernotice_1.pdf
uploadtender.rar

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 19, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Dec 04, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 12 days
Dec 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Dec 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
pdf

1drawing83217.pdf

html

54c80eb3-a082-4a02-836e-5cd8b158248d.html

xls

BOQ_888007.xls

pdf

Tendernotice_1.pdf

rar

uploadtender.rar

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender