Housing Urban and Rular Development Local Bodies Closing in 6 days TDR #57822167

Tender For Improvements Of Multi Purpose Evacuation Centre With Community Hall At Kuttam Government Higher Secondary School In Kuttam Village In Kuttam Panchayat In Radhapuram Panchyat Union

Issued by Local Bodies · Tirunelveli, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
08 Oct 2026
6 days left
EMD
9000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tirunelveli → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Improvements Of Multi Purpose Evacuation Centre With Community Hall At Kuttam Government Higher Secondary School In Kuttam Village In Kuttam Panchayat In Radhapuram Panchyat Union

BOQ

Name of Work:- Improvements of Multi Purpose Evacuation Centre with Community Hall at Kuttam Government higher secondary School in Kuttam village in Kuttam Panchayat in Radhapuram Panchyat Union
Sl. No. Item Description
1Improvements of Multi Purpose Evacuation Centre with Community Hall at Kuttam Government higher secondary School in Kuttam village in Kuttam Panchayat in Radhapuram Panchyat Union
2Dismantling of Pressed Tiles & Weathering Course including all cost etc complete (PWD SOR 25-26 W-0037)
3Damp proof course in cement mortor CM1:3 - 12mm thick with water proofing compound at 2 % by wt of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers.
4Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
5Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
6Supply and fixing of 1.0 HP Monoblock pumpset including all cost etc complete (PWD SOR M-1064)
7European Water Closet with P or S Trap with Double Flapped Seat and Seat Cover with Brass Hinges and 10 litre capacity PVC Low Level Flusing Tank with all internal fitting (PWD SOR M0532)
8Supplying and fixing solid core flush shutter of following type with thickness with necessary T.W. internal lipping alround conforming to IS 2202 1(1999) including cost of wind appliances and furniture fittings such as 3 Nos SS 304 Grade Butt Hinges of size (125mm x 30mm) , 2 Nos .300x12mm aluminium tower bolt 1 No. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 2 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete complying with standard specification and as directed by the departmental officers - Single leaf.
9Single Leaf
10Labour Charges for replacing Fibre glass sheet in Excisting MS window The rate includes cost of fibre Glass Labour Charges etc. Comp
11Supplying and fixing PVC Rain water down fall pipes of following dia meter etc., complete.
12Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
13Supplying and fixing Pin Headed Glass Pans 3mm thick :
14Water supply arrangement
15Drilling of 150mm dia deep borewell in overburden soil including labour charges and transportation charges
16Supply and delivery of 150mm dia CS casing pipe(TWAD SOR M-1605)
17Supply and delivery of 50mm UPVC Column pipe.
18Supply and delivery of 3 phase 2HP submersible motor of duty condition 50Lpm x 40m head (TWAD SOR M-1604)
19Supply and delivery of 2HP 3 phase panel board (TWAD SOR M-1909)
20Supply and delivery of 75mm 4KSC PVC Pipe
21Supply and delivery of 40mm PVC Pipe (PWD SOR M-0878)
22Supply and delivery of 32mm PVC Pipe
23Supply and delivery of 25mm PVC Pipe
24Earthwork excavation and depositing on bank with initial lead and lift of 10m including all cost etc complete.
25Refilling with excavated soil other than sand including all cost and all labour charges etc complete
26Laying and jointing of 40mm, 32mm & 25mm PVC Pipes and specials etc complete.
27Supply and delivery of 4sq.mm 3 core copper cable
28Labour charges for erection of new 5HP submersible pump set in the borewell and commissioning
29Supply and delivery of Nylon rope. For bore well
30Electrical Arrangements
31Wiring with 2 X 1.5 Sq.mm (22 / 0.3) PVC insulated SC unsheathed Copper conducutor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3 mm thick Hylum sheet cover with TW box And 5 A FT switch with continuous earth connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC Open Light point / fan point (For electronic Regulator) SD 18
32Light Point
33Fan Point
34Wiring with 2 X 1.5 Sq.mm (22 / 0.3) PVC insulated SC unsheathed Copper conducutor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 mm X 100 mm X 113 mm TW switch box with 3 mm thick Hylum sheet cover for 5 A 3 pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for concealed PVC plug point SD 36
35Supply and fixing of WT bulk head fitting suitable with guard and 15 W (100W) LED bulb SD 85
36Supply and fixing of single box type 4'40 W flu fitting complete with copper choke and condensor with conduit pipe suspension from the ceiling with PVC unsheathed copper leads from terminals tot he fitting with tube SD88
37Supply and fixing of 1200 mm ( 48\\") AC ceiling fan complete with stepped electronic 300 W regulator with 300 mm down rod on the existing clamp. SD 110 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57822167
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 08-10-2026
Authority
Authority Name Rural Development And Panchayats Department
Work Description Tender for Improvements Of Multi Purpose Evacuation Centre With Community Hall At Kuttam Government Higher Secondary School In Kuttam Village In Kuttam Panchayat In Radhapuram Panchyat Union
Basic Detail
Tender No GENERAL FUND 2026-2027
Bidding Type Tender
Location
City Tirunelveli
State Tamil Nadu
Key Dates
Publish Date 01 Oct 2026
Submission Date 08 Oct 2026
Open Date 09 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 9000
Exemption Not Available
Document List
2fbef576-a333-489a-8261-9485706bcb62.html
BOQ_853432.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Oct 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

2fbef576-a333-489a-8261-9485706bcb62.html

xls

BOQ_853432.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders