Tender For special Repair To Oh Lt Line And Convert Into Up Gradation Cable With Connected Items At Fts Banda Of 17 Punjab At Mil Stn Bhuj Under Ge(A) Bhuj.
Tender Value
35.92 Lakhs
Estimated cost
Bid Submission
21 Oct 2026
18 days left
EMD
71840
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kachchh → Gujarat
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair To Oh Lt Line And Convert Into Up Gradation Cable With Connected Items At Fts Banda Of 17 Punjab At Mil Stn Bhuj Under Ge(A) Bhuj.
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc for laying of cables, erection of poles, struts/ stays etc not exceeding 10 sqm on plan and getting out in soft loose soil complete all as specified and directed. |
| 2 | Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and directed. |
| 3 | Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils complete all as specified and directed. |
| 4 | M & L for sand filling in trenches for cushioning of LT cables punning after filling complete as specified and as directed. Note: Punned thickness shall only be measured and paid |
| 5 | Supply and lay un-reinforced precast concrete cable cover , class , LV , Type I flat size 250 x 150 x 40 mm laid dry in treches over under ground cables complete all as specified and directed. |
| 6 | S & F GI pipe, light grade, of size 80 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, for cable protection complete all as speicifed and directed. |
| 7 | S & F GI pipe, light grade, of size 50 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, for cable protection complete all as speicifed and directed. |
| 8 | Dismantaling of any type and size ACSR conductor complete all as specified and directed. |
| 9 | Dismantaling of stay assembly including demolation of concrete etc complete all as specified and directed. |
| 10 | Dismantaling of insulator any size and any type complete all as specified and directed. |
| 11 | Dismantaling of cross arm of MS chanel or angle sections any type any size etc complete all as specified and directed. |
| 12 | Disconnecting, taking out, removing old existing unserviceable LT cable, overhead service cable of any size etc complete all as specified and directed. |
| 13 | Supplying ,Laying , jointing and testing XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade of size 10X 2C laid in trenches/ducts, floors, fixed to walls etc complete all as specified and directed. |
| 14 | - ditto- here in before Item 13 but of size 4C core 10 Sqmm |
| 15 | - ditto- here in before Item 13 but of size 4C core 16 Sqmm |
| 16 | - ditto- here in before Item 13 but of size 4C core 25 Sqmm |
| 17 | - ditto- here in before Item 13 but of size 3.5C core 50 Sqmm |
| 18 | - ditto- here in before Item 13 but of size 3.5C core 70 Sqmm |
| 19 | - ditto- here in before Item 13 but of size 3.5 core 95 Sqmm |
| 20 | - ditto- here in before Item 13 but of size 3.5 core 185 Sqmm |
| 21 | Supply, installation, testing and commissioning weather and vermin proof L.T. feeder pillar box CPRI approved factory fabricated out door,double door cubicle/KIOSK type totally enclosed outer cage made out of 3.0 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm with height not less than 0.8 meter, suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, IP 65 , Gasket insulators, fasteners etc with hinged panel doors (covers) on two sides with handles , bottom gland plate and locking arrangement with latch door mechanism in front and back door, consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper busbar or conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and suitable capacity busbar , Air vent , PCC foundation 1:2:4 for foundation etc comprising for the following :-Location: MFP Near Transformer |
| 22 | (a) Copper Bus Bar 600 A rating for 3 Phase and 300 A for Neutral - 01 Set |
| 23 | (b) MCCB 4 Pole thermal magnetic release 415 volts 400 A 36 KA,Ics=100%Icu -01(incoming), |
| 24 | (c) MCCB 4 pole thermal magnetic release 250 A, 36 KA,Ics=100%Icu -04 Nos |
| 25 | (d) MCCB 4 pole thermal magnetic release 63 A, 16 KA ,Ics=63%Icu ,-02 nos |
| 26 | (e) Voltmeter digital type 0-500 V with inbuilt selector switch-01 No |
| 27 | (f) Ammeter digital type 0-500 A with in built selector switch and CTs-01 No |
| 28 | (g) 3 Line multifunctional meter-01(Nos) |
| 29 | All as per item no 21 here in before but LT Panel consisting of following items (Near Mess ) |
| 30 | (a) Aluminiium Bus Bar 400 A rating for 3 Phase and 200 A for Neutral - 01 Set |
| 31 | (b) MCCB 4 Pole thermal magnetic release 415 volts 250 A 36 KA,Ics=100%Icu , -01(incoming), |
| 32 | (c)MCCB 4 pole thermal magnetic release 415 Volts 63A, 16 KA, Ics=100%Icu , -05 |
| 33 | (d)MCB TPN 40 A -02 Nos (O/G) |
| 34 | (e) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three) |
| 35 | (f) Voltmeter ammeter digital type 0-500 V with inbuilt selector switch-01 No |
| 36 | (g) 3 Line multifunctional meter-01(Nos) |
| 37 | All as per item no 21 here in before but LT Panel consisting of following items (Near MI Room ) |
| 38 | (a) Aluminiium Bus Bar 400 A rating for 3 Phase and 200 A for Neutral - 01 Set |
| 39 | (b) Onload change over 250Amp 4pole at incoming -01 Nos |
| 40 | (c) MCCB 4 Pole thermal magnetic release 415 volts 250 A 36 KA,Ics=100%Icu , -01(incoming), |
| 41 | (f)MCCB 4 pole thermal magnetic release 415 Volts 100A, 16 KA, Ics=100%Icu , -02 |
| 42 | (f)MCCB 4 pole thermal magnetic release 415 Volts 63A, 16 KA, Ics=100%Icu , -06 |
| 43 | (g) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three) |
| 44 | (h) Voltmeter ammeter digital type 0-500 V with inbuilt selector switch-01 No |
| 45 | (j) 3 Line multifunctional meter-01(Nos) |
| 46 | Supply and fix feeder pillar box made out of 3.0 mm thickness CRCA heavy internal compartment thickness of 2mm including MS angle iron frame of size 40 x 40 x 5 mm including Incomer as MCCB 100A and 5 Nos outgoing as MCB TPN 40 Amp complete all as specified and directed. |
| 47 | Supply, installing ,testing and commissioing factory made and tested LT Outdoor Street/Flood Light Control Panel having platform mounted,suitable for 415 Volts 3 Phase and neutral 4 wire,50 HZ AC supply system shall be dust and vermin proof,protection class(IP-65) and made of CRCA sheet steel enclusure 3.15 mm thick suitable framework/Support made out of 40x40x5 mm MS Iron angle frame ,front opening type with aprons for cable entry,with proper ferrul and cable gland,internal wiring with PVC insulated multistranded copper conductor FRLS Cable of adequate size but not less than 4 sqmm,minimum 0.5 meter height from ground level,marking of outgoing area as per site, Air vent , PCC foundation 1:2:4 for foundation etc complete. Note : The contractor shall submit detail Schematic Layout of the Panel Board for approval from Engr-in-Charge before procurement.The scope of work also comprising of the following :-(i) RYB Phase indicating LED type -01 set. (ii) MCB TPN 40Amps 4 polez,10 KA,50 HZ,415 Volts-01 No (iii) Power contactor 3 Pole,40 Amps.50 Hz,415 Volts-01 No. (iv) Time switch Digital Type,one dial daily,240/415 Volts,50 Hz-01 No. (v) Auto/Manual selector switch 6A-01 No.(vi) RYB Phase indicating light LED Type -03 No. |
| 48 | M&L ,earthing complete for machinary / Equipment installed at power house / sub station with galavanised steel earth plate electrode of size 60 cmx 60 cmx 6 mm thick buried directly in ground ( earth pit not less then 2.25 m deep below the normal ground level ) with top edge of the earth plate not less then 1.5m below normal Ground level connected galvanised earth strip 32X6 mm by means of bolts, nuts, washerws and check nuts all shown in electrical plate No.5 of SSR Part- I connected to main board / disribution board complete .Earthing GI lead and GI protection pipe 15 mm dia light grade upto 7.5 m from earth pit connecting to machinary/ equipment, testing point, all as specified and testing on completion all as per directed. |
| 49 | Note :- (i) The unit rate shall also included for earth work in hard /dense soil , PCC type C-I (1:3:6) chamber , PCC 1:2:4 type B-I cover 50 mm thick reinforced with 8 mm dia TMT bars,150 mm c/c both ways, funnel with watering pipe 20 mm dia medium graded , GI protection pipe light grade 15 mm dia and wire mesh complete in addition to items No. 1(a) to (e) of preamble (notes) under sub heading earthing specified on SI page No. 389 of SSR Part - II.(ii) Earthing strip and GI protection pipe beyond 7.5 mtrs will be measured and paid separatelly if required under appropriate Schedule. (iii) Earthing shall be tested as specified in casul 19.137 of SSP PART - I 2009 , to the entire satisfication of Engr-in-Charge. (ii) On teting after complataion of earthing , if the desired earth resistance is not obatined the earthing wiil be re done by the contractor at his on risk and cost to the entire satisfaction of the Engr - in - charge. |
| 50 | M&L for road cutting of any thickness with depth of 0.6m depth and 0.1m width and laying of pipe and drawing cable and PCC 1:3:6 for road cutting all as per specfied and dirrected. |
| 51 | Supply and drawing through the pole for making connections to the light fittings, three core, PVC insulated and sheated, Heavy duty,1100 volts grade,multistranded copper conductor (FRLS) cable 3Cx1.5 sqmm complete all as specified and directed. |
| 52 | Supply and fixing PVC pipe 25/20 mm through FRP Junction to street light clamp on the pole including all connecting accessories to the pole complete all as specified and directed. |
| 53 | Supply and fixing PVC coated flexible pipe 40 mm for protection of cable etc complete all as specified and directed. |
| 54 | Supply and fixing cable junction box with new pole mounted polycarbonate cable junction box of size 300x200x105 mm or next higher size for street light with IP-66 protection, weather proof with metric knockouts for cable entry for outdoor installation with front door opening system, cable gland, cable terminal for incoming and outgoing cable according to cable size including terminals for one incoming and one outgoing cables of size 16/25 sqmm 4 core, tapping of 3 Core 2.5/1.5sqmm from terminals, with one MCB SP 6 Amp 240V AC with mounting on DIN rail, pole clamp of flat iron, nut, bolt and washers complete all as specified and directed. |
| 55 | Supply fix in repair, erecting and fixing in true vertical position, Prestressed cement concrete pole 9 mtr long confirming to IS-1678 (latest) with minimum cross sectional area 102 mm x 152 mm at top and 102 mm x 289 mm at bottom , class - 10 ,removing of old pole to side and taking down MS channels carefully and refixing of MS channel on new pole ,taking down of pin/disc insulator, ACSR conductor, street light fitting with bracket from old pole to new pole and refixing the same , restringing of old conductor as per site requirement , providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30cm in between 2 bands and numbering of poles, and numbering of the poles shall be done with synthetic enameled painted letter of shape & size complete( M&L)all as specified and directed. (Note -SSR part I clause No.19.5 & 19.52 and other relevant clauses of SSR refers for execution of work and poles shall be procured directly from the manufacturer mentioned in tender documents.) |
| 56 | M&L for taking down old damged PCC pole and carefully taking down street light fiitings, bracket, Aluminium conductor of any size and other connected items complete all as specified and directed. |
| 57 | Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m in depth and not exceeding 3.0m depth for foundation, laying of cable/pipe etc or for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in hard/dense soil complete all as specified & directed . |
| 58 | M&L for PCC 1:2:4 type B-1 using 20 mm graded aggregates as in copings, kneelers, apex stones, bed plates, kerbs etc., water troughs and the like including weathering, slightly rounded for chamfered angles and throating including necessary form work complete all as specified and as directed. |
| 59 | M&L for PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate in foundation, filling and mass concrete for poles/struts etc including necessary formwork as required complete all as specified and directed. |
| 60 | M&L PCC in mix 1:4:8 type D2 with 40 mm graded aggregate for poles / stays foiundation and fitting in mass concrete complete as specified and directed |
| 61 | Supply and fixing in replacement LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with system efficacy greater or equal to 120 lumen/watt, beam angle =120 degree complete with IP 66 and min IK07 protection with integrated surge protection 4kV to 10kV and optics designed for Road lightning ,PF>0.95 and IEC safety class 1 protection complete all as directed. Make : Philips/Bajaj/Havells |
| 62 | NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysOct 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓