Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #57821745

Tender For Maintenance Of External Ht Electric Supply Network In Akhnoor Mil Stn Under Ge (N) Akhnoor

Issued by Statutory Bodies & Commissions/Committees · Jammu, Jammu and Kashmir
Tender Value
49 Lakhs
Estimated cost
Bid Submission
22 Oct 2026
18 days left
EMD
98000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Maintenance Of External Ht Electric Supply Network In Akhnoor Mil Stn Under Ge (N) Akhnoor

BOQ

Name of Work:- MAINT OF EXTERNAL HT ELECTRIC SUPPLY NETWORK IN AKHNOOR MIL STN UNDER GE (N) AKHNOOR
Sl. No. Item Description
1Disconnecting and taking out existing HT indoor 11 KV VCBs from housing and cleaning, rubbing and overhauling the mechanical parts incl Greasing oiling replacement of UNSV trip coil, breaker charging motor, gear pinion, roller switch, Big gear etc and re-assembling the same after replacement as required and made the VCB serviceable including making all electrical connection and testing & calibration (IR Test, Continuity test, Tripping test of earth fault and Over current of panel ) alongwith control panel and control wiring, protection system and relays by primary & secondary injection system bank/battery chargers/DC system complete all as specified and directed by Engr-in-charge. Note :- (i): Any parts required for replacement to make the breaker serviceable will be measured and paid separately under appropriate item of Sch ‘A’ ( 03 to 12 ) as supply only but fixing charges of the parts replaced/repaired is deemed to be included in these item (ii) All other accessories excluded to be supplied and fixed (under item No 3 to 12) required for site work will be manage by the contractor at his own arrangement under this item. (iii) calibration & testing will be carried out by machine which will be arranged by the contractor under his own arrangement.
2Supply only the following items / spare parts ( item 03 to 12) suitable for indoor 11 KV metal clad VCB, 200/800 Amps capacity of any make - ABB, Electric Fied, CG, DVEPL dismantled/fixed under Sch ‘A’ item No. 01 here in above complete all as specified and directed :-
3Supply only Vacuum Interrupter bottal for indoor metal clad VCB panel complete all as specified and directed.
4Supply only bushing (Female) complete all as specified and directed.
5Supply only flexible connectors complete all as specified and directed.
6Supply only closing coil assembly 30/24 volts DC complete all as specified and directed.
7Supply only tripping coil assembly 30/24 volts DC complete all as specified and directed.
8Supply only heating element with thermostat switch 150 Watt compact type complete all as specified and directed.
9Supply only motor cut off limit switch complete all as specified and directed.
10Supply only spring charge motor, single phase suitable for spring charge motorised mechanism complete all as specified and directed.
11Supply only auxilary switch (6 NO + 6 NC ) complete all as specified and directed.
12Supply only 11 KV bus insulator of suitable for 11 KV VCB/OCB Panel complete complete all as specified and directed.
13Supply and fixing in replacement of metal /apoxy spout of indoor VCB panel for suitable model from HT panel ABB/Seimens/E Field/DVEPL of 11 KV substations complete all as specified and directed.
14Supply, fixing and testing in replacement of auxilary contactor suitable for CG circuit breaker of 33 KV compitable with breaker control circuit for reliable opration complete all as specified and directed.
15Supply, fixing and testing in replacement of Anti pumping relay ( APD-100) 10A V2.0 250 V AC /28V DC for 33 KV outdoor CG Circuit breaker complete all as specified and directed. ,
16Supply, installation, testing in replacement of Auto Spring Charging Motor suitable for out door 33 KV vertical circuit breaker,.Motor shall be of appropriate voltage 220 V DC / 230 V AC) and power rating as per existing CG breaker with capabllity of automatic spring charging within specified time and duty cycle of the breaker including wiring, mounting hardware, couplings, and accessories if required complete all as specified and directed.
17Supply, installation, testing in replacement of triping coil for 33 KV outdoor circuit breaker of voltage rating 220 V DC and power rating as per existing CG breaker with capabllity of automatic spring charging within specified time and duty cycle complete all as specified and directed.
18Supply, removal, repair/replacement, testing & commissioning of Vaccume interruptor bottle for vertical porcelain bushings of 33 KV outdoor circuit breaker (Crompton Greaves) at MRS yard by replacing Flashed bushing, installation of new suitable bushing, alignment, tightening and sealing. Insulation resistance, HV withstand, contact resistance and functional tests to be carried out after fixing. All materials, tools, labor, transportation and safety arrangements shall be included in the scope and Job shall be completed as per relevant IS/IEC standards and to the satisfaction of the Engineer-in-Charge
19Supply and fixing in replacement of Vacuum interrupter pulling rod suitable for ABB/CG/Seimens suitable outdoor circuit breaker complete all as specified and directed.
20M&L for Testing, calibration, functioning and servicing of 33/11KV, 3.15 MVA outdoor type transformer and control & Relay panel (Indoor type) along with checking control wiring, protection system complete all as specified and directed. Note:- calibration & testing will be carried out by machine which will be arranged by the contractor under his own arrangement.
21Disconnecting, dismantling and taking out of unserviceable current Transformer from HT installation complete & Supplying installing commissioning and testing of new current transformer, outdoor epoxy type, ratio 180/0.578 conforming to IS 2705/1992 ( Part I,II,III & IV), 50 Hz for HT 11 KV having insulation level class1-P10, IL-28KV/75KV(P) , burden of 15VA and breaking capacity 18.4 KA for 1.0 second and necessary thimbles nut bolts etc complete all as specified and directed
22Disconnecting, dismantling and taking out of unserviceable current Transformer from HT installation complete & Supplying installing commissioning and testing of new current transformer, outdoor epoxy type, ratio 300-150/5-5 A conforming to IS 2705/1992 ( Part I,II,III & IV), 50 Hz for HT 33 KV having Acuuracy Class/limit 5P/10 , burden of 20VA and breaking capacity 16 KA for 1.0 second and necessary thimbles nut bolts etc complete all as specified and directed
23Disconnecting & taking down existing unserveceable PT any description any position, and supply, fixing, installation and testing of PT outdoor type oil cooled, 33KV/ /3-110V/ /3-110V/ /3,H.S.V 33KV conforming IS : 3156/1992 , INSUL. LEVEL -70KV/170KVp. RATED VOL FACTOR 1.2 CONT & 1.5 times for 30 sec,burden-100VA, class-1.0, Earthed type complete all as specified and directed.
24Disconnecting & taking down existing unserveceable PT any description any position, and supply, fixing, installation and testing of PT Indoor type ,11 KV as per existing sample complete all as directed by engr in charge.
25Supply only HT 11 KV shunt capacitor of 74 KVAr rating with insulation level 28/75 suitable for HT 11 KV 3 phase capacitor bank of any make, dismantled/fixed under Sch ‘A’ item No. 32 here in above complete all as specified and directed .
26Taking down/disconnection the unserviceable existing cable any type and size from control wiring (VCB/ Control & Relay panel inddor to outdoor Circuit breaker / CTs/PTs Panel in 33 KV Yard, ) and supply and laying new cable through DWC pipes/ducts or on surface/walls PVC insulated sheathed, un-armoured, electric cable heavy duty with stranded copper conductor, 1100 Volt Grade of size 2.5 Sqmm 12 core Cu cable for control wiring of remote panel of 11 KV VCB including jointing and testing complete all as specified and directed.
27Supply, install, testing and commissioning in replacement of unserviceable numerical over current & Earth falt relay type aux voltage 20 to 110 volts AC/DC, CT rating 1A or 5A , with inbuilt master trip & TCS feature. Relay should have minimum 4 digital Binary Inputs and 6 Digital output contacts suitable for AC/DC operation universel type including wiring of the relay with 1.5 Sqmm PVC insulated unsheted copper wire with numbering tags, thimble, insulation material, nut bolts as per existing Cat part No of make L&T etc complete all as specified and directed.
28Supply & fix, connecting in replacement of UNSV Ammeter Digital type 144 sqmm with CT ration 100/5 and current rating 0-50Amps and selector switch for 11 KV panel complete all as specified and directed by Engr-in-charge
29Supply & fix, connecting in replacement of UNSV Voltmeter square type Digital of suitable size of capacity 0 to 15 KV PT Ratio 11KV/110Volt for 11 KV panel complete all as specified and directed by Engr-in-charge
30Supply & fix, connecting in replacement of UNSV Voltmeter selector switch 10A/440 Volt for 11 KV VCB Panel complete all as specified and directed by Engr-in-charge
31Supply & fix, connecting in replacement of UNSVAmmeter Digital type suitable size with CT ration 100/5 and current rating 0-50Amps and selector switch for 33 KV panel complete all as specified and directed by Engr-in-charge
32Supply & fix, connecting in replacement of UNSV Voltmeter square type Digital of suitable size of capacity 0 to 35 KV PT Ratio 33KV/110Volt for 33 KVpanel complete all as specified and directed by Engr-in-charge
33Supply & fix, connecting in replacement of UNSV Voltmeter selector switch 10A/440 Volt for 33 KV VCB Panel complete all as specified and directed by Engr-in-charge
34Supply & fix, connecting in replacement of UNSV 11 KV panel indicating lamp (AC/DC) fitting LED type suitable for 24 volt/30volt DC complete with base complete all as specified.
35Supply & fix, connecting in replacement of UNSV fixed contact with insulator 800 amps, 11000 volt for 11 KV VCB panel complete all as specified and directed
36Supply & fix, connecting in replacement of UNSV movable contact with insulator 800 amps, 11000 volt for 11 KV VCB panel complete all as specified and directed
37Supply & fix, connecting in replacement of UNSV Frequency meter 47 to 52Hz digital type with auxiliary supply voltage 230 Volt.
38M&L for preparation of surfaces of VCB Panel Board cubical in shape applying two coat of synthetic enamelled paint of approved colour including supplying and fixing PVC name plate indicating different cable/switch and other accessories, connections complete all as specified and directed.
39Supply, installation, testing in replacement of Battery Charger new components of 32 V DCDB cubicle viz. 2 pole DC MCBs, voltmeter, ampere meter, wiring, cabling, ferruling and termination with specification :- (a) Double pole MCB for controlling DC supply. (b) Digital Voltmeter DC, range: 0-50V DC. (c) Digital Ampere meter DC, range: 0-30A DC complete all as specified and directed.
40Dismantling existing old 30 VDC battery bank-1 & 2 and Supply, erection, wiring, testing and commissioning of new maintenance free 30 V DC battery bank-1&2 by providing 16 cells of 2.OV, 100 AH rating each and laying of new 2Cx16 sqmm copper cables, PVC sheathed, PVC insulated, armoured having core color code red and black in flexible conduit freuling and termination, complete all as specified and directed.
41M&L for Filtration and dehydration of transformer oil through filtration plant (Dehydration/centrifuging of transformer oil by means centrifuging machine electrically operated at site of installation of transformer in running condition of transformer including testing of transformer oil before and after centrifuging from top and bottom of transformer complete ) to improve the dielectric strength/insulation value of the transformer oil upto 65 KV/40 KV (RMS) at 2.5 mm gap and filling in transformer 33/11KV, etc complete all as specified and directed Note :- (a) The contractor shall obtain shut down orders in writing before commencement of the work from Engineer-in-charge (b) The contractor shall be hole responsible for wastage of existing transformer oil. (c) The contractor shall be solely responsible for any damages to the transformer during process of oil filtration. He is responsible for making good any damage to the transformer at his own cost without any extra cost to the department. (d) The contractor shall ensure that the conservator tanks are full to its level before commencement of dehydration process.(e) Additional qty of transformer oil if any required for making the oil level upto the requirement in transformer shall be measured and paid separately as supply and filling but its cost of heating shall be deemed to be included in the rate quoted for above item.
42Supply, and filling/topping up of transformer insulating oil EHV grade having dielectric strength 65 KV/40 KV (R.M.S) at 2.50mm gap low viscosity confirming to IS – 335H of 1983 in various capacity of transformer 33 /11KV, and 11/0.433 KV respectivelly complete all as specified and directed . Please Enable Macros to View BoQ information
43Supply, and filling/topping up of transformer insulating oil EHV grade having dielectric strength 65 KV/40 KV (R.M.S) at 2.50mm gap low viscosity confirming to IS – 335H of 1983 in various capacity of transformer 33 /11KV, and 11/0.433 KV respectivelly complete all as specified and directed . Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57821745
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49 Lakhs
LAST DATE 22-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Maintenance Of External Ht Electric Supply Network In Akhnoor Mil Stn Under Ge (N) Akhnoor
Basic Detail
Tender No CWE/JA-38/2026-27
Bidding Type Tender
Location
City Jammu
State Jammu and Kashmir
Key Dates
Publish Date 01 Oct 2026
Submission Date 22 Oct 2026
Open Date 24 Oct 2026
Finance
Tender Value 49 Lakhs
Tender Fee 500
EMD 98000
Exemption Available
Document List
44b5af8c-6b80-45b4-95be-6f9e28dd57fc.html
BOQ_888182.xls
TENDER38.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Oct 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

44b5af8c-6b80-45b4-95be-6f9e28dd57fc.html

xls

BOQ_888182.xls

pdf

TENDER38.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders