Tender For Repair, Erection, Assembly And Fixing Of Pontoon Bridge, Including All Allied Arrangements, Construction Of Approaches, Stay Anchors And Electrification Works, Including Transportation Of Pontoons (Iron Capsules) And Their Assembly From Te
Tender Overview
Project Description
Tender for Repair, Erection, Assembly And Fixing Of Pontoon Bridge, Including All Allied Arrangements, Construction Of Approaches, Stay Anchors And Electrification Works, Including Transportation Of Pontoons (Iron Capsules) And Their Assembly From Tendukheda Rest House C Us To Chitrakoot, Up To The Mandakini River Bank, Under Sub-Division Majhgawan. Sor Of Road 11.04.2025, Building & Electric Works Sor 01.01.2024, Non Sor Item.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in Soil using Hydraulic Excavator and Tippers with disposal up to 1000 meters.Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting suitable earth to the embankment location and disposing off unsuitable earth with all lifts and lead up to 1000m as per relevantclauses of section-300 of specification |
| 2 | Excavation in Ordinary Rock using Hydraulic Excavator and Tippers with disposal up to 1000 meters. Excavation for roadway in ordinary rock with hydraulic excavator including cutting and loading in tippers, transporting to embankment site with in all lifts and lead up to 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections as per relevant clauses of section-300 of specification. |
| 3 | Excavation in Hard Rock with disposal up to 1000 meters Excavation for roadway in hard rock with rock breakers i/c breaking rock or by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross sections, loading and disposal of cut road with all lifts and leads up to 1000 meters and as per relevant clauses of section-300 of specification. |
| 4 | Excavation in Hard rock (Blasting prohibited) |
| 5 | Embankment Construction with Material Obtained from Borrow Pits Construction of embankment with approved material having CBR>7 obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-1, 300-2 and as per relevent clauses of section-300. |
| 6 | Provdiing and laying Plain/Reinforced cement concrete in open foundation including form work shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1700 & 2100 with .RCC Grade M20 |
| 7 | Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications and as per relevant clauses of section 1600. |
| 8 | Welding by gas or electric plant including transportation ofplant at site etc. complete. |
| 9 | Structural steel work using M.S. flats, angles, channels I-section, H-section etc. riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer allcomplete. |
| 10 | Direction and Place Identification signs more than 0.9 sqm size board. Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2022 made of highintensity Micro-Prismatic Grade Sheeting (Type IV) vide IRC: 67:2022 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thickskins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2022 and Table 800-1 of MoRT&H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2022 an Table 800-3 of MoRT&H specification of in the clause 6.8 of theIRC 67-2022 and clause 801.3.7 of MoRT&H message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on 2 nos. of MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back-support frame of 25mmx25mmx3mm angle. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture brand like 3M/Avery Dennison/ Orafol Make as per clause 6.9 ofIRC: 67:2022 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2022 for the product offered shall be submitted by the contractor.Note: - Manufacture name and date of manufacture is to be printed (Embossed) at the backside of the board. |
| 11 | Construction of Murrom Road with Dust topping Construction of Murrom Road including clearing and Grubbing, cutting, trimming, loading of earth material existing ground with hydraulic excavator for avg. depth up to 0.3 m and filling, levelling of ground with approved material from borrow pit having CBR > 7 includes all lifts and leads for avg depth of 0.3 m. Construction of road also comprises of layers of Crusher Run Macadam/Dust topping of thickness 100 mm, The operation includes of Mixing, spreading, Laying in uniform layers through motor grader and watering at OMC, compaction with vibratory roller to achieve the desired density as per clause 407 of MORT&H respectively.(For minimum length of 100 m) |
| 12 | Hire Charges of Mechanical Machineries i/c Fuel & driver on Hourly basis (Minimum 4 hours in day)(i) Hydraulic Excavator (JCB Or Similar) |
| 13 | (ii) Tractor with Dozar/grader attachment |
| 14 | (iii) Soil Compactor /tandem wheel vibratory roller |
| 15 | (iv) Static Roller 8 tonne |
| 16 | Fixing of Steel Drop gate /Barrier i/c excavation of pits for stand and stopper post, fixing of posts on pit & filling balancing bin with sufficient weight as directed by Engineer in-charge. (i/c all material T&P and removal staking of same refilling of pits etc.) |
| 17 | Uniform preparation of surface by manual spreading of crushed stone/crusher stone dust/moorum/copara or similar material, 20mm to required thickness i/c manual levelling & dressing at site etc complete |
| 18 | Chequered Plate Size 5 X 1 X 0006 |
| 19 | Providing and fixing of sal wooden anchor size 1.80X1.80X3.10 |
| 20 | Suply of high intensity retro refelective (3M) |
| 21 | Suply of PP Rope |
| 22 | Supply of Sand Fill Bag |
| 23 | Transportation of iron capsule size 7.60 x 1.35 m from Rest House campus Tendukheda to baba ghat mandakini river near pramod van chitrakoot.with average lead of 350.00 km including loading & unloading . From Rest House campus Tendukheda Distt- Narsinghpur to baba ghat mandakini river near pramod van chitrakoot Distt- Satna |
| 24 | Transportation of iron capsule size 7.60 x 1.35 m from Rest House campus Tendukheda to Repair of 25 Nos Pantoon Size 7.60 X 1.35 m including providing & fixing caps with inter locking. At rest house campus Tedukhera Distt- Narsinghpur |
| 25 | MS RS Joist 3000 mm X150 mm X75 mm |
| 26 | MS Angle Railing post U Type |
| 27 | MS Angle Iron Pontoon Frame (Hauda) 1.90 M X 1.28 M |
| 28 | Providing and fixing Iron Anchor 32 MM Dia Each |
| 29 | Repair of MS Iron Railing Pipe 40 mm dia |
| 30 | Repair of MS Flate Strip 50 MM X 5.00 mm |
| 31 | Providing and fixing Washer of nut bolt 14 MM Dia |
| 32 | Providing and fixing Supply of MS Nut Bolt 75X12 mm Dia |
| 33 | Providing and fixing is positon for pantoon Size 7.60 m X 1.40 mt across baba ghat mandakni River Near Pramod Van, 422 Nos Sal Wood sleeper of Size 3.00 mX 0.20 mX X 0.15 m with welded steel frames of suitable size with all necessary nuts & screw etc. camplete. |
| 34 | Wire Rope 20 MM |
| 35 | MS U bolt 20 MM |
| 36 | 25 MM |
| 37 | 50 mm |
| 38 | MS U type Channel 95 mm X12 mm |
| 39 | MS Nails |
| 40 | Assembling of Pantoon Bridge 78 m length 2.50 m width across baba ghat mandakini river near pramod van chitrakoot. By the material supplied by the Department at Bridge site. (Up & down) Note- Rate Barman Mela 2018 @1318.00 36.00 KM but pantoon will be shifing from Rest House campus Tendukheda to baba ghat mandakini river near pramod van chitrakoot @ 1318 + 25% = 329.50 |
| 41 | Dismentling of Pantoon Bridge 78 m length 2.50 m width across baba ghat mandakini river near pramod van chitrakoot. By the material supplied by the Department at Bridge site. |
| 42 | Maintenance of Pontoon Bridge including labour nut bolt Etc & dewating from november to june 9 month |
| 43 | Octagonal poleProviding and erection of hot dipped galvanized octagonal poles in single section made from 3mm thick sheet having lockable weather proof flush door junction box, suitable size & type of foundation bolts 4 nos. 'J' type (EN8 grade) complete, erected in anapproved manner on provided foundation. 10 meter height, 175 X 70mm A/F, 275x275x16mm base plate having weight 105 kg ± 3%, 4 nos. X 24 x750mm bolt having weight 12 kg ± 3%. |
| 44 | Foundation for octagonal poleDesigning and construction of footing foundation for octagonal pole of desired size including excavation in soil/soft rock, base concrete M-7.5 (1:4:8), 15mm thick and pedestal of RCC M-20 (1:1.5:3), required tar steel reinforcement for required size from base concrete, shuttering, curing etc. with existing foundation bolts complete as per specifications in an approved manner as per manufacturer drawing or engineer-in-charge. |
| 45 | Ring carriage diaProviding and fixing of ring carriage dia. not less than 750mm made of 50mm dia. GI pipe Light 'A' class for 70mm A/F top octagonal pole with required clamps, nut, bolt etc as required. |
| 46 | LED flood lightSupplying and fixing flood light with high power LED of 3 to 6 Watt each assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning lifewith minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF > 0.95 &surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wiretesting etc. to complete the job.300Watt, color temp 3000-6500k as required. |
| 47 | G.I. earth coil of 4mm diaSupply, laying and fixing of G.I. earth coil of 4mm dia G.I. wire having 120 turns of nearly 50mm dia. and 3 mt. long tail in existing pit duly earthed with pole etc complete as required as per specification. |
| 48 | XLPE insulated power cable, al. conductorSupply of XLPE insulated power cable(conforming IS-7098 Part-I) 1100 Voltgrade, 1 core/2 core/3½ core/4 core ISImarked with alu. stranded /solid conductor4 core armoured10 sq. mm. |
| 49 | Double wall corrugated pipes (DWC) of HDPESupplying and installing double wallcorrugated pipes (DWC) of HDPE (IS14930 Part II -marked) for cable laidunderground with necessary material andat required depth upto 90cm. below road/ ground surface, excluding excavation, back filling with excavated material, ramming and making the surface good.63.00mm outside dia. |
| 50 | Cable layingLaying, 1:1 KV grade of size not exceeding 25 sq. mm in the existing itemLaying of one number armoured /unarmoured power cable 1:1 KV grade ofsize not exceeding 25 sq. mm in theexisting RCC hume/stone ware/G.I. pipe/DWC Pipe/ surface in existing trench asrequired. |
| 51 | Bakelite sheet MCBSP & stud type 4 way epoxy connector for decorative/octagonal pole box Providing and fixing of bakelite sheet 10mm thick, one MCB 6Amp-32Amp SP & 16sq.mm stud type 4 way epoxy connector for decorative designer poles /octagonal pole box. |
| 52 | MCB 'C' Series, 240/415V, 50 Cycle, 10kA/15kASupply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 :1996, IEC : 60898 :2002 & 60947-2 but without enclosures :-Single poleMCB SP 6A to 32A, 10kAMCB SP 6Amp to 32Amp 10kA rating |
| 53 | Multi core flexible cablesSupply and fixing of multi core round FRLSH PVC insulated copper (flexible) conductor & PVC sheathed cables 1100Volts as per IS:694-1990 of approved makeThree core 1.5 sq.mm.(30/0.25 mm) Three core 1.5 sq.mm. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender