Tender For Annual Repairs And Maintenance Of Electrical And Mechanical Services At Fsd Narela, Fsd Ghevra, Fsd Shakti Nagar, Do Shakti Nagar And Rajendra Place Building (Old Regional Office, Delhi) Along With Requisite Electrical Material (For Year 2
Tender Overview
Project Description
Tender for Annual Repairs And Maintenance Of Electrical And Mechanical Services At Fsd Narela, Fsd Ghevra, Fsd Shakti Nagar, Do Shakti Nagar And Rajendra Place Building (Old Regional Office, Delhi) Along With Requisite Electrical Material (For Year 2026-27)
BOQ
| Sl. No. | Item Description |
| 1 | Repairs and maintenance of following electrical and mechanical installations, details as follows and according to terms and conditions mentioned as per I.E. rules with specified attendance of wiremen and helpers/khallsis. a) E.i., Lights/Fans/Plug Points/Power Points and Street/Compound lightning/ High Mast Lighting arrangements as per I.E. Rules.b) Water Supply arrangementc) Water Coolers d) Air Coolers e) Air conditioner f) Feeder pillars/LT panels g) Any other electrical maintenance work alloted by site engineer by engagement of Wiremen and Helper(s) at Depots under DO Shakti Nagar and Rajendra Place building (Old Regional Office, Delhi) . The contractor must arrange for all types of ladders and safety gears and tools at sites keeping in mind the working height for work is 5-8 meters in suspension /wall or pole. (Minimum Wages as per Govt rules must be paid to the staff ) (T & P shall be borne by the contractor) |
| 2 | FSD Shakti Nagar - 17326 MT Capacity and Rajendra Place building (Old Regional Office, Delhi) 1 Electrician for minimum 4 days per week and whensoever required |
| 3 | FSD Shakti Nagar - 17326 MT Capacity and Rajendra Place building (Old Regional Office, Delhi) 1 Helper for minimum 4 days per week and whensoever required |
| 4 | FSD Narela - 63000 MT Capacity 1 Electrician for all working days |
| 5 | FSD Narela - 63000 MT Capacity 1 Helper for all working days |
| 6 | FSD Ghevra- 141426 MT Capacity 1 Electrician for all working days |
| 7 | FSD Ghevra- 141426 MT Capacity 1 Helper for all working days |
| 8 | Sub Head - 2 (Derived on DDSR 2022 Rates) Materials only, for installation, no labour charges is to be involve, as the same has to be get replaced by staff supplied |
| 9 | Supply of 1.5 sq.mm FRLSH PVC Insulated copper conductor single core cable |
| 10 | Supply of 2.5 sq.mm FRLSH PVC Insulated copper conductor single core cable |
| 11 | Supply of 4.0 sq.mm FRLSH PVC Insulated copper conductor single core cable |
| 12 | Supply of 6 amp to 32 amp capacity \\"c\\" curve Single Pole MCB ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge) |
| 13 | Supply of 6 amp to 32 amp capacity \\"c\\" curve Double Pole MCB ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge) |
| 14 | Supply of 6 amp to 32 amp capacity \\"c\\" curve Three Pole + Neutral MCB ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge) |
| 15 | Supply of 40 amp, 30mA, capacity Double Pole RCCB ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge) |
| 16 | Supply of 63 amp, 30mA, capacity Four Pole RCCB ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge) |
| 17 | Supply of 5/6 A Piano type switch , ISI Marked for the existing switch box/ cover including connections etc. as required (with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge) |
| 18 | Supply of 15/16 A Piano type switch , ISI Marked for the existing switch box/ cover including connections etc. as required (with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge) |
| 19 | Supply of 5/6 A Piano type socket , ISI Marked for the existing switch box/ cover including connections etc. as required (with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge) |
| 20 | Supply of 15/16 A Piano type socket , ISI Marked for the existing switch box/ cover including connections etc. as required (with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge) |
| 21 | Supply of 5/6 A Modular type switch , ISI Marked for the existing switch box/ cover including connections etc. as required (with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge) |
| 22 | Supply of 15/16 A Modular type switch , ISI Marked for the existing switch box/ cover including connections etc. as required (with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge) |
| 23 | Supply of 5/6 A Modular type socket , ISI Marked for the existing switch box/ cover including connections etc. as required (with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge) |
| 24 | Supply of 15/16 A Modular type socket , ISI Marked for the existing switch box/ cover including connections etc. as required (with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge) |
| 25 | Providing 100 A,30 kA, 4P MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holesin cubicle panel, making connections, etc. as required. |
| 26 | Providing 200 A,36 kA, 4P MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holesin cubicle panel, making connections, etc. as required. |
| 27 | 100 watt LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & ectrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). with Minimum 5 year OEM warranty. System lumen efficacy >110 m/Watt - 100 Watt |
| 28 | Supplying, installation, Testing & Commissioning of Panel light 36 watt, 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 29 | Supply of 2 * 10 sq mm Aluminium stranded conductor, XLPE Insulated, cores laid up, PVC tape/Extruded Inner sheathed for Multicore Cables , Armour (galvanised steel strip), extruded PVC Type ST2 sheathed, 1100V grade as per IS 7098(Part 1) 1988 with up to date amendments for following sizes ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge). (Refer Clause 10 A for testing and quality of material) |
| 30 | Supply of 4 * 16 sq mm Aluminium stranded conductor, XLPE Insulated, cores laid up, PVC tape/Extruded Inner sheathed for Multicore Cables , Armour (galvanised steel strip), extruded PVC Type ST2 sheathed, 1100V grade as per IS 7098(Part 1) 1988 with up to date amendments for following sizes ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge). (Refer Clause 10 A for testing and quality of material) |
| 31 | Supply, Installation, Testing and Commissioning of 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 32 | Sub Head III - Repairs of Water PumpRepairs and maintenance existing submersible tube well water pump including lifting from the existing bore well & re-installation/ re-fixing details are given as given below (up to 2 HP capacity) |
| 33 | Lifting & lowering the existing Single phase submersible water pump along with pipe line from bore well including G.I. /PVC Pipe Line, Valves etc. as required. &Service & rewinding of submersible / mono-block / mono submersible water pump with copper wire and replacement of required accessories i.e. bearing, bush, etc. in submersible motor pump set. including credit the damage wire. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender