Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #57819528

Tender For Addn/Altn To Toilet Blocks (04 Nos) Of Primary Wing Of Pm Shri Kendriya Vidyalay annual maintenance contract cement concrete Under Ge (East) Lucknow

Issued by Statutory Bodies & Commissions/Committees · Lucknow, Uttar Pradesh
Tender Value
23.88 Lakhs
Estimated cost
Bid Submission
22 Oct 2026
19 days left
EMD
47760
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Addn/Altn To Toilet Blocks (04 Nos) Of Primary Wing Of Pm Shri Kendriya Vidyalay annual maintenance contract cement concrete Under Ge (East) Lucknow

BOQ

Name of Work:- ADDN/ALTN TO TOILET BLOCKS (04 NOS) OF PRIMARY WING OF PM SHRI KENDRIYA VIDYALAY AMC CC UNDER GE (EAST) LUCKNOW
Sl. No. Item Description
1Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 cm thickness below and above ground level, complete all as specified and directed.
2Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches , pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles.
3M & L for brick work using old size fly ash brick, straight or curved on plan exc 6m mean radius, built in CM (1:6), complete all as specified and directed.
4M&L PCC 1:2:4, type B1 using 20 mm graded stone aggregate as in roof kerbs / benching / coving and roof padding over roof surfaces /sunken treatment etc rounded or chamfered on edges, complete all as specified and directed.
5M&L for Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:4 mixed with water proofing compound (ISI marked) @ 200 ml per bag cement by weight of cement or as per manufacturer’s instructions, w/o using extra cement complete all as specified.Note :- Supply only water proofing compound shall be measured and paid for separately.
6M&L for providing and applying single component PU Magnum solvent base Pure polyurethane liquid membrane for the concrete roof surfaces in two coats @1.85kg/ sqm and mixing ratio of hardener and base is 95:05 and consisting of a coat of two component epoxy primer in ratio of 1:1 (one part of resin and one parts of hardner) at a consumption of 0.200kg/sqm The vital physical and chemical parameters shall be as under : Min Elongation at break of 500% as per ASTM D2370 and tensile strength of 3.0 N/mm2 as per ASTM D2370, Crack Bridging ability greater than 3mm as per C1305 ,Water Impermeability on coated concrete @7 bar as per DIN1048,Water vapor permeability 0.72 perms as EN ISO 7783-2 . The material shall be applied with brush and it should be tested according to EN 1504-2 as a coating for surface protection for concrete complete in all respect as per the direction of Engineer-in-charge.
7Demolition of sunken slab floor of WC and Bath including WC trap etc upto 50cm depth incl taking down loose filling of aggregate in any type and removing where direted and providing water proofing treatment of sunken slab as follows:-(a) 15mm thick rendering on vertical sides of RCC slab in CM 1:3 mixed with chemical \\" PIDIPROFF LW of Dr Pidilite or equivalent \\" as per manufacturer instructions. (b) Cleaning the concrete surface by brushing and watering and remove all surface inperfections. (c) Fixing 40mm dia Pipe 450mm long at bottom of the sunken floor and wraping of bath seal tape on the pipes inserted through walls to floor area and seal it (Bath seal tape product of Dr fixit or equivalent and grouting around the inserted pipes by pouring Dr fixit bath seal or equivalent grout as directed(d) Make angle fillets by mixing sand cement and Dr fixit pidicrete URP or equivalenont all corners.(e) Brushing neat cement slurry two coats with high performance cementitious polymer water proofing coating of Dr fixit bath seal WPC or equivalent of thickness 1mm in combination of WPC and cement (1:1.5) by vol and giving upto height 15cm from bottom slab and allow it dry completely. (f) Providing PCC 1:4:8 type D-2 using 40mm graded stone aggregate, 150 mm thick mixed with WPC as per mnufacturer instructions in sunken slab after filling brick bats to match floor level .(g) Fill the sanitary gaps with sealing compounds complete.
8Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc, complete all as specified and directed.
9M&L for rendering/plaster by using readymix mixture of thickness 12 mm to 15 mm on newly prepared surface and plastering the wall surface with white cement based polymer modified self curing mortar, all complete as per the direction of Engineer-in-Charge.
10Repair to plaster by using readymix mixture of thickness 12 mm to 15 mm and taking down cement or cement lime plaster, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-in-Charge.
11Repair to plaster by using readymix mixture of thickness 5 mm to 7 mm in ceiling including taking down cement or cement lime plaster, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-in-Charge.
12Complete removal of existing treatment from wall applying two coats of oil bond distemper over a coat of primer over a coat of wall care putty (2 mm thick) to make surface even and smooth, and complete all as specified and directed.
13M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bond distemper over a coat of primer over a coat of wall care putty (2 mm thick) to make surface even and smooth, and complete all as specified and directed.
14M & L for complete removal of exisiting finish/newly plastered surface (with mechanical sander machine) on walls and applying plaster of paris putty of min 1 mm thickness to prepare the surface even and smooth and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as speciifed. Note:- Paint to be applied with airless spray machine.
15M&L for preparation of newly plastered surfaces of ceilings and applying two coats of oil bond distemper over a coat of primer over a coat of wall care putty (2 mm thick) to make surface even and smooth, and complete all as specified and directed.
16Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed.
17Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed.
18M & L coloured Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) are of each tile exc 0.11 Sqm but n. Exc. 0.18 Sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layer with CM 1:6 complete all as specified and directed.
19M&L glazed ceramic coloured tiles in vertical surfaces 450x300x7mm/600x300x7mm thick, set and joiunted in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
20M&L for full body, joint free granalt tiles15mm thick,designed to mimic the luxurious look of natural granite and marble (Red flex or any dark shade as approved byGE with superior practicality, of size 800x2400mm Mat and glossy finishes for floors, walls, and counter tops, all while being easy to maintain, stain-resistant, white cement (1:2) usingmar bledust with admixture of pigment to match with shade of granite including roundingof edge laid over 15mm thick screed bed in CM(1:4) including rounding of edge of stone slabs one edge complete all as specified and directed.
21M&L for 75 mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate complete all as specified
22M&L for cutting chases, pinning in, making good to facings as original where required and pointing in cement mortar 1:3 for concealed water tubing etc. and making good, cutting not exc 10 cm girth in brick walls.
23Taking up or down 15mm dia steel tubing and connections,including cleaning for refixing or removal to store complete all as specified and as directed.
24Taking up or down 20mm dia steel tubing and connections,including cleaning for refixing or removal to store complete all as specified and as directed.
25S&F 16mm CPVC of Outer dia pipes SDR 11 & Plain CPVC SDR 11 with all fittings tee, elbow & bends on walls/ceiling or laying in grade with all fitting and fixed complete to walls and ceiling or laid in floor all as specified and directed.
26S&F 20 mm CPVC of Outer dia pipes SDR 11 & Plain CPVC SDR 11 with all fittings tee, elbow & bends on walls/ceiling or laying in grade with all fitting and fixed complete to walls and ceiling or laid in floor all as specified and directed.
27S&F CPVC 16mm Brass Elbow to connect 16 mm CPVC of outer dia pipes including solvent,on walls/ceiling or laying in grade with all fitting and fixed complete to walls and ceiling or laid in floor all as specified and directed.
28S&F CPVC 20mm Brass Elbow to connect 16 mm CPVC of outer dia pipes including solvent,on walls/ceiling or laying in grade with all fitting and fixed complete to walls and ceiling or laid in floor all as specified and directed.
29S&F CPVC 16mm Brass Tee to connect 16 mm CPVC of outer dia pipes including solvent,on walls/ceiling or laying in grade with all fitting and fixed complete to walls and ceiling or laid in floor all as specified and directed.
30S&F CPVC 20 mm Brass Tee to connect 16 mm CPVC of outer dia pipes including solvent,on walls/ceiling or laying in grade with all fitting and fixed complete to walls and ceiling or laid in floor all as specified and directed.
31S&F in repair to any existing EWC/WC into a one piece EWC with soft close seat cover complete all as specificed & directed.
32S & F in repair vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests, trap sets and neceassary fitting and fixtures and fixing with Cement concrete bedding (excluding flushing cistern and flush pipe) and making good the disturbed portion with tiles matching adjacent area complete all as specified and as directed.
33S&F in repairs PVC valveless syphonic action type low level flushing cistern (ISI marked) of 10 litre capacity including 32 mm dia PVC flush pipe connected to water closet with inlet, ball valve, float and handle complete all as specified.
34S&F PVC connection 450 mm long suitable for 15 mm bore GI pipe including CP brass nuts on both sides, complete all as specified & directed.
35S&F PVC connection 600 mm long suitable for 15 mm bore GI pipe including CP brass nuts on both sides, complete all as specified & directed.
36S&F in repairs long body 15mm bore bib tap, fancy type, chromium plated, cast copper alloy, with capstan head, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified & directed.
37S&F in repairs CP angle valve, fancy type long body for 15 mm bore pipe with capstan head long screwed shank including cp cover plate complete all as specified & directed.
38S&F in repairs bevelled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial Ply wood backing fixed to wooden plugs with chromium plated brass screws and cup washer, complete all as specified and directed.
39S&F in repair CP brass health faucet not exc 1.25 m long flexible tube including wall hook complete all as specified and directed.
40S&F in repair toilet paper holder, brass chromium plated fixed to walls with chromium plated (CP) brass screws complete, all as specified & directed.
41S&F 1000 Litre capacity Rotational moulded polyethylene water storage tanks, triple layered (cylindrical, vertical with closed top) hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe incl 20 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete after dismantling old RCC/PVC tank, all as specified and directed.
42S&F in repairs 20 mm bore gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed, all as specified.
43S & F in repair PP (Polymer Pipes ) Drainage (Drain PRO) pipe 110 mm single socketed, in any length with shield coupling with EPDM rubber gasket, laid in trenches or in floors complete all specified and directed.
44SS & F in repair PP (Polymer Pipes ) Drainage (Drain PRO) pipe 110 mm single socketed, in any length with shield coupling with EPDM rubber gaske,including stack clamps fixed to walls complete all specified and directed.Note All pipe to be laid on prepainted MS Clamp of FI 50x5 mm on ditance of 1500 mm and pipe to be kept 75 mm away from wall .All clamp to be fixed in wall with suitable 16 mm round iron stays & shall be same MAKE as approval of PP pipes .
45S & F in repair PP (Polymer Pipes ) Drainage (Drain PRO) pipe 75 mm single socketed, in any length with shield coupling with EPDM rubber gasket, laid in trenches or in floors complete all specified and
46SS & F in repair PP (Polymer Pipes ) Drainage (Drain PRO) pipe 75 mm single socketed, in any length with shield coupling with EPDM rubber gaske,including stack clamps fixed to walls complete all specified and directed.Note All pipe to be laid on Galvanised Clamp of FI 50x5 mm on ditance of 1500 mm and pipe to be kept 75 mm away from wall .All clamp to be fixed in wall with suitable 16 mm round iron stays .
47S & F in repair PP (Polymer Pipes ) Bend (Drain PRO) with or without access door, bend, etc any radius 110mm size with shield coupling with EPDM rubber gasket complete all specified and directed
48S & F in repair PP (Polymer Pipes ) Bend (Drain PRO) with or without access bend etc any radius 75 mm size with shield coupling with EPDM rubber gasket complete all specified and directed
49S & F in repair PP (Polymer Pipes ) Tee (Drain PRO) 110 mm Tee, equal or unequal complete all specified and directed
50S & F in repair PP (Polymer Pipes ) Tee (Drain PRO) 75 mm Tee, equal or unequal complete all specified and directed
51S & F in repair PP (Polymer Pipes ) Trap (Drain PRO) 110 mm /75mm (depend on location) bore floor trap including with shield coupling with EPDM rubber gasket complete all as specified & directed.
52S & F in repair PP (Polymer Pipes ) Vent Cowl (Drain PRO) 110 mm /75mm (depend on location) dia vent cowl, complete all as specified and directed.
53S & F in repair Stack galvanised clamps made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof of 110mm dia pipe complete all as specified & directed.
54S & F in repair Stack clamps made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof of 75mm dia pipe complete all as specified & directed.
55Taking down chowkhat with shutter (without taking off shutter from the frame) and area exc 1.5 sqm but n.exc 4 sqm each, complete, all as specified & directed.
56Taking down chowkhat with shutter (without taking off shutter from the frame) and area not exc 1.5 sqm each, complete, all as specified & directed.
57S&F 150mm size stainless steel fancy type handle, complete all as specified and directed.
58S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.
59S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm thickness comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.
60S&F butt hinges of size 100 mm medium weight, stainless steel ISI marked complete all as specified.
61S&F 200 mm long stainless steel tower bolts of extruded section (ISI marked) complete all as specified
62S&F 100mm double legged door stopper of stainless steel with rubber base all as specified and directed by Engr-in-charge.
63S&F 300 mm long stainless steel sliding door bolts, fancy type, with bright bolt not less than 12mm dia and including a minimum of 06 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete, all as specified.
64S&F mild steel helical door spring 300mm ordinary rat tail rod pattern spring including roller and roller plate complete all as specified.
65S&F powder coated(min thickness of powder coating 50 micron) anodised aluminum window shutter three track sliding type, section having frame size bottom with outer 92x45.5x1.5mm (section code 20617) , top and side 92x31.75x1.5 (section code 20831) & aluminum section of shutter top and bottom size 40 x 18 x 1.5 ( section code 20736) , interlock size 40 x 18x 1.45 (section code 20737), side/ middle size 40 x18 x1.55, (section code 20738) including necessary joining cleats, glazing clips rubber backing, anodised aluminum snap beading screw, anodised aluminum fitting complete as per site requirtement glazing by using 5mm thick plain sheet glass and ss wiremess of dia 0.36mm and aperture 1.4mm thick all as specified and directed. Ref drg no celz/c-td/151 sheet no 1/1 & 2/2 .Note- 1. Glazed shutter glass thickness not less than 5mm and ss wiremess shutter with ss wiremesh as approved by GE is also included. No payment will be made separately.2. No extra payment will be made for section profiles of higher sizes.
66S&F powder coated aluminum ventilator ( louvers) shutter with 3.8 mm thick plain / tinted glass consisting of frame of size 63.5 x 44 and shutter sections weighing not less than 0.55 kg/m with locking arrangement as approved fixed including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings with stainless steel wiremesh of 0.36mm including necessary fixing arrangement complete all as specified and directed
67M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified.
68M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified.
69M & L Preparation of new steel or iron surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer all as specified
70S&F for stainless steel wire cloth, 0.36mm nominal dia of wire & average width of aperture 1.40mm & fixed with alluminium wire staples, (any welding work required will be included) complete all as specified and directed.
71Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed
72M&L for RCC 1:2:4 nominal mix type B1 (using 20 mm graded aggrigate)as in Beams, cantilevers, bressummers, lintels over 1.5m span complete, all as specified and directed.
73M&L for RCC 1:2:4 nominal mix type B1 (using 20 mm graded aggrigate)as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete, all as specified and directed.
74Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified.
75Use and waste of formwork to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exc 200mm thick, flat rough finished surface of concrete complete, all as specified and directed.
76M&L for TMT bars 10mm dia and over cut to length, bent to shape required including cranking and binding with Mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
77Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete all as specified and directed.
78Material and labour for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall etc and making good to the disturbed surfaces to match the existing complete all as specified and directed.
79All as per serial item No 79 here-in-before but one 3 pin, 06 Amp socket outlet point on independent board controlled by one, one way switch 06 Amp.
80All as per serial item No 79 here-in-before but one 3 pin, 06 Amp socket outlet point on same board controlled by one, one way switch 06 Amp.
81All as per Serial Item No 79 here-in-before but point wiring with 2.5 Sq mm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 16 Amp socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
82S&F in replacement Switch Modular 6A single pole, one way, 1 module complete all as specified and as directed
83S&F in replacement Switch Modular 16A single pole, one way, 1 module complete all as specified and as directed
84S&F in replacement Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed
85S&F in replacement Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed
86S&F in replacement Modular White cover plate with frame,8 module complete all as specified and as directed
87S&F in replacement Modular White cover plate with frame,4 module complete all as specified and as directed
88S&F in replacement Modular White cover plate with frame,3 module complete all as specified and as directed
89S&F in replacement Modular Metal flush box 8 module complete all as specified and as directed
90S&F in replacement Modular Metal flush box 4 module complete all as specified and as directed
91S&F in replacement Modular Metal flush box 3 module complete all as specified and as directed
92Supply and fix in replacement of integrated LED bulk head fitting 10 Watt, 6500K with IP 65 protection comprises of high pressure die cast aluminium housing, polycarbonate cover, etc complete all as specified and directed.
93Supply and fix in replacement LED tube light fittings 1200 mm,20 W higher energy saving decorative ultra slim square profile LED lighting fixture with extruded aluminum housing enviromental friendly, energy efficient complete all as specified and directed.
94Supply and fix in replacement rectangle wall light LED integrated fittings MS wit polycarbonate diffuser Chrome colour dimension size 300x65x130 mm, 1000 lmn ,10 watt wall mounted higher energy saving decorative ultra enviromental friendly, energy efficient complete all as specified and directed.
95Supply and fix in replacement ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm size complete all as specified & directed.
96Material and labour in replacement for sub main wiring with 6 Sq mm nominal cross sectional area,2 run single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 6 Sq mm nominal cross sectional area, single core r runs ( neutral and earth colour code wire), 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.Note : 2 runs of 06 sqmm, 1 run of 6 sqmm earth and nutral conductor and 1 run of PVC conduit shall be measured as one unit length for
97Material and labour in replacement for sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.Note : 2 runs of 4 sqmm, 1 run of 4 sqmm earth and nutral conductor and 1 run of PVC conduit shall be measured as one unit length for
98Supply and fix AC modular Box 20 Amp with steel enclosure suitable for Geyser & AC protection to human from eletric shock due to direct and Indirect current as well as provide protection from overload and short circuit fault complete with MCB 20Amp after fixing making good surface with fine plastering, finishing and colouring with existing colour matching complete all as specified
99Supply and fix in replacement of sheet metal enclosure distribution board, double door, single pole and neutral, AC, 240 volt, 08 way, with 100 Amp rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
100Supply and fix in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN),double door, AC, 440 volt, 04 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed and comprising of the following:- (a) MCCB, 125 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No.(b) MCB, SP, AC, 240 volt of 06 to 32 Amp, \\"C\\" curve, 10 KA breaking capacity - 12 Nos.
101Supply and fix in replacement of MCB, SP, AC, 240 volt of 06 to 40 Amp capacity \\"C\\" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
102Supply and fix in replacement of MCB, SPN, AC, 240 volt of 63 Amp capacity \\"C\\" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
103Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed.
104Supply and fixing of stationery storage type electric BEE 5 star rated Hot Water Geyser of capacity 25 Ltr to operate on 230 volt AC, vertical type, working pressure min 0.8 Mpa with ,multi function safety valve and PUF insulation including 4 nos full threaded fastner of size 100 x 10 mm with 2 Nos washer, water connection complete all as specified and directed.
105S&F exhaust fans, plastic body, ac, single phase, 230/240 v of size 300 mm sweep with louver and making connection with twisted copper flexible wire 23/0.076mm all as specified and directed
106Supply and fixing in replacement LED Bldg security light fitting LED 35 watt with SPD, PF not less or equal 0.9,epoxy coated cover sheet aluminium housing with heat resistant toughtened glass & IP 66 incl with bracket, clamps, nuts, bolts protection complete all as specified and directed and directed.
107Cutting walls any type, making holes for fixing of exhaust fan of any size or sweep and making good surface with fine plastering, finishing and colouring with existing colour matching complete all as specified and directed
108Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm 3.5core complete all as specified and directed.
109Excavation in trenches soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of pipes/cables etc getting out and bottom surface to required gradient complete all as directed & specified
110M & L Returning filling in including spreading leveling watering and well ramming in layers each not exceeding 25 cm thickness complete all as specified and as directed
111M & L Removal of surplus spoil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed
112Supplying, filling in trenches, spreading, leveling sand cushioning 8 cm below cable and 15 cm above the cable for under ground cable complete all as specified & directed. i.e 18 cm punned down thick shall be considerd for mesurement)
113M & L Old size sub class 'B' bricks,laid flat in trenches over the cable with length of brick perpendicular to the direction of the cable , adjacent/abutting each other complete all as specified
114Supply and fix GI pipe 80 MM medium grade in wall incl cutting complete and making good surface all as specified Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57819528
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 23.88 Lakhs
LAST DATE 22-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Addn/Altn To Toilet Blocks (04 Nos) Of Primary Wing Of Pm Shri Kendriya Vidyalay annual maintenance contract cement concrete Under Ge (East) Lucknow
Basic Detail
Tender No GE/E/LKO/T-100 OF 2026-27
Bidding Type Tender
Location
City Lucknow
State Uttar Pradesh
Key Dates
Publish Date 01 Oct 2026
Submission Date 22 Oct 2026
Open Date 26 Oct 2026
Finance
Tender Value 23.88 Lakhs
Tender Fee 500
EMD 47760
Exemption Available
Document List
5c440cb8-f757-42b4-ac6b-ef3d30d11630.html
BOQ_888092.xls
Tendernotice_1.pdf
TenderT100.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Oct 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.