Road Transport and Highways Government Departments Closing in 6 days TDR #57819499

Tender For Permannent Rectification Of Blackspots Including Street Lights On Nh 52/11.

Issued by Government Departments · Sikar, Rajasthan
Tender Value
5.16 Crore
Estimated cost
Bid Submission
18 Nov 2026
6 days left
EMD
10.33 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sikar → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Permannent Rectification Of Blackspots Including Street Lights On Nh 52/11.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 16-Oct-2026 CORRIGENDUM Technical Bid 04-Nov-2026
2 22-Oct-2026 CORRIGENDUM Date 04-Nov-2026
3 16-Oct-2026 CORRIGENDUM Technical Bid 23-Oct-2026
4 16-Oct-2026 CORRIGENDUM Technical Bid 18-Nov-2026

BOQ

Name of Work:- Permannent rectification of blackspots including street lights on NH 52/11.
Sl. No. Item Description
1Street Lighting System for Both Side
2Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR.
3Chandpura(Ch.6.300-6.500),Dhod(Ch.08.900-09.300),Prince(Ch.10.800-11.00),laxmangarh four line (372.200-374.700),laxmangarh VUP(Ch.374.700-375.600),Chhichhas Bus Stand(ch.380.900-381.400)Harsawa(Ch.386.500-387.500),Ratangarh ROB(Ch.431.600-432.600),Payali(Ch.436.500-437.00),Sridungargarh(Ch.490.900-494.900,gussaisar(Ch.530.500-531.500),Expressway(Ch.538.00-538.500),norangdesar(Ch.540.200-540.700),Bikaner city(553.900-557.775),
4Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as par pre approved by Engineer in charge.
5Single arm overhang
6Double arm overhang
7Providing & Fixing of mechanical /digital time switch having following day / week programe and minimun 100 hours reseve and AC1 rating of 16-20 amperes induding making connection, progrvrrnlng conforming to IEC 60730-1 and 60730-2-7 etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work refer Annexure \\"A\\" attached with this BSR .
8One day & week reserve (digital type )
9Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 2.5 Sq. mm 3 core
10Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .A) Excavation of Pit for Foundation Size upto required depth from Ground levelB) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete.C) Providing and laying in position cement concrete of M-10 grade of 75 mm thicknessD) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete.E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and PedestalF) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations.G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days.H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face.
11Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr.
12Providing & Laying P.V.C. / XLPE Insulated & P.V.C. sheathed Arrmoured Aluminium cable confinnlng to IS:155-4 P-I / IS :7098 P- I of 1. 1 KV with H-4 Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 % round / flate strip Armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / cable tray(wilh cable tie) Including testing etc. as required of following size. OEM must having its own In house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product /work refer Annexure \\"A\\" attached with this BSR
1350.0 Sq. mm 3.5 core
1416.0 Sq. mm 4' core
15Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 40A rating
16Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) 70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/ accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
17LED Street Light fixture with Minimum lumen output 25000 lm,225 W
18High Mast Lighting System
19Supply installation testing & Commissioning of high mast lighting system (as per PLG 07 of ILP UK–techinical report no 7 of ILE UK /IS:875 Part-1 2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by piecewise single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement (winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, Stainless steel 6 mm dia. wire ropes (AISI 316, 7 / 19 costruction 3 no. rope for lantern carrage & 2 no. rope for winch assembly ) foundation bolt, torque limiter,EPR insulated PCP sheathed 5 core x 2.5 Sq.mm trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135.etc. as required on Existing Foundation. ( See table P - 03 for specs.) OEM Must have Type test certificate for wind tunnel test . All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
2030.0 Mtr Hm (in 2 section) suitable for 12 No. Luminaries
21Sanwali Ch.4.850,Nani Circle Ch.14.400,Badhadhar tiraha Ch.356.900,badhadhar Ch.357.00,Ghassu Ch.369.00,Bagari Choraha Ch.375.700,sach canteen Ch.403.400,Loonch fanta ch.429.00,Sangam Choraha Ch.433.300,om banna temple Ch. 436.700,Prsneu fanta Ch. 456.200 ,Momasar fanta Ch.460.00,Bighaji Ch.480.00,nakht banna Ch.512.00,Janjheu Ch.516.900,Raysar Ch. 547.00 ,Jaipur Circle Ch.553.900,napasar Ch.04.400,choraha Ch.15.800,End point Ch.17.240
22Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .A) Excavation of Pit for Foundation Size upto required depth from Ground levelB) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete.C) Providing and laying in position cement concrete of M-10 grade of 75 mm thicknessD) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete.E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and PedestalF) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations.G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days.H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face.
23Pole Foundation for Octagonal pole from 10 Mtr. To 12 Mtr.
24Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
25High Power LED Flood Light Minimum lumen output 43750 lm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57819499
AUTHORITY Government Departments
TENDER VALUE 5.16 Crore
LAST DATE 18-11-2026
Authority
Authority Name Ministry Of Road Transport And Highways
Work Description Tender for Permannent Rectification Of Blackspots Including Street Lights On Nh 52/11.
Basic Detail
Tender No EE NH Churu NIT No. 03/2026-27(01)
Bidding Type Tender
Location
City Sikar
State Rajasthan
Key Dates
Publish Date 16 Oct 2026
Submission Date 18 Nov 2026
Open Date 01 Jan 0001
Finance
Tender Value 5.16 Crore
Tender Fee 10000
EMD 10.33 Lakhs
Exemption Available
Document List
4b908468-4a5d-473f-89e8-20846508be38.html
BOQ_975855.xls
NIT.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 04, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 04, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 23, 2026
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 18, 2026
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 6 days
Nov 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

4b908468-4a5d-473f-89e8-20846508be38.html

xls

BOQ_975855.xls

pdf

NIT.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender