Power Government Departments Closing in 13 days TDR #57816479

Tender For Replacement Of Various Equipments At 132 Kv Gss Sagwara ,02 X 33 Kv Feeder Bay At 132 Kv Gss Sagwara & 01 No. 132 Kv Feeder Bay At 220 Kv Gss Sagwara.

Issued by Government Departments · Dungarpur, Rajasthan
Tender Value
5.31 Lakhs
Estimated cost
Bid Submission
15 Oct 2026
13 days left
EMD
10650
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dungarpur → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Replacement Of Various Equipments At 132 Kv Gss Sagwara ,02 X 33 Kv Feeder Bay At 132 Kv Gss Sagwara & 01 No. 132 Kv Feeder Bay At 220 Kv Gss Sagwara.

BOQ

Name of Work:- REPLACEMENT OF VARIOUS EQUIPMENTS AT 132 KV GSS SAGWARA ,02 X 33 KV FEEDER BAY AT 132 KV GSS SAGWARA & 01 No. 132 KV Feeder Bay at 220 KV GSS SAGWARA.
Sl. No. Item Description
1Laying of earth mesh with 25mm I 28mm dia. M.S. Rod at a depth of 0.80 metre from top level of foundations, including excavation of trench of required depth and backfilling of the same, transportation of M. S. Rods from site store to locations, welding of M. S. Rod to M. S. Rod along the length, at crossings and with earth electrodes as per drawing, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, for the type of soil prevalent at 0.80 metre below top level of foundations (M. S. Rod of above sizes & M. S. Flat as required shall be made available by RVPN)i) any soil, softrock other then hard rock
2ii) Hard rock(with blasting subject to permissionor without blasting )
3i) any soil, softrock other then hard rock
4ii) Hard rock (with blasting subject to permission or without blasting )
5Placing/ Driving of Earth Electrode of 25/28 MM dia M.s. Rod of length 3.30 meters (approx.) to a depth of 3.80 meter from the top level of foundations, including excavation of pit as required and back filling of the same, transportation of M.S. Rod from site store to locations, cutting of M.S. Rod to desired length, prepration of one end as spike if necessary welding of earth electrode to earth mesh of M.S. Rod as per drawing, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, for the type of soil prevalent at 3.80 meters below top level of foundations (M.S.Rod of above size & M.S.Flat as required shall be made available by RVPN)Any Soil, soft rock other than hard Rock
6Hard rock (with blasting subject to permission or without blasting
7ERECTION OF STEEL STRUCTUREERECTION OF SUB-STATION STEEL STRUCTURES columns, beams, lighting mast and equipment structures (excluding Circuit Breakers and Capacitor Banks) of all types including transportation of structure members,nuts & bolts, washers, etc. from site store to locations, their assembly, placing on foundation, fixing of template, with foundation bolts as required, levelling and preparing for grouting as required, but excluding grouting, erection after grouting and tightening & punching of nuts & bolts.( Maximum height of structures up to 20 meters)
8Bus-Bar WorkSTRINGING of 220 KV, 132 KV, 33 KV & 11KV Bus Bar of ACSR & Tarantulla conductor, including transportation of conductor, disc insulators and tension hardware from site stores to location, laying and cutting required length of conductor, cleaning and assembly of disc insulators as required along with fitting of bolted type or compression type tension hardware as made available, making up at one end, stringing of conductors between the beams with specified sag and tension, also equalizing sag and fitting spacers and spacer T-clamps for twin conductor, for three phases of conductors in each bus-section.(Per jumper basisii) Any single Conductor
9ii)AnyDoubleConductor
10JUMPERS of any conductor (3 nos. Y- type) between bus to equipment, or between equipment to equipment or between bus to bus, including transportation of conductor, disc insulators and hardware from site stores to locations, cleaning and assembly of disc insulators as required along with fitting of suspension hardware and erection as required, cutting required length of conductor, making connections, fixing of spacers & spacer T-clamps as required, tightening of clamps 1connectors, dressing, etc., for three phases. (Per jumper basis)i) Any Conductor
11STRINGINGofEarthwire(size7/3.15minor7/4.00mm)includingtransportationofearthwire,tensionhardwares,etc.,fromsitestoreto locations, laying and cutting required length of earthwire, fittingof bolted type or compression type hardware as madeavailable,stringing of earthwire between structure peaks withspacified sag and tension,jumpering and connection earthbonds,for single earth wire.
12Stringing of Earthwire (7/3.15MM) including transportation of earthwire , tension, hardware etc
13ERECTION OF SUB STATION EQUIPMENTSErection of Current Transformer / Potential Transformer / Capacitive voltage Transformer 1 Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc., complete in all respects.i) 132 KV CT / PT / CVT
14(ii)33KVCT/PT
15Erection of Lightening Arrestor on already erected steel structure including transportation of Lightening Arrestor, clamps & connectors, surge counter, etc. from site store to locations, fabrication of base frame, fixing of terminal connectors, surge counter, tightening of nuts & bolts etc., complete in all respectii) 132 KV
16iii) 33 KV or 11 KV
17Erection of Isolators(Motorised/Non motorised) on already erected steel structure including transportation of base frame, P. I.'s, contacts, mechanism box, clamps & connectors, etc. from site store to locations, minor fabrication as required, and fixing of terminal connectors, etc., adjustment! alignment of isolator and its earth blade, if provided, for their smooth operation and final adjustment if required after jumpering including erection of PIa) Without Earth Blade
18b) With Earthblade
19a) Without Earth Blade
20b)WithSingleEarthBlade
21Erection of Wave trap on already erected structure beam, including transportation of wave trap, disc insulators, hardware, clamps and connectors, etc from site store to locations, cleaning & assembly of disc insulators alonwith fitting of suspension arrangement and erection, fixing of terminal connectors, etc132 KV
22Erection of 220 KV or 132 KV Circuit Breakers, including transportation of equipment, structure members, nuts & bolts, clamps & connectors, accessories etc. from site store to location, assembly of support structure, their placing on foundation, levelling and preparing for grouting as required, but excluding grouting, assembly / placing of support columns / poles, mechanism box / control cubicle, and other accessories as per manufacturer's drawings, fitting of SF 6 gas pipeline, fabrication of air / oil pipeline as required, electrical wiring from pole to control cubicle, fixing of terminal connectors as required, but excluding commissioning of CB, for all types of operating mechanism, as required.ii)132 KV
23Erection of 33 KV or 11 KV Circuit Breakers includingtransportation of equipment, structure members, nuts & bolts,clamps&connectors,etc.fromsitestoretolocation,assemblyofsupport structure, their placing on foundation, levelling andpreparing for grouting as required, but excluding grouting,assembly / placing of poles, mechanism box, etc. on supportstructure as per manufacturer’s drawings, fitting of terminalconnectors, etc. but excluding commissioning of CB. i)33KV or 11KV Outdoor Type(VCB/SF6)
24Erection of Control & Relay Panels complete in all respects including transportation from site store to control room, placing on foundation I cable trench as per layout, interconnection between Control & Relay panels and with existing panels, fixing of side I top covers and doors, earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay panel, as requiredii) Duplex Panel
25iii)Duplex Panel
26iii) Simplex Panel, DC Panel, RTCC Panel, PLCC Panel etc.
27Erection of Marshalling Kiosk! Line Matching Unit (LMU) I Line Matching & Distribution Unit (LMDU) complete in all respect including transportation from site store to location, placing on foundation I cable trench as per layout, preparing for grouting of foundation bolts but excluding grouting, etc.i) 220 KV or 132 KV Marshelling Kiosk
28ii) 33 KV or 11 KV Marshelling Kiosk
29Laying and termination of cableControl Cablesi) Laying of P. V. C. insulated unarmoured / armoured control cables of 1.1 KV grade with copper conductor in cable trenches as per specification as required, including transportation of cable drums from site store to locations, laying in cable trenches, cutting to required length, placinq them on cable racks / cable trays / cable batten & dressing, including removing and refixing trench covers as required, making necessary connections, testing, cable marking on both the terminating ends, etc., as required for all sizes from 2c x 2.5 sq. mm. to 20c x 2.5 sq. mm, 4c x 4 sq. mm. and 4c x 6 sq. mm.(a) Unarmoured control cables
30ii) Fixing of control cables in position with single compression nickel plated brass cable glands confirming to IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates, etc. as required & including cost of cable glands, for each cable gland of size.(a) 19 sq. mm unarmoured control cables
31(c) 25 sq. mm unarmoured control cables
32(e) 32 sq. mm unarmoured control cables
33iii) Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type as required of Dowell's or equivalent make as approved by the Engineer - In - Charge) duly crimped with crimping tool, including making wire ends ready for crimping, ferruling & dressing of wires, etc., as required, including cost of terminal ends for all wires, for each cableat both ends for cables of the following sizesa) 2.5 Sqmm for any number of core
34b) 4 Sqmm for any number of cor
35Dismantle Work ( Cost @ 60% of Erection Cost )Dismantle Bus-Bar WorkJUMPERS of ACSR conductor(3 nos. Y-type) between bus toequipment or between equipment to equipment bus to bus,including transportation of conductor, disc Insulators andhardwarefromsitestorestolocations,cleaningandassemblyofdisc insulators as required along with fittingof suspensionhardware and erection as required, cutting required length ofconductor, making connections, fixing of spcers T-clamps asrequired,tighting of clamps/ connectors,dressing etc.for three phases.(PerJumperBasis)i)AnyConductor
36DismantleworkofSub-StationEquipmentsErection of Current Transformer / Potential Transformer /Capacitive voltage Transformer / Series Reactor / ResidualVoltageTransformer/NeutralCurrentTransformerwithclamps& connectors, on already erected steel structure includingtransportation from site store to locations, fabrication of baseframe,fixingofterminalconnectors,tighteningofnuts&bolts etc.,completeinallrespects.(ii)132KVCT/PT/CVT
37(ii)33KVCT/PT
38Dismantle of Isolators (Motorised/Nonmotorised) on already erected steel structure including transportation of base frame.P.I.'s.contacts.Mechanism-box,clamps&connectors,etc.fromsite store to locations. Minor fabrication as required, and fixingofterminalconnectorsetc,adjustment/alignmentofisolatorandits earth blade, if provided, for their smooth operation and finaladjustment if required after jumpering including erection of PI.iii)33KV&11KVa)WithoutEarthBlade
39Dismantle of Control & Relay Panels complete in all respectsincludingtransportationtositestoretocontrolroom,palcingonfoundation/cabletrenchasperlayout,interconnectionbetweenControl &Relaypanels and with existingpanels and with withexistingpanels,fixingofside/top coversand doorsearthlingtoexistingEarthstripincontrolroom,connectionofbuswiringtoexistingpanelandbetweencontrolandrelaypanelsasrequired.iii)Duplex Panel
40iii)SimplexPanel,DCPanel,RTCCPanel,PLCCPanel etc. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57816479
AUTHORITY Government Departments
TENDER VALUE 5.31 Lakhs
LAST DATE 15-10-2026
Authority
Authority Name Rajasthan Rajya Vidhyut Prasaran Nigam Limited
Work Description Tender for Replacement Of Various Equipments At 132 Kv Gss Sagwara ,02 X 33 Kv Feeder Bay At 132 Kv Gss Sagwara & 01 No. 132 Kv Feeder Bay At 220 Kv Gss Sagwara.
Basic Detail
Tender No NIB 24/2026-27_3410002609
Bidding Type Tender
Location
City Dungarpur
State Rajasthan
Key Dates
Publish Date 01 Oct 2026
Submission Date 15 Oct 2026
Open Date 16 Oct 2026
Finance
Tender Value 5.31 Lakhs
Tender Fee 1180
EMD 10650
Exemption Not Available
Document List
BOQ_1068198.xls
D639Bid24DOCSRSPPP.pdf
fa02e839-251e-4c4f-91ed-104ea1ed1b72.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Oct 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1068198.xls

pdf

D639Bid24DOCSRSPPP.pdf

html

fa02e839-251e-4c4f-91ed-104ea1ed1b72.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders